• Title/Summary/Keyword: cutoff time

Search Result 182, Processing Time 0.028 seconds

Fast Measurement using Wave-Cutoff Method

  • Seo, Sang-Hun;Na, Byeong-Geun;Yu, Gwang-Ho;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.30-30
    • /
    • 2011
  • The wave-cutoff tool is a new diagnostic method to measure electron density and electron temperature. Most of the plasma diagnostic tools have the disadvantage that their application to processing plasma where toxic and reactive gases are used gives rise to many problems such as contamination, perturbation, precision of measurement, and so on. We can minimize these problems by using the wave-cutoff method. Here, we will present the results obtained through the development of the wave-cutoff diagnostic method. The frequency spectrum characteristics of the wave-cutoff probe will be obtained experimentally and analyzed through the microwave field simulation by using the CST-MW studio simulator. The plasma parameters are measured with the wave-cutoff method in various discharge conditions and its results will be compared with the results of Langmuir probe. Another disadvantage is that other diagnostic methods spend a long time (~ a few seconds) to measure plasma parameters. In this presentation, a fast measurement method will be also introduced. The wave-cutoff probe system consists of two antennas and a network analyzer. The network analyzer provides the transmission spectrum and the reflection spectrum by frequency sweeping. The plasma parameters such as electron density and electron temperature are obtained through these spectra. The frequency sweeping time, the time resolution of the wave-cutoff method, is about 1 second. A short pulse with a broad band spectrum of a few GHz is used with an oscilloscope to acquire the spectra data in a short time. The data acquisition time can be reduced with this method. Here, the plasma parameter measurement methods, Langmuir probe, pulsed wave-cutoff method and frequency sweeping wave-cutoff method, are compared. The measurement results are well matched. The real time resolution is less than 1 ?sec. The pulsed wave-cutoff technique is found to be very useful in the transient plasmas such as pulsed plasma and tokamak edge plasma.

  • PDF

5 Repetition Sit-to-Stand Test of Stroke patients and Healthy Older (뇌졸중 환자와 노인의 의자에서 일어서기 수행평가)

  • Kwon, Mi-Ji
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.1
    • /
    • pp.101-106
    • /
    • 2014
  • PURPOSE: This study was to provide reference data and examine stroke and healty older differences in sit-to-stand test. This study were to determine utility of the 5 repetition sit to stand for discriminating between fallers and non-fallers, identifying an appropriate cutoff score to delineate between the groups. METHODS: Ninety-five participants were recruited. Seventy-two individuals with stroke and twenty-three healthy older agreed to participate in the study. Falls were recorded using a self-administered questionnaire. The 5 repetition sit to stand test measured the time taken to complete t repetitions of the sit to stand maneuver. The time from the initial seated position to the final seated position after completing five stands was the test measure. A cutoff score regarding 5 repetition sit to stand performance in fallers vs. non-fallers, stroke patients vs. healthy older and <60 vs. $$\geq_-$$ age groups was determined using and ROC curve. RESULTS: Cutoff score of 9.9 seconds were found to be discriminatory between healthy older and subjects with stroke. Cutoff score of 15.5 seconds were found to be discriminatory between fallers and non-fallers. Cutoff score of 18.3 seconds were found to be discriminatory between <60 and $$\geq_-$$ age groups. CONCLUSION: The 5-repetition sit-to stand test is quick, easily administered measure useful for gross determination of fall risk in people with stroke.

Flow Characteristics due to Cutoff angle of Turbo-Fan for Industries (산업용 Turbo형 송풍기의 Cutoff 각도에 따른 유동특성)

  • Yun, Ji-Hun;Jeong, In-Guk;Yi, Chung-Seob;Suh, Jeong-Se
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.5
    • /
    • pp.91-96
    • /
    • 2011
  • This study aims to analyze the flow characteristics of turbo-fan which is applied to the industrial field. Numerical analysis has been carried out to investigate the pulsation behavior of exhaust air flown out turbo fan by rotating impeller with constant speed. Moving mesh technique is proved as time-accurate solution for the flow inside impeller. As numerical results come within the error range of 1% by comparing with theoretical results, the numerical analysis can be verified. Cutoff angle has large influence on the amplitude of pulsation and the least pulsation of flow can be generated by the cutoff angle of $20^{\circ}$.

The Design of A CMOS Gm-C Lowpass Filter with Variable Cutoff Frequency for Direct Conversion Receiver (직접변환 수신기용 가변 차단주파수특성을 갖는 CMOS Gm-C 저역통과필터 설계)

  • Bang, Jun-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1464-1469
    • /
    • 2008
  • A CMOS Gm-C filter with variable cutoff frequency applicable for using in the direct conversion receiver is designed. The designed filter comprises the CMOS differential transconductors, and the gm of the transconductor is controlled by the bias voltage. This configuration can compensate variant of the cutoff frequency which could be generated by external noises, and also be used in multiband receiver. As a results of HSPICE simulation, the control range of the cutoff frequency is $1.5MHz{\sim}3.5MHz$ and the gain control range is $-2.8dB{\sim}2.6dB$. The layout of the designed 5th-order Elliptic low-pass filter is performed to fabricate a chip using $2.5V-0.25{\mu}m$ CMOS processing parameter.

High Frequency Noise Reduction in ECG using a Time-Varying Variable Cutoff Frequency Lowpass Filter (시변 가변차단주파수 저역통과필터를 이용한 심전도 고주파 잡음의 제거)

  • 최안식;우응제;박승훈;윤영로
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.137-144
    • /
    • 2004
  • ECG signals are often contaminated with high-frequency noise such as muscle artifact, power line interference, and others. In the ECG signal processing, especially during a pre-processing stage, numerous noise removal techniques have been used to reduce these high-frequency noise without much distorting the original signal. This paper proposes a new type of digital filter with a continuously variable cutoff frequency to improve the signal quality This filter consists of a cutoff frequency controller (CFC) and variable cutoff frequency lowpass filter (VCF-LPF). From the noisy input ECG signal, CFC produces a cutoff frequency control signal using the signal slew rate. We implemented VCF-LPF based on two new filter design methods called convex combination filter (CCF) and weight interpolation fille. (WIF). These two methods allow us to change the cutoff frequency of a lowpass filter In an arbitrary fine step. VCF-LPF shows an excellent noise reduction capability for the entire time segment of ECG excluding the rising and falling edge of a very sharp QRS complex. We found VCF-LPF very useful and practical for better signal visualization and probably for better ECG interpretation. We expect this new digital filter will find its applications especially in a home health management system where the measured ECG signals are easily contaminated with high-frequency noises .

A Parameter Extraction Method for BJT Gummel-Poon Model (BJT Gummel-Poon 모델 파라미터 추출 방법)

  • 윤신섭;이성현
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.763-766
    • /
    • 2003
  • A direct parameter extraction method using several two-port parameter equations derived in cutoff and active bias modes has been studied to obtain an accurate Gummel-Poon BJT model. First, dc model parameters were extracted from slopes and y-axis intercepts of I-V curve and Gummel plot. The pad capacitances and junction capacitance parameters were determined by using measured S-parameter sets in the cutoff bias. The resistance and transit time parameters were extracted by using measured S-parameter sets in the active bias.

  • PDF

Review on the Pertinent Discount Rate for the Public Investment Project (공공투자사업(公共投資事業)의 적정(適正) 할인율(割引率) 검토(檢討)에 관(關)한 연구(硏究))

  • Park, Jae Keun;Lim, Jae Hwan
    • Korean Journal of Agricultural Science
    • /
    • v.30 no.1
    • /
    • pp.89-101
    • /
    • 2003
  • For the pre-feasibility study and project evaluation, the discount rate or cutoff rate should be given by the government authority. To get the Benefit/Cost Ratio, NPV(Net Present Value) and IRR(Internal Rate of Return) of the public investment projects, the pertinent and realistic discount rate should be determined to be suitable to the present time period. The cut-off rates in Korea were equivalent to 15% in 1970's, 10% in 1980's and 8% in 1990's. The prevailing rate of discount as 8% is considered not to be suitable for the 2000's public project appraisal considering the present interest rates on deposit and national bonds. To determine the socio-economic feasibility of the public projects, the IRR should be bigger than the present cutoff rate. When we still use the high old rate of discount, the analytical results of project appraisal will show always economically unfeasible. Therefore the new rate of discount suitable for present time should be determined by the government. The public projects to be implemented in 2000 year onward are recommended to be adapted 5% of cutoff rate for the project appraisal and evaluation according to the results of reviewing the tendency of discount rates and market rates of interest in Korea.

  • PDF

Gate-Length Dependent Cutoff Frequency Extraction for Nano-Scale MOSFET (Nano-Scale MOSFET의 게이트길이 종속 차단주파수 추출)

  • Kim, Joung-Hyck;Lee, Yong-Taek;Choi, Mun-Sung;Ku, Ja-Nam;Lee, Seong-Heam
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.12
    • /
    • pp.1-8
    • /
    • 2005
  • The gate length-dependence of cutoff frequency is modeled by using scaling parameter equations of equivalent circuit parameters extracted from measured S-parameters of Nano-scale MOSFETs. It is observed that the modeled cutoff frequency initially increases with decreasing gate length and then the rate of increase becomes degraded at further scale-down. This is because the extrinsic charging time slightly decreases, although the intrinsic transit time greatly decreases with gate length reduction. The new gate length-dependent model will be very helpful to optimize RF performances of Nano-scale MOSFETs.

Secular change in waist circumference and waist-height ratio and optimal cutoff of waist-height ratio for abdominal obesity among Korean children and adolescents over 10 years

  • Kim, Min Sub;Kim, Se Young;Kim, Jae Hyun
    • Clinical and Experimental Pediatrics
    • /
    • v.62 no.7
    • /
    • pp.261-268
    • /
    • 2019
  • Purpose: This study aimed to evaluate the time trends of waist circumference (WC) and waist-height ratio (WHR), and to present WC and WHR distributions with optimal WHR cutoff for abdominal obesity in Korean children and adolescents. Methods: We performed a retrospective cross-sectional analysis of data from 13,257 children and adolescents (6,987 boys and 6,270 girls) aged 6-18 years who were included in the third to sixth Korea National Health and Nutrition Examination Survey (KNHANES, 2005-2015). Linear regression analyses were used to identify secular changes in WC and WHR by age, sex, and KNHANES waves. A receiver operating characteristic curve analysis was used to determine the optimal WHR cutoff values for abdominal obesity and cardiometabolic risk factors. Results: The mean WC and WHR distributions from 2005 to 2015 showed no significant secular changes between the KNHANES 4 waves (P for trend ${\geq}0.05$ in all ages and both sexes). The mean WCs in the present study were lower than those in the 2007 Korean National Growth Charts. The mean WHR at ages <13 years was statistically higher in the boys than in the girls, but did not significantly differ between the sexes among those aged 13 to 18 years. The optimal WHR cutoff for abdominal obesity was 0.48 (area under the curve, 0.985; 95% confidence interval, 0.985-0.985) in the 13- to 18-year-old adolescents. Conclusion: WC and WHR showed no secular changes over 10 years. The optimal WHR cutoff for abdominal obesity of 0.48 is useful for diagnosing and managing obesity and thus preventing obesity-related cardiometabolic complications in 13- to 18-year-old Korean adolescents.

Quantitative Analysis of Artifactual Perfusion Defects due to the Cutoff Frequencies of Reconstruction Filters in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT에서 재구성필터의 차단주파수에 의한 인위적 관류결손의 정량적 평가)

  • Kwark, Cheol-Eun;Chung, June-Key;Lee, Myung-Chul
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.231-238
    • /
    • 1995
  • Tc-99m-MIBI (Sestamibi) myocardial SPECT along with TI-201 tomographic Imaging has demonstrated wide application and high image quality sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow. The qualitative values of myocardial SPECT with Tc-99m-MIBI as well ds the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection (FBP) Is the common standard method for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected litter parameters such as cutoff frequencies and order (Butterworth case) The cutoff frequencies used in clinicAl practice partially remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for Identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable threshold of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Wyquist frequency would reveal severe degradation of radioactive distribution near inferior and/or inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF