Tc-99m DMSA SPECT for Follow-Up of Non-Operative Treatments in Renal Injuries: A Prospective Single-Center Study

  • Sang-Geon Cho;Ki Seong Park;Jahae Kim;Jang Bae Moon;Ho-Chun Song;Taek Won Kang;Seong Hyeon Yu
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.1017-1027
    • /
    • 2023
  • Objective: The assessment of cortical integrity following renal injuries with planar Tc-99m dimercaptosuccinic acid (DMSA) scintigraphy depends on measuring relatively decreased cortical uptake (i.e., split renal function [SRF]). We analyzed the additive values of the volumetric and quantitative analyses of the residual cortical integrity using single-photon emission computed tomography (SPECT) compared to the planar scintigraphy. Materials and Methods: This prospective study included 47 patients (male:female, 32:15; age, 47 ± 22 years) who had non-operatively managed renal injuries and underwent DMSA planar and SPECT imaging 3-6 months after the index injury. In addition to planar SRF, SPECT SRF, cortical volume, and absolute cortical uptake were measured for the injured kidney and both kidneys together. The correlations of planar SRF with SPECT SRF and those of SRF with volumetric/quantitative parameters obtained with SPECT were analyzed. The association of SPECT parameters with renal function, grades of renal injuries, and the risk of renal failure was also analyzed. Results: SPECT SRF was significantly lower than planar SRF, with particularly higher biases in severe renal injuries. Planar and SPECT SRF (dichotomized with a cutoff of 45%) showed 19%-36% of discrepancies with volumetric and quantitative DMSA indices (when dichotomized as either high or low). Absolute cortical uptake of the injured kidney best correlated with glomerular filtration rate (GFR) at follow-up (ρ = 0.687, P < 0.001) with significant stepwise decreases by GFR strata (90 and 60 mL/min/1.73 m2). Total renal cortical uptake was significantly lower in patients with moderate-to-high risk of renal failure than those with low risk. However, SRF did not reflect GFR decrease below 60 mL/min/1.73 m2 or the risk of renal failure, regardless of planar or SPECT (count- or volume-based SRF) imaging. Conclusion: Quantitative measurements of renal cortical integrity assessed with DMSA SPECT can provide more clinically relevant and comprehensive information than planar imaging or SRF alone.

Usefulness of Bone SPECT/CT for Predicting Avascular Necrosis of the Femoral Head in Children with Slipped Capital Femoral Epiphysis or Femoral Neck Fracture

  • Yoo Sung Song;Won Woo Lee;Moon Seok Park;Nak Tscheol Kim;Ki Hyuk Sung
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.264-270
    • /
    • 2022
  • Objective: This study aimed to investigate the usefulness of bone single-positron emission tomography/computed tomography (SPECT/CT) of the hip in predicting the later occurrence of avascular necrosis (AVN) after slipped capital femoral epiphysis (SCFE) or femoral neck fracture in pediatric patients. The quantitative parameters of SPECT/CT useful in predicting AVN were identified. Materials and Methods: Twenty-one (male:female, 10:11) consecutive patients aged < 18 years (mean age ± standard deviation [SD], 11.0 ± 2.7 years) who underwent surgery for SCFE or femoral neck fracture and postoperative bone SPECT/CT were included. The maximum standardized uptake value (SUV), mean SUV, and minimum SUV of the femoral head were measured. The ratios of the maximum SUV, mean SUV, and minimum SUV of the affected femoral head to the contralateral side were determined. Patients were followed up for > 1 year after the surgery. The SPECT/CT parameters were compared between patients who developed AVN and those who did not. The accuracy of SPECT/CT parameters for predicting AVN was assessed. Results: Six patients developed AVN. There was a significant difference in the ratio of the mean SUV among patients who developed AVN (mean ± SD, 0.8 ± 0.3) and those who did not (1.1 ± 0.2, p = 0.018). However, there were no significant differences in the ratios of the maximum and minimum SUV between the groups (all p = 0.205). For the maximum, mean, and minimum SUVs, no significant differences were observed between the groups (p = 0.519, 0.733, and 0.470, respectively). The cutoff mean SUV ratio of 0.87 yielded a 66.7% sensitivity and 93.2% specificity for predicting AVN. Conclusion: Quantitative bone SPECT/CT is useful for evaluating femoral head viability in pediatric patients with SCFE or femoral neck fractures. Clinicians should consider the high possibility of later AVN development in patients with a decreased mean SUV ratio.

Prognostic Value of Sarcopenia and Myosteatosis in Patients with Resectable Pancreatic Ductal Adenocarcinoma

  • Dong Wook Kim;Hyemin Ahn;Kyung Won Kim;Seung Soo Lee;Hwa Jung Kim;Yousun Ko;Taeyong Park;Jeongjin Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.11
    • /
    • pp.1055-1066
    • /
    • 2022
  • Objective: The clinical relevance of myosteatosis has not been well evaluated in patients with pancreatic ductal adenocarcinoma (PDAC), although sarcopenia has been extensively researched. Therefore, we evaluated the prognostic value of muscle quality, including myosteatosis, in patients with resectable PDAC treated surgically. Materials and Methods: We retrospectively evaluated 347 patients with resectable PDAC who underwent curative surgery (mean age ± standard deviation, 63.6 ± 9.6 years; 202 male). Automatic muscle segmentation was performed on preoperative computed tomography (CT) images using an artificial intelligence program. A single axial image of the portal phase at the inferior endplate level of the L3 vertebra was used for analysis in each patient. Sarcopenia was evaluated using the skeletal muscle index, calculated as the skeletal muscle area (SMA) divided by the height squared. The mean SMA attenuation was used to evaluate myosteatosis. Diagnostic cutoff values for sarcopenia and myosteatosis were devised using the Contal and O'Quigley methods, and patients were classified according to normal (nMT), sarcopenic (sMT), myosteatotic (mMT), or combined (cMT) muscle quality types. Multivariable Cox regression analyses were conducted to assess the effects of muscle type on the overall survival (OS) and recurrence-free survival (RFS) after surgery. Results: Eighty-four (24.2%), 73 (21.0%), 75 (21.6%), and 115 (33.1%) patients were classified as having nMT, sMT, mMT, and cMT, respectively. Compared to nMT, mMT and cMT were significantly associated with poorer OS, with hazard ratios (HRs) of 1.49 (95% confidence interval, 1.00-2.22) and 1.68 (1.16-2.43), respectively, while sMT was not (HR of 1.40 [0.94-2.10]). Only mMT was significantly associated with poorer RFS, with an HR of 1.59 (1.07-2.35), while sMT and cMT were not. Conclusion: Myosteatosis was associated with poor OS and RFS in patients with resectable PDAC who underwent curative surgery.

Evaluating the Usability of Medical Body Wrap in Whole Body Bone Scan (전신 뼈 검사에서 의료용 신체 고정구의 유용성 평가)

  • Dong-Oh Shim;Woo-Young Jung;Jae-Kwang Ryu;Cheol-Hong Park;Yoon-Jae Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.49-56
    • /
    • 2024
  • Purpose: When performing nuclear medicine examinations, body wraps or plastic supports are used to support and immobilize the patient's upper extremities to prevent patient safety accidents. However, the existing plastic supports compromised patient and staff safety, including finger entrapment and falls. Moreover, the body wrap provided by manufacturers compromised image quality such as upper extremities cutoff during whole body bone scan. Therefore, a new design of body wrap was developed to improve the issue, and this study aims to evaluate the usability of this medical body wrap. Materials and Methods: To evaluate the usability of the newly designed medical body wrap, a quality assessment of whole body bone scan images and a user satisfaction survey were conducted. Adult patients (male:female=129:152, age: 60.3±12.4 years, BMI: 24.0±4.2) aged 16 years or older who underwent a whole body bone scan during two periods: June to July 2022 (before improvement, n=139) and June to July 2023 (after improvement, n=142) were randomly selected for image quality evaluation. Five radiotechnologists visually evaluated the posterior view of the whole body bone image, including the left and right elbow (2 points), arm (2 points), whether the hand is extended (2 points), whether the hand is included (2 points), and the number of visible fingers (10 points), with a total of 18 points, which were converted to 100 points and analyzed for difference before and after improvement using an independent sample t-test. The user satisfaction questionnaire was evaluated using a 5-point Likert scale among 16 radiotechnologists from three general hospitals who experienced the new body wrap. Results: The image quality assessment was 82.0±13.8 before the improvement and 89.3±10.1 after the improvement, an average of 7.3 points higher, with a statistically significant difference (t=5.02, p<0.01). The user satisfaction survey showed an overall satisfaction rating of 4.1±0.8 for ease of use, 3.8±0.7 for scan preparation time, 3.9±0.7 for patient safety, 3.8±1.2 for scan accuracy, and 4.2±0.7 for recommendation (87.5% questionnaire response rate). Conclusion: The developed body wrap showed higher image quality and user satisfaction compared to the old method. Considering these results, it is deemed that the new body wrap may be more useful than existing methods.

Diffusion-Weighted Imaging for Differentiation of Biliary Atresia and Grading of Hepatic Fibrosis in Infants with Cholestasis

  • Jisoo Kim;Hyun Joo Shin;Haesung Yoon;Seok Joo Han;Hong Koh;Myung-Joon Kim;Mi-Jung Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.2
    • /
    • pp.253-262
    • /
    • 2021
  • Objective: To determine whether the values of hepatic apparent diffusion coefficient (ADC) can differentiate biliary atresia (BA) from non-BA or be correlated with the grade of hepatic fibrosis in infants with cholestasis. Materials and Methods: This retrospective cohort study included infants who received liver MRI examinations to evaluate cholestasis from July 2009 to October 2017. Liver ADC, ADC ratio of liver/spleen, aspartate aminotransferase to platelet ratio index (APRI), and spleen size were compared between the BA and non-BA groups. The diagnostic performances of all parameters for significant fibrosis (F3-4) were obtained by receiver-operating characteristics (ROCs) curve analysis. Results: Altogether, 227 infants (98 males and 129 females, mean age = 57.2 ± 36.3 days) including 125 BA patients were analyzed. The absolute ADC difference between two reviewers was 0.10 mm2/s for both liver and spleen. Liver ADC value was specific (80.4%) and ADC ratio was sensitive (88.0%) for the diagnosis of BA with comparable performance. There were 33 patients with F0, 15 with F1, 71 with F2, 35 with F3, and 11 with F4. All four parameters of APRI (τ = 0.296), spleen size (τ = 0.312), liver ADC (τ = -0.206), and ADC ratio (τ = -0.288) showed significant correlation with fibrosis grade (all, p < 0.001). The cutoff values for significant fibrosis (F3-4) were 0.783 for APRI (area under the ROC curve [AUC], 0.721), 5.9 cm for spleen size (AUC, 0.719), 1.044 x 10-3 mm2/s for liver ADC (AUC, 0.673), and 1.22 for ADC ratio (AUC, 0.651). Conclusion: Liver ADC values and ADC ratio of liver/spleen showed limited additional diagnostic performance for differentiating BA from non-BA and predicting significant hepatic fibrosis in infants with cholestasis.

Clinical review of Epstein-Barr virus viremia in Korean children by using real-time PCR (한국인 소아에서 실시간 중합효소연쇄반응으로 검출된 Epstein-Barr virus 바이러스혈증의 임상적 고찰)

  • Ko, Il Yong;Suh, Jin Suk;Kim, Hwang Min;Sohn, Joon Hyung;Yeh, Byung-Il;Lee, Taek Jin;Kim, Dong Soo
    • Pediatric Infection and Vaccine
    • /
    • v.14 no.2
    • /
    • pp.171-178
    • /
    • 2007
  • Purpose : We investigated clinical characteristics of real-time PCR proven EBV viremia patients who were not serologically diagnosed but clinically suspected, and compared it to serologically proven EBV infected patients. Methods : The study population consisted of 45 patients, who were suspected acute EBV infection at Wonju Christian Hospital Department of Pediatrics, Yonsei University Wonju College of Medicine from Jan. 2004 to Dec. 2006. real-time PCR of cell free serum was performed to prove EBV viremia. Then we chose $102.5copies/{\mu}g$ DNA as a suitable cutoff level for EBV associated diseases. Results : There are 4 patients diagnosed as EBV infection by serologically and 15 patients diagnosed as EBV viremia by real-time PCR quantitative measurement. The most common presenting symptoms and signs of EBV viremia was fever in 11 cases (73%). Atypical lymphocytosis was found in 4 cases (27%). Increased AST, ALT levels were observed in 13 cases (87%), 12 cases (80%), respectively. We could diagnose 5 cases of EBV viremia younger than one year of age. They revealed clinical symptoms which could be found in EBV infection. The serologically diagnosed patients had hepatomegaly and splenomegaly in 3 cases (75%). All serologically confirmed patients have leukocytosis above $20,000/mm^3$, among them 2 cases (50%) had higher percentage (>15%) of atypical lymphocytes. The AST/ALT level above 50 IU/L were demonstrated in all cases. Conclusion : Serologically unproven real-time PCR EBV viremia patients revealed similar clinical findings with that of serologically proven EBV infected patients. So, it is meaningful to perform EBV real-time PCR for the diagnosis of EBV infection especially for the cases younger than 1 year of age.

  • PDF

Application of HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version) to screening test of noise-induced hearing loss (소음성 난청 선별검사에 HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version)의 적용)

  • Lee, Mi-Young;Suh, Suk-Kwon;Lee, Choong-Won
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.539-553
    • /
    • 1996
  • The study was conducted from May to September in 1994 to investigate applicability of the Hearing Handicap Inventory for the Elderly-Screening version(HHIE-S) in parallel with the pure-tone audiometer to the initial screening test of noise-induced hearing loss(NIHL) in some noise-exposed workers. Subjects were selected by systemic sampling that took every 10th person from 6, 700 workers taking the annual occupational health examination by the department of Health Maintenance of Dongsan Hospital Keimyung University in Taegu. The authors administered the pure-tone audiometric test and self-reported questionnaire of HHIE-S including items of sociodemographic and job-related variables concurrently. The final subjects analysed were 1,019(488 males and 531 females) excluding fourteen persons who had many missing values in their questionnaires. The reliability coefficients of HHIE-S scale by Cronbach's alpha were 0.84. In the univariate analysis of hearing handicap measured by the HHIE-S, work duration, military service and the hearing threshold loss at 1KHz and 4KHz by the initial audiometer were significant in males while age, work duration and hearing threshold loss at 1KHz and 4KHz were significant in females. In the stepwise linear regression analysis, hearing threshold loss at 1KHz and 4KHz, was the only selected variable explaining the hearing handicap in males and hearing threshold loss at 1KHz and 4KHz, age, and work duration were selected in females. In ROC curves for HHIE-S scores against NIHL as gold standard which was defined by the follow-up audiogram as more than 30dB of the average of 0.5/1/2KHz and 50dB at 4KHz, the optimal cutoff for the parallel HHIE-S appeared to be 8. The results suggest that HHIE-S appeared to have some reliability and validity in this data and might be used in screening NIHL in parallel with pure-tone audiometer in noise-exposed workers.

  • PDF

Relationship between Insomnia and Depression in Type 2 Diabetics (2형 당뇨병 환자에서 불면증과 우울 증상의 관련성)

  • Lee, Jin Hwan;Cheon, Jin Sook;Choi, Young Sik;Kim, Ho Chan;Oh, Byoung Hoon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.27 no.1
    • /
    • pp.50-59
    • /
    • 2019
  • Objectives : Many of the patients with type 2 diabetes are associated with sleep problems, and the rate of insomnia is known to be higher in the general population. The aims of this study were to know the frequency and clnical characteristics of insomnia, and related variables to insomnia in patients diagnosed with type 2 diabetes. Methods : For 99 patients from 18 to 80 years of age (65 males and 34 females) with type 2 diabetes, interviews were performed. Total sleep time and sleep latency was evaluated. Insomnia was evaluated using the Korean Version of the Insomnia Severity Index (ISI-K). Severity of depressive symptoms were evaluted using the Korean version of the Hamilton Depression Scale (K-HDRM). According to the cutoff score of 15.5 on the ISI-K, subjects were divided into the group of type 2 diabetics with insomnia (N=34) and those without insomnia (N=65) at first, and then statistically analyzed. Results : TInsomnia could be found in 34.34% of type 2 diabetics. Type 2 diabetics with insomnia had significantly more single or divorced (respectively 11.8%, p<0.05), higher total scores of the K-HDRS ($11.76{\pm}5.52$, p<0.001), shorter total sleep time ($5.35{\pm}2.00hours$, p<0.001), and longer sleep latency ($50.29{\pm}33.80minutes$, p<0.001). The all item scores of the ISI-K in type 2 diabetics with insomnia were significantly higher than those in type 2 diabetics without insomnia, that is, total ($18.38{\pm}2.69$), A1 (Initial insomnia) ($2.97{\pm}0.76$), A2 (Middle insomnia) ($3.06{\pm}0.69$), A3 (Terminal insomnia) ($2.76{\pm}0.61$), B (Satisfaction) ($3.18{\pm}0.72$), C (Interference) ($2.09{\pm}0.97$), D (Noticeability) ($2.12{\pm}1.09$) and E (Distress) ($2.21{\pm}0.81$) (respectively p<0.001). Variables associated with insomnia in type 2 diabetics were as following. Age had significant negative correlation with A3 items of the ISI-K (${\beta}=-0.241$, p<0.05). Total scores of the K-HDRS had significant positive correlation, while total sleep time had significant negative correlation with all items of the ISI-K (respectively p<0.05). Sleep latency had significant positive correlation with total,, A1, B and E item scores of the ISI-K (respectively p<0.05). Conclusions : Insomnia was found in about 1/3 of type 2 diabetics. According to the presence of insomnia, clinical characteristics including sleep quality as well as quantity seemed to be different. Because depression seemed to be correlated with insomnia, clinicians should pay attention to early detection and intervention of depression among type 2 diabetics.

Influence of Different Diagnostic Criteria on Frequency of Convergence Insufficiency (진단기준 차이가 폭주부족의 빈도에 미치는 영향)

  • Yu, Dong-Sik;Cho, Hyun Gug;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.235-242
    • /
    • 2016
  • Purpose: This study was to investigate whether the application of different diagnostic criteria affected the frequency of convergence insufficiency (CI). Methods: Eighty one subjects with mean age of 22.54 years (20 to 27 years) were evaluated. Binocularity tests after refraction were performed as the following tests: near point of convergence (NPC) with an accommodative target, phoria using von Graefe method, positive fusional vergence (PFV) with a phoropter. Subjects with CI were diagnosed when exophoria (exo) was greater at near than at distance ($exo{\geq}4{\Delta}$, or >$6{\Delta}$), fusional vergence was $PFV{\leq}11{\Delta}$ for blur, $PFV{\leq}15{\Delta}$ for break, Sheard's or Percival's criterion, and NPC was $NPC{\geq}6cm$, ${\geq}7.5cm$ or >10 cm. Results: Frequency of CI with one diagnostic criterion was ranged from 6.2% to 77.8%, and was overestimated or underestimated according to criteria. It was reduced to the range of 6.2% to 43.2% with diagnostic criteria more than two, especially to the range of 24.7% to 28.4% with lower variability in diagnostic criteria including phoria and Sheard's criterion. There were high relationship between total score of signs and phoria score (r = 0.772, p<0.001), and measured phoria and Sheard's criterion (r = -0.654, p<0.001), but NPC had a high variability and a weak or no significant relationship with other diagnostic criteria. Results suggested $exo{\geq}4{\Delta}$, Sheard's criterion and $NPC{\geq}7.5cm$ for diagnostic criteria of signs and sequence for CI. Conclusions: Frequency of CI is likely to be over- and underestimated with diagnostic criteria. Cutoff values and procedures for phoria, Sheard's criterion and NPC as clinical signs should be suggested definitely in diagnosis associated with CI.

Diagnostic Accuracy of PET and MR for Detecting Liver Metastasis from Colorectal Cancer (대장-직장암의 간전이에서 FDG PET과 MR의 진단 성능)

  • Park, Eun-Kyung;Kang, Won-Jun;Eo, Jae-Seon;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.5
    • /
    • pp.249-256
    • /
    • 2006
  • Purpose: Although computed tomography (CT) is widely used for diagnosing liver metastasis from colorectal cancer, diagnostic accuracy of CT is not satisfactory. Magnetic resonance (MR) imaging and F-18 FDG PET has been reported to be superior to CT. However, studies on direct comparison of PET and MR are scarce. We compared the diagnostic accuracy of FDG PET and MR in detecting liver metastasis from colorectal cancer. Materials and Methods: Among 363 colorectal cancer patients who underwent F-18 FDG PET (ECAT, Siemens-CTI, Knoxville; Gemini, Philips, Milpitas, U.S.), 26 patients (M:F=17:9, age=$62{\pm}11$) underwent MR to evaluate suspicious metastatic liver lesions. Finally, 35 liver lesions detected by CT from 26 patients were enrolled for analysis. PET and MR results were compared with pathologic reports, clinical findings or follow-up results. Results: Of the 35 lesions, 18 lesions (51.4%) were diagnosed as liver metastases, while remaining 17 (48.6%) as benign. The sensitivity and the specificity of PET were 94.4% and 94.1%, respectively, compared to 100% and 82.4% for MR. MR and PET was concordant in 30 lesions (85.7%: 17 metastatic (94.4%) and 13 benign (76.5%) lesions. ROC curve analysis revealed maximal SUV of 3.1 as the optimum standard in differentiating metastatic from benign liver lesions (AUC=0.897, p<0.001, sensitivity 83.3%, specificity 94.1%). For small lesions less than 1 cm ln diameter (n=20), diagnostic accuracy of PET was comparable to that of MR. Conclusion: F-18 FDG PET showed good diagnostic performance in detecting liver metastasis from colorectal cancer, which was comparable to MR.