• Title/Summary/Keyword: custom-made

Search Result 352, Processing Time 0.022 seconds

A simple technique for impression taking of teeth and functionally generated paths

  • Yamamoto, Takatsugu;Sato, Yohei;Watanabe, Hidehiko;Punj, Amit;Abe, Minoru;Momoi, Yasuko;Ohkubo, Chikahiro
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.1
    • /
    • pp.9.1-9.6
    • /
    • 2018
  • The objective of this case report is to introduce a simple technique for simultaneously taking a closed-mouth impression and functionally generated path (FGP) for a full coverage crown restoration. A monolithic zirconia crown was the restoration of choice. An alginate impression of the abutment tooth was taken to fabricate a custom-made closed-mouth impression tray covering the abutment tooth and the adjacent teeth. The tray had an FGP table and an abutment tray in cameo and intaglio surfaces, respectively. The impression was taken with silicone impression material after adjusting the abutment tray and inscribing the FGP using self-curing acrylic resins. Plaster casts were made from the impression, and a zirconia crown was fabricated. The crown was cemented to the abutment tooth with minimal adjustments. This simple technique resulted in a well-fitting crown that accounted for mandibular movements. Using the custom closed-mouth impression tray incorporating an FGP table simultaneously aids in fabricating an accurately fitting restoration that incorporates harmonious mandibular movements using a single impression capture.

Cranioplasty Using Autologous Bone versus Porous Polyethylene versus Custom-Made Titanium Mesh : A Retrospective Review of 108 Patients

  • Kim, Jun-Ki;Lee, Sang-Bok;Yang, Seo-Yeon
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.6
    • /
    • pp.737-746
    • /
    • 2018
  • Objective : The purpose of this study was to compare the cosmetic outcome and complications after cranioplasty (CP) due to three different implant materials, and analyze the mean implant survival and cumulative survival rate based on these results. Methods : We reviewed 108 patients retrospectively who underwent CP between January 2014 and November 2016. Autologous bone (AB; 45 patients) and synthetic materials with porous polyethylene (PP; 32 patients) and custom-made 3-dimensional printed titanium mesh (CT; 31 patients) were used as implants. Results : Regardless of implanted materials, more than 89.8% of the CP patients were satisfied with the cosmetic outcome. No statistically significant difference was observed among the three groups. The overall postoperative complication rates of each group were 31.1% in the AB group, 15.6% in the PP group and 3.2% in the CT group. The CT group showed lower complication rates compared with AB and PP groups (${\chi}^2$-test : AB vs. PP, p=0.34; AB vs. CT, p=0.00; PP vs. CT, p=0.03). The AB and PP groups demonstrated a higher post-CP infection rate (11.1% and 6.3%) than the CT group (3.2%). However, no significant difference in the incidence of post-CP infection was observed among the three groups. The PP and CT groups demonstrated a higher mean implant survival time and cumulative survival rate than the AB group at the last follow-up (p<0.05). Conclusion : In comparison with AB and PP, cranioplasty with CT shows benefits in terms of lower post-CP complication, less intraoperative bleeding loss, shorter operation time and in-hospital stay. The PP and CT groups showed higher implant survival time and cumulative survival rate compared with the AB group.

A Spectrophotometric Study on Color Differences between Various Light-Cured Composite Resins and Shade Guides (광중합형 복합레진과 shade guide의 색차에 관한 연구)

  • Lim, Kyung-Min;Lee, Min-Ho;Song, Kwang-Yeob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.13-22
    • /
    • 2009
  • The composite resin, due to its esthetic quality, is considered the material of choice for restoration of anterior teeth. To get a satisfactory result in the composite resin restorations, it is necessary to choose right shade. At present, most of the commercial composite resins are based on the Vita Lumin shade guides or shade guides that are provided by their company, but color differences among them might be expected even using the same shade in various materials. This study is to measure color differences between various light-cured composite resins and shade guides and to provide the clinicians with information which may aid in improved color match of esthetic restoration. Four kinds of light-cured composite resins (Gradia Direct (GD), Z250 (Z250), Clearfil AP-X (AP-X), Esthet X (E X)) and shade guides with A2 and A3 shade were used. Three specimens of each material and one specimen of each shade guide were made. Each composite resin was filled into the Teflon mold (1.35 mm depth, 8 mm diameter), followed by compression, polymerization and polishing with wet sandpaper. Shade guides were grinded with polishing stones and rubber points to a thickness of approximately 1.35 mm. Color characteristics were performed with a spectrophotometer(color i5, GretagMacbeth, USA). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E^*ab$) between composite resins and shade guides. CIE standard D65 was used as the light source. The results were as follows : 1. Among the $L^*$, $a^*$, $b^*$ values of most of 4 kinds of composite resin specimens which are produced by same shade, there were significant differences(p<0.05). 2. Among all 4 kinds of composite resin specimens which are produced by same shade, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 3. Between most of composite resin specimens investigated and their corresponding shade guides, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 4. In the clinical environment, it is recommended that custom shade guides be made from resin material itself for better color matching. Shade guides supplied by manufacturers or Vita Lumin shade guide may not provide clinicians a accurate standard in matching color of composite resins, and there are perceptible color differences in most of products. Therefore, it is recommended that custom shade guides be made from resin material itself and used for better color matching.

A Study on the Development of men's Wear in Korea (남성복의 변화에 관한 연구)

  • 이순홍
    • Journal of the Korean Society of Costume
    • /
    • v.29
    • /
    • pp.5-22
    • /
    • 1996
  • the present thesis aims to contribute to the further development of the men's wear indus-try in Korea which now confronts the need to adjust itself more actively to the conditions of the coming age of internationalization and free trade. To achieve this this thesis suggests the trade should provide for the changing domestic needs on theone hand and refine its wares as high value-added products in compe-tition with those from the advanced countries in fashion industry on the other, The history of the 'suit' the standard men's attire dates back to 1850 when the 'Ditto suit' was introduced composed of coat waist coat vest and trousers to remain virtually unchanged till the end of the nineteenth cen-tury and the modern men's wear originated in Britain. In Korea since the introduction of western clothes from 1876 custom-made suits had been dominant until 1944 while western clothes earned popular currency between 1945 and 1964 and ready-made suits began to spread with their advantages recognized in terms of practicality convenience and functionality The next phase from 1965 to 1985 witnessed the establishment of a number of ready-made brands although custom-made suits stayed in their height of prosperity until 1975. The turn-ing point for the men's wear industry came in 1975 when high-calss ready-made brands be-gan to turn up with the arrival of large companies in the market matching the change in consumers' life style. The men's wear market went through further diversification and specialization dur-ing the years between 1985. and 1990. Around the year 1990 however the expansion of the business suit industry came to slow down ac-companied by an oversupplied market. The fashion of pragmatism in the 1990s called for the growth of the casual wear department and as consumers' life style became more and more individualized conscious dressing in accord ance with T.P.O established itself as an important branch of culture, Such casual boom is likely to aid in promoting Korea's men's wear indus-try to peer with that of advanced countries. Consumers' fashion sense is now ahead of the trade's as well as being shortcycled highly individualized stylized and diversified. To meet consumers' demands under such circum-stances each company is required to develop its unique soft Know How based on accurate information and strategically specialized plan-ning. The trade should convert its hithero producer-oriented strategy to a new consumer oriented one and actively lead the needs and purchasin g pattern of consumers by providing an efficient and reasonable price policy with optimum supply of merchandise and also by presenting 'our' trend suited to our circum-stances.

  • PDF

Packing Industry Realize Plan of Gwang Yang Bay (광양만권의 패키징산업화 구현 방안)

  • Park, Hong-Gyun
    • Journal of Korea Port Economic Association
    • /
    • v.21 no.4
    • /
    • pp.103-119
    • /
    • 2005
  • For the selection of attraction industry of foreign investment in the free trade zone of Gwang Yang Bay, an overall consideration should be made considering aspects such as the industry development strategy of Gwang Yang Bay and the regional industry development strategy of the local government. For Gwang Yang Bay to grown into the E-Hub Port of Northeast Asia, the development of the back zone of should be accelerated. There is a need to offer custom made incentives for the core businesses. Packaging is a field of combined science and a future industry. Packaging industry, which has close association with regional industry and regional college's research human resources, should be combined with design and set up a packaging industry complex.

  • PDF

Older Women Breast Cancer Survivors: Decision Making, Sources of Information and Wellness Activities in Malaysia

  • Mohamed, Nor Aini;Muhamad, Mazanah
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.3
    • /
    • pp.2043-2048
    • /
    • 2013
  • The purpose of this study mas to profile older breast cancer survivors in Malaysia. In a survey study, a custom made questionnaire was administered to 69 breast cancer patients and survivors between 60 and 84 years of age in Peninsular Malaysia. The main ethnic group recorded was Chinese, followed by Malay and Indian. The majority of women were married (87%) and had children (84.1%). Just over half (53.6%) had primary and secondary education, whereas 24.7% had higher education. Fifty five percent of the study participants made their own decision on treatment, 60.8% exercised at least 3 times in a week, and 56.6% sought information from specialists. Our study suggests that older breast cancer survivors are aware of the importance of exercise in their daily lives and make attempts to be cancer free (e.g. doing exercise, recreational activity and have good relationships with friends and family).

An in-vitro evaluation of sealer placement methods in simulated root canal extensions

  • Kim, Sung-Young;Lee, Se-Jun;Lee, Kwang-Won
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.579-579
    • /
    • 2003
  • I. Objectives The aim of this study was to evaluate and compare the effectiveness of sealer placement in simulated root canal extensions using the K file, ultrasonic file, lentulo spiral and EZ-Fill. II. Materials and Methods Forty resin blocks were attained from cutting Endo-training Bloc with diamond saw. In each parallelepiped block, the simulated root canal was made with #20, 08taper GT file. After each block was longitudinally split into two halves using mallet and chisel, a standardized groove of 4mm in length, located 2mmapart from the root apex, was prepared on one wall of two halves using the custom-made knife to simulate the canal extensions with various irregularities.(omitted)

  • PDF

Evaluation of the initial retention of implant-retained attachments made of dental polyaryletherketones (PAEKs) (Polyaryletherketones (PAEKs)로 제작된 임플란트 유지형 어태치먼트의 유지력 평가)

  • Soo-chul Park;Sung-Min Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.3
    • /
    • pp.61-66
    • /
    • 2023
  • Purpose: The current study examined the retention and wear resistance of stud-type attachments made of high-performance polyetheretherketone (PEEK) or polyetherketoneketone (PEKK) from the polyaryletherketones (PAEKs) family. Methods: The study sample included 10 PEEK or PEKK attachments that were mounted onto their male parts, designed on the upper aspect of the attachment, with a load of 30 N. Tensile stress was applied using an Instron machine to separate the male and female parts, and the maximum tensile stress to be applied was determined based on the retention force observed. The wear resistances of PEEK and PEKK were evaluated by measuring the inner diameter of the inserted female part 10 times. Results: The maximum tensile stresses of PEEK and PEKK were 56.26±0.58 and 69.12±0.92 N, respectively, with the maximum stress required to remove the PEKK specimens from the abutment being 12.86 N higher than that required to remove the PEEK specimens. Furthermore, PEKK exhibited higher wear resistance than PEEK. Conclusion: This study evaluated custom-made removable implant-retained attachment components for overdentures, wherein the female parts were made of PEEK or PEKK. The retention stress and wear resistance were evaluated based on the type of attachment material, and the results showed that both types of attachment inserts demonstrated clinically acceptable results in terms of retention.

Parameter Extraction and Simulation in order to Manufacture Ready-made Ear Shell for CIC Type Hearing Aids (CIC형 보청기용 범용 이어쉘 제작을 위한 파라미터 추출 및 시뮬레이션)

  • U, Erdenebayar.;Jeon, Y.Y.;Park, G.S.;Song, Y.R.;Lee, S.M.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.321-327
    • /
    • 2010
  • Most of the ear shells of hearing aids are manufactured manually, and it is one of the reasons that the cost of the custom-made hearing aids can be increased. Thus it is required to manufacture the ready-made ear shell for the purpose of easy manufacturing and decrease in cost. In this study, we extract parameters in order to manufacture the ready-made ear shell for CIC type hearing aids and simulate to reconstruct the ear shell using the extracted parameters. To parameter extraction, we set up the eleven parameters for the ready-made ear shell based on anatomical characteristics of the ear canal, and we found values of the parameters from twenty-one impressions in their 20s and twelve impressions in their 60s using aperture detection and feature detection algorithms. Classifying the parameters by size, we also determine the parameters of ready-made ear shell into three types for people in their 20s and two types for people in their 60s. Each ready-made ear shell was simulated to reconstruct using figured parameters, and evaluated the rate of agreement with unused impressions for setting parameters. To evaluate the ready-made ear shell, we calculate the volume ratio and intersection between of the each impression and ready-made ear shell, and the intersection ratio using the intersection volume and ready-made ear shell volume. As a result, the volume ratio was about 70%, and volume match ratio was also up to 70%. It means that the ready-made ear shell we simulated is the significantly matched to impression.

THE CHANGE OF THE INITIAL DYNAMIC VISCO-ELASTIC MODULUS OF COMPOSITE RESINS DURING LIGHT POLYMERIZATION (광중합 복합레진의 중합초기 동적 점탄성의 변화)

  • Kim, Min-Ho;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.450-459
    • /
    • 2009
  • The aim of this study was to measure the initial dynamic modulus changes of light cured composites using a custom made rheometer. The custom made rheometer consisted of 3 parts: (1) a measurement unit of parallel plates made of glass rods, (2) an oscillating shear strain generator with a DC motor and a crank mechanism, (3) a stress measurement device using an electromagnetic torque sensor. This instrument could measure a maximum torque of 2Ncm, and the switch of the light-curing unit was synchronized with the rheometer. Six commercial composite resins [Z-100 (Z1), Z-250 (Z2), Z-350 (Z3), DenFil (DF), Tetric Ceram (TC), and Clearfil AP-X (CF)] were investigated. A dynamic oscillating shear test was undertaken with the rheometer. A certain volume ($14.2\;mm^3$) of composite was loaded between the parallel plates, which were made of glass rods (3 mm in diameter). An oscillating shear strain with a frequency of 6 Hz and amplitude of 0.00579 rad was applied to the specimen and the resultant stress was measured. Data acquisition started simultaneously with light curing, and the changes in visco-elasticity of composites were recorded for 10 seconds. The measurements were repeated 5 times for each composite at $25{\pm}0.5^{\circ}C$. Complex shear modulus G*, storage shear modulus G', loss shear modulus G" were calculated from the measured strain-stress curves. Time to reach the complex modulus G* of 10 MPa was determined. The G* and time to reach the G* of 10 MPa of composites were analyzed with One-way ANOVA and Tukey's test ($\alpha$ = 0.05). The results were as follows. 1. The custom made rheometer in this study reliably measured the initial visco-elastic modulus changes of composites during 10 seconds of light curing. 2. In all composites, the development of complex shear modulus G* had a latent period for $1{\sim}2$ seconds immediately after the start of light curing, and then increased rapidly during 10 seconds. 3. In all composites, the storage shear modulus G" increased steeper than the loss shear modulus G" during 10 seconds of light curing. 4. The complex shear modulus of Z1 was the highest, followed by CF, Z2, Z3, TC and DF the lowest. 5. Z1 was the fastest and DF was the slowest in the time to reach the complex shear modulus of 10 MPa.