• Title/Summary/Keyword: cushion

Search Result 363, Processing Time 0.024 seconds

Implementation of Real-time Sedentary Posture Correction Cushion Using Capacitive Pressure Sensor Based on Conductive Textile

  • Kim, HoonKi;Park, HyungSoo;Oh, JiWon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.2
    • /
    • pp.153-161
    • /
    • 2022
  • Physical activities are decreasing and sitting time is increasing due to the automation, smartization, and intelligence of necessary household items throughout daily life. Recent healthcare studies have reported that the likelihood of obesity, diabetes, cardiovascular disease, and early death increases in proportion to sitting time. In this paper, we develop a sitting posture correction cushion in real time using capacitive pressure sensor based on conductive textile. It develops a pressure sensor using conductive textile, a key component of the posture correction cushion, and develops a low power-based pressure measurement circuit. It provides a function to transmit sensor values measured in real time to smartphones using BLE short-range wireless communication on the posture correction cushion, and develops a mobile application to check the condition of the sitting posture through these sensor values. In the mobile app, you can visualize your sitting posture and check it in real time, and if you keep it in the wrong posture for a certain period of time, you can notify it through an alarm. In addition, it is possible to visualize the sitting time and posture accuracy in a graph. Through the correction cushion in this paper, we experiment with how effective it is to correct the user's posture by recognizing the user's sitting posture, and present differentiation and excellence compared to other product.

A Comparative Study on the Retention of Implant Overdenture According to the Shape and the Number of Magnetic Attachment (자성 어태치먼트의 형태와 수에 따른 하악 임플란트 피개의치의 유지력에 대한 비교 연구)

  • Seo, Min-Ji;Lee, Joon-Seok;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.169-181
    • /
    • 2008
  • The aim of this study was to compare the retention and stability of implant overdenture according to the shape and the number of magnetic attachment. The experimental groups were designed for the number of implants(1, 2, 4) and shape of magnetic attachments(flat, cushion, dome type) resulting in 9 subgroups. 45 attachments were tested attached to $Br{\aa}nemark$ system implants which were planted on a mandibular model. Each attachment was composed of the magnet assembly embedded in a overdenture sample and the abutment keeper screwed into the implants. Dislodging tensile forces were applied to the overdenture samples using an Instron(cross-head speed 50.80mm/min) in 3 directions simulating function: vertical, oblique, and anterior-posterior. The loading was repeated 10 times in each direction for 45 samples. The values of maximum dislodging force of each subgroup were processed statistically using SPSS V. 12.0 at the 0.05 level of significance. The results of this study were as follows: 1. Flat type magnetic overdenture was the most retentive when subjected to vertically directed forces and dome type was the lest retentive when subjected to obliquely directed forces(p<0.05). 2. In case of planting one implant, flat type had a higher vertically retentive force than anterior-posteriorly retentive force. In case of planting two implants, flat type and dome type had a higher vertically retentive force and in case of planting four implants, flat type and cushion type had a higher vertically retentive force than anterior-posteriorly retentive force(p<0.05). 3. The incremental number of dental implant, without regards to the three types of magnetic attachment shapes, showed higher retention of overdenture(p<0.05). From the results, if a patient need much more retention of implant overdenture, flat type magnetic overdenture would be a good treatment. In case of the bruxism where excessive lateral forces are already present, dome type could be expected to produce better results. In case of planting one implant, flat type is more stable than the other shape of magnet and in case of two implant, flat type and dome type are more stable and in case of four implants, flat type and cushion type are more stable. Planting more than two implants and using flat type magnetic attachment would provide better retention and stability of implant overdenture

A Simulation Study on the Analysis of Optimal Gas Storage System of the Depleted Gas Reservoir (고갈가스전에의 적정 가스저장시스템 분석을 위한 시뮬레이션 연구)

  • Lee, Youngsoo;Choi, Haewon;Lee, Jeonghwan;Han, Jeongmin;Ryou, Sangsoo;Roh, Jeongyong;Sung, Wonmo
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.515-522
    • /
    • 2007
  • In this study we have attempted to evaluate the technical feasibility of "BB-HY", which is depleted gas reservoir as a gas storage field, using the commercial compositional simulator "ECLIPSE 300". The "BB-HY" reservoir has an initial gas in place of 143 BCF which is relatively small, and its porosity and permeability are 19.5% and 50 md, respectively. For "BB-HY" gas reservoir, we have performed a feasibility analysis by investigating the cushion gas (or working gas), converting time to gas storage field, operation cycle, number of wells and the possible application of horizontal borehole as well. From the simulation results, it was found that the amount of cushion gas in "BB-HY" reservoir is required at least 50% of IGIP in order to operate stably as gas storage field. When one produces gas for longer time and hence the remaining gas in reservoir is less than optimal cushion gas, no technical problem was occurred as long as additional cushion gas is injected up to the optimal cushion gas. In the case of changing the operation cycle into producing gas for three months during winter season from producing five months, the result shows that either the cushion gas should be greater than 60% or the more number of wells should be drilled. Meanwhile, from the results of sensitivity analysis for the number of wells, in cases of operating six or eight vertical wells, the stable reproduction of the injected gas can not be possible in "BB-HY" gas reservoir since the remaining gas in reservoir is increased. Therefore, in "BB-HY" reservoir, at least ten vertical wells should be drilled for the stable operation of gas. This time, when three horizontal wells are additionally drilled including the existing two vertical wells, it was found that the operation of injection and reproduction of gas is relatively stable in "BB-HY" gas reservoir.

Numerical Study on Flexible Forming Process for Sheet Metal (박판용 가변성형공정의 수치적 연구)

  • Heo, S.C.;Seo, Y.H.;Park, J.W.;Ku, T.W.;Song, W.J.;Kim, J.;Kang, B.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.281-284
    • /
    • 2009
  • Flexible forming process for sheet metal using reconfigurable die is introduced based on numerical simulation. Numerical simulation of sheet metal forming process is carried out by using flexible dies model instead of conventional matched die set. Elastic cushion which has high resilience behavior from excessive deformation are inserted between forming punches and blank material for smoothing the forming surface which has discrete due to characteristics of the flexile die. As an elastic cushion, urethane pads are utilized using hyperelastic material model in the simulation. Formability in view of surface defect such as onset of dimple is compared with regard to various punch sizes. Consequently, it is confirmed that the flexible forming process for sheet material has appropriate capability and feasibility for manufacturing of smoothly curved surface instead of conventional die forming process.

  • PDF

Sitting Posture Information Services through Smart Cushion (스마트 방석을 통한 앉은 자세 정보 서비스)

  • Lee, Mi-hee;Kim, Seonhong;Kim, Hayeong;Byeon, Eonyeong
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2016.07a
    • /
    • pp.217-218
    • /
    • 2016
  • 본 논문에서는 매년 증가하고 있는 청소년 허리질환의 문제를 해결하고자 가성비가 높은 스마트 방석을 개발하였다. 스마트 방석은 일반 방석에 압력센서 4개를 장착하고 앉은 사람의 자세를 모니터링하여 스마트폰과 PC를 통해 실시간 또는 통계적으로 분석해 준다. 이는 사용자로 하여금 경각심을 갖도록 유도하며 좌, 우측별 불균형한 자세를 교정하도록 하는 효과를 얻을 수 있다.

  • PDF

Automotive Seat Vibration Control with a Nonlinear Seat Cushion Model (비선형 시트 쿠션 모델을 고려한 자동차 시트의 진동 제어)

  • Mo, Chang-Ki
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.3
    • /
    • pp.261-266
    • /
    • 2003
  • 이 논문에서는 반능동 진동 흡수기를 통합 시트/섀시 현가 장치에 확대, 적용하여 그 성능을 조사하였다. 통함 현가시스템의 성능분석을 위해 집중 인체질량과 함께 실험적으로 입증된 한 비선형 시트 쿠션 모델을 도입하였다. 또한 3 자유도 시트/섀시 현가시스템의 효과적인 진동제어를 위해 리아푸노브 바이스테이트 제어법칙을 사용하였다. 시뮬레이션결과 반능동 통합 현가장치는 시트 쿠션 모델과 관계없이 운전자의 승차감과 관련 있는 시트의 절대가속도 크기와 시트쿠션의 시트 트랙에 대한 상대변위를 상당히 감소시킬 수 있음을 알 수 있었다. 그러나, 주로 사용되어온 선형 쿠션 모델을 사용한 경우보다 비선형쿠션 모델을 사용한 경우의 제진성능이 약간 저조함을 알 수 있었다. 따라서, 자동차 시트 설계시 성능분석을 위해서는 실제의(비선형의) 시트 쿠션 특성을 적용해야 함을 알 수 있다.

  • PDF

A Study on the Cushion Package Design of a Monitor using Finite Element Method (유한요소법을 이용한 모니터의 완충 포장재 설계에 관한 연구)

  • H.B.L.;Park, Sang-Hu;Kim, Won-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.12
    • /
    • pp.88-93
    • /
    • 2000
  • The reduction of the cushion material such as Expanded Polystyrene (EPS) is one of the urgent tasks of the package design process in home electrical appliances considering environmental protection. EPS reduction often causes the structural damage of products, which must be protected in the environment of transportation. CAE simulation can help the efficient package design with low material cost. The mechanical drop simulation of packaged product was performed with commercial FEM code and Taguchi approach was used partially to determine the dominant design parameters. As results of this study, about 20% reduction of EPS was accomplished in the monitor package design.

  • PDF

Clinical study of Endocardial Cushion Defect [7 Cases Report] (심내막상 결손증의 임상적 고찰7례 보고)

  • 김승철
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.283-287
    • /
    • 1985
  • Seven patients had undergone repair of endocardial cushion defect from Jan. 1977 to Dec. 1984 at National Medical Center. Most patients had no associated anomalies except one who had PFO, and mortality case was absent. Five patients had partial ECD and two had complete ECD [Rastelli type A]. In P-ECD patients, the atrial septal defect was closed with patch in all cases and mitral cleft was approximated with 2-3 direct stitches. In two cases of C-ECD, atrial and ventricular septal defect was closed with single patch in one case and atrial septal defect was closed with patch but ventricular septal defect was closed with patch but ventricular septal defect was closed it direct suture in the other case. Atrioventricular cleft was approximated with 2-3 direct sutures. Postop. transient A-V block was noted in 2 cases but returned to regular sinus rhythm after 2 to 6 months.

  • PDF