• 제목/요약/키워드: curtain-wall

검색결과 239건 처리시간 0.03초

건설사업장의 날림먼지 및 소음 저감 기술 적용사례 비교분석 (Comparative Study on the Control Technologies of Fugitive Dusts and Noise of Construction Project in Korea)

  • 구자건;강미연;서용칠
    • KIEAE Journal
    • /
    • 제9권1호
    • /
    • pp.55-60
    • /
    • 2009
  • This study was carried out to propose the optimum technologies that can be applicable to noise and fugitive dust controlling in construction sites by comparative analysis in cases. The ninety three environmental management technologies applied to fifty-five construction projects conducted during 2005~2007 in Korea were analyzed by checklist method. The construction companies paid more attention to the noise and fugitive dust controlling technologies than the waste and wastewater. The diverse pollution controlling techniques were applied to the architectural projects than the civil projects to meet the environmental requirements in residential area. The fugitive dust controlling technologies(75.3%) were more widely applied to all construction projects than the noise controlling technologies(24.7%). As the noise controlling techniques, the noise barriers in wall-form which are set up as boundary in construction site were more widely used than the noise barriers in curtain-form, in cabin and silencers. Water spraying systems, wind barriers and mechanical sweepers were the preferred technologies for controlling fugitive dust emission.

흑염소 축사시설에 관한 실태조사 연구 (A Study of Investigation the Actual conditions on Housing and Facilities for Korean Native Goat)

  • 최순호;정광화;조영무;강희설;김원호;김영근
    • 한국축산시설환경학회지
    • /
    • 제7권1호
    • /
    • pp.13-20
    • /
    • 2001
  • This study was conducted to investigate the actual conditions on housing and facilities for goat. This investigation of the actual conditions was investigated by the style of farm which was divided into sideline scale and speciality scale included 47 farms. The results are summarized as follows: Rearing scale was 48.9% for 50-100 heads per farm. Rearing type was 46.8% for grazing type and 53.2% for barn type. Housing type was 27.7% for simple frame housing and 72.3% for permanent housing. Pipe was used 80.8% with Pillar and Girder as the housing frame at farm. For the pipe used in farm, 27.7% of them was used for simple frame housing. Side wall was composed of cement and winch curtain to be 29.8%, slate roof to be 40.4%, pipe partition to be 38.3%, and cement floor to be 51.1%. Materials of feeding trough were wood and Zinc grater to be 41.5%, respectively. Type of feeding trough was square to be 70.2%. The feeding trough was located in barn to be 48.9%. Material of water supply facilities was plastic to be 87.2%. Type of water supply facilities was mostly square to be 76.6%. Water-trough was located in playground to be 48.9%. Parturition facilities were consisted of partition structure by group to be 42.5% and were mainly composed of pipe and wood. 46.8% of the barn did not have delivery room in the farm.

  • PDF

국내 건축용 유리 및 커튼월의 안전 기준 개선 방향에 관한 연구(II) (The Approach Methods of Improvement of Safety Standard for Architectural Glass and Curtain Wall)

  • 서윤정;서동구;신이철;김동은;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 추계학술발표회 자료집
    • /
    • pp.25-28
    • /
    • 2010
  • 최근 건축물의 초고층화에 따른 커튼월 시공에 따라 유리의 비중이 증가하고 있으나 커튼월 구조는 바람, 지진, 화재에 있어서 취약할 것이라 판단되어 국내외 건축용 유리 및 커튼월의 안전기준에 대한 조사를 실시하였다. 그 결과, 국내의 유리 기준은 단열 및 내풍압 성능에만 집중되어있으며 화재 및 지진, 안전 성능에 대한 기준이 미비한 실정이다. 따라서 국내에 적합한 유리 안전성 평가 프로세스를 구축하기 위한 기초 데이터를 마련하기 위해 유리 내화 실험을 시행하였다. 실험 결과, 일반유리, 복층유리, 강화유리, 접합유리 순의 파열 시간을 가지는 것을 알 수 있었으나 시험체 4개가 화재 초기에 파열되는 것으로 나타나 상층부로의 수직 화재 확대 위험성이 높을 것으로 판단된다.

  • PDF

2015년 메르스 사태 이후 신축된 종합병원 병동부의 공간구성 특징 및 입원실 세부시설기준에 관한 연구 (A Study of the Spatial Composition and the Facility Criteria of In-patient Rooms in General Hospitals after MERS 2015)

  • 이현진;권순정
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권2호
    • /
    • pp.27-35
    • /
    • 2019
  • Purpose: This study is to address the spacial composition of a standard ward and bedroom size for sake of infection control and efficient medical service. Methods: Spacial composition of a standard ward has been proposed by comparative analysis of 5 big hospitals' wards. Bedroom sizes have been explored on the ground of Health care facility regulations from Korea, USA, Australia and Canada. Of course, Literature and field survey have been conducted in order to draw out various bedroom sizes. Results: 16 basic and some other additional spaces have been proposed for the composition of hospital standard ward. Area of Single bedroom is $11.6m^2$, and that of multi-beded room is $7.4m^2$. Bed to bed Clearance is 1.5m, spacing between bedsize and hard wall is 0.9m in 1~2 beded room, 0.75m in 4-beded room. Space clearance between Foot side of bed and curtain is proposed as 0.3m and additional 0.9m is necessary for the circulation. Implications: The result of this study can be applied to the new cons.

3D 프린팅을 활용한 스마트노드 시스템의 적용 사례 (A Case Study of Smart Node System by using 3D Printing Technology)

  • 나상호;이장현;박영미;김성진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.6-7
    • /
    • 2021
  • 3D printing has the unique advantage of the ability to customize freeform products even in small quantities. It was recently applied successfully in the node connection system for the irregular shaped glass design of Gwanggyo Galleria Department Store. This was achieved by applying 3D printing technology for an innovative smart node design. The novel system offers flexibility to address various design challenges in addition to maximizing construction quality and reducing construction period. In this paper, we aim to examine the use of 3D printing based innovative technologies in the construction industry. With this aim in mind, we present the case of the Gwanggyo Galleria Department Store's smart nodes. The key objective of this study is creating awareness in the construction industry of the need to utilize fourth industrial revolution technology in architecture.

  • PDF

Exploring Effective BIM Workflow Among Practitioners by Technology Acceptance Model: A Case Study on the Construction of Facade

  • Guo, Jingjing;Yang, Jinze;Peng, Senlin;Mao, Chao
    • 국제학술발표논문집
    • /
    • The 7th International Conference on Construction Engineering and Project Management Summit Forum on Sustainable Construction and Management
    • /
    • pp.201-209
    • /
    • 2017
  • Facade structure system plays an important role in modern architecture and design. Many contractors start using Building Information Modeling (BIM) to help design and lay-out façade walls in recent years. However, there are still some users refuse to accept BIM on façade construction. Therefore, we employed Technology Acceptance Model (TAM) to assess the users acceptable of BIM work flow, with using a practical case of facade construction in Chongqing Wanda City. The factors that will affect the builder's decision of whether using BIM or not when construct façade, and the relationship among them will be found via this model. Through the analysis using TAM, this research found that the direct factors influencing the completely acceptance of BIM in façade construction is the BIM quality and Result Demonstrating, and the parameter impacting the intuition engendering is the Exterior Condition. Therefore, this paper proposes a more systemic model of BIM acceptance in curtain wall to analyze the user's acceptance. The solution can also offer a reference for future research and construct on façade structure. The acceptance model has the significance that it can help to analyze the reason why users refuse to use BIM in façade construction, thus to help users accept BIM.

  • PDF

양돈농가의 사육규모별 축사시설 분석 (Surveying for Pig House Facilities of Pig Farms by Holding Scale)

  • 서광욱;민병로;최희철;이대원
    • 한국축산시설환경학회지
    • /
    • 제15권3호
    • /
    • pp.231-240
    • /
    • 2009
  • 본 연구는 우리나라 양돈농가의 사육규모별 양돈시설 현황을 파악하고자 전국 9개도의 돼지 1,000두 이상 사육농가 3,029호를 대상으로 돈사시설 실태를 조사하였으며 결과는 다음과 같다. 1,000두 이상을 사육하는 전업농가에서 7,229,892 마리를 사육하였으며 농가당 평균 사육두수는 2,386.9두 이었다. 돈사의 건축 시기는 평균 건축연도가 1995. 8월로 노후한 돈사가 많았으며 농가당 돈사면적은 $3,017.2\;m^2$이었다. 돈사의 건축형태는 윈치커튼돈사가 77.2%로 무창돈사 51.3%, 톱밥돈사 7.4, 고상식 4.6% 보다 많았으며 1,000~1,999두 사육 농가는 윈치커튼돈사가 80.6%로 무창돈사 43.6% 보다 많았으나 10,000두 이상의 대규모 농가는 무창돈사가 75.5%로 윈치커튼 돈사 56.6% 보다 많았다. 분뇨수거 형태는 슬러리 돈사가 72.3%로 스크레이퍼 돈사 38.5% 보다 많았으며 1,000~1,999두 사육농가의 슬러리돈사 72.3%에 비하여 10,000두 이상 사육농가는 슬러리가 83.3%로 대규모 농가에서 더 많았다. 지붕재질은 슬레이트 51.2%, 판넬 46.1%로 슬레이트가 많았으나 10,000 이상 사육농가는 슬레이트가 25.0%로 중소규모 농가에 비하여 낮은 비율을 보였다. 돈사의 외벽체는 판넬이 41.9%로 가장 많았으며 블록 21.9%, 콘크리트 7.6%, 윈치커튼 6.3%, 벽돌 5.9% 이었다. 돈사의 환기방식은 자연환기 46.1%, 기계식 무창 44.1%, 자연환기+기계식 혼합형 53.1%로 자연환기보다는 기계식환기를 하는 농가가 많았다. 특히 규모가 클수록 기계식 무창의 비율은 69.8%로 소규모농가의 36.1%에 비하여 많았다. 돈사 시설의 사용년수는 급이라인 8.1년, 급수라인 8.3년, 전기시설 8.2년, 바닥재 9.0년으로 대부분 8년 이상 사용한 것으로 나타났다.

  • PDF

용담댐 저수지 수질관리시스템 적용성 평가 (Assessment of Water Quality Management System Application on Yongdam Reservoir)

  • 이요상;고덕구;이혜숙;정선아
    • 환경영향평가
    • /
    • 제17권4호
    • /
    • pp.235-242
    • /
    • 2008
  • To develop a watershed management plan for protection of the lake water quality, the linkages among land use activities, stream water quality, and lake water quality must be understood. This study conducted to develop a Decision Support System(DSS) for the reservoir water quality managers and a comprehensive watershed management plan. This DSS has three main components; database, interactive decision model, and data delivery interface system. Graphic User Interface(GUI) was developed as the interface medium to deliver the data and modeling results to the end users. Water quality management scenarios in Yongdam reservoir consist of two parts. One is the watershed management, and the other is water quality management in the reservoir. The watershed management scenarios that were evaluated include as follows : a removal of point sources, control of waste water treatment plant, reductions in nonpoint sources, and the management of developed land. Water quality management scenarios in the reservoir include to install a curtain wall and to operate an algae removal system. The results from the scenario analysis indicate that the strategy of the reservoir water quality management can promise the best effectiveness to conserve the quality of reservoir water. It is expected that many local agencies can use this DSS to analyze the impact of landuse changes and activities on the reservoir watershed and can benefit from making watershed management decisions.

타워팰리스 III 현장의 첨단 시공 및 엔지니어링 기술 적용사례 (Applied cases of advanced construction & engineering technology at Tower Palace III Project)

  • 왕인수
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2003년도 학술대회지
    • /
    • pp.202-213
    • /
    • 2003
  • 타워팰리스 III 현장은 현존하는 국내 건축물로는 가장 높은 초고층 주상복합건물이다. 초고층 현장에는 일반현장과는 다른 시공기술 및 엔지니어링 기술의 적용이 요구되는 바, 타워팰리스 III 현장은 지금까지 축적된 기술을 바탕으로 보다 발전된 시공기술과 엔지니어링 기술, 그리고 공정관리기법을 통하여 마감공사 포함 충 당 13.4일이라는 공사 속도를 달성하였다. 이와 같은 공사를 성공적으로 수행하기 위하여 적용된 첨단 시공기술로 1) 골조공사 및 외벽공사의 3-Day Cycle을 달성하기 위한 여러 가지 공법, 2) 초고층 주거건물의 마감공사 공정관리를 위한 Tact 공정관리 시스템, 3) 현장관리 시스템으로 물류관리 및 정보공유 시스템 등이 적용되었다. 또한 엔지니어링 요소기술로 1) 고유동 무다짐 콘크리트와 국내 최초의 압축강도 $800kgf/cm^{2}$의 초고강도 콘크리트 등의 New Material, 2) 냉각수 순환형 파이프쿨링 시스템 등의 New Method, 3) Smart Fan Control 주방환기 시스템을 포함한 Mechanical System 4) False Car System을 포함한 Electrical System 등이 있다.

  • PDF

지역 건축물의 에너지 자립을 위한 패시브 외단열 복합패널 개발 연구 (Development of the Passive Outside Insulation Composite Panel for Energy Self-Sufficiency of Building in the Region)

  • 문선욱
    • 한국농촌건축학회논문집
    • /
    • 제20권1호
    • /
    • pp.11-18
    • /
    • 2018
  • The study aims to address the energy crisis and realize self-sufficiency of building as part of local energy independence, breaking away from a single concentrated energy supply system. It is intended to develop modules of the outside insulation composite panels that conform to passive certification criteria and for site-assembly systematization. The method of study first identifies trends and passive house in literature and advanced research. Second, the target performance for development is set, and the structural material is selected and designed to simulate performance. Third, a test specimen of the passive outside insulation curtain wall module designed is manufactured and constructed to test its heat transmission coefficient, condensation performance and airtightness. Finally, analyze performance test results, and explore and propose ways to improve the estimation and improvement of incomplete causes to achieve the goal. The final test results achieved the target performance of condensation and airtightness, and the heat transmission coefficient was $0.16W/(m^2{\cdot}K)$, which is $0.01W/(m^2{\cdot})K$ below the performance target. As for the lack of performance, we saw a need for a complementary design to account for simulation errors. It also provided an opportunity to recognize that insulated walls with performance can impact performance at small break. Thus, to be commercialized into a product with the need for improvement in the design of the joint parts, a management system is needed to increase the precision in the fabrication process.