수막하우스의 유량 및 수온에 따른 열전달 특성 분석 (Analysis of Heat Transfer Characteristics in Response to Water Flow Rate and Temperature in Greenhouses with Water Curtain System)

  • 김형권;김승희;권진경
    • 생물환경조절학회지
    • /
    • 제25권4호
    • /
    • pp.270-276
    • /
    • 2016
  • This study analysed overall heat transfer coefficient, heat transmission, and rate of indoor air heating provided by water curtain in order to determine the heat transfer characteristic of double-layered greenhouse equipped with a water curtain system. The air temperatures between the inner and outer layers were determined by the water flow rate and inlet water temperature. Higher water flow rate and inlet water temperature resulted in the increased overall heat transfer coefficient between indoor greenhouse air and water curtain. However, it was found that with higher levels of water flow rate and inlet water temperature, indoor overall heat transfer coefficient was converged about $10W{\cdot}m^{-2}{\cdot}^oC^{-1}$. The low correlation of overall heat transfer coefficient between water curtain and air within double layers was likely because the combination of greenhouse shape, wind speed and outdoor air temperature as well as water curtain affected the heat transfer characteristics. As water flow rate and inlet water temperature increased, the heat transferred into the greenhouse by water curtain also tend to rise. However it was demonstrated that the rate of heat transmission from water curtain into greenhouse with water curtain system using underground water was accounted for 22% to 28% for total heat lost by water curtain. The results of this study which quantify heat transfer coefficient and net heat transfer from water curtain may be a good reference for economical design of water curtain system.

유도공기 및 에어커튼을 이용한 주방 레인지후드 성능 개선에 관한 수치모사 (A Numerical Study on the Performance Improvement of Kitchen Range Hood by Air Induction and Air Curtain)

  • 손덕영;임지홍;최윤호;박재훈
    • 설비공학논문집
    • /
    • 제19권4호
    • /
    • pp.321-327
    • /
    • 2007
  • In an apartment house that is generally air-tight and well insulated, the combustion gas from cooking devices is the major source of air pollution in the kitchen. It spreads throughout the house affecting the overall Indoor all quality. In this study, the performance of the kitchen range hood which employs air induction and air curtain was investigated by numerical simulation. The results are compared with that of two other kitchen range hoods which are in general use. The two general types of range hoods considered in the present calculations are box and plate type range hoods. The former has a large capture space between the filter and suction duct, while the latter has little. It was found that the capture efficiency of the kitchen range hood with air induction and air curtain Is higher than that of the general types of range hoods by 20% approximately The reason may be because the air induction and the air curtain block the air stream escaping from the front and the side part of range hoods effectively and because an additional fan for air induction and air curtain increases suction flow rates.

고속도로 요금소 부스 근무환경 개선을 위한 기류해석 연구 (A Study on Numerical Simulation for the Work Environment Improvement of Highway Tollgate Booth)

  • 김신도
    • 한국대기환경학회지
    • /
    • 제16권2호
    • /
    • pp.129-140
    • /
    • 2000
  • Simulation study has been carried out to analyze the air flow supplying from the heat pump system inside the tollgate booth by using the Phoenix computer simulation program. Through this simulation analysis we can find the problem of present tollgate booth in terms of air flow and recommend an improved model also simulate this model. Final results as follows; It was turned out that the fresh air conditioning is not provided to the worker effectively due to the improper location of inlet and outlet in the present tollgate booth in addition to that the air curtain system applied in the booth lowered air circulation from outside. The improved model was suggested first to increase the air curtain effect by downsizing the window and by installation of the air curtain suction line to reduce the induced outdoor air second to supply the fresh air to the worker directly by relocation of the inlet and outlet of supplying air. With these improved modifications better results have been reached in terms of air flow inside the booth. Next through the air flow simulation of outside booth the contaminated outdoor air has been easuily infiltrating into the booth through the window because of its rectangle shape. Stream like shape of booth has been proposed through the computer simulation as an alternative shape of tollgate booth for a new design.

  • PDF

터널 화재시 연기확산 차단을 위한 양방향 토출 에어커튼 시스템에 대한 연구 (The Study on the Bi-directional Ejection Air Curtain System for Blocking Smoke Diffusion in case of Tunnel Fire)

  • 양상호;최영석;김정엽;김남구;김경엽
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.43-53
    • /
    • 2014
  • This paper presents a the study on air curtain system of top and bottom bi-directional jet air discharge for blocking the spread of smoke in case of tunnel fire. The five kinds different air curtains of A, B, C, D, and E of models for various performance tested after manufactured. A results of the various performance test obtained the best efficiency from E model air curtain. And optimize the injection angle of the air curtain nozzle through the three-dimensional computational fluid dynamics (CFD) analysis and analyzed the effects of external pressure of tunnel. and also single factor design have been applied. At present, our attention is focused on the velocity distribution(flow width and flow position) of 1.5m on the ground in tunnel. Also, analyzed the influence of draft in the tunnel. Detailed effects of discharge angle of air curtain and velocity at nozzle exit are discussed.

Dynamic PIV 기법을 이용한 커튼에어백 Vent Hole 고속유동 해석 (Dynamic PIV analysis of High-Speed Flow from Vent Holes of Fill-Hose in Curtain type Airbag)

  • 장영길;최용석;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.17-20
    • /
    • 2006
  • Passenger safety is fundamental factor in automobile. Among much equipment for passenger safety, the air bag system is the most fundamental and effective device. Beside of the front air bag system which installed on most of all automobiles, a curtain-type air bag is increasingly adapted in deluxe cars fur protecting passengers from the danger of side clash. Curtain type airbag system consists of inflator housing, fill hose, curtain airbag. Inflator housing is a main part of the curtain-type air bag system for supplying high-pressure gases to deploy the air bag-curtain. Fill hose is a passageway to carry the gases from inflator housing to each part of curtain airbag. Therefore, it is very important to design the vent holes of fill hose for good performance of airbag deployment. But, the flow information from vent holes of fill hose is very limited. In this study, we measured instantaneous velocity fields of a high-speed flow ejecting from the vent holes of fill hose using a dynamic PIV system. From the velocity Held data measured at a high frame-rate, we evaluated the variation of the mass flow rate with time. From the instantaneous velocity fields of flow ejecting from the vent holes in the initial stage, we can see a flow pattern of wavy motion and fluctuation. The flow ejecting from the vent holes was found to have very high velocity fluctuations and the maximum velocity was about 480m/s at 4-vent hole region. From the mass flow rate with time, the accumulated flow of 4-vent hole has occupied about 70% of total flow rate.

  • PDF

재래시장의 화재확산 방지를 위한 수막설비 설치 지침 (The Water Curtain Installation Guideline for Fire Spread Prevention in Market)

  • 최정욱;조성우
    • 설비공학논문집
    • /
    • 제28권7호
    • /
    • pp.269-274
    • /
    • 2016
  • This paper aims to suggest the water curtain installation guideline for prevention of fire spread. The water curtain systems play a role in preventing fire spread which is caused by fire flames and radiation heat release from a fire source. The radiation attenuation ratio is affected by the water droplet size, vertical distance from the nozzle and flow rate. This study suggests the water curtain installation guideline as follows : (1) Investigation of a reference store array (2) Calculation of the number of drencher heads (3) Review of the relationship between droplet size and attenuation factor depending on the height of the drencher head (4) Review of a drencher head array and spray overlapping. The reference traditional market in which a fire compartment is installed using a water curtain can be predicted to have a radiation attenuation ratio of 50%.

Investigation of influence of linear diffuser in the ventilation of operating rooms

  • Keshtkar, Mohammad Mehdi;Nafteh, Maryam
    • Advances in Energy Research
    • /
    • 제4권3호
    • /
    • pp.239-253
    • /
    • 2016
  • Air quality in hospitals has always concerned hospitals' health officials due to its dangerous particles and gases. Because of the importance of air conditioning in the operating room, a system must be embedded in operating rooms to direct the contaminated air outside, and inject fresh filtered air from outside back into the room. In this study, laminar flow air conditioning system is implemented in the operating room by slot linear diffusers and with the help of air curtain. For this, stimulation Computational Fluid Dynamic (CFD) was used due to its efficiency. The aim of the present study was to find a proper solution to overcome the unfavorable factors, namely, contamination, humidity, and also temperature, velocity and pressure inside the room. These factors were implemented with different values and then stimulated through FLUENT software program. Results showed that the aforementioned factors can be overcome using air curtain and slot linear diffusers.

A Study on the Greenhouse Water Curtain System: Heat Transfer Characteristics

  • 손원명;한길영
    • 한국농공학회지
    • /
    • 제32권E호
    • /
    • pp.80-87
    • /
    • 1990
  • Energy balance equations Were developed to describe the heat transfer mechanisms in a double layer plastic greenhouse with a water curtain system. Heat transfer variables were determined by using various temperature data measured in a conventional prototype semicircular cross-section greenhouse over a range of water temperatures and water flow rates. The heat transfer coefficient between flowing water and greenhouse air was independent of water flow rates. But the heat transfer coefficient between water surface and the stagnant air space within the double plastic layer was dependent on water flow rates. Substituting the heat transfer coefficients, determined from the energy balance equations in the heat transfer equations, demonstrated various relationships among ambient air temperature, greenhouse air temperature, water temperature, and water flow rates. The heating benefits were linearly related to not only the inside and outside air temperatures but also to the water temperature. The energy conservation effects of the water curtain system were found even initial water temperatures were considerably lower than the greenhouse setting temperatures. Sensitivity analysis for heat transfer coefficients demonstrated that the heat transfer coefficient between greenhouse air and the stagnant air within the plastic layers was the most significant coefficient in the estimation of heating effects.

  • PDF

Dynamic PIV를 이용한 커튼형 에어백 부품림 장치의 유동해석 (Dynamic PIV analysis of High-Speed Flow Ejected from the Inflator Housing of a Curtain-type Airbag)

  • 장영길;김석;이상준
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.407-408
    • /
    • 2006
  • Passenger safety is one of the most important considerations in the purchase of an automobile. A curtain-type air bag is increasingly adapted in deluxe cars for protecting passengers from the danger of side clash. Inflator housing is a main part of the curtain-type air bag system for supplying high-pressure gases to pump up the air bag-curtain. Although the inflator housing is fundamental in designing a curtain-type air bag system, flow information on the inflator housing is very limited. In this study, we measured instantaneous velocity fields of a high-speed flow ejecting from the inflator housing using a dynamic PIV system. From the velocity field data measured at a high frame-rate, we evaluated the variation of the mass flow rate with time. From the instantaneous velocity fields of flow ejecting from the airbag inflator housing in the initial stage, we can see a flow pattern of broken shock wave front and its downward propagation. The flow ejecting from the inflator housing was found to have large velocity fluctuations and the maximum velocity was about 700m/s. The velocity of high-speed flow was decreased rapidly and the duration of high-speed flow over 400m/s was maintained only to 30ms. After 100ms, there was no perceptible flow.

  • PDF

해저터널 열차 화재 시 구난역 에어커튼 시스템의 성능에 관한 실험 연구 (Experimental study on applicability of Air-Curtain system in train fire at subsea tunnel rescue station)

  • 박병직;신현준;유용호;박진욱;김휘성;김양균
    • 한국터널지하공간학회 논문집
    • /
    • 제20권1호
    • /
    • pp.1-9
    • /
    • 2018
  • 터널 화재는 밀폐된 공간에서 발생하기 때문에 시야 확보가 매우 어려우며, 빠른 속도로 연기가 차오르기 때문에 대형재난사고로 이어질 수 있다. 본 연구에서는 해저터널 열차 화재 시 구난역을 안전하게 사용하기 위하여 에어커튼 및 가압송풍기를 구난역 플랫폼에 설치하고 실물화재실험을 통하여 에어커튼 시스템의 적용성을 확인하였다. 실제 규모의 구난역에 에어커튼 시스템을 설치하였으며, 화원으로 사용한 액체 햅탄이 전소될 때까지 약 2분 동안 실험을 진행하였다. 에어커튼 시스템이 작동한 경우에는 구난역 플랫폼의 온도와 외부의 온도는 약 $160^{\circ}C$ 차이가 발생하였으며, 에어커튼 시스템이 작동한 경우에 구난역 플랫폼 내부의 일산화탄소는 작동하지 않은 경우의 구난역 플랫폼 내부와 비교하여 약 160 ppm 적게 일산화탄소가 측정되었다. 따라서 본 실물화재 실험을 통하여 해저터널 구난역 에어커튼 시스템이 화재로부터 발생한 열기와 유독가스를 차단할 수 있음을 확인하였다.