• Title/Summary/Keyword: current-effect

Search Result 10,222, Processing Time 0.039 seconds

Online Dead Time Effect Compensation Algorithm of PWM Inverter for Motor Drive Using PR Controller

  • Park, Chang-Seok;Jung, Tae-Uk
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1137-1145
    • /
    • 2017
  • This paper proposes the dead time effect compensation algorithm using proportional resonant controller in pulse width modulation inverter of motor drive. To avoid a short circuit in the dc link, the dead time of the switch device is surely required. However, the dead time effect causes the phase current distortions, torque pulsations, and degradations of control performance. To solve these problems, the output current including ripple components on the synchronous reference frame and stationary reference frame are analyzed in detail. As a results, the distorted synchronous d-and q-axis currents contain the 6th, 12th, and the higher harmonic components due to the influence of dead time effect. In this paper, a new dead time effect compensation algorithm using proportional resonant controller is also proposed to reduce the output current harmonics due to the dead time and nonlinear characteristics of the switching devices. The proposed compensation algorithm does not require any additional hardware and the offline experimental measurements. The experimental results are presented to demonstrate the effectiveness of the proposed dead time effect compensation algorithm.

3-D Characterizing Analysis of Buried-Channel MOSFETs (매몰공핍형 MOS 트랜지스터의 3차원 특성 분석)

  • Kim, M. H.
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.162-163
    • /
    • 2000
  • We have observed the short-channel effect, narrow-channel effect and small-geometry effect in terms of a variation of the threshold voltage. For a short-channel effect the threshold voltage was largely determined by the DIBL effect which stimulates more carrier injection in the channel by reducing the potential barrier between the source and channel. The effect becomes more significant for a shorter-channel device. However, the potential, field and current density distributions in the channel along the transverse direction showed a better uniformity for shorter-channel devices under the same voltage conditions. The uniformity of the current density distribution near the drain on the potential minimum point becomes worse with increasing the drain voltage due to the enhanced DIBL effect. This means that considerations for channel-width effect should be given due to the variation of the channel distributions for short-channel devices. For CCDs which are always operated at a pinch-off state the channel uniformity thus becomes significant since they often use a device structure with a channel length of > 4 ${\mu}{\textrm}{m}$ and a very high drain (or diffusion) voltage. (omitted)

  • PDF

Current effects on global motions of a floating platform in waves

  • Shen, Meng;Liu, Yuming
    • Ocean Systems Engineering
    • /
    • v.7 no.2
    • /
    • pp.121-141
    • /
    • 2017
  • The purpose of this paper is to understand and model the slow current (~2 m/s) effects on the global response of a floating offshore platform in waves. A time-domain numerical simulation of full wave-current-body interaction by a quadratic boundary element method (QBEM) is applied to compute the hydrodynamic loads and motions of a floating body under the combined influence of waves and current. The study is performed in the context of linearized potential flow theory that is sufficient in understanding the leading-order current effect on the body motion. The numerical simulations are validated by quantitative comparisons of the hydrodynamic coefficients with the WAMIT prediction for a truncated vertical circular cylinder in the absence of current. It is found from the simulation results that the presence of current leads to a loss of symmetry in flow dynamics for a tension-leg platform (TLP) with symmetric geometry, resulting in the coupling of the heave motion with the surge and pitch motions. Moreover, the presence of current largely affects the wave excitation force and moment as well as the motion of the platform while it has a negligible influence on the added mass and damping coefficients. It is also found that the current effect is strongly correlated with the wavelength but not frequency of the wave field. The global motion of a floating body in the presence of a slow current at relatively small encounter wave frequencies can be satisfactorily approximated by the response of the body in the absence of current at the intrinsic frequency corresponding to the same wavelength as in the presence of current. This finding has a significant implication in the model test of global motions of offshore structures in ocean waves and currents.

Effect of Potassium Formate, Glycine and Oxalic Acid in Sulfate Bath on Trivalent Chromium Deposition Composition and Current Efficiency (Potassium formate, Glycine, Oxalic acid가 황화물계 3가 크롬도금층의 조성과 전류효율에 미치는 영향)

  • Kim, Man;Kim, Dae-Young;Park, Sang-Eon;Kwon, Sik-Chul;Choi, Yong
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.2
    • /
    • pp.86-91
    • /
    • 2004
  • Effect of potassium formate, glycine and oxalic acid in a sulfate solution on the deposit composition and current efficiency of trivalent chromium plating was studied. The trivalent chromium layers prepared by solutions with potassium formate, glycine and oxalic acid contain a few carbon inside. The solutions containing potassium formate, glycine and oxalic acid are relatively stable with pH change. The solution with the potassium formate shows 6-30% current efficiency with current density, whereas, the solutions with oxalic acid and glycine show about 5% current efficiency, respectively. The improved current efficiency is related to enough supply of chromium ions to the electrode due to the increase of pH at the front of electrode.

Effect of Short Circuit Time Ratio and Current Control Pattern on Spatter Generation in $CO_2$ Welding ($CO_2$용접의 스패터 발생에 미치는 단락시간비 및 단락전류 파형제어의 영향)

  • 조상명
    • Journal of Welding and Joining
    • /
    • v.21 no.1
    • /
    • pp.48-53
    • /
    • 2003
  • The object of this study is to examine the effect of short circuit time ratio (SCTR) and current rise delay time (Td) on the spatter generation at low and medium current range in $CO_2$ welding. The spatter was evaluated by the weight generated in the welding of bead-on-plate for 30 seconds (3 times). Td was varied by order of 0, 0.4, 0.8 and 1.2 msec. At each Td, the short circuit time ratio was varied by the output voltage of the welding power source. In the low current range, it was found that the optimum SCTR was 20~25%, and the minimum spatter generation weight was obtained in the case of Td=0.4msec and SCTR=22% even though the remarkable difference was not showed by the application of Td. In the medium current range, it was confirmed that the arc was stable though the SCTR was increased from 20% to 40% by the control of current wave. Spatter generation weight depended on the variation of Td, and the lowest value of spatter generation weight occurred at Td=0.8~1.2msec.

Bluetooth Low-Energy Current Sensor Compensated Using Piecewise Linear Model

  • Shin, Jung-Won
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.283-292
    • /
    • 2020
  • Current sensors that use a Hall element and Hall IC to measure the magnetic fields generated in steel silicon core gaps do not distinguish between direct and alternating currents. Thus, they are primarily used to measure direct current (DC) in industrial equipment. Although such sensors can measure the DC when installed in expensive equipment, ascertaining problems becomes difficult if the equipment is set up in an unexposed space. The control box is only opened during scheduled maintenance or when anomalies occur. Therefore, in this paper, a method is proposed for facilitating the safety management and maintenance of equipment when necessary, instead of waiting for anomalies or scheduled maintenance. A Bluetooth 4.0 low-energy current-sensor system based on near-field communication is used, which compensates for the nonlinearity of the current-sensor output signal using a piecewise linear model. The sensor is controlled using its generic attribute profile. Sensor nodes and cell phones used to check the signals obtained from the sensor at 50-A input currents showed an accuracy of ±1%, exhibiting linearity in all communications within the range of 0 to 50 A, with a stable output voltage for each communication segment.

Iontophoretic Delivery of Vitamine C-2-phosphate from Carbopol Hydrogel (하이드로겔을 이용한 비타민 C-인산염의 이온토포레시스 피부투과)

  • Oh, Seaung-Youl
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.3
    • /
    • pp.159-166
    • /
    • 2007
  • In order to develop an optimum formulation for iontophoretic delivery of vitamine C-2-phosphate (VCP) from Carbopol hydrogel, we have investigated various factors which can affect the iontophoretic flux through skin. Such factors as drug concentration, current density, current profile, current duration, ionic strength, pH and percutaneous enhancers (ethanol, glycerine, propylene glycerol, sorbitol, urea) were studied. Compared to the flux by passive or anodal delivery, the flux by cathodal delivery increased markedly, and thus, only cathodal delivery was used in the rest of the flux experiments. Flux increased linearly as the drug concentration and current density increased. As the duration of current application increased from 30 min to 120 min, flux increased linearly, however the AUC was not directly proportional to the applied amount of current. Flux also increased as the pH increased, possibly due to the increase in ionization of phosphate group. As the ionic strength increased, flux decreased. No significant increase in flux was observed after enhancer application, indicating that the effect of current on flux is dominating over the effect of percutaneous enhancers (P>0.05). These results provide important informations that are needed for optimal formulation of iontophortic delivery for VCP.

Iontophoretic Transport of GHRP-6 (성장호르몬방출펩타이드-6 (GHRP-6)의 경피투과)

  • Choi, Bo-Kyung;Oh, Seaung-Youl
    • Journal of Pharmaceutical Investigation
    • /
    • v.31 no.4
    • /
    • pp.273-279
    • /
    • 2001
  • The purpose of this study is to characterize the iontophoretic transport of growth hormone releasing peptides (GHRP-6) through hairless mouse skin from aqueous solution. The effect of various factors, such as pH, poloarity, current profile, current density, current duration, ionic strength, drug concentration, and enhancer application was studied to obtain basic knowledge on the transport. We have also studied the stability of GHRP-6 in solution with/without current. The donor chamber was filled with phosphate buffer solution containing GHRP-6 and the receptor chamber was filled with phosphate buffer solution (pH 7.4). Ag/AgCl electrode was used for their stability and reversibility. At a predetermined time interval, sampling was made and the concentration of drug was analysed using HPLC system. The results showed that, compared to passive flux, the total amount of drug transported increased markedly by the application of anodal current. Cathodal flux was similar to passive flux. Flux increased with the current density, the duration of current application and drug concentration. The effect of enhancers on the flux was studied using hydrophilic (5% N-methyl pyrrolidone) and hydrophobic (5% propylene glycol monolaurate, 5% oleic acid) enhancers. Application of enhancer also increased the flux.

  • PDF

Effect of Stress on Current-Voltage Characteristics of ZnO Based Ceramics

  • Jung Ju-Yong;Kim Yeong-Cheol;Seo Hwa-Il;Chung Dong-Teak;Kim Young-Jung;Min Joon-Won
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.4 s.13
    • /
    • pp.1-4
    • /
    • 2005
  • The chemical composition and uniaxial compressive stress are varied to observe their effect on the current-voltage characteristics of ZnO based ceramics. The variation of chemical composition produces two kinds of ceramics showing ohmic and nonohmic current-voltage characteristics. The current at a fixed voltage increased with the increase of the compressive stress for both ohmic and nonohmic ceramics. Ceramics showing nonohmic behavior exhibit better reversible return of current-voltage curve when the applied compressive stress is removed from the ceramics than those showing ohmic behavior do. We found an appropriate chemical composition showing linear relation between current and stress at a fixed voltage. The ceramic materials with an appropriate chemical composition can be used as a potential sensing material in pressure sensors.

  • PDF

Effect of Electrolysis Conditions on Hard Chromium Deposition from Trivalent Chromium Bath (경질용 3가 크롬전착에 미치는 전해조건의 영향)

  • Kim, Dae-Young;Park, Sang-Eon;Kim, Man;Kwon, Sik-Chul;Choi, Ju-Won;Choi, Yong
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.2
    • /
    • pp.155-160
    • /
    • 2003
  • The effect of the temperature, current density and deposit time on hard chromium deposition in trivalent chromium bath was investigated. Cathode current efficiency increased with increasing current density. Increasing bath temperature from $20^{\circ}C$ to $50^{\circ}C$, chromium deposits were produced in higher current density and the maximum current efficiency was increased. At the plating conditions of $40^{\circ}C$, $30A/dm\m^2$, the deposition thickness increased in proportion to increasing electrolysis time The rate is$ 90\mu\textrm{m}$/hrs. for 2 hours. Microhardness of chromium deposits increased with increasing bath temperature and decreasing current density, and it was constant with electrolysis time. All of bath conditions, microstructure of chromium deposits has nodular structure with some cracking pattern and nodule size increased with increasing deposit thickness.