• Title/Summary/Keyword: current-effect

Search Result 10,201, Processing Time 0.048 seconds

The harmonic effect analysis about the big capacity load (대용량부하의 고조파 발생으로 인한 타수용가 영향 분석)

  • Park, Yong-Up;Kim, Kil-Sin;Choi, Won-Suc
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.420-421
    • /
    • 2011
  • In generally, the small harmonic current has not influence on the power system because of offset effect. But the bulk harmonic current has not an offset effect, so that influences on the other customer. This paper describes the measurement power quality in the industrial area, and data analysis result. Also this effect has verified by PACAD/EMTDC simulation tool.

  • PDF

The Spatial Characteristics of Stratification in Deukryang Bay, Korea (밀도류 효과에 으히나 득령만의 성층변동 특성)

  • Byung-Gul Lee;Kyu-Dae Cho
    • Journal of Environmental Science International
    • /
    • v.7 no.2
    • /
    • pp.223-232
    • /
    • 1998
  • The spatial characteristics of stratification In Deukryang Bay were studded using observed data and analytical models. From the description of the density structure and its the potential energy anomaly (PEA) from observed data along longitudinal direction (from the mouth to head of the bays, we found that the stratification Intensity could be changed strongly by density current effect during the spring-neap tidal cycle, and depth variation. To find out density current effect for the formation of the stratification In detail, we Implemented a diagnostic approach by using the modified analytical model including density current, tidal current, surface heating and wind stirring. The model allowed for the observed similarities for the whole domain in the bay and increased tidal mixing efficiency value s up to 0.006-0.007 as compared to the results without density current effect. We found that the density current effect was also an important key factor In determining the formation of the spatial distribution of stratification.

  • PDF

Chemical Modification of the Human Ether-a-go-go-related gene (HERG) $K^+$ Current by the Amino-Group Reagent Trinitrobenzene Sulfonic Acid

  • Jo Su-Hyun;Choi Se-Young;Yun Ji-Hyun;Koh Young-Sang;Ho Won-Kyung;Lee Chin-O.
    • Archives of Pharmacal Research
    • /
    • v.29 no.4
    • /
    • pp.310-317
    • /
    • 2006
  • We investigated the effects of trinitrobenzene sulfonic acid (TNBS), an amino-group reagent, on the human ether-a-go-go-related gene (HERG) $K^+$ channels expressed in Xenopus oocytes. TNBS neutralizes the positively charged amino-groups of peptide N-terminal and lysine residues. External application of TNBS at 10 mM for 5 min irreversibly shifted the curves for currents at the end of the pulse and tail currents of HERG to a more negative potential and decreased the maximal amplitude of the $I_{tail}$ curve $(I_{tail,max})$. TNBS had little effect on either the activated current-voltage relationship or the reversal potential of HERG current, indicating that TNBS did not change ion selectivity properties. TNBS shifted the time constant curves of both activation and deactivation of the HERG current to a more hyperpolarized potential; TNBS's effect was greater on channel opening than channel closing. External $H^+$ is known to inhibit HERG current by shifting $V_{1/2}$ to the right and decreasing $I_{tail,max}$. TNBS enhanced the blockade of external $H^+$ by exaggerating the effect of $H^+$ on $I_{tail,max}$, not on $V_{1/2}$. Our data provide evidence for the presence of essential amino-groups that are associated with the normal functioning of the HERG channel and evidence that these groups modify the blocking effect of external $H^+$ on the current.

Effects of Consumer's Individual Value on Product Selection Attribute and Re-purchase Intention : Focused on Consumers Who Had Purchased Kimchi

  • KIM, Hey-Sook;SHIN, Choung-Seob;CHOI, Young-Sim
    • East Asian Journal of Business Economics (EAJBE)
    • /
    • v.8 no.4
    • /
    • pp.1-18
    • /
    • 2020
  • Purpose - The current study attempts to reveal the causal relationship and identify the interrelationships among individual value, product selection attribute, and re-purchase intention of consumers when purchasing kimchi. Research design, data, and methodology - The surveys were distributed and retrieved to kimchi consumers in Seoul and Gyeonggi Province who were over 20 years old and who had purchased kimchi before. The current study utilized the self-reporting survey as the research method. Result - First, as a result of hypothesis 1 test, both internal value and external value had a significant effect. Second, as a result of hypothesis 2 test, while internal value had a significant effect, external value did not have a significant effect. Third, as a result of hypothesis 3 test, while internal value had a significant effect, external value did not have a significant effect. Fourth, as a result of hypothesis 4 test, all quality, brand, and price had a significant effect. Fifth, as a result of hypothesis 5 test, while internal value had a significant effect, external value did not have a significant effect. Conclusion - The current study aims to establish marketing and service strategies to maximize profits and secure competitive advantage in the kimchi industry through changes in the management strategy of the Korean kimchi industry.

Effect of current waveform on drop transfer in pulsed gas metal arc welding (Pulsed GMAW 의 전류 파형이 금속이행에 미치는 영향)

  • Hammad, Muhammad A.;Yoo, Choong-D.
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.48-48
    • /
    • 2009
  • Conventionally in pulsed gas metal arc welding (GMAW-P), drop transfer is analyzed with simplest square pulse waveform. While the pulse current is described by four parameters (peak current magnitude and time plus base current magnitude and time), it deviates the real pulse shape. Real pulse can be better idealized by the trapezoidal pulse waveform described by two additional parameters, i.e., current rise and fall rate (dI/dt). Power source response rate is described by these parameters. In this work, the effect of these parameters on drop transfer is predicted by the force displacement model (FDM). While peak current has significant effects on drop detachment, drop transfer is also influenced by the current rise rate. Predictions indicate that the current rise rate can have considerable effects on the size of the detached drop if other pulse parameters are kept constant. FDM is applied to determine peak time for one drop one pulse condition (ODOP) when rests of the pulse parameters are given. The predicted range of ODOP shows good agreement with experimental data.

  • PDF

Effect of Current Collecting Layer on the Impedance of LSM and LSM-YSZ Cathode (LSM 및 LSM-YSZ 양극의 임피던스 특성에 미치는 집전층의 효과)

  • 문지웅;이홍림;김구대;김재동;이해원
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.10
    • /
    • pp.1070-1077
    • /
    • 1998
  • Effect of current collecting layer on the cathode was characterized by AC impedance spectroscopy at 800$^{\circ}C$ under flowing air. LSM-YSZ composite cathode showed lower polarization resistance due to the in-crease of triple phase (LSM/YSZ/Pore) boundary length by incorporation of YSZ. Ohmic resistance {{{{ {R }_{1 } }} of LSM-YSZ was higher than that of pure LSM however because in-plane resistance of the cathode was fair-ly high due to its high specific resistivity. To reduce the in-plane resistance of LSM-YSZ cathode cathode side current collecting layer was required. Ohmic resistance {{{{ {R }_{1 } }} was reduced after forming LSM current col-lecting layer on the LSM-YSZ cathode. In case of pure LSM cathode the formation of Pt, or LSCO current collecting layer reduced polarization resistance {{{{ {R }_{p } }} but ohmic resistance {{{{ {R }_{1 } }} was relatively constant. After annealing of LSM cathode with Pt current collector at higher temperature polarization resistance {{{{ {R }_{p } }} was in-creased but ohmic resistance {{{{ {R }_{1 } }} was constant. These phenomena indicate that Pt or LSCo current col-lecting layers act as a catalytic layer for oxygen reduction of pure LSM cathode. LSCO current collector was effective in reducing the ohmic and polarization resistance of LSM-YSZ cathode.

  • PDF

Torque Ripple Reduction for Permanent Magnet Synchronous Motor using Harmonic Current Injection (고조파 전류를 이용한 영구자석형 동기 전동기의 토크 리플 저감)

  • Kwon, Soon-O;Lee, Jeong-Jong;Lee, Geun-Ho;Hong, Jung-Pyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1930-1935
    • /
    • 2009
  • This paper deals with the torque ripple reduction of permanent magnet synchronous motor using harmonic current injection. Torque ripple of electric motor reduces system stability and performances, therefore efforts to reduce torque ripple are exerted in the design process. Torque ripple can be reduced by appropriate pole/slot combination, skew of rotor or stator, design of magnetic circuit, etc. In addition, torque ripple can be also reduced by input voltage and current, and many researches have been conducted to reduce torque ripple for six-step drive. Torque ripple reduction for current vector controlled permanent magnet synchronous motor also have been conducted and verified by investigating back emf wave form. Torque ripple reduction in this paper started from getting torque profile according to input current and electrical angle calculated by FEA, then instantaneous currents at each electrical angles for constant torque are calculated and applied to experiments. Therefore, 0% of torque ripple can be obtained theoretically with harmonic current injection. In order to maximize the effect of torque ripple reduction, a BLDC motor having high harmonic component of back emf is chosen. With sinusoidal current drive, over 100% of torque ripple is obtained initially, then 0.5 % of torque ripple is obtained by FEA using harmonic current injection. The effect is verified by experiment and the presented method can be effectively applicable to Electric Power Steering(EPS).

High Performance Current Sensing Circuit for Current-Mode DC-DC Buck Converter

  • Jin, Hai-Feng;Piao, Hua-Lan;Cui, Zhi-Yuan;Kim, Nam-Soo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.1
    • /
    • pp.24-28
    • /
    • 2010
  • A simulation study of a current-mode direct current (DC)-DC buck converter is presented in this paper. The converter, with a fully integrated power module, is implemented by using sense method metal-oxide-semiconductor field-effect transistor (MOSFET) and bipolar complementary metal-oxide-semiconductor (BiCMOS) technology. When the MOSFET is used in a current sensor, the sensed inductor current with an internal ramp signal can be used for feedback control. In addition, the BiCMOS technology is applied in the converter for an accurate current sensing and a low power consumption. The DC-DC converter is designed using the standard $0.35\;{\mu}m$ CMOS process. An off-chip LC filter is designed with an inductance of 1 mH and a capacitance of 12.5 nF. The simulation results show that the error between the sensing signal and the inductor current can be controlled to be within 3%. The characteristics of the error amplification and output ripple are much improved, as compared to converters using conventional CMOS circuits.

Study of changes in the kinetic parameters of corrosion on the macrocell current induced by the repair of reinforced concrete structures - Results of numerical simulation

  • Mostafa Haghtalab;Vahed Ghiasi;Aliakbar Shirzadi Javid
    • Computers and Concrete
    • /
    • v.32 no.3
    • /
    • pp.287-302
    • /
    • 2023
  • Corrosion of reinforcing bars in reinforced concrete structures due to chloride attack in environments containing chloride ions is one of the most important factors in the destruction of concrete structures. According to the abundant reports that the corrosion rate around the repair area has increased due to the macro-cell current known as the incipient anode, it is necessary to understand the effective parameters. The main objective of this paper is to investigate the effect of the kinetic parameters of corrosion including the cathodic Tafel slope, exchange current density, and equilibrium potential in repair materials on the total corrosion rate and maximum corrosion rate in the patch repair system. With the numerical simulation of the patch repair system and concerning the effect of parameters such as electromotive force (substrate concrete activity level), length of repair area, and resistivity of substrate and repair concrete, and with constant other parameters, the sensitivity of the macro-cell current caused by changes in the kinetic parameters of corrosion of the repairing materials has been investigated. The results show that the maximum effect on the macro-cell current values occurred with the change of cathodic Tafel slope, and the effect change of exchange current density and the equilibrium potential is almost the same. In the low repair extant and low resistivity of the repairing materials, with the increase in the electromotive force (degree of substrate concrete activity) of the patch repair system, the sensitivity of the total corrosion current reduces with the reduction in the cathode Tafel slope. The overall corrosion current will be very sensitive to changes in the kinetic parameters of corrosion. The change in the cathodic Tafel slope from 0.16 to 0.12 V/dec and in 300 mV the electromotive force will translate into an increase of 200% of the total corrosion current. While the percentage of this change in currency density and equilibrium potential is 53 and 43 percent, respectively. Moreover, by increasing the electro-motive force, the sensitivity of the total corrosion current decreases or becomes constant. The maximum corrosion does not change significantly based on the modification of the corrosion kinetic parameters and the modification will not affect the maximum corrosion in the repair system. Given that the macro-cell current in addition to the repair geometry is influenced by the sections of reactions of cathodic, anodic, and ohmic drop in repair and base concrete materials, in different parameters depending on the dominance of each section, the sensitivity of the total current and maximum corrosion in each scenario will be different.

Effect of Microstructure on Alternating Current-induced Damage in Cu Lines

  • Park Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.1 s.34
    • /
    • pp.27-33
    • /
    • 2005
  • The effect of microstructure on alternating current-induced damage in 200 and 300 nm thick polycrystalline sputtered Cu lines on Si substrates has been investigated. Alternating currents were used to generate temperature cycles (with ranges from 100 to $300^{\circ}C$) and thermal strains (with ranges from 0.14 to $0.42\%$) in the Cu lines at a frequency of 10 kHz. Fatigue loading caused the development of severe surface roughness that was localized within individual grains which depends severely on grain orientations.

  • PDF