• Title/Summary/Keyword: current standard

Search Result 3,844, Processing Time 0.03 seconds

A Study on the Indoor Environment of school classrooms in Seoul area (서울지역 학교 교실의 실내환경 조사연구)

  • 최한영
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.2
    • /
    • pp.67-74
    • /
    • 2003
  • In 15 schools where were chosen each location (East, West, South, North, Central) of Seoul area, 9 items were measured such as thermo circumstance(temperature, relative humidity, air current, intensity of illumination) particulate matter, carbon monoxide, sulfur dioxide, and nitrogen dioxide being based on the school indoor environment standard. It was showed that indoor temperature, relative humidity and air movement were suitable in comparison with school indoor environment standard. Intensity of illumination was suitable in comparison with all schools, only exception 2 schools. In all investigated schools were adequate for carbon monoxide, sulfur dioxide and nitrogen dioxide, in which each indoor environment standard (10ppw, 0.25ppm/hr, 0.15ppm/hr), but in 5 schools the carbon dioxide were exceeded for standard limit 1,000ppm of Korea. Indoor concentration of dust(PM-10) induced from respiration dust the standard of Korea ($150{\mu}g/m^3$) at all schools.

A Study on Korean Defense Specification Practice Standard Development Initiative (국방규격작성 방법 발전방안에 관한 연구)

  • Song, Jae-Yong;Son, Seung-Hyun;Sung, In-Cheol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.90-101
    • /
    • 2008
  • Korean defense specifications are the technical criteria of military products and major factor of acquisition system. Weapon systems and acquisition technique have been advanced dramatically after 1990's, but Korean defense specification practice standard has stayed after early 1980's except embedded software. The current status of current Korean defense specification practice standard and trend of related design and acquisition techniques like M&S, SBA, and digital manufacturing have been reviewed. This paper suggests that transfer to product, IT oriented specification structure, adaptation of digital product model and reinforcement of engineering management systems to establish a development initiative of Korean defense specification practice standard.

A Study on the Complement of Stand Agreement System for the BlM Implementation (BlM실행을 위한 표준계약체계 보완에 관한 연구)

  • Kim, Yong-Hee;Choi, Jong-Chon;Kim, Khil-Chae
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.9 no.1
    • /
    • pp.83-90
    • /
    • 2009
  • Building Information Modeling (BIM) has the great possibility of transforming the AEC industry. BIM will require increased information exchange and mutual collaboration between all stakeholders. BIM implementation and such increased collaboration can affect legal issues and contract provisions. And some legal issues accompanying BIM Implementation will be raised while a large change also comes in responsibility and role between all stakeholders. However, current standard agreement system is based on fragmented agreement between the architect and the owner, and between the owner and the contractor. Another legal obstacles and considerations associated with BIM implementation will be arose from BlM technology and use of BIM. AEC professionals in Korea have long utilized the standard agreement forms as well and look forward complementation of current standard agreement for BlM implementation. Such complement direction for the standard agreement will be examined by investigating the legal issues and overview comparison between AlA E202 and ConsensusDOCS 301.

  • PDF

A Study on Standard Unit Price Analysis of e-learning & Postal Distance Learning (인터넷 및 우편 원격 기관 훈련비용 기준단가 분석 연구 공학교육에 관한 연구)

  • Rha, Hyeon-Mi
    • Journal of Engineering Education Research
    • /
    • v.14 no.3
    • /
    • pp.61-71
    • /
    • 2011
  • Korea has introduced the levy-grand system in the vocational learning finance. The standard unit price system of training cost was utilized in the distribution of training budget and the reimbursement system including total or partial training cost return has been operated in the corporate training after completing the learning course particularly. The standard unit price was calculated in the base of analyzing on supporting budget by the government per training institutions and corporate payment decision to learning institutions. The proposing standard unit price system of training cost was analyzed in the current standard price unit of training cost and then an improvement policy and the implication are derived from it. At the result of this study, the current government supporting level to e-learning and postal distance learning indicates good status.

Flow-Guider Applied to Controlling Current in a Bay (도류제에 의한 항만내 조류제어 연구)

  • 양찬규;홍기용
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.141-151
    • /
    • 1997
  • This paper deals with a numerical study of flow-guider applied to controlling current in a bay. Two dimensional numerical model for tidal currents based on the depth averaged equation is developed and standard k-.epsilon. model is adopted to determine the turbulence diffusion. Equations are described in a generalized coordinate system to be implemented by non-staggered grid system and discretized by using finite volume method. Unsteady flow is simulated by fully implicit scheme. Hybrid scheme and central differencing are used to compute the convective terms and source terms, respectively. The tidal current in a rectangular bay is simulated and it gives satisfactory results. The realistic and distinct models of a large structure placed in bay are also exemplified with or without flow-guiders. The simulation results show that the flow-guider gives the residual tidal current in the bay by the different flux with respect to the direction of tidal current.

  • PDF

Fault Current Calculation and Coordination by IEC Standards (IEC 표준에 의한 고장전류 계산과 보호협조)

  • Son, Seok-Geum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.6-12
    • /
    • 2014
  • The safety and reliability of the power system short-circuit current, the short-circuit current depends on the failure to obtain the objective is to quickly eliminate the breaking capacity of the circuit-breaker selection of the cable, the insulation of electrical equipment and protective relay an important factor in determining the level correction and protective relay selection scheme to be meaningful. Standards used in the domestic circuit breaker is applied to the production of IEC standard, but the American National Standards (ANSI / IEEE) by NEMA specification of the fault current calculations and the application of the asymmetric coefficient Korea. Therefore, in this paper, the IEC 60909 standard IEC breaker fault current calculation method and the method for selection of system configurations reviewed and protection system for reviewing the configuration of various protective relays appropriate correction and the correction value is main protection, back-up protection the equipment so that the period of protection relay coordination to minimize accidents and accident protection to minimize interruptions proposed for cooperation.

Analysis of Relationship between Standard Depth of Penetration Skin Effect and Phase Angle of Defect Signal of Eddy Current Testing (와전류(渦電流) 표준침투(標準浸透) 깊이 표피효과(表皮效果)와 결함신호(缺陷信號) 위상각(位相角)의 관계해석(關係解析))

  • Chung, Tae-Eon;Chang, Kee-Oak;Park, Dae-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.4 no.2
    • /
    • pp.7-14
    • /
    • 1985
  • An experiment to investigate the rate of change of phase angle of eddy current output signal caused by outer surface defect of nonferromagnetic tube by variation of standard depth of penetration and variation of percent of tube wall penetration was carried out. The results of the experiment show that the phase angle of defect signal is increased with decreasing the standard depth of penetration or the depth of defect. The results also show that the phase angle is decreased with increasing the skin effect of eddy current, and that the resolution is decreased with decreasing the depth of defect.

  • PDF

A study on standard implementation method of defense CALS system (국방 CALS체계의 표준 적용방안에 관한 연구)

  • 김철환;송인출
    • Proceedings of the CALSEC Conference
    • /
    • 1999.11a
    • /
    • pp.75-84
    • /
    • 1999
  • CALS is a strategy to share integrated product data through a set of standards to achieve efficiencies in business and operational mission areas. In this research, we first studied current status for CALS standard and then analyzed the case of US DoD. The results can be summarized as implementing for two major standard in defense CALS system. They are STEP and XML. Our recommendations can be used to set direction for CALS standard implementation and standard selection process.

  • PDF

Modification of Current Leak Before Break Criteria for Nuclear Piping System (원자력 발전소 배관에 대한 파단전누설 개념 적용기준의 수정)

  • Yu, Yeong-Jun;Kim, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.6
    • /
    • pp.1862-1871
    • /
    • 1996
  • The puopose of this paper is sto modify the current LBB criteria. The validity of current LBB criteria and current standard LBB analysis mehtod are evaluated using linear elastic fracture mechanics and elastic-plastic fracture mechanics. The results of evaluation demonstrate that the current LBB driteria are very conservative and some level of margins already exist in the standard LBB analysis method. Thus, the margin on load .root. and margin on crack size 2 can be eliminated to extend LBB application for the samller diameter pipe.

A Development of the Third Rail Current Collecting Shoegear for the Light Rail Transit (경량전철 차량용 제3궤조 집전장치의 개발)

  • 정락교;김연수;박성혁;이병송;최규형
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.4
    • /
    • pp.185-193
    • /
    • 2000
  • In general, a third rail current collecting shoegear is widely used in the light rail transit system since it is more efficient and economical than an overhead pantograph. Therefore, its specification is prescribed in the Korean standard specifications for the light rail transit for its applications. This paper describes the development of the third rail current collecting shoegears which is suitable to Korean situation and satisfactory to the Korean standard specifications. Two types are developed for the steel wheel and the rubber tyred AGT system, and various experiments are executed. It is found that performance of the third rail current collecting shoegear developed is proved acceptable.

  • PDF