  • Many sensitive loads always rely on UPS systems to maintain continuous power during abnormal utility power conditions. As any disturbance occurs at the utility side, an off-line UPS system takes over the load within a quarter cycle to avoid a blackout. However, the starting of the inverter can root the momentous inrush current for the transformer installed before the load, due to its magnetic saturation. The consequences of this current can be a reduction of line voltage and tripping of protective devices of the UPS system. Furthermore, it can also damage the transformer and decrease its lifetime by increasing the mechanical stresses on its windings. To prevent the inrush current, and to avoid its disruptive effects, this paper proposes an off-line UPS system that eliminates the inrush current phenomenon while powering the transformer coupled loads, using a current regulated voltage source inverter (CRVSI) instead of a typical voltage source inverter (VSI). Simulations have been performed to validate the operation of proposed off-line UPS system.

  • PDF

CURRENT CONTROL FOR PWM AC-DC CONVERTER USING SINUSOIDAL TRACKING CONTROLLER

  • Woo, Jung-In;Heo, Tae-Won;Lee, Hyun-Woo;Kim, Choon-Sam;Jung, Yung-Il
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.928-933
    • /
    • 1998
  • This paper presents a novel current control system to eliminate the steady state control error and to improve the transient characteristics for PWM AC-DC converter. A general mathematical model of the converter that is represented as a state-space model is first established. The state-space model is used for the simulation of PWM switching converter with the proposed current control system. The proposed sinusoidal tracking control system that does not require coordinate transformations using principle of the integral controller is described. It is proved that the steady state deviation reduces to zero through a transfer function of source current control system. Finally, it is seen that simulations agree with the experimental results in source current and reference of controlled ac current loop.

  • PDF

교류측 센서를 제거한 3상 PWM 정류기의 새로운 제어 (A Novel Control Scheme of Three-Phase PWM Rectifiers Eliminating AC-Side Sensors)

  • 이동춘;이지명;임대식
    • 전력전자학회논문지
    • /
    • 제5권6호
    • /
    • pp.592-600
    • /
    • 2000
  • 본 논문은 직류측 센서만을 갖는 3상 PWM 정류기의 새로운 제어기법을 제안한다. 제어가 내부의 모텔전류와 시스템 전류의 편차를 영으로 제어하여 상전압의 크기와 위상을 추정하고 스위칭 상태와 직류링크전류로부터 상전류를 재구성한다. 제안한 상전압 빛 상전류 센서리스 기법을 PWM 정류기 시스템에 적용한 실험을 통하여 그 타당성을 검증하였다.

  • PDF

PI 제어기의 내부원리를 이용한 PWM AC-DC 컨버터의 새로운 전류제어 (Novel current control for PWM AC-DC converter using internal principle of PI controller)

  • 허태원;황영민;김영빈;이현우;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1944-1946
    • /
    • 1998
  • This paper presents a novel current control system to eliminate the steady state control error for PWM AC-DC converter. A general mathematical model of the converter which is represented as a state-space model is established. The state-space model is used for the simulation of converter with the proposed tracking control system of sinusoidal current. In this system, a novel current control which do not require coordinate transformations using internal principle of PI controller is described. It is proved that the steady state deviation reduce to zero through a transfer function of source current control system. Finally, simulations show good source current control characteristics by means of a simplified control system which do not require coordinate transformations.

  • PDF

Automatic Power Factor Correction Using a Harmonic-Suppressed TCR Equipped with a New Adaptive Current Controller

  • Obais, Abdulkareem Mokif;Pasupuleti, Jagadeesh
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.742-753
    • /
    • 2014
  • In this paper, a new continuously and linearly controlled capacitive static VAR compensator is proposed for the automatic power factor correction of inductive single phase loads in 220V 50Hz power system networks. The compensator is constructed of a harmonic-suppressed TCR equipped with a new adaptive current controller. The harmonic-suppressed TCR is a new configuration that includes a thyristor controlled reactor (TCR) shunted by a passive third harmonic filter. In addition, the parallel configuration is connected to an AC source via a series first harmonic filter. The harmonic-suppressed TCR is designed so that negligible harmonic current components are injected into the AC source. The compensator is equipped with a new adaptive closed loop current controller, which responds linearly to reactive current demands. The no load operating losses of this compensator are negligible when compared to its capacitive reactive current rating. The proposed system is validated on PSpice which is very close in terms of performance to real hardware.

Open and Short Circuit Switches Fault Detection of Voltage Source Inverter Using Spectrogram

  • Ahmad, N.S.;Abdullah, A.R.;Bahari, N.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.190-199
    • /
    • 2014
  • In the last years, fault problem in power electronics has been more and more investigated both from theoretical and practical point of view. The fault problem can cause equipment failure, data and economical losses. And the analyze system require to ensure fault problem and also rectify failures. The current errors on these faults are applied for identified type of faults. This paper presents technique to detection and identification faults in three-phase voltage source inverter (VSI) by using time-frequency distribution (TFD). TFD capable represent time frequency representation (TFR) in temporal and spectral information. Based on TFR, signal parameters are calculated such as instantaneous average current, instantaneous root mean square current, instantaneous fundamental root mean square current and, instantaneous total current waveform distortion. From on results, the detection of VSI faults could be determined based on characteristic of parameter estimation. And also concluded that the fault detection is capable of identifying the type of inverter fault and can reduce cost maintenance.

Three-Phase Three-Switch Buck-Type Rectifier Based on Current Source Converter for 5MW PMSG Wind Turbine Systems

  • Chae, Beomseok;Suh, Yongsug;Kang, Tahyun
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1501-1512
    • /
    • 2018
  • This paper proposes a three-phase three-switch buck-type converter as the MSC of a wind turbine system. Owing to a novel switching modulation scheme that can eliminate the unwanted diode rectifier mode switching state, the proposed system exhibits a satisfying ac voltage and current waveform quality and torque ripple up to the level of a typical current source rectifier even under a wide power factor operating range. The proposed system has been verified through simulations and HILS tests on a PMSG wind turbine model of 5MW/4160V. The proposed converter has been shown to provide a stator current THD of 3.9% and a torque ripple of 1% under the rated power condition. In addition to the inherent advantage of the reduced switch count of three-phase three-switch buck-type converters, the proposed switching modulation technique can make this converter a viable solution for the MSC placed inside of a nacelle, which is under severe volume, weight and mechanical vibration design limits.

HVDC 시스템의 SCR 사이리스터 밸브 시험을 위한 Full-Bridge Converter 방식의 개선된 전류원 회로 (Improved Current Source using Full-Bridge Converter Type for Thyristor Valve Test of HVDC System)

  • 정재헌;조한제;구법진;노의철;정용호;백승택
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.363-368
    • /
    • 2015
  • This paper deals with an improved current source using full-bridge converter type for thyristor valve test of HVDC system. The conventional high-current and low-voltage source of synthetic test circuit requires additional auxiliary power supply to provide the reverse voltage for the auxiliary thyristor valve during turn-off process. The proposed circuit diagram to provide the reverse voltage is extremely simple because no additional component is required. The reverse voltage can be obtained from the input DC voltage of the high-current and low-voltage power supply. The operation principle and design method of the proposed system are described. Simulation and experimental results in scaled down STC of 200 V, 30 A demonstrate the validity of the proposed scheme.

열전지의 열원 연소에 따른 전류집전체 열변형에 관한 연구 (A Study on the Thermal Deformation of Current Collectors by Burning Heat Pellets in Thermal Batteries)

  • 지현진;김종명;김영철;조성백
    • 한국군사과학기술학회지
    • /
    • 제15권4호
    • /
    • pp.527-534
    • /
    • 2012
  • Thermal batteries are primary batteries that use molten salts as an electrolyte and employ an internal pyrotechnic source to heat the battery stack to operating temperatures, typically between 450 and $550^{\circ}C$. The unit cell of thermal batteries consists of an anode, an electrolyte, a cathode, a heat pellet and a current collector. The heat source for such batteries is typically heat pellets based on $Fe/KClO_4$. The elevated temperature by combustion of heat pellet is supposed to cause a flatness non-uniformity, buckling, with a lateral extension diameter of current collector. This paper mainly focused on the combustion and buckling model of current collector to simulate the effect of heat source. Mechanical stresses in the current collector caused by thermal stress is a critical design consideration of thermal batteries because the internal short circuit could be occurred.

소스영역으로 오버랩된 게이트 길이 변화에 따른 터널 트랜지스터의 터널링 전류에 대한 연구 (Source-Overlapped Gate Length Effects at Tunneling current of Tunnel Field-Effect Transistor)

  • 이주찬;안태준;심언성;유윤섭
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.611-613
    • /
    • 2016
  • TCAD 시뮬레이션을 이용하여 소스영역으로 오버랩된(overlapped) 게이트를 가진 터널링 전계효과 트랜지스터(Tunnel Field-Effect Transistor; TFET)의 오버랩된 게이트 길이에 따른 터널링 전류 특성을 조사하였다. 터널링은 크게 라인터널링과 포인트 터널링으로 구분되는데, 라인터널링이 포인트터널링보다 subthreshold swing(SS), on-current에서 더 높은 성능을 보인다. 본 논문은 Silicon, Germanium, Si-Ge Hetero TFET구조에서 게이트 길이를 소스영역으로 오버랩될 경우에 포인트 터널링과 라인터널링의 효과를 조사해서 SS와 on-current에 최적합한 구조의 가이드라인을 제시한다.

  • PDF