• 제목/요약/키워드: current sampling

검색결과 826건 처리시간 0.029초

단일 전류 센서를 사용한 3상 전압형 PWM 컨버터의 제어 방식 비교 (Comparison of Three-Phase Voltage-Source PWM Converters Using a Single Current Sensor)

  • 이우철;이택기;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권4호
    • /
    • pp.188-200
    • /
    • 2001
  • This paper presents a technique for reconstructing converter line currents using the information from a single current sensor in the DC-link for voltage-source PWM converters. When three-Phase input currents cannot be reconstructed, three methods to acquire the input current are compared. Two of them are methods of modifying the switching state (I, II), another is a method of using the predictive state observer. Also, compensation of sampling delay, and a simultaneous sample value of input currents in the center of a switching period are included. Suitable criteria for the comparison are identified, and the differences in the performance of these methods are investigated through experimental results for a typical V-S PWM converter rated at 10kVA.

  • PDF

Current Estimator를 이용한 멀티레이트 제어기 설계 (Design of Multirate Controller using a Current Estimator)

  • 황희철;정정주
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.190-190
    • /
    • 2000
  • This paper presents a multirate state feedback control (MRSFC) method for systems sensitive to disturbance and noise based on the multirate estimator design using the current estimator. MRSFC updates the controller output slower than the measurement sampling frequency of system output by a lifting factor R=T$\sub$c//T$\sub$s/. The closed-loop MRSFC system is less sensitive to disturbance and noise due to filtering effect than the conventional single-rate control system. The multirate estimator gain is obtained from solving a conventional pole placement problem such that MRSFC has the same spectrum of eigenvalues in the s-plane as the single-rate control. We applied the proposed multirate state feedback controller to a galvanometer servo system. Simulation and experimental results show that settling and tracking performances are improved compared with a conventional single-rate pole placement control (PPC).

  • PDF

Ku-대역 유전체 공진기 발진기의 Sampling Phase Detector를 이용한 위상 고정 루프 필터 설계 및 제작 (Design of Phase Locking Loopfilter Using Sampling Phase Detector for Ku-Band Dielectric Resonator Oscillator)

  • 오 바담가라와;양승식;오현석;이만희;정해창;염경환
    • 한국전자파학회논문지
    • /
    • 제19권10호
    • /
    • pp.1147-1158
    • /
    • 2008
  • 본 논문에서는 SPD(Sampling Phase Detector) 소자를 위상검출기로 사용하여, 기준 신호원 700 MHz SAW(Surface Acoustic Wave) 발진기에 16.8 GHz의 VTDRO(Voltage Tuned Dielectric Resonator Oscillator)를 안정화하는 위상 고정 회로를 설계하였다. 이러한 위상 고정 방법은 루프 필터만으로 직접적으로 위상 고정할 경우 잠금 시간(lock time)의 문제로, 루프 필터뿐만 아니라 구형파의 시변하는 전류원을 사용 위상 고정하게 된다. 이러한 구동 회로와 루프 필터는 서로 상관 관계가 있어, 이의 체계적인 조정을 필요로 한다. 본 논문에서는 이러한 구동 회로와 루프 필터의 체계적인 설계 방법을 제시하였다. 제작된 PLDRO(Phase Leered DRO)는 안정된 16.8 GHz의 중심 주파수에서 약 6.3 dBm의 출력 전력을 갖고, 위상 잡음은 100 kHz offset에서 -101 dBc/Hz 성능을 보인다.

Analysis of the Phase Current Measurement Boundary of Three Shunt Sensing PWM Inverters and an Expansion Method

  • Cho, Byung-Geuk;Ha, Jung-Ik;Sul, Seung-Ki
    • Journal of Power Electronics
    • /
    • 제13권2호
    • /
    • pp.232-242
    • /
    • 2013
  • To obtain phase currents information in AC drives, shunt sensing technology is known to show great performance in cost-effectiveness and therefore it is widely used in low cost applications. However, shunt sensing methods are unable to acquire phase currents in certain operation conditions. This paper deals with the derivation of the boundary conditions for phase current reconstruction in three-shunt sensing inverters and proposes a voltage injection method to expand the measurable areas. As the boundary conditions are deeply dependent on the switching patterns, they are typically analyzed on the voltage vector plane for space vector pulse width modulation (SVPWM) and discontinuous pulse width modulation (DPWM). In the proposed method, the voltage injection and its compensation are conducted within one sampling period. This guarantees fast current reconstruction and the injected voltage is decided so as to minimize the current ripple. In addition to the voltage injection method, a sampling point shifting method is also introduced to improve the boundary conditions. Simulation and experimental results are presented to verify the boundary condition derivation and the effectiveness of the proposed voltage injection method.

연산지연시간과 파라미터 변동에 강인한 UPS 인버터의 내부모델제어 (Internal Model Control of UPS Inverter with Robustness of Calculation Time Delay and Parameter Variation)

  • 박지호;계중읍;김동완;안영주;박한석;우정인
    • 전기학회논문지P
    • /
    • 제51권4호
    • /
    • pp.175-185
    • /
    • 2002
  • In this paper, a new fully digital current control method of UPS inverter, which is based on an internal model control, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The internal model controller is adopted to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. That is, the average current of filter capacitor is been exactly equal to the reference current with a time lag of two sampling intervals. Therefore, this method has an essentially overshoot free reference-to-output response with a minimum possible rise time. The effectiveness of the proposed control system has been verified by the simulation and experimental respectively. From the simulation and experimental results, the proposed system is achieved the robust characteristics to the calculation time delay and parameter variation as well as very fast dynamic performance, thus it can be effectively applied to the power supply for the critical load.

Current-induced Phase Demodulation Using a PWM Sampling for a Fiber-optic CT

  • Park, Hyoung-Jun;Lee, June-Ho;Kim, Hyun-Jin;Song, Min-Ho
    • Journal of the Optical Society of Korea
    • /
    • 제14권3호
    • /
    • pp.240-244
    • /
    • 2010
  • In this work, we used PWM sampling for demodulation of a fiber-optic interferometric current transformer. The interference signal from a fiber-optic CT is sampled with PWM triggers that produce a 90-degree phase difference between two consecutively sampled signals. The current-induced phase is extracted by applying an arctangent demodulation and a phase unwrapping algorithm to the sampled signals. From experiments using the proposed demodulation, we obtained phase measurement accuracy and a linearity error, in AC current measurements, of ~2.35 mrad and 0.18%, respectively. The accuracy of the proposed method was compared with that of a lock-in amplifier demodulation, which showed only 0.36% difference. To compare the birefringence effects of different fiber-optic sensor coils, a flint glass fiber and a standard single-mode fiber were used under the same conditions. The flint glass fiber coil with a Faraday rotator mirror showed the best performance. Because of the simple hardware structure and signal processing, the proposed demodulation would be suitable for low-cost over-current monitoring in high voltage power systems.

평균전류모드제어를 이용하는 컨버터의 모델링 및 설계 (Modeling and Design of Average Current Mode Control)

  • 정영석
    • 전력전자학회논문지
    • /
    • 제10권4호
    • /
    • pp.347-355
    • /
    • 2005
  • 본 논문에서는 평균전류모드제어를 이용하는 컨버터의 연속시간 소신호 모델을 구한다. 평균전류모드제어에 일반적으로 사용되는 보상기를 적용한 컨버터의 해석을 위해 샘플러를 전류루프에 포함시켜 해석한다. 기존 모델에서는 정확히 해석하기 어려웠던 전류루프 이득의 고주파 영역 해석이 제안한 모델을 이용함으로 쉽게 해결할 수 있으며, 시스템의 안정성을 결정하는 고주파 영역에서의 주파수 응답 특성을 제안한 모델이 우수한 성능으로 예측 가능함을 보인다. 이를 위해 평균전류모드제어에서 전류루프에 샘플러가 포함된 모델을 제시하고 이 샘플러에 대한 연속시간 모델을 구하여 평균전류모드제어의 연속시간 모델을 구한다. 제안한 새로운 연속시간 소신호 모델을 이용한 예측 결과를 스위칭 모델 시뮬레이션 프로그램인 PSIM을 이용한 시뮬레이션 결과 및 실험결과와 비교하여 제안한 새로운 연속시간 소신호 모델의 우수성을 확인한다

오버샘플된 전류신호를 사용한 인버터 구동형 전동기의 베어링 고장검출 시스템 (High Precison Bearing Fault Detect System of Inverter Driven System Using Oversampled Current Signals)

  • 김남훈;김민회;최창호;이상훈;최경호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.506-508
    • /
    • 2007
  • In this paper, the induction motor bearing fault diagnosis system using current signals which are measured by over-sampling method is presented. In the case of inverter fed motor drive unlike line-driven motor drive, that make a lot of noise which can cause a wrong fault signals because of PWM(pulse width modulation) voltage. So, the current signals for fault diagnosis need very precise and high resolution information, which means this system demand additional hardware such as low pass filter, high resolution ADC system and so on to use fault diagnosis system. Therefore, the proposed over-sampling method is expected to contribute to low cost fault diagnosis system even though previous inverter fed motor drive without any additional hardware. In order to confirm the presented algorithms, various experiments for bearing faults are tested and the line current spectrum of each faulty situation using park transformation is compared with a FFT results.

  • PDF

축산물생산비조사를 위한 복합표본설계 (A Complex Sampling Design for the Estimation of Korean Livestock Production Cost)

  • 김수택;김영원
    • 응용통계연구
    • /
    • 제21권4호
    • /
    • pp.675-694
    • /
    • 2008
  • 축산물 생산비 조사는 우리나라에서 생산되는 7종의 주요 축산물에 대한 생산비를 산출하는 것을 목적으로 한다. 따라서 2005년 농업총조사 자료를 바탕으로 전국의 양축 농가 현황을 파악하였으며, 축산물별 평균 생산비에 대한 추정오차가 3%이내가 되도록 표본 축산농가수를 결정하고, 표본의 대표성을 유지하면서 조사 업무의 수월성을 고려하여 농업특성화 조사구를 1차 추출단위로 활용하였다. 본 연구에서는 농업특성화 조사구들을 양축 특성에 따라 층화하고 각 층에서 예비 표본 조사구를 추출하였다. 다음으로 예비 표본 조사구를 실사하여 1단계 표본을 구성하고, 1단계 표본 양축 농가로부터 최종 표본 농가를 계통추출하는 이중추출법을 이용하였으며 이에 따른 추정법을 제시하였다.

가변모수를 갖는 EWMA 관리도 (EWMA Control Charts with Variable Parameter)

  • 이재헌;한정희
    • 품질경영학회지
    • /
    • 제33권4호
    • /
    • pp.117-122
    • /
    • 2005
  • Variable sampling rate(VSR) scheme varies the sampling rate for the current sample depending on the previous value of the control statistic. In this paper, we propose EWMA control charts with variable parameter(VP) scheme, which allows both the sample rate(the sample size or the sampling interval) and the weight to vary. We investigate the effectiveness of the VP scheme relative to the fixed parameter(FP) scheme and the VSR scheme in EWMA control charts. It is shown that using the VP scheme gives some improvements to the ability in detecting small and moderate shifts in the process normal mean.