• Title/Summary/Keyword: current pulse

Search Result 1,869, Processing Time 0.039 seconds

The Study on the Contents and Satisfaction of Oriental Medicine Examination Program (한방건강검진 프로그램의 내용과 참가자들의 만족도에 관한 연구)

  • Lee Eun-Kyoung;Jahng Doo-Sub;Song Yung-Sun;Lee Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.6 no.1
    • /
    • pp.51-95
    • /
    • 2002
  • 1. As a point at issue of occidental medicine examination, followings have been indicated, 1) Occidental medical examination is performed by mainly test and instrument and therefore, role of doctors could be excluded and it could be diagnosed only for target disease and 2) in Korea, it could not be conducted in public medical system and therefore improvement effect of public health promotion could not be made due to increase of total medical expenses and infirmity of post management. These points are substantial limit of paradigm resided in occidental medicine and also problem caused by unique characteristics of medical system of Korea. In Korea, result of occidental medical examination show increased health risk from aged thirties and major diagnosed diseases are circulatory disease or chronic disease such as hepatic, hyperlipemic, hypertensional disease and diabetes, etc. Accounting that those chronic disease make a role as major public health risk, it is difficult that medical examination by only occidental medicine make effect on public health promotion. 2. Characteristics of oriental medicine examination could be summarized as diagnosis (information acquisition based on the facts) and demonstration (speculation based on acquired information) and in addition, quadruple diagnosis, as a medical examination method, include test as well as basic examination. Accounting on oriental medical examination, principally it is performed by independent herbalist and therefore, herbalist could acquire systemic result during first medical examination. Based on the theory of inner-outer examination, oriental medical examination has a principle of universe theory, systemic analysis of quadruple diagnosis, demonstration & reasoning. In addition, root of oriental medical examination could be found in pre-disease theory, a principal theory of oriental medicine. Pre-disease service could prove the advantage of oriental medicine in medical examination activities and therefore, it is needed that content of oriental medical examination should be actualized in current medical system. 3. In this study, oriental medical examination program, comprised of pulse-diagnosis, contrast muscular taking and medical consultation of herbalist is progressed communally with occidental medical examination. As pre-examination, questionary was given of general characteristics, health promoting life style, physical constitution and subjective symptom of musculoskeletal system. In addition, post-examination notification was given to subjects about health promoting control, physical constitution regimen and management of musculoskeletal system. During this study program, verification was conducted for input of acquired information and difference of each information after analysis and in addition, performed was analysis of factor influencing health promoting life style and musculoskeletal subjective symptom and evaluation of relationship of physical constitution and health promoting life study. In addition, it was verified of difference between musculoskeletal subjective symptom and result of muscle contrast picture evaluation. 4. Evaluation of oriental medical examination model is divided into 2 categories of oriental medical examination-consultation and result evaluation -post management. Oriental medical examination-consultation demands establishment of examination system, standardization of examination and establishment of examination form and in addition, it should be admitted as enlarged examination assists systemic quadruple diagnosis of herbalist not a key of oriental medical examination. In addition, information acquisition for research purpose should be performed according to the systemic research plan based on the separation of questionary for examination purpose and research purpose. For evaluation of the result, it was concluded that needed are result evaluation meets oriental medical system and post-notification system, informing health management information, based on examination result. 5. Accounting on satisfaction for oriental medical examination model, affirmative reply was much higher (66%) than negative (8.64%). Satisfaction of each area was in order of consultation of herbalist, systemic muscle contrast taking, pulse examination, post-notification and questionary fill-up and dissatisfaction was in order of post-notification, questionary fill-up, consultation of herbalist, systemic muscle contrast taking and pulse measurement. Satisfaction for collaborative examination of occidental and oriental medicine was over 60% and over 75% hope oriental examination would be included in later medical examination program. Based on this result, collaborative examination including occidental and oriental medicine could increase satisfaction of subjects for medical examination program.

  • PDF

Aortic Remodelling in Chronic Nicotine-Administered Rat

  • Zainalabidin, Satirah;Budin, Siti Balkis;Ramalingam, Anand;Lim, Yi Cheng
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.18 no.5
    • /
    • pp.411-418
    • /
    • 2014
  • Vascular remodelling is an adaptive mechanism, which counteracts pressure changes in blood circulation. Nicotine content in cigarette increases the risk of hypertension. The exact relationship between nicotine and vascular remodelling still remain unknown. Current study was aimed to determine the effect of clinically relevant dosage of nicotine (equivalent to light smoker) on aortic reactivity, oxidative stress markers and histomorphological changes. Twelve age-matched male Sprague-Dawley rats were randomly divided into two groups, i.e.: normal saline as control or 0.6 mg/kg nicotine for 28 days (i.p., n=6 per group). On day-29, the rats were sacrificed and the thoracic aorta was dissected immediately for further studies. Mean arterial pressure (MAP) and pulse pressure (PP) of nicotine-treated vs. control were significantly increased (p<0.05). Nicotine-treated group showed significant (p<0.05) increase tunica media thickness, and decrease in lumen diameter, suggesting vascular remodelling which lead to prior hypertension state. The phenylephrine (PE)-induced contractile response in nicotine group was significantly higher than control group ($ED_{50}=1.44{\times}10^5M$ vs. $4.9{\times}10^6M$) (p<0.05~0.001). However, nicotine-treated rat showed significantly lower endothelium-dependent relaxation response to acetylcholine (ACh) than in control group ($ED_{50}=6.17{\times}10^7M$ vs. $2.82{\times}10^7M$) (p<0.05), indicating loss of primary vascular function. Malondialdehyde (MDA), a lipid peroxidation marker was significantly higher in nicotine group. Superoxide dismutase (SOD) enzymatic activity and glutathione (GSH) were all reduced in nicotine group (p<0.05) vs. control, suggesting nicotine induces oxidative imbalance. In short, chronic nicotine administration impaired aortic reactivity, probably via redox imbalance and vascular remodelling mechanism.

The engineering merit of the "Effective Period" of bilinear isolation systems

  • Makris, Nicos;Kampas, Georgios
    • Earthquakes and Structures
    • /
    • v.4 no.4
    • /
    • pp.397-428
    • /
    • 2013
  • This paper examines whether the "effective period" of bilinear isolation systems, as defined invariably in most current design codes, expresses in reality the period of vibration that appears in the horizontal axis of the design response spectrum. Starting with the free vibration response, the study proceeds with a comprehensive parametric analysis of the forced vibration response of a wide collection of bilinear isolation systems subjected to pulse and seismic excitations. The study employs Fourier and Wavelet analysis together with a powerful time domain identification method for linear systems known as the Prediction Error Method. When the response history of the bilinear system exhibits a coherent oscillatory trace with a narrow frequency band as in the case of free vibration or forced vibration response from most pulselike excitations, the paper shows that the "effective period" = $T_{eff}$ of the bilinear isolation system is a dependable estimate of its vibration period; nevertheless, the period associated with the second slope of the bilinear system = $T_2$ is an even better approximation regardless the value of the dimensionless strength,$Q/(K_2u_y)=1/{\alpha}-1$, of the system. As the frequency content of the excitation widens and the intensity of the acceleration response history fluctuates more randomly, the paper reveals that the computed vibration period of the systems exhibits appreciably scattering from the computed mean value. This suggests that for several earthquake excitations the mild nonlinearities of the bilinear isolation system dominate the response and the expectation of the design codes to identify a "linear" vibration period has a marginal engineering merit.

Design and Fabrication of Ka-Band Active PIN Diode Limiter for a Millimeter Wave Seeker (밀리미터파 탐색기용 Ka 대역 능동 PIN 다이오드 리미터 설계 및 제작)

  • Yang, Seong-Sik;Lim, Ju-Hyun;Na, Young-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.2
    • /
    • pp.220-228
    • /
    • 2012
  • In this paper, we explained the design technique about Ka-band active limiter for protecting the receiver of a millimeter wave seeker. To implement low flat leakage power, we proposed the control circuit of active limiter to control limiter voltage with PRF(Pulse Repetition Frequency) signal and input power. This active limiter consisted of the conventional 2 stage passive limiter, a feedback circuit with a directional coupler, detector, non-inverting amplifier and over-current protection resistance. As the test result of the fabricated Ka-band limiter, it had 1 GHz bandwidth, 3.5 dB insertion loss at the small input power and -7.5 dBm flat leakage at the 4 W RF input power, respectively.

A Study on Novel Step Up-Down DC/DC Chopper of Isolated Type with High Efficiency (새로운 고효율 절연형 스텝 업-다운 DC/DC 초퍼에 관한 연구)

  • Kwak, Dong-Kurl
    • Journal of IKEEE
    • /
    • v.13 no.4
    • /
    • pp.82-88
    • /
    • 2009
  • This paper is analyzed for a step up-down DC/DC chopper of high efficiency added electric isolation. The converters of high efficiency are generally made that the power loss of the used semiconductor switching devices is minimized. To achieve high efficiency system, the proposed chopper is constructed by using a partial resonant circuit. The control switches using in the chopper are operated with soft switching by partial resonant method. The control switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the efficiency of the chopper is high. The proposed chopper is also added electric isolation which is used a pulse transformer. When the power conversion system is required electric isolation, the proposed chopper is adopted with the converter system development of high efficiency. The soft switching operation and the system efficiency of the proposed chopper are verified by digital simulation and experimental results.

  • PDF

Dose- and Time-Related Effects of Pilocarpine Mouthwash on Salivation

  • Song, Je-Il;Park, Jo-Eun;Kim, Hye-Kyoung;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.42 no.3
    • /
    • pp.72-80
    • /
    • 2017
  • Purpose: Pilocarpine as a salivation stimulant in pill form has mostly been used to relieve oral dryness for xerostomic patients but its use may often be limited due to variable side effects from systemic absorption. Therefore, the purpose of this study was to investigate the effects of pilocarpine mouthwash on salivation according to the variable concentration and duration for healthy volunteers. Related adverse effects and subjective assessment on its effects on salivation were also examined. Methods: This study was performed as placebo-controlled, double-blind, randomized clinical trial. Thirty healthy volunteers (male=23, mean age=22.2 years) were randomly allocated to 6 groups with the different concentration of pilocarpine mouthwash (placebo, 0.1%, 0.5%, 1.0%, 1.5%, and 2.0%). The whole experiment consisted of 3 sessions according to the duration of mouthwash, i.e., 1, 3, and 5 minutes with the mean wash-out period ${\geq}2$ days between the sessions. Unstimulated whole saliva was collected before and after gargling with a mouthwash. Results: Salivation of the higher concentration groups ${\geq}1%$ significantly increased than those of lower concentration group. The application period of mouthwash did not cause any changes of salivary flow rate at the higher concentrations ${\geq}1.0%$. The lower concentrations of 0.5% and 0.1% had no effects on salivation even after 5-minute mouthwash. There was no significant difference between blood pressure and pulse rate before and after use of mouthwash. Conclusions: From the results of the current study, pilocarpine mouthwash with at least 1.0% concentration more than a minute might be clinically effective in salivation without any serious side effects. Dose of mouthwash rather than duration seems to be a critical factor to salivation.

Measurement of electron density of atmospheric pressure Ar plasma jet by using Michelson interferometer

  • Lim, Jun-Sup;Hong, Young June;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.195.1-195.1
    • /
    • 2016
  • Currently, as Plasma application is expanded to the industrial and medical industrial, low temperature plasma applications became important. Especially in medical and biology, many researchers have studied about generated radical species in atmospheric pressure low temperature plasma directly adapted to human body. Therefore, so measurement their plasma parameter is very important work and is widely studied all around world. One of the plasma parameters is electron density and it is closely relative to radical production through the plasma source. some kinds of method to measuring the electron density are Thomson scattering spectroscopy and Millimeter-wave transmission measurement. But most methods have very expensive cost and complex configuration to composed of experiment system. We selected Michelson interferometer system which is very cheap and simple to setting up, so we tried to measuring electron density by laser interferometer with laser beam chopping module for measurement of temporal phase difference in plasma jet. To measuring electron density at atmospheric pressure Ar plasma jet, we obtained the temporal phase shift signal of interferometer. Phase difference of interferometer can occur because of change by refractive index of electron density in plasma jet. The electron density was able to estimate with this phase difference values by using physical formula about refractive index change of external electromagnetic wave in plasma. Our guiding laser used Helium-Neon laser of the centered wavelength of 632 nm. We installed chopper module which can make a 4kHz pulse laser signal at the laser front side. In this experiment, we obtained more exact synchronized phase difference between with and without plasma jet than reported data at last year. Especially, we found the phase difference between time range of discharge current. Electron density is changed from Townsend discharge's electron bombardment, so we observed the phase difference phenomenon and calculated the temporal electron density by using phase shift. In our result, we suggest that the electron density have approximately range between 1014~ 1015 cm-3 in atmospheric pressure Ar plasma jet.

  • PDF

Electromagnetic Retarder's Power Recovery Device and Voltage Control (전자기형 리타더의 전력회수장치 및 전압제어)

  • Jung, Sung-Chul;Yoon, In-Sik;Ko, Jong-Sun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.5
    • /
    • pp.396-403
    • /
    • 2016
  • Usually, large-sized buses and trucks have a very high load. In addition, frequent braking during downhill or long-distance driving, causes the conventional method using the brake friction to have a problem in safety because of brake fade and brake burst phenomenon. Auxiliary brakes dividing the braking load is essential. Hence, environment-friendly auxiliary brakes, such as contactless brake rather than the engine auxiliary brake system are needed. A study aimed at improving the energy efficiency by recharging electric energy with changing mechanical to electrical energy that occurs when braking is actively in progress. In this paper, the voltage control method is utilized to recover the electric energy generated in the electromagnetic retarder instead of the eddy current. To regenerate the braking energy into the electrical energy, the resonant L-C circuit is configured in the retarder. The voltage generated in the retarder is simply modeled as a transformer. However, retarder voltage control in this paper is simulated by modeling the induction generator because this induction generator modeling is more practical than transformer modeling. The changes in the voltage of the resonance circuit, which depends on the switch pulse duration of the control device, were analyzed. A PI controller algorithm to control this voltage is proposed. The feasibility of modeling retarder and voltage controller are shown by using MATLAB Simulink in this paper.

Characteristics of Low-level Light Source for Animal Cell Proliferation (동물 세포 증식을 위한 저출력 광 소스의 특성)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Song, Chang-Hun;Mun, Seong-Pyo;Kim, Tae-Gon;Park, Yong-Pil;Kim, Dae-Young;Kim, Young-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.1
    • /
    • pp.92-97
    • /
    • 2007
  • This paper performed the basic study for developing the Photodynamic Therapy Equipment for medical treatment. We developed the equipment palpating cell proliferation using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 30 levels by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and Pulse Width Modulation(PWM), and the output of a high brightness LED could be controlled stage by stage. And then, each experiment was performed to irradiation group and non-irradiation group for both Rat bone marrow and Rat tissue cells. MTT assay method was chosen to verify the cell increase of two groups and the effect of irradiation on cell proliferation was examined by measuring 590 nm transmittance of ELISA reader. As a result, the cell increase of Rat bone marrow and tissue cells was verified in irradiation group as compared to non-irradiation group. The fact that specific wavelength irradiation has an effect on cell vitality and proliferation is known through this study.

Maximum Torque Operation of SRM by using a Self-tuning Control Method (SRM의 최대 토크 운전을 위한 자기동조 제어)

  • 서종윤;김광헌;장도현
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.240-245
    • /
    • 2004
  • This paper presents a Switched Reluctance Motor(SRM) drive using the self-tuning control method to achieve the maximum torque. SRM has the difficulty to research it by an analytic method and to control the speed End torque because of the high nonlinearity. So, in this paper, the self-tuning control method is applied to relevantly controlling turn-on/off angle to operate at the maximum torque. Also, the feedback signals to control the turn-on/off angle are the encoder pulse and the increment of phase current. At first, n adequate turn-off angle is searched by itself and then a turn-on angle is done. As the relationship between turn-on and him-off angle is mutual dependent, the turn-on/off angle is controlled by a real time self-tuning control method in order to maintain the maximum torque. The proposed self-tuning Algorithm is verified by experiments.