• Title/Summary/Keyword: current phase

Search Result 5,370, Processing Time 0.038 seconds

Phase Current Reconstruction Method of 2-Phase Induction Motor using Leg-Shunt Resistors (레그 션트저항을 이용한 2상 유도전동기의 상전류 복원 방법)

  • Kim, Dong-Ki;Yoon, Duck-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1186-1192
    • /
    • 2015
  • This paper proposes an economical method that the phase currents can be measured and reconstructed by means of the leg-shunt resistors in the 3-leg 2-phase vector-controlled inverter for 2-phase induction motor. In general, the phase currents of 2-phase induction motor have been measured using two Hall current sensors. However, because Hall current sensors are expensive, economically disadvantageous to apply in low power applications. The proposed method is verified by computer simulations and experiments to show the good performance of the vector control.

Fault-Tolerant Control of Five-Phase Induction Motor Under Single-Phase Open

  • Kong, Wubin;Huang, Jin;Kang, Min;Li, Bingnan;Zhao, Lihang
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.899-907
    • /
    • 2014
  • This paper deals with fault-tolerant control of five-phase induction motor (IM) drives under single-phase open. By exploiting a decoupled model for five-phase IM under fault, the indirect field-oriented control ensures that electromagnetic torque oscillations are reduced by particular magnitude ratio currents. The control techniques are developed by the third harmonic current injection, in order to improve electromagnetic torque density. Furthermore, Proportional Resonant (PR) regulator is adopted to realize excellent current tracking performance in the phase frame, compared with Proportional Integral (PI) and hysteresis regulators. The analysis and experimental results confirm the validity of fault-tolerant control under single-phase open.

Evaluation Technique for Ratio Error and Phase Displacement of Current Transformer Comparator (전류변성기 비교기의 비오차 및 위상오차 평가기술)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.437-443
    • /
    • 2008
  • We have developed an evaluation technique for both ratio error and phase displacement of current transformer (CT) comparator by using the precise standard capacitors and resistors. By applying this technique to equivalent circuit of CT comparator evaluation system, we can obtain the calculated and measured ratio errors (or phase displacements) in the CT comparator. Thus we can evaluate ratio errors and phase displacement of CT comparator by comparing the calculated and measured ratio errors (or phase displacements). The method was applied to CT comparator under test with the ratio errors and phase displacement ranges of $0{\sim}{\pm}10%$ and $0{\sim}{\pm}7.5$ crad, respectively. Finally we have compared the ratio error and phase displacement of the CT comparator obtained in this method with specifications of two companies.

Current-Programmed Control of Three Phase PWM AC-AC Boost Converter

  • Choi, Nam-Sup;Li, Yulong
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.414-416
    • /
    • 2005
  • In this paper, a new scheme of current programmed control for three phase PWM AC-AC converter is presented. By considering only the magnitude components, a similar scheme in the DC-DC converter can be extended to the three phase PWM AC-AC converter. The proposed current programmed control will be well adopted into various converter topologies though three phase PWM AC-AC boost converter is treated as an example. The converter analysis is carried out by applying the vector DQ transformation to obtain physical insight into the converter operation. Finally, the experiment result shows the validity of the proposed scheme.

  • PDF

High precision Gating Algorithm for Predictive Current Control of Phase Controlled Rectifier (위상제어 정류기의 예측전류제어를 위한 새로운 고정밀 게이팅 알고리즘)

  • 정세종;송승호
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.3
    • /
    • pp.206-211
    • /
    • 2004
  • In phase controlled rectifier, it's been known that a fast response is achieved by predictive current control without any overshoot. The frequent sampling period is essential to improve the firing accuracy in conventional predict current control. However, improving the firing accuracy if difficult to reduce the period of sampling efficiently because current sampling and predictive current control is carried out in every period and the ON-OFF current control is performed by comparing two different one. To improve the firing accuracy at the predictive current control, the calculated firing angle is loaded into the high-accuracy hardware timer. So the calculation of exact crossing point between the predictive and actual current is the most important. In this paper, the flow chart for proposed firing angle calculation algorithm is obtained for the fastest current control performance in transient state. The performance of proposed algorithm is verified through simulations and experiments.

Generalized Circulating Current Control Method in Parallel Three-Phase Boost Converters (병렬 삼상 부스트 컨버터에서 일반화된 순환전류 제어 방법)

  • Lim, Chang-Soon;Lee, Kui-Jun;Kim, Rae-Young;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.250-257
    • /
    • 2011
  • This paper analyzes characteristic of the three-phase coupled inductor connected to ac source to effectively mitigate the high-frequency circulating current generated in parallel three-phase boost converters. The three-phase coupled inductor analysis presented in this paper uses the three-phase coupled inductor structure and voltage equations. Based on this analysis, the three-phase coupled inductor is added to the conventional low-frequency averaged model. As a result, the novel averaged model which can reduce the low and high-frequency circulating current simultaneously is developed. Using the zero-sequence component of the novel averaged model, each total inductance to the circulating current of the three-phase coupled inductor and line inductor can be obtained. Simulation and experiment results verify the usefulness of three-phase coupled inductor in parallel three-phase boost converters.

Single Sensor Current Control for Three-Phase Voltage-Source PWM Converters Using a Predictive State Observer (예측 상태 관측기를 이용한 3상 전압 원 PWM 컨버터의 단일 센서 전류 제어)

  • 이우철;현동석;이택기
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.489-492
    • /
    • 1999
  • This paper proposes a control method for three-phase voltage-source PWM converters using only a single current sensor in the DC link. A predictive current controller for the voltage-source PWM converter is used so that all phase currents can be reconstructed in a switching period although one or two of active vectors are applied only for a short time. Compensation of the 2 step delays is also included. In this paper single sensor current control using predictive state observer will be discussed, and investigated experimentally.

  • PDF

A New Controller of Single Phase Active Power Filter Using Rotating Synchronous Frame d-q Transformation (회전하는 동기 좌표계 d-q 변환을 이용한 단상 능동 전력 필터의 새로운 제어기)

  • Kang, Min Gu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.271-275
    • /
    • 2014
  • A New Single Phase Active Power Filter Controller is proposed using Rotating Synchronous Frame d-q transformation. Instantaneous Active Power is calculated using d-q transformation. Average Value of Instantaneous Active Power is obtained using Low Pass Filter. Because power factor is corrected, source current is in phase with source voltage. Amplitude of source current is calculated using single phase power formula. Reference signal of compensated current of Active power filter is obtained from source current reference signal minus load current. Simulation is performed using hysteresis current controller in proposed new controller. Simulation result shows that because active power filter compensates load current, source current is in phase with source voltage and source current is sinusoidal. And Hilbert transformer is builded using all pass filter.

Secondary Current Range Extension of Current Transformers by Using Two Different Current Transformers and Absolute Evaluation Technique (전류변성기 두 대와 절대 평가 기술을 이용한 2차 전류 범위 확장)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.72-78
    • /
    • 2009
  • We have developed a current range extension method to obtain the ratio error and phase displacement of a current transformer (CT) by using absolute evaluation method and two different CTs. The method was applied to CTs under test with the current ratios in the range of 5,000 A / 1 A - 20,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Germany using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

An Improved Current Control Method for Three-Phase PWM Inverters Using Three-Level Comparator (3레벨 비교기를 이용한 3상인버터의 개선된 히스테리시스 전류제어 기법)

  • Moon, Hyoung-Soo;Han, Woo-Yong;Lee, Chang-Goo;Sin, Dong-Yong;Kim, Mu-Youn
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1035-1037
    • /
    • 2001
  • This paper presents an improved hys- teresis current control method for three-phase PWM power inverters using 3-level comparator. Hysteresis current controller using 3-level comparator has an advantage of constant switching frequency compared with conventional hysteresis current controller. However, this method has disadvantage that the longer sampling period, the larger current error because the switching is performed without considering current error magnitude of each phase. The proposed method improves the control performance by selecting the optimum switching pattern in which the magnitudes of current errors are considered introducing space vector concept. Simulation results using Matlab/Simulink show that the proposed control method reduces current error keeping the merit of previous hysteresis current control method.

  • PDF