• Title/Summary/Keyword: current mode

Search Result 3,010, Processing Time 0.031 seconds

A Novel Predictive Digital Controlled Sensorless PFC Converter under the Boundary Conduction Mode

  • Wang, Jizhe;Maruta, Hidenori;Matsunaga, Motoshi;Kurokawa, Fujio
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • This paper presents a novel predictive digital control method for boundary conduction mode PFC converters without the need for detecting the inductor current. In the proposed method, the inductor current is predicted by analytical equations instead of being detected by a sensing-resistor. The predicted zero-crossing point of the inductor current is determined by the values of the input voltage, output voltage and predicted inductor current. Importantly, the prediction of zero-crossing point is achieved in just a single switching cycle. Therefore, the errors in predictive calculation caused by parameter variations can be compensated. The prediction of the zero-crossing point with the proposed method has been shown to have good accuracy. The proposed method also shows high stability towards variations in both the inductance and output power. Experimental results demonstrate the effectiveness of the proposed predictive digital control method for PFC converters.

A 94% Efficiency Current-mode DC-DC boost converter with automatic PFM/PWM conversion (94%효율을 가진 PFM/PWM 자동변환 전류-모드 DC-DC Boost 변환기)

  • Jeong, Bong-Yong;Nam, Hyun-Seok;Roh, Jeong-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.599-600
    • /
    • 2008
  • This paper presents a high performance DC-DC boost converter by current-mode control method. As load current change, the converter change PWM/PFM operation automatically. current-mode DC-DC boost converter is implemented in a standard $0.35{\mu}m$ CMOS process. The peak efficiency was 94 % with a switching frequency of 1.2MHz.

  • PDF

Three-Phase Common-Mode Active EMI Filters for Induction Motor Drive Applications

  • Tarateeraseth, Vuttipon
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.871-878
    • /
    • 2018
  • In this paper, the conducted EMI reduction performances of active feed-forward current-sensing current-actuation (CSCA) and voltage-sensing current-actuation (VSCA) filters for a three-phase induction motor drive system are evaluated by experiments. For comparison purposes, the conducted EMI (CM emission, DM emission and total emission) of a three-phase induction motor drive with a conventional CM choke, a conventional CM choke in series with an active VSCA filter, and an active CSCA filter (where the CM choke was modified and used as a sensing current transformer) were compared to the case of a system without any filter inserted. Experimental results show that the active CSCA and VSCA filters can improve the CM reduction performance of the conventional CM choke by about 5 dB especially at low-frequencies. However, for DM comparisons, it shows that there is no different between cases with and without filters inserted.

Mixed-Mode Simulation of the Power MOSFET with Current Limiting Capability (전류 제한 능력을 갖는 전력용 MOSFET의 Mixed-Mode 시뮬레이션)

  • Yun, Chong-Man;Choi, Yearn-Ik;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1451-1453
    • /
    • 1994
  • A monolithic current limiting power MOSFET, which may be easily fabricated by the conventional DMOS process, is proposed. The proposed current limiting MOSFET consists of main power cells, sensing cells, and NPN lateral bipolar transistor so that users can adjust the current limiting levels with only one external resistor. The behaviors of the proposed device are numerically simulated and analyzed by 2-D device simulator MEDICI and mixed-mode simulator CA-AAM(Circuit Analysis Advanced Application Module).

  • PDF

Current sensor using an evanescent field of single-mode optical fiber (단일모드 광섬유의 소산장을 이용한 전류센서)

  • 손경락;김형표
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.10
    • /
    • pp.57-62
    • /
    • 2004
  • We report the fiber-optic current sensors composed of a side-polished single-mode fiber with the thermo-optic Polymer layer and the metal wire as a heater. The index change of polymer layers caused by the resistant heat of the metal wires induces the optical attenuation through the evanescent field of the side-polished single-mode fiber. Two types of the sensors are proposed and their characteristics as a current sensor are investigated.

Sub-1.2-V 1-Gb Mobile DRAM with Ultra-low Leakage Current (극저 누설전류를 가지는 1.2V 모바일 DRAM)

  • Park, Sang-Kyun;Seo, Dong-Il;Jun, Young-Hyun;Kong, Bai-Sun
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.433-434
    • /
    • 2007
  • This paper describes a low-voltage dynamic random-access memory (DRAM) focusing on subthreshold leakage reduction during self-refresh (sleep) mode. By sharing a power switch, multiple iterative circuits such as row and column decoders have a significantly reduced subthreshold leakage current. To reduce the leakage current of complex logic gates, dual channel length scheme and input vector control method are used. Because all node voltages during the standby mode are deterministic, zigzag super-cutoff CMOS is used, allowing to Preserve internal data. MTCMOS technique Is also used in the circuits having no need to preserve internal data. Sub-1.2-V 1-Gb mobile DDR DRAM employing all these low-power techniques was designed in a 60 nm CMOS technology and achieved over 77% reduction of overall leakage current during the self-refresh mode.

  • PDF

Alternative Derivation of Continuous-Time Model for Current-Mode Control (전류모드제어를 위한 연속시간모델의 새로운 유도 방법)

  • Jung Dong-Yeol;Hong Sung-Soo;Choi Byung-Cho;Sakong Sug-Chin
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.218-222
    • /
    • 2002
  • Two existing continuous-time models for the current-mode control have presented noticeable differences in their small-signal predictions. As an attempt to clarify the origin of these disparities, this paper presents an alternative way of deriving a continuous-time model for the current-model control. The results of this paper would provide insights to comprehend the dissimilarity in the modeling method and final results of the earlier models of current-mode control.

  • PDF

A New Reduced Common-mode Voltage SVM Method for Indirect Matrix Converters with Output Current Ripple Minimization

  • Tran, Quoc-Hoan;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.383-384
    • /
    • 2015
  • This paper presents a new space vector modulation (SVM) method for indirect matrix converters (IMCs) to reduce commonmode voltage as well as minimize output current ripple in a high voltage transfer ratio. In the proposed SVM, the three-vector modulation scheme is used in the rectifier stage, while the nonzero state modulation technique, where the three nearest active vectors are selected to synthesize the desired output voltage, is applied to inverter stage to reduce the CMV. The proposed SVM method can significantly reduce the output current ripple and common-mode voltage of the IMC without any extra hardware. Simulated results are provided to demonstrate the effectiveness of the proposed SVM method.

  • PDF

Digital Switching Control Method for Current shaping of Single Phase Flyback Inverter for Photovoltaic AC Modules (PV-AC 모듈형 단상 플라이백 인버터의 출력 전류 품질 보정을 위한 디지털 스위칭 제어기법)

  • Noh, Yong-Su;Lim, Sung-Bum;Ji, Young-Hyok;Jung, Doo-Yong;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.47-48
    • /
    • 2012
  • In generally, grid connected single-phase flyback inverter is operated as boundary or discontinuous conduction mode. However, the flyback inverter can be operated in continuous conduction mode (CCM) due to its operating conditions in spite of it is designed to operate under boundary or discontinuous conduction mode. This situation causes unintended distortion to output current. In this paper, a current shaping method on unfolding bridge to reduce the output current distortion.

  • PDF

Current Mode Integrated Control Technique for Z-Source Inverter Fed Induction Motor Drives

  • Thangaprakash, Sengodan;Krishnan, Ammasai
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.285-292
    • /
    • 2010
  • This paper presents a current mode integrated control technique (CM-ICT) using a modified voltage space vector modulation (MSVM) for Z-source inverter (ZSI) fed induction motor drives. MSVM provides a better DC voltage boost in the dc-link, a wide range of AC output voltage controllability and a better line harmonic profile. In a voltage mode ICT (VM-ICT), the outer voltage feedback loop alone is designed and it enforces the desired line voltage to the motor drive. An integrated control technique (ICT), with an inner current feedback loop is proposed in this paper for the purpose of line current limiting and soft operation of the drive. The current command generated by the PI controller and limiter in the outer voltage feedback loop, is compared with the actual line current, and the error is processed through the PI controller and a limiter. This limiter ensures that, the voltage control signal to the Z-source inverter is constrained to a safe level. The rise and fall of the control signal voltage are made to be gradual, so as to protect the induction motor drive and the Z-source inverter from transients. The single stage controller arrangement of the proposed CM-ICT offers easier compensation. Analysis, Matlab/Simulink simulations, and experimental results have been presented to validate the proposed technique.