• 제목/요약/키워드: current limitation

검색결과 911건 처리시간 0.025초

YBCO Coated Conductor의 과전류 특성해석 (Analysis of Over-current Characteristics in YBCO Coated Conductor)

  • 이찬주;남관우;강형구;고태국;석복렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.693-694
    • /
    • 2006
  • In order to develop a high temperature superconducting(HTS) coil for the fault current limiter(FCL), the over-current characteristics in YBCO coated conductor(CC) with Ni-W alloy substrate are analyzed. The HTS wire is wound by bifilar winding method for resistive current limitation and it is operated in 65K sub-cooled nitrogen. In order to analyze the resistance and the temperature characteristics of the CC wire, an analysis program is developed considering all the composition materials except the buffer layer. Using this program, the temperature rise, the resistance development and the current limitation of CC are calculated depending on the applied voltage and the stabilizer materials. According to the analysis results, under the temperature restriction of 300K, the maximum voltage per meter is determined as 40V/m if the stabilizer is $25{\mu}m$ thick stainless steel at each side. Finally, the wire length needed for the distribution level HTS FCL is estimated.

  • PDF

폐수특성 및 처리기술에 근거한 산업폐수 배출허용기준 설정체계 연구 (Establishment of Effluent Limitation based on Wastewater Characteristics and Treatment Technology)

  • 권오상;정진영;허태영;전항배;이연희;박상민
    • 한국물환경학회지
    • /
    • 제28권6호
    • /
    • pp.804-812
    • /
    • 2012
  • This study contemplated domestic and other country's effluent limitation standards and suggested a methodology to establish technology-base limitation value. Current effluent limitation regulates industrial point sources discriminated by discharge flow rate and by regional distinction in Korea. Discharged $BOD_5$ load from large-scale plants(flow rate above $2,000\;m^3/day)$ exceeds 50% of overall industrial wastewater, which present rationale for discrimination based on plant size. However, regional distinction and pollutant- specific regulation might be insufficient to meet practical effectiveness of wastewater management policy, due to the nearly same limitation. Water quality data and treatment methods were investigated in hospital industry. And their distribution of effluent $BOD_5$ concentrations was statistically analyzed to suggest limitation value. Effluent $BOD_5$ concentrations showed lognormal distribution and $95^{th}$ percentile was corresponded to 87.9 mg/L, which could be suggested as tentative effluent limitation in hospital industry. The $95^{th}$ percentile of log-transformed distribution showed similar value of 86.5 mg/L. This study demonstrated reasonable methodology for establishing effluent limitation reflecting wastewater characteristic and treatment technology in separately categorized industry.

활동정보회계시스템의 구축에 관한 연구 : 유연성과 적용가능성을 중심으로 (A Study on Activity Information Accounting Systems : Focusing on Their Flexibilities and Applicabilities)

  • 신건권
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제7권1호
    • /
    • pp.55-76
    • /
    • 1998
  • Various trials to overcome the limitation of current accounting which fails in synchronizing business activities and their information have failed to make satisfactory result merely showing a little saving of processing time. This is because such trials have been done within the boundary of double-entry bookkeeping system. Without consolidating business activities and their information, reformation efforts such as BPR(business process re-engineering), ABC(activity-based costing), CALS(commerce at light speed) etc to fit the business organization to the changing business environment could not be achieved. Overcoming the limitation of accounting takes precedence of any other attempt to construct the management information systems. Activity Information Accounting System(AIAS) proposes the way of overcoming the limitation of current accounting by using the new accounting methodology and unique solution to real time accounting information. AIAS produces accounting and management information directly of activity information without bookkeeping process of activity information. AIAS adopts method of transforming the details of corporation activities directly into accounting information rather than method of double-entry bookkeeping system. The purpose of this paper is to prove AIAS to be very flexible system by using flexibility concepts. Flexibilities are defined as three aspects, namely ① timeliness (rapid accounting information generations and presentations) ② easy systems modificabilities according to environment changes ③ adaptabilities to all industries.

  • PDF

RCD success criteria estimation based on allowable coping time

  • Ham, Jaehyun;Cho, Jaehyun;Kim, Jaewhan;Kang, Hyun Gook
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.402-409
    • /
    • 2019
  • When a loss of coolant accident (LOCA) occurs in a nuclear power plant, accident scenarios which can prevent core damage are defined based on break size. Current probabilistic safety assessment evaluates that core damage can be prevented under small-break LOCA (SBLOCA) and steam generator tube rupture (SGTR) with rapid cool down (RCD) strategy when all safety injection systems are unavailable. However, previous research has pointed out a limitation of RCD in terms of initiation time. Therefore, RCD success criteria estimation based on allowable coping time under a SBLOCA or SGTR when all safety injection systems are unavailable was performed based on time-line and thermal-hydraulic analyses. The time line analysis assumed a single emergency operating procedure flow, and the thermal hydraulic analysis utilized MARS-KS code with variables of break size, cooling rate, and operator allowable time. Results show while RCD is possible under SGTR, it is impossible under SBLOCA at the APR1400's current cooling rate limitation of 55 K/hr. A success criteria map for RCD under SBLOCA is suggested without cooling rate limitation.

The Effect of Gap Size on Counter Current Flow Limitation Phenomena in Narrow Annular Gaps with Large Diameter

  • Jeong, Ji-Hwan;Lee, Seung-Jin;Park, Rae-Joon;Kim, Sang-Baek
    • Nuclear Engineering and Technology
    • /
    • 제34권4호
    • /
    • pp.396-405
    • /
    • 2002
  • An experimental study on counter-current flow limitation phenomena in narrow annular passages was carried out The gap sizes tested were 1, 2 and 3 mm. This is very small compared with the outer diameter of the annular passage, 500 mm. It was visually observed that a CCFL might occur in some part of the periphery while the other part is remained in a counter current flow pattern. That is, non-uniform behaviour of fluids due 4o a 2-dimensional effect appear in a large diameter facility. Because of this non-uniformity, a CCFL is defined in the present work as the situation where net water accumulation is sustained. That is, some amount of water should not be allowed to penetrate the gap and accumulate over the gap at CCFL criterion. The measured data are presented in the form of Wallis'type correlation with characteristic length of gap size. It was found that the present correlation is in good agreement with other empirical correlation based on measurements whose test section diameter is close and the gap size is much larger than that of the present test section.

Gate turn on thyristor 역변환장치의 변환전력한계치에 대하여 (The analysis of the conversive limitation of electric energy for the gate turn on thyristor inverter)

  • 천희영
    • 전기의세계
    • /
    • 제17권2호
    • /
    • pp.6-10
    • /
    • 1968
  • The conversive limitation of electric energy for the thyristor inverter is analysed under the boundary conditions which the term of a negative inverse voltage is longer than that of the turn off time of the thyristor under commutation. It is clear that the maximum electric energy conversion is affected by the turn off time of the thyristor, the reactance of a commutation reactor, the capacity of a commutation condenser and the voltage of Direct current source. It is useful for design the thyrister invertor and the motor speed control to apply the above conclusion.

  • PDF

방송 코어 망(BCN) 표준화 동향 (Trends of Broadcast Core Network Standardization)

  • 김순철;이재영;허남호;최동준
    • 전자통신동향분석
    • /
    • 제36권6호
    • /
    • pp.25-35
    • /
    • 2021
  • ATSC 3.0 is a next-generation terrestrial broadcasting standard that provides various functions and improved performance compared to the existing ATSC 1.0 High Definition standard. Based on the ATSC 3.0 broadcast system with IP-centric transport and coherence, it can provide personalized and personalized interactive services to TV viewers. However, the broadcasting system still has a structural limitation in that the service is deployed separately from broadcasters who are allocated a specific frequency and is expected to have different spectrum allocation for each market. To overcome this structural limitation and provide improved services compared with the current ATSC 3.0, preliminary studies were conducted to apply the core network concept of a communication network (particularly 5G) to ATSC 3.0 broadcasting. Finally, in february of this year, the ATSC TG3/S43 group for the development of the ATSC 3.0 Broadcast Core Network (BCN) standard was launched. This paper describes the background and current status of BCN standardization by ATSC TG3/S43, and future standardization prospects.

국내 초전도 한류기 요구와 하이브리드 초전도 한류기 (Domestic Efforts for SFCL Application and Hybrid SFCL)

  • 현옥배;김혜림;임성우;심정욱;박권배;오일성
    • Progress in Superconductivity
    • /
    • 제10권1호
    • /
    • pp.60-67
    • /
    • 2008
  • We present domestic efforts for superconducting fault current limiter (SFCL) application in the Korea Electric Power Corporation (KEPCO) grid and pending points at issue. KEPCO's decision to upgrade the 154 kV/22.9 kV main transformer from 60 MVA to 100 MVA cast a problem of high fault current in the 22.9 kV distribution lines. The grid planners supported adopting an SFCL to control the fault current. This environment friendly to SFCL application must be highly dependent upon the successful development of SFCL having specifications that domestic utility required. The required conditions are (1) small size of not greater than twice of 22.9 kV gas insulated switch-gear (GIS), (2) sustainability of current limitation without the line breaking by circuit breakers (CB) for maximum 1.5 seconds. Also, optionally, recommended is (3) the reclosing capability. Conventional resistive SFCLs do not meet (1) $\sim$ (3) all together. A hybrid SFCL is an excellent solution to meet the conditions. The hybrid SFCL consists of HTS SFCL components for fault detection and line commutation, a fast switch (FS) to break the primary path, and a limiter. This characteristic structure not only enables excellent current limiting performances and the reclosing capability, but also allows drastic reduction of HTS volume and small size of the cryostat, resulting in economic feasibility and compactness of the equipment. External current limiter also enables long term limitation since it is far less sensitive to heat generation than HTS. Semi-active operation is another advantage of the hybrid structure. We will discuss more pending points at issues such as maintenance-free long term operation, small size to accommodate the in-house substation, passive and active control, back-up plans, diagnosis, and so on.

  • PDF

디스크 드라이브의 탐색시간 단축제어 (Control for Seek Time Reduction in Disk Drives)

  • 강창익;추상훈
    • 제어로봇시스템학회논문지
    • /
    • 제8권2호
    • /
    • pp.104-112
    • /
    • 2002
  • Controllers for acoustic noise reduction in disk drives have been developed but they have slower seek time performance than time-optimal controllers. We propose a new seek servo controller that has acoustic noise reduction benefit and faster seek time performance than conventional controllers. The proposed controller is designed to make sure that head is moved with maximized acceleration and deceleration under the voltage limitation imposed on head-positioning motor and so it provides faster seek time than conventional controllers designed by considering the current limitation. The experimental results using a commercially available disk drive confirm that the use of the proposed controller results in foster seek time than conventional controllers for acoustic noise reduction.