• 제목/요약/키워드: current lead

검색결과 1,715건 처리시간 0.024초

저항성 누설전류(Igr) 검출 콘센트의 개발 및 안전성 평가 (Development and Safety Estimation of Resistive Leakage Current(Igr) of Detection Outlet)

  • 김창성;한송엽;최충석
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.221-226
    • /
    • 2009
  • In this paper, we analyzed form of flowing leakage current in electrical installation. Leakage current ($I_g$) is consisted of resistive leakage current($I_{gr}$), capacitive leakage current($I_{gc}$), and inductive leakage current($I_{gl}$). Resistive leakage current($I_{gr}$) is big occasion than capacitive leakage current($I_{gc}$) in system, Residual Current Protective Device(RCD) detects correctly leakage current. But,$I_{gc}$ is big occasion than $I_{gr}$, RCD is malfunctioned It is resistance to lead to electric fire in electrical device. We manufactured outlet that resistive leakage current detecting circuit is had. Manufactured outlet displayed performance exactly in leakage current of 5 mA Therefore, this product estimates that contribute on electric fire courtesy call.

인버터 입력전류 분석을 이용한 유도전동기 고장진단 (Diagnosis of Induction Motor Faults Using Inverter Input Current Analysis)

  • 한정호;송중호;최규형
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.492-498
    • /
    • 2016
  • 운전 중인 유도전동기에 고장이 발생하면, 구동장치 등 전체 시스템에 2차적인 고장을 유발 시킬 수 있다. 이 경우 구동시스템의 신뢰도와 안전성이 저하되고, 경제적인 손실을 초래할 뿐만 아니라, 인명 피해의 위험 등 많은 문제가 발생할 수 있다. 따라서 유도전동기의 고장징후를 조기 감지하여 전체 시스템 고장을 방지할 수 있도록 하는 유도전동기 고장진단 방법이 필요하다. 본 논문은 유도전동기에서 고정자권선의 부분 단락과 회전자 바의 균열이 발생하는 경우, 인버터 입력전류를 분석하여 고장징후를 조기 감지하는 유도전동기 고장진단 방법을 제안한다. 제안한 고장진단 방법은 고정자 전류 3개를 모두 센싱해야 하는 기존 고장진단 방법과 달리, 인버터 입력전류 센서 한 개만으로 유도전동기 고장진단이 가능하다. 또한, 정상전류 주파수성분과 고장전류 주파수성분이 서로 분리되어 나타나는 인버터 입력전류 특성을 통해 기존 고장진단 방법보다 비교적 쉽고 확실한 고장진단이 가능하다. 시뮬레이션을 통하여 제안한 유도전동기 고장진단 방법의 우수성과 유효성을 확인한다.

Designs for 25-kA and 40-kA Vapor-Cooled Bi2223/Copper Leads with the Bi2223 Section Operating in the Current-Sharing Mode

  • Lee, Haigun;Kim, Ho-Min;Yukikazu Iwasa;Kim, Keeman
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권4호
    • /
    • pp.222-230
    • /
    • 2003
  • This paper presents reference designs for vapor-cooled HTS/Copper leads rated at 25 kA and 40 kA and that satisfy a protection criterion. Each HTS section is cooled by the effluent helium vapor boiling from a 4.2-K bath. Each HTS section is based on a design concept in which a short portion of its warm end (77.3 K) operates in the current-sharing mode; such operation results in a considerable saving for HTS materials required in the HTS section. Two designs of "fully superconducting" vapor-cooled HTS sections, one rated at 25 kA and the other at 40 kA are also presented as comparison bases for the new HTS sections. Each warm end of HTS sections is coupled to an optimal vapor-cooled copper lead rated at the same current as that for the HTS section. The extra coolant required at 77.3 K at the coupling station, an optimal length of the copper section will be shorter than that optimized for helium-vapor cooling between 4.2 K and room temperature.mperature.

벅 컨버터를 이용한 정전류 정전압 배터리 충전기 (Constant Current & Constant Voltage Battery Charger Using Buck Converter)

  • 아와스티 프라카스;강성구;김정훈;박성준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.399-400
    • /
    • 2012
  • The proposed battery charger presented in this paper is suitable for Lead-Acid Battery and the dc/dc buck converter topology is applied as a charger circuit. The technique adopted in this charger is constant current & constant voltage dual mode, which is decided by the value of voltage of proposed battery. Automatic mode change function is detected by the percentage value of level of battery charging. CC Mode (Constant Current Mode) is operated when charging level is below 80% of the total charging of Battery voltage and above 80% of battery voltage charging, CV Mode (Constant Voltage Mode) is automatically operated. As the charging level exceeds 120%, it automatically terminates charging. The feedback signal to the PWM generator for charging the battery is controlled by using the current and voltage measurement circuits simultaneously. This technique will degrade the damage of proposed type of battery and improve the power efficiency of charger. Finally, a prototype charger circuit designed for a 12-V 7-Ah lead acid battery is constructed and tested to confirm the theoretical predictions. Satisfactory performance is obtained from simulation and the experimental results.

  • PDF

C/H 철탑 종단접속함 보호용 피뢰기 리드선 길이에 따른 뇌과전압 분석 (Analysis on Lightning Overvoltage According to Lead Length of Surge Arrester for Underground Cable Outdoor Termination Protection at C/H Tower)

  • 정채균;강지원
    • 전기학회논문지
    • /
    • 제65권2호
    • /
    • pp.257-263
    • /
    • 2016
  • This paper describes the lightning arrester transients in cable head termination. The installation references of cable head tower and lightning arresters are firstly reviewed, then the performance of lightning arrester operation is also evaluated based on lightning overvoltage analysis by the change of grounding lead cable length. This paper finally proposes the optimal length of grounding lead cable at the cable head termination. The limited lightning current is also proposed according to the change of grounding lead cable length. The results will contribute to protecting insulation breakdown failure against lightning surge at the terminations and joints.

Strategies of A Potential Importance, Making Lead-Free Piezoceramics Truly Alternative to PZTs

  • Kim, Hwang-Pill;Ahn, Chang Won;Hwang, Younghun;Lee, Ho-Yong;Jo, Wook
    • 한국세라믹학회지
    • /
    • 제54권2호
    • /
    • pp.86-95
    • /
    • 2017
  • Active search for lead-free piezoceramics over the last decade has harvested a considerable amount of achievements both in theory and in practice. Few would deny that those achievements are highly beneficial, but agree that this quest of developing the lead-free piezoceramics in replace for PZTs is successfully completed. Nevertheless, few would clearly state where this quest should be directed in our next move. A source of this uncertainty may originate from the fact that it is still not clear how good is good enough to beat PZTs. In this short review, we analyzed the existing literature data to clearly locate the current state of the art of lead-free piezoceramics in comparison to PZT-based piezoceramics. Four strategies of a potential importance were suggested and discussed to help researchers plan and design their future research on lead-free piezoceramics with a recently reported exemplary work.

충청북도 일부 폐광산 지역 주민의 만성 납 노출 정도 평가 (Blood Lead Level in Populations Resident in Some Abandoned Mine Area)

  • 송선호;엄상용;김용대;김헌;홍장수
    • 한국환경과학회지
    • /
    • 제19권4호
    • /
    • pp.527-532
    • /
    • 2010
  • Exposure to lead, particularly at chronic low-dose levels, is still a major public health concern. The present study is aimed to evaluate the blood lead levels in populations resident in some abandoned mine areas of Chungbuk, Korea. Eight hundreds and sixty-six subjects who reside in abandoned mine area located in Chungbuk, Korea, were enrolled this study. We evaluated the blood lead level according to the age, gender, and working history in mines. For statistical analysis, SPSS ver 12.0 was used. The geometric mean blood lead levels was $2.93\;{\mu}g/{\ell}$ and nobody showed levels over the guidelines of WHO. Ex-smokers and current-smokers showed significantly higher blood lead levels compared to that of non-smokers. The blood lead levels in individuals with a history of working in a mine was higher than those in individuals without such histories. The populations resident in some Chungbuk abadoned mine area showed low levels of lead in blood. This suggest that lead poisoning might not be induced by abandoned mine in Chungbuk, Korea.

Association of Homocysteine Levels With Blood Lead Levels and Micronutrients in the US General Population

  • Lee, Yu-Mi;Lee, Mi-Kyung;Bae, Sang-Geun;Lee, Seon-Hwa;Kim, Sun-Young;Lee, Duk-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • 제45권6호
    • /
    • pp.387-393
    • /
    • 2012
  • Objectives: Even though several epidemiological studies have observed positive associations between blood lead levels and homocysteine, no study has examined whether this association differs by the levels of micronutrients, such as folate, vitamin B6, and vitamin B12, which are involved in the metabolism of homocysteine. In this study, we examined the interactions between micronutrients and blood lead on homocysteine levels. Methods: This study was performed with 4089 adults aged ${\geq}20$ years old in the US general population using the National Health and Nutrition Examination Survey 2003-2004. Results: There were significant or marginally significant interactions between micronutrients and blood lead levels on mean homocysteine levels. Positive associations between blood lead and homocysteine were clearly observed among subjects with low levels of folate or low vitamin B6 (p-trend <0.01, respectively). However, in the case of vitamin B12, there was a stronger positive association between blood lead and homocysteine among subjects with high levels of vitamin B12, compared to those with low levels of vitamin B12. In fact, the levels of homocysteine were already high among subjects low in vitamin B12, irrespective of blood lead levels. When we used hyperhomocysteinemia (homocysteine>15 ${\mu}mol/L$) as the outcome, there were similar patterns of interaction, though p-values for each interaction failed to reach statistical significance. Conclusions: In the current study, the association between blood lead and homocysteine differed based on the levels of folate, vitamin B6, or vitamin B12 present in the blood. It may be important to keep sufficient levels of these micronutrients to prevent the possible harmful effects of lead exposure on homocysteine levels.

친환경 소화기용 탄심 재료 및 2중 구조 설계 분석 (Design and Performance Analysis of Environment Friendly Double Core Bullets for Small Arms)

  • 홍준희;장탁순;송창빈;김병인
    • 한국군사과학기술학회지
    • /
    • 제14권2호
    • /
    • pp.264-270
    • /
    • 2011
  • This paper focuses on possibility to design and fabrication new combination of bullet core to substitute current toxic material of heavy metal such as lead by environment-friendly ones. The core is designed as dual structure to manipulate the core center of gravity easily by combining materials, which of basis is tungsten of low cost and easily acquired. Those combinations are W-M series such as W-Cu, W-Sn, W-Cu-Sn, and W-Cu-Ni to target the density of lead, $11.34g/cm^3$ through powder-metallurgy. Out of four, combination of W-Cu-Ni shows the highest compression density of 96% and is confirmed as the most suitable substitution for lead due to the excellent property of matter and sintering. All combination samples is simulated on the PRODAS software for designing and structure analysis by adjusting the center of gravity of dual core samples forward and backward. The simulations confirm the similarity of current bullet core with respect to properties of mass, aero dynamics, and flying stability.