• 제목/요약/키워드: current cost

검색결과 3,921건 처리시간 0.028초

소프트웨어 개발비 기준의 애플리케이션 유형과 품질 및 특성 보정요소 개선 (Improving the Application Type and Quality/Characteristics Adjustment Factors of the Korea Software Cost Estimation Standard)

  • 박찬규;김우제;서용원
    • 한국IT서비스학회지
    • /
    • 제8권2호
    • /
    • pp.43-70
    • /
    • 2009
  • As software development and maintenance cost increase quickly, information systems managers are more concerned about how to effectively manage software cost. To estimate the software development cost, most public institutes of Korea use the software cost estimation standard established by the government. Unfortunately, the accuracy of the estimation derived from the standard has not been satisfactory in spite of repetitive modifications made to improve it. One of the major reasons for the inaccuracy is that the standard has too small a number of cost adjustment factors to reflect the various characteristics of a software development project. To remedy this problem, we propose new cost adjustment factors which can be incorporated into the standard and are important to enhance the estimation accuracy, based on the analysis of several well-known software estimation models. Furthermore, by applying the proposed model to real world software projects, we show that the proposed model can produce more accurate estimates than the current standard.

Low Cost Rotor Fault Detection System for Inverter Driven Induction Motor

  • Kim, Nam-Hun;Choi, Chang-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권4호
    • /
    • pp.500-504
    • /
    • 2007
  • In this paper, the induction motor rotor fault diagnosis system using current signals, which are measured using axis-transformation method, and speed, which is estimated using current information, are presented. In inverter-fed motor drives unlike line-driven motor drives the stator currents have numerous harmonics components and therefore fault diagnosis using stator currents is very difficult. The current and speed signal for rotor fault diagnosis needs to be precise. Also, high resolution information, which means the diagnosis system, demands additional hardware such as low pass filter, high resolution ADC, encoder and etc. Therefore, the proposed axis-transformation and speed estimation method are expected to contribute to low cost fault diagnosis systems in inverter-fed motor drives without the need for an encoder and any additional hardware. In order to confirm validity of the developed algorithms, various experiments for rotor faults are tested and the line current spectrum of each faulty situation using Park transformation and speed estimation method are compared with the results obtained from fast Fourier transforms.

소규로 태양광 발전시스템을 위한 전류보상기법을 갖는 향상된 MPP 추적 컨버터 (An Improved MPPT Converter with Current Compensateion Method for Small Scaled PV-Applications)

  • 노형주;이동윤;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.580-583
    • /
    • 2002
  • An improved MPPT converter with current compensation method for small-scaled PV-applications is presented in this paper. The proposed method implements maximum power point tracking (MPPT) by variable reference current which is continuously changed during one sampling period. Therefore, the power transferred to the load is increased above $9\%$ by the proposed MPPT converter with current compensation method. As a result, the utilization efficiency of Photovoltaic (PV)-panel can be increased. In addition, as it doesn't use digital signal processor (DSP), this MPPT method has the merits of both a cost efficiency and a simple control circuit design. Therefore, it is considered that the proposed MPPT method is proper to low power, low cost PV-applications. The concept and control principles of the proposed MPPT method are explained in detail and its validity of the proposed method is verified through several simulated results.

  • PDF

Low-Cost SVM-DTC Strategy of Induction Machine Drives Using Single DC-link Current Sensor

  • Wang, Wei;Cheng, Ming;Hua, Wei;Ding, Shichuan;Zhu, Ying;Zhao, Wenxiang
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권3호
    • /
    • pp.266-273
    • /
    • 2012
  • In conventional direct torque control (DTC) using space-vector modulation (SVM) of induction machine (IM) drives, at least three current sensors are needed. In this paper, a low-cost SVM-DTC strategy is proposed, in which only a single current sensor is used. The position of the voltage space vector is divided into two areas: effective and non-effective area. If it is located in the non-effective area, the voltage space vector will be shifted into the effective area with minimum distortion. Further, the switching frequency remains constant. The simulation is carried out on a MATLAB/Simulink platform and the simulated results verify the effectiveness of the proposed strategy.

초전도에너지 저장장치의 운전주기에 따른 최적교류손실 결정에 관한 연구 (Optimum AC losses Determination for Duty Cycle of Superconductive Magnetic Energy Storage)

  • Hwang, Seuk-Yong
    • 대한전기학회논문지
    • /
    • 제39권7호
    • /
    • pp.653-667
    • /
    • 1990
  • Superconductor is consolidated, for required current capacity, with proper numbers of basic strands which are multifilamentary composites. Althouth superconductors are perfectly loss-free under DC conditions of current and field, AC losses occur under time-varying condition of the current and field. The AC losses are a controllable inherent characteristics of supercondectors. The AC losses dependent on the changing rate of current and field can be reduced by reducing the filament diameter. On the other hand, finer filament results in manufacturing cost increase. Therefore, in this paper optimization technique of superconductor for SMES is proposed from the viewpoint of AC loss reduction and manufacturing cost increase. The case study shows that the technique can be effectively used for the design of superconductor for SMES, appreciating the influence of various parameters related to superconductor itself and operating condition of SMES. As a result of the case study, it is confirmed that the technique is more effective for the design of superconductor for SMES for electric power power system stabilization rather then SMES for energy storage.

  • PDF

능동 전력 필터에 의한 유도모터 구동 전류형 인버터의 구형파 전류보상 (A Square Wave Current Compensation of Current Source Induction Motor drives Using Active Power Filter)

  • 정영국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.133-136
    • /
    • 2000
  • Current Source Inverter(CSI) operated in square wave mode is more efficient than the PWM CSI because of increased cost greater complexity of control algorithm, and substantial switching losses EMI. But the square wave output current of CSI rich in low order harmonics produce motor torque ripples. Therefore in this paper describes the active power filters for square wave current compensation of current source induction motor. Also extended current synchronous detection(ECSD) as compensation algorithm is proposed. To confirm the validity o proposed system some simulation results are presented and discussed.

  • PDF

저가형 교류전동기 벡터제어 인버터를 위한 새로운 전류측정 방법 (A Novel Current Sensing Method for Low-Cost Vector-Controlled Inverter of AC Motor)

  • 이원일;윤덕용
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.950-955
    • /
    • 2013
  • This paper proposes a new low-cost current detection method to implement vector-controlled inverter of 3-phase induction motor or permanent-magnet synchronous motor using 2 shunt resistors instead of expensive Hall current sensors. The proposed method can detect perfect phase currents without current-immeasurable area in all operating conditions of motor. This method uses 2 shunt resistors in Hall current sensor positions conventionally used to detect phase currents. Therefore, it requires accurate analog differential amplifiers to detect voltages across shunt resistors at high electric potential to ground. We show the good solutions which are implemented by voltage-divider resistors networks and the instrumentation amplifiers using several Op Amps at cheap price. Computer simulations and experiments were performed to confirm the effectiveness of proposed method. These results show that proposed method can perfectly detect phase currents without current-immeasurable area in all operating conditions of motor.

간단한 전류원 형태의 구조를 갖는 새로운 PDP 에너지 회수 회로 (A simple energy recovery circuit with current-fed type for plasma display panel (PDP))

  • 이강현;한상규;최성욱;김정은;문건우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.376-379
    • /
    • 2005
  • High efficiency and low cost sustain driver for plasma display panel (PDP) with current fed is proposed. Main concept of the proposed circuit is using the current source to charge and discharge panel. As a result, all power switches can achieve the zero voltage switching (ZVS) and every auxiliary switch can also do the zero current switching (ZCS). Moreover, since the inductor current can compensate the discharge current, the current stress of all power switches can be reduced considerably. Furthermore, it has features as a simpler structure, less mass, less cost, and lower electromagnetic interference than prior circuit.

  • PDF

Current Sensorless MPPT Control Method for Dual-Mode PV Module-Type Interleaved Flyback Inverters

  • Lee, June-Hee;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.54-64
    • /
    • 2015
  • This paper presents a current sensorless maximum power point tracking (MPPT) control method for dual-mode photovoltaic (PV) module-type interleaved flyback inverters (ILFIs). This system, called the MIC (Module Integrated Converter), has been recently studied in small PV power generation systems. Because the MIC is an inverter connected to one or two PV arrays, the power system is not affected by problems with other inverters. However, since the each PV array requires an inverter, there is a disadvantage that the initial installation cost is increased. To overcome this disadvantage, this paper uses a flyback inverter topology. A flyback inverter topology has an advantage in terms of cost because it uses fewer parts than the other transformer inverter topologies. The MPPT control method is essential in PV power generation systems. For the MPPT control method, expensive dc voltage and current sensors are used in the MIC system. In this paper, a MPPT control method without current sensor where the input current is calculated by a simple equation is proposed. This paper also deals with dual-mode control. Simulations and experiments are carried out to verify the performance and effectiveness of the proposed current sensorless MPPT control method on a 110 [W] prototype.

뇌혈관질환 환자군의 가정간호 행위묶음 수가연구 (Estimation of Home Care Nursing Cost to the Patient with Cerebrovascular Disease based on a Bundle of Home Care Nursing Service)

  • 홍진의;윤순녕
    • 가정∙방문간호학회지
    • /
    • 제7권1호
    • /
    • pp.26-38
    • /
    • 2000
  • The purpose of this study was to estimate home care nursing cost for the patient with Cerebrovascular Disease based on a bundle of home care nursing services This study was conducted through four steps. The first step was to investigate home care nursing activities that were offered to the patient with Cerebrovascular Disease(CD) by home care nurse. The second step was to investigate the time spent on home care nursing service and to calculate labor and manufacturing cost. The third step was to calculate home care nursing cost per minute. And at the fourth step, home care nursing cost for a patient with Cerebrovascular Disease based on a bundle of home care nursing service was calculated. The results of the study were as follows: 1) The number of direct home care nursing activities for the patient with CD was 108, and the time of each activity was spent from 1 to 10 minutes. 2) Average time per visit was 51 minute, and the firs visit time were spent 1.6 times higher than 2nd visit time. 3) Nursing cost per minute(cost per visit ${\\}\;22,565\;\div\;$ average time per visit 51 minutes) was ${\\}\;442$. The cost per visit was calculated on Basic visiting cost(nurse's labor cost ${\\}\;15,760$ + management cost ${\\}\;6,805$) divided by average time per visit(51 minutes). 4) Home care nursing cost to the patient with CD based on bundle of home care nursing service was consisted of basic home care nursing cost, the cost of a bundle of service practiced on visit. and transportation fee. Basic home nursing cost(the time spent on basic home nursing service 20 minutes ${\times}$ nursing cost per minute ${\\}\;442$) was ${\\}\;8,840$. The cost of the bundle of home care nursing services to the patient with CD was calculated as self care ${\\}\;2.898$, Tracheostomy care ${\\}\;10,166$, immobility care ${\\}\;6,188$, sore care ${\\}\;6,188$. Foley care ${\\}\;6,630$, and Levin tube or Gastrostomy care ${\\}\;7.514$. Transportation fee which was composed of the labor cost for transportation(${\\}\;5,122$) and the car management cost(${\\}\;3.876$) was ${\\}\;8,998$. Home care nursing cost to the patient with CD based on bundle of home care nursing services consisted of basic home care nursing cost, the cost of a bundle of service practiced on visit, and transportation fee. It will contribute to improve quality of home care service, because of giving appreciate incentives to home care nurses. And it will be more efficient than current cost of hospital based home care. But it need to management than calculation of the current fee-for-services of home care.

  • PDF