Radiation Measurement of a Operational CANDU Reactor Fuel Handling Machine using Semiconductor Sensors (ICCAS 2003)

  • Lee, Nam-Ho;Kim, Seung-Ho;Kim, Yang-Mo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1220-1224
    • /
    • 2003
  • In this paper, we measured the radiation dose of a fuel handling machine of the CANDU type Wolsong nuclear reactor directly during operation, in spite of the high radiation level. In this paper we will describe the sensor development, measurement techniques, and results of our study. For this study, we used specially developed semiconductor sensors and matching dosimetry techniques for the mixed radiation field. MOSFET dosimeters with a thin oxide, that are tuned to a high dose, were used to measure the ionizing radiation dose. Silicon diode dosimeters with an optimum area to thickness ratio were used for the radiation damage measurements. The sensors are able to distinguish neutrons from gamma/X-rays. To measure the radiation dose, electronic sensor modules were installed on two locations of the fuel handling machine. The measurements were performed throughout one reactor maintenance cycle. The resultant annual cumulative dose of gamma/X-rays on the two spots of the fuel handling machine were 18.47 Mrad and 76.50 Mrad, and those of the neutrons were 17.51 krad and 60.67 krad. The measured radiation level is high enough to degrade certain cable insulation materials that may result in electrical insulation failure.

  • PDF

The association of rectal equivalent dose in 2 Gy fractions (EQD2) to late rectal toxicity in locally advanced cervical cancer patients who were evaluated by rectosigmoidoscopy in Faculty of Medicine, Chiang Mai University

  • Tharavichtikul, Ekkasit;Meungwong, Pooriwat;Chitapanarux, Taned;Chakrabandhu, Somvilai;Klunklin, Pitchayaponne;Onchan, Wimrak;Wanwilairat, Somsak;Traisathit, Patrinee;Galalae, Razvan;Chitapanarux, Imjai
    • Radiation Oncology Journal
    • /
    • 제32권2호
    • /
    • pp.57-62
    • /
    • 2014
  • Purpose: To evaluate association between equivalent dose in 2 Gy (EQD2) to rectal point dose and gastrointestinal toxicity from whole pelvic radiotherapy (WPRT) and intracavitary brachytherapy (ICBT) in cervical cancer patients who were evaluated by rectosigmoidoscopy in Faculty of Medicine, Chiang Mai University. Materials and Methods: Retrospective study was designed for the patients with locally advanced cervical cancer, treated by radical radiotherapy from 2004 to 2009 and were evaluated by rectosigmoidoscopy. The cumulative doses of WPRT and ICBT to the maximally rectal point were calculated to the EQD2 and evaluated the association of toxicities. Results: Thirty-nine patients were evaluated for late rectal toxicity. The mean cumulative dose in term of EQD2 to rectum was 64.2 Gy. Grade 1 toxicities were the most common findings. According to endoscopic exam, the most common toxicities were congested mucosa (36 patients) and telangiectasia (32 patients). In evaluation between rectal dose in EQD2 and toxicities, no association of cumulative rectal dose to rectal toxicity, except the association of cumulative rectal dose in EQD2 >65 Gy to late effects of normal tissue (LENT-SOMA) scale ${\geq}$ grade 2 (p = 0.022; odds ratio, 5.312; 95% confidence interval, 1.269-22.244). Conclusion: The cumulative rectal dose in EQD2 >65 Gy have association with ${\geq}$ grade 2 LENT-SOMA scale.

Fluoroscopic Radiation Exposure during Percutaneous Kyphoplasty

  • Choi, Hyun-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권1호
    • /
    • pp.37-42
    • /
    • 2011
  • Objective: The author measured levels of fluoroscopic radiation exposure to the surgeon's body based on the different beam directions during kyphoplasty. Methods: This is an observational study. A series of 84 patients (96 vertebral bodies) were treated with kyphoplasty over one year. The patients were divided into four groups based on the horizontal and vertical directions of the X-Ray beams. We measured radiation exposure with the seven dosimetry badges which were worn by the surgeon in each group (total of 28 badges). Twenty-four procedures were measured in each group. Cumulative dose and dose rates were compared between groups. Results: Fluoroscopic radiation is received by the operator in real-time for approximately 50% (half) of the operation time. Thyroid protectors and lead aprons can block radiation almost completely. The largest dose was received in the chest irrespective of beam directions. The lowest level of radiation were received when X-ray tube was away from the surgeon and beneath the bed (dose rate of head, neck, chest, abdomen and knee: 0.2986, 0.2828, 0.9711, 0.8977, 0.8168 mSv, respectively). The radiation differences between each group were approximately 2.7-10 folds. Conclusion: When fluoroscopic guided-KP is performed, the X-Ray tube should be positioned on the opposite side of the operator and below the table, otherwise the received radiation to the surgeon's body would be 2.7-10 times higher than such condition.

DIFFERENTIAL EXPRESSION OF RADIATION RESPONSE GENES IN SPLEEN, LUNG, AND LIVER OF RATS FOLLOWING ACUTE OR CHRONIC RADIATION EXPOSURE

  • Jin, Hee;Jin, Yeung Bae;Lee, Ju-Woon;Kim, Jae-Kyung;Lee, Yun-Sil
    • Journal of Radiation Protection and Research
    • /
    • 제40권1호
    • /
    • pp.25-35
    • /
    • 2015
  • We analyzed the differential effects of histopathology, apoptosis and expression of radiation response genes after chronic low dose rate (LDR) and acute high dose rate (HDR) radiation exposure in spleen, lung and liver of rats. Female 6-week-old Sprague-Dawley rats were used. For chronic low-dose whole body irradiation, rats were maintained for 14 days in a $^{60}Co$ gamma ray irradiated room and received a cumulative dose of 2 Gy or 5 Gy. Rats in the acute whole body exposure group were exposed to an equal dose of radiation delivered as a single pulse ($^{137}Cs$-gamma). At 24 hours after exposure, spleen, lung and liver tissues were extracted for histopathologic examination, western blotting and RT-PCR analysis. 1. The spleen showed the most dramatic differential response to acute and chronic exposure, with the induction of substantial tissue damage by HDR but not by LDR radiation. Effects of LDR radiation on the lung were only apparent at the higher dose (5 Gy), but not at lower dose (2 Gy). In the liver, HDR and LDR exposure induced a similar damage response at both doses. RT-PCR analysis identified cyclin G1 as a LDR-responsive gene in the spleen of rats exposed to 2 Gy and 5 Gy gamma radiation and in the lung of animals irradiated with 5 Gy. 2. The effects of LDR radiation differed among lung, liver, and spleen tissues. The spleen showed the greatest differential effect between HDR and LDR. The response to LDR radiation may involve expression of cyclin G1.

방사선량률 예측을 위한 기계학습 기반 모델 개발 및 최적화 연구 (Machine Learning Based Model Development and Optimization for Predicting Radiation)

  • 이시현;이홍연;염정민
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.551-557
    • /
    • 2023
  • In recent years, radiation has become a socially important issue, increasing the need for accurate prediction of radiation levels. In this study, machine learning-based models such as Multiple Linear Regression (MLR), Random Forest (RF), XGBoost, and LightGBM, which predict the dose rate by time(nSv h-1) by selecting only important variables, were used, and the correlation between temperature, humidity, cumulative precipitation, wind direction, wind speed, local air pressure, sea pressure, solar radiation, and radiation dose rate (nSv h-1) was analyzed by collecting weather data and radiation dose rate for about 6 months in Jangseong, Jeollanam-do. As a result of the evaluation based on the RMSE (Root Mean Squared Error) and R-Squared (R-Squared coefficient of determination) scores, the RMSE of the XGBoost model was 22.92 and the R-Squared was 0.73, showing the best performance among the models used. As a result of optimizing hyperparameters of all models using the GridSearch method and comparing them by adding variables inside the measuring instrument, it was confirmed that the performance improved to 2.39 for RMSE and 0.99 for R-Squared in both XGBoost and LightGBM.

A Study to Compare the Radiation Absorbed Dose of the C-arm Fluoroscopic Modes

  • Cho, Jae-Hun;Kim, Jae-Yun;Kang, Joo-Eun;Park, Pyong-Eun;Kim, Jae-Hun;Lim, Jeong-Ae;Kim, Hae-Kyoung;Woo, Nam-Sik
    • The Korean Journal of Pain
    • /
    • 제24권4호
    • /
    • pp.199-204
    • /
    • 2011
  • Background: Although many clinicians know about the reducing effects of the pulsed and low-dose modes for fluoroscopic radiation when performing interventional procedures, few studies have quantified the reduction of radiation-absorbed doses (RADs). The aim of this study is to compare how much the RADs from a fluoroscopy are reduced according to the C-arm fluoroscopic modes used. Methods: We measured the RADs in the C-arm fluoroscopic modes including 'conventional mode', 'pulsed mode', 'low-dose mode', and 'pulsed + low-dose mode'. Clinical imaging conditions were simulated using a lead apron instead of a patient. According to each mode, one experimenter radiographed the lead apron, which was on the table, consecutively 5 times on the AP views. We regarded this as one set and a total of 10 sets were done according to each mode. Cumulative exposure time, RADs, peak X-ray energy, and current, which were viewed on the monitor, were recorded. Results: Pulsed, low-dose, and pulsed + low-dose modes showed significantly decreased RADs by 32%, 57%, and 83% compared to the conventional mode. The mean cumulative exposure time was significantly lower in the pulsed and pulsed + low-dose modes than in the conventional mode. All modes had pretty much the same peak X-ray energy. The mean current was significantly lower in the low-dose and pulsed + low-dose modes than in the conventional mode. Conclusions: The use of the pulsed and low-dose modes together significantly reduced the RADs compared to the conventional mode. Therefore, the proper use of the fluoroscopy and its C-arm modes will reduce the radiation exposure of patients and clinicians.

Radiation Dose Distribution of a Surgeon and Medical Staff during Orthopedic Balloon Kyphoplasty in Japan

  • Ono, Koji;Kumasawa, Takafumi;Shimatani, Keiichi;Kanou, Masatoshi;Yamaguchi, Ichiro;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • 제47권2호
    • /
    • pp.86-92
    • /
    • 2022
  • Background: The present study investigated the radiation dose distribution of balloon kyphoplasty (BKP) among surgeons and medical staff, and this is the first research to observe such exposure in Japan. Materials and Methods: The study subjects were an orthopedic surgeon (n = 1) and surgical staff (n = 9) who intervened in BKP surgery performed at the National Hospital Organization Disaster Medical Center (Tokyo, Japan) between March 2019 and October 2019. Only disposable protective gloves (0.022 mmPb equivalent thickness or less) and trunk protectors were used, and no protective glasses or thyroid drapes were used. Results and Discussion: The surgery time per vertebral body was 36.2 minutes, and the fluoroscopic time was 6.8 minutes. The average exposure dose per vertebral body was 1.46 mSv for the finger (70 ㎛ dose equivalent), 0.24 mSv for the lens of the eye (3 mm dose equivalent), 0.11 mSv for the neck (10 mm dose equivalent), and 0.03 mSv for the chest (10 mm dose equivalent) under the protective suit.The estimated cumulative radiation exposure dose of 23 cases of BKP was calculated to be 50.37 mSv for the fingers, 8.27 mSv for the lens, 3.91 mSv for the neck, and 1.15 mSv for the chest. Conclusion: It is important to know the exposure dose of orthopedic surgeons, implement measures for exposure reduction, and verify the safety of daily use of radiation during surgery and examination.

심장혈관 조영술과 심장혈관 인터벤션의 환자 선량 평가 (Patient Radiation Dose Values During Interventional Cardiology Examinations in University Hospital, Korea)

  • 김정수;이종혁;정혜경;김정민;조병렬
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.27-33
    • /
    • 2016
  • 심장혈관 조영술과 인터벤션은 현대 성인병의 증가로 급격히 증가하고 있다. 심장혈관 인터벤션은 장시간 동일 부위에 방사선을 조사하는 검사로 방사선으로 인한 피부상해를 일으킬 수 있다. 본 연구에서는 의료기관의 심장혈관 인터벤션의 진단참조준위를 조사하여 환자의 피폭선량을 감소시키는 도구로 사용하고자 한다. 본 연구는 147명의 환자에서 심장혈관 조영술과 인터벤션을 대상으로 누적 투시시간, 누적 투시면적선량, 영상촬영을 위한 면적선량, 누적 면적선량, 공기커마, 동영상 수, 총 영상 수에 대한 정보를 획득하여 진단참조준위를 설정하였다. 심장혈관 조영술의 진단참조준위와 인터벤션의 진단참조준위에 해당하는 면적선량 값은 각각 $44.4 Gy{\cdot}cm2$$298.6Gy{\cdot}cm2$로 나타났고 투시시간에 대한 진단참조준위는 각각 191.5 sec와 1935.3 sec로 나타났다. 진단참조준위는 반드시 넘으면 안 되는 값은 아니다. 하지만 진단참조준위를 제정하여 의료 기관에서 사용하고 있는 선량의 참조 값을 설정하고 이를 검토하는 과정은 환자의 불필요한 피폭선량을 감소시키는데 기여할 것이다.

IDENTIFICATION OF GENES EXPRESSED IN LOW-DOSE-RATE γ-IRRADIATED MOUSE WHOLE BRAIN

  • Bong, Jin Jong;Kang, Yu Mi;Choi, Seung Jin;Kim, Dong-Kwon;Lee, Kyung Mi;Kim, Hee Sun
    • Journal of Radiation Protection and Research
    • /
    • 제38권4호
    • /
    • pp.166-171
    • /
    • 2013
  • While high-dose ionizing radiation results in long term cellular cytotoxicity, chronic low-dose (<0.2 Gy) of X- or ${\gamma}$-ray irradiation can be beneficial to living organisms by inducing radiation hormesis, stimulating immune function, and adaptive responses. During chronic low-dose-rate radiation (LDR) exposure, whole body of mice is exposed to radiation, however, it remains unclear if LDR causes changes in gene expression of the whole brain. Therefore, we aim to investigate expressed genes (EGs) and signaling pathways specifically regulated by LDR-irradiation ($^{137}Cs$, a cumulative dose of 1.7 Gy for total 100 days) in the whole brain. Using microarray analysis of whole brain RNA extracts harvested from ICR and AKR/J mice after LDR-irradiation, we discovered that two mice strains displayed distinct gene regulation patterns upon LDR-irradiation. In ICR mice, genes involved in ion transport, transition metal ion transport, and developmental cell growth were turned on while, in AKR/J mice, genes involved in sensory perception, cognition, olfactory transduction, G-protein coupled receptor pathways, inflammatory response, proteolysis, and base excision repair were found to be affected by LDR. We validated LDR-sensitive EGs by qPCR and confirmed specific upregulation of S100a7a, Olfr624, and Gm4868 genes in AKR/J mice whole brain. Therefore, our data provide the first report of genetic changes regulated by LDR in the mouse whole brain, which may affect several aspects of brain function.

병원 내 방사선 작업종사자의 만성적 방사선 피폭에 의한 혈액학적 성분 변화에 관한 연구 (Occupational Radiation Exposure to Hospital Workers: On the Effect of Hematological Change)

  • 류재광;정우영;신상기;조시만;동경래;김현수
    • 핵의학기술
    • /
    • 제12권3호
    • /
    • pp.157-170
    • /
    • 2008
  • 본 연구는 의료기관에 종사하는 의료방사선 작업종사자에게서 직업적 방사선 피폭으로 인한 인체 내 생리적인 변화를 통해 만성적 저선량 방사선피폭의 위험도를 예측하며 현 수준의 변화 상태를 파악하기 위한 목적으로 서울시내 일개 대형병원에서 최근 1~9년간 방사선 작업종사자로 근무한 370명을 대상으로 남녀 간의 체내 혈액성분의 수치변화를 대조군과의 비교 분석을 실시하여 다음과 같은 결론을 얻었다. 1. 종사자의 1~9년간 평균 방사선 누적선량은 남자가 $9.65{\pm}15.2\;mSv$, 여자가 $4.89{\pm}5.55\;mSv$로 남자에서 높았으며 이는 통계적으로도 유의하였다(p<0.01). 2. 남녀 종사자 모두에서 누적선량과 종사기간의 차이에 따른 검사항목들과의 상관성은 매우 미약하였다(r<${\pm}0.25$) 3. 종사기간이 증가할수록 남자에서는 백혈구의 감소자와 증가자, 혈색소의 감소자, 당질의 증가자 비율 유의하게 높았으며(p<0.05), 여자에서도 백혈구의 감소 및 증가자, 호산구의 감소자의 비율이 유의하게 높았다(p<0.01). 4. 누적선량의 증가할수록 남녀모두에서 오히려 이상분포를 보이는 항목은 줄어들었으며, 남자는 림프구와 혈소판의 감소자가 유의하게 높았고(p<0.05) 여자는 림프구와 적혈구의 감소뿐만 아니라 종사기간에서 이상을 보였던 백혈구의 감소 및 증가자 역시 유의한 증가를 나타냈다(p<0.05). 5. 전체적인 변화를 보면 남자 종사자에서는 혈액성분 중 적혈구, 혈소판, 림프구가 주로 감소되며 백혈구는 감소와 증가양상을 같이 보였다. 화학성분 중 당질의 증가가 유의했지만 큰 의미는 없었다. 여자 종사군에서는 남자와 똑같게 백혈구가 감소, 증가 양상을 동시에 보였으며 그밖에 적혈구와 림프구, 호산구의 감소가 유의했다. 이상의 결과를 종합해보면 비록 낮은 선량에 피폭이 되고 있는 의료방사선 종사자일지라도 방사선 피폭에 있어서는 자유롭지 못하여 그 영향으로 인한 체내 생물학적 변화를 겪을 수 있으며 그 변화는 선량에 의존하기 보다는 다분히 확률적일 수 있다는 사실이다. 그러므로 항상 미연에 피폭을 방지하기 위한 노력을 종사자 스스로 기울임을 물론 관련 당국 또한 종사자들의 건강을 체계적으로 관리할 수 있는 시스템을 하루빨리 구축하여 방사선 피폭으로 인한 직업병의 발생의 우려를 없애야 할 것으로 사료된다.

  • PDF