• 제목/요약/키워드: cryogenic engineering

검색결과 492건 처리시간 0.023초

티타늄 합금 소재 저속 영역 극저온 가공 특성 연구 (Study on Characteristics of Cryogenic Machining Process of Titanium Alloy at a Low Cutting Speed)

  • 김도영;김동민;박형욱
    • 한국정밀공학회지
    • /
    • 제34권4호
    • /
    • pp.237-241
    • /
    • 2017
  • Cryogenic machining uses liquid nitrogen (LN2) as a coolant. This machining process can reduce the cutting temperature and increase tool life. Titanium alloys have been widely used in the aerospace and automobile industries because of their high strength-to-weight ratio. However, they are difficult to machine because of their poor thermal properties, which reduce tool life. In this study, we applied cryogenic machining to titanium alloys. Orthogonal cutting experiments were performed at a low cutting speed (1.2 - 2.1 m/min) in three cooling conditions: dry, cryogenic, and cryogenic plus heat. Cutting force and friction coefficients were observed to evaluate the machining characteristics for each cooling condition. For the cryogenic condition, cutting force and friction coefficients increased, but decreased for the cryogenic plus heat condition.

Pressure-volume-temperature gauging method experiment using liquid nitrogen under microgravity condition of parabolic flight

  • Seo, Mansu;Park, Hana;Yoo, DonGyu;Jung, Youngsuk;Jeong, Sangkwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권2호
    • /
    • pp.64-69
    • /
    • 2014
  • Measuring an exact amount of remaining cryogenic liquid propellant under microgravity condition is one of the important issues of rocket vehicle. A Pressure-Volume-Temperature (PVT) gauging method is attractive due to its minimal additional hardware and simple gauging process. In this paper, PVT gauging method using liquid nitrogen is investigated under microgravity condition with parabolic flight. A 9.2 litre metal cryogenic liquid storage tank containing approximately 30% of liquid nitrogen is pressurized by ambient temperature helium gas. During microgravity condition, the inside of the liquid tank becomes near-isothermal condition within 1 K difference indicated by 6 silicon diode sensors vertically distributed in the middle of the liquid tank. Helium injection with higher mass flow rate after 10 seconds of the waiting time results in successful measurements of helium partial pressure in the tank. Average liquid volume measurement error is within 11% of the whole liquid tank volume and standard deviation of errors is 11.9. As a result, the applicability of PVT gauging method to liquid propellant stored in space is proven with good measurement accuracy.

Helium guard system design for HIAF iLinac cryogenic distribution system

  • Xianjin Wang;Shuping Chen;Wen Jun;Dajun Fan;Liming Zhu;Yanan Lib;Xiaofei Niu;Junhui Zhang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권1호
    • /
    • pp.6-10
    • /
    • 2023
  • 2 K superfluid helium cryogenic system is the crucial component of many large accelerators. When the cryogenic system is operating at 2K@3129Pa, many room-temperature parts are connected to superfluid helium via tubes. Air Leakage in these connections may lead to air contamination of the cryogenic system. Air contamination may cause equipment failure in cryogenic systems and, in extreme cases, render the entire accelerator system inoperable. Helium guard is a technique that guards against air contamination of these sub-atmospheric pressure connections in 2 K superfluid helium cryogenic system. This paper introduces a typical 2 K cryogenic distribution design for large accelerators, and make risk analysis of air contamination. Finally, the analysis of specific leakage points and detailed engineering design are presented, which may be used as a reference when designing of a 2 K superfluid helium cryogenic distribution system.

극저온용 액중펌프 구조해석에 관한 연구 (A Study on the Structural Analysis of Cryogenic Submerged Pump)

  • 진도훈;이중섭
    • 한국산업융합학회 논문집
    • /
    • 제23권5호
    • /
    • pp.727-733
    • /
    • 2020
  • Recently, reciprocating cryogenic pumps are mainly developed for small-and-mid sized fuel supply systems. Centrifugal type pumps are not actively developed. Most cryogenic submerged pumps are imported. For transportation, cryogenic liquefied natural gas requires the liquid pump technology that can works in extreme evironments. In order to transport liquefied natural gas, it is necessary to apply pump technology. This is the fundamental research for developing the submerged pump technology applicable to the transportation and storage system equipment of cryogenic liquefied system. It tries to secure basic design materials through reverse-engineering in the cryogenic submerged pump development. Regarding materials, STS-304 and STS-431 which are stainless materials widely used in the cryogenic area are applied. Aluminum alloy is applied to impeller and upper manifolder and the pump rotates at the high speed of 6,000rpm.

극저온 볼 밀링을 통한 Ibuprofen 분말의 마이크로화 (Micronization of Ibuprofen by Cryogenic Ball Milling)

  • 조현갑;이경엽;백영남;박훈재;이상목
    • 한국정밀공학회지
    • /
    • 제21권11호
    • /
    • pp.195-199
    • /
    • 2004
  • For the present study, the cryogenic ball milling process was applied to make Ibuprofen microsized. The cryogenic ball milling was performed at low temperature of about -18$0^{\circ}C$ for 6 hours. The particle size distribution was determined before and after the cryogenic process. X-ray diffraction (XRD) measurement was made to determine the effect of cryogenic process on the crystallinity of Ibuprofen. The results showed that the size of Ibuproffn was reduced about 10 times by the cryogenic process. The degree of crystallinity of Ibuproffn was slightly reduced by the cryogenic process.

극저온 열처리 공정이 6061 알루미늄 합금의 잔류응력과 인장특성에 미치는 영향 (Effects of Cryogenic Treatment on Residual Stress and Tensile Properties for 6061 Al Alloy)

  • 박기정;고대훈;김병민;임학진;이정민;조영래
    • 대한금속재료학회지
    • /
    • 제49권1호
    • /
    • pp.9-16
    • /
    • 2011
  • To develop a 6061 aluminum alloy with low residual stress and high tensile strength, a cryogenic treatment process was investigated. Compared to the conventional heat treatment process for precipitation hardening with artificial aging, the cryogenic treatment process has two additional steps. The first step is cryogenic quenching of the sample into liquid nitrogen, the second step is up-hill quenching of the sample into boiling water. The residual stress for the sample was measured by the $sin^2{\psi}$ method with X-ray diffraction. The 6061 aluminum alloy sample showed 67% relief in stress at the cryogenic treatment process with artificial aging at $175^{\circ}C$. From this study, it was found that the optimum cryogenic treatment process for a sample with low residual stress and high tensile strength is relatively low cooling speed in the cryogenic quenching step and a very high heating speed in the up-hill quenching step.

극저온 LNG 배관냉각 특성에 대한 연구 (A Study on Cryogenic Line Chill Down Characteristics of LNG)

  • 변병창;김경중;정상권;김모세;이상윤;이근태;김동민
    • 한국수소및신에너지학회논문집
    • /
    • 제33권6호
    • /
    • pp.808-818
    • /
    • 2022
  • In this research paper, we investigated the cryogenic line chill down characteristics of liquefied natural gas (LNG). A numerical analysis model was established and verified so that it can calculate the precise cooling characteristics of cryogenic fluid for the stable and safe utilization especially such as LNG and liquid hydrogen. The numerical modeling was programmed by C++ as an one-dimensional homogeneous model. The thermohydraulic cooling process was simulated using mass, momentum, energy conservation equations and appropriate heat transfer correlations. In this process, the relevant heat transfer correlations for nuclear boiling, transition boiling, film boiling, and single-phase heat transfer that can predict the experimental results were implemented. To verify the numerical modeling, several cryogenic line chill down experiments using LNG were conducted at the Korea Institute of Machinery & Materials (KIMM) LNG and Cryogenic Technology Center.

극저온 유체 화물창 방벽 내의 액체유동 및 기화 시뮬레이션 (LIQUID FLOW AND EVAPORATION SIMULATION OF CRYOGENIC FLUID IN THE WALL OF CRYOGENIC FLUID CARGO CONTAINMENT SYSTEM)

  • 박범진;이희범;이신형;배준홍;이경원;정왕조;안상준
    • 한국전산유체공학회지
    • /
    • 제14권2호
    • /
    • pp.9-18
    • /
    • 2009
  • The cargo containment system (CCS) for ships carrying cryogenic fluid consists of at least two levels of barriers and insulation layers. It is because, even though there is a small amount of leak through the primary barrier, the liquid tight secondary barrier blocks further leakage of the cryogenic fluid. However, once the secondary barrier is damaged, it is highly possible that the leaked cryogenic fluid flows through the flat joint made of glass wool and reaches the inner hull of the ship. The primary objective of the present study is to investigate the influence of the damage extent in the secondary barrier on the amount of leaked cryogenic fluid reaching the inner hull and the temperature distribution there. Simulation results using a computational fluid dynamics tool were compared with the experimental data for the leaked cryogenic fluid flow and evaporation in the secondary insulation layer. The experimental and computational results suggest that, unless there is a massive leak, the cryogenic fluid mostly evaporates in the insulation layer and does not reach the inner hull in the state of liquid.

Transparent cryogenic thermosiphon using $N_2\;and\;CF_4$ mixture as the working fluid

  • Lee, Ji-Sung;Jeong, Sang-Kwon;Ko, Jun-Seok;Kim, Young-Kwon;Jung, Se-Yong;Han, Young-Hee
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권2호
    • /
    • pp.37-40
    • /
    • 2009
  • A mixed working fluid has a potential to widen the operation temperature range of the thermosiphon. In this study, the thermosiphon using $N_2\;and\;CF_4$ mixture as the working fluid is fabricated and tested to verify its transient thermo hydraulic characteristic. A transparent pyrex glass tube was used for the thermosiphon itself and the vacuum chamber was also fabricated by glass to visualize the internal state of thermo siphon. Onset of condensation temperature was related to the partial pressure of $CF_4$. Two solidifications were observed and condensate temperature range of mixed working fluid was from 160K to 70.7K with $N_2$ 25% composition.

극저온 볼 밀링을 통한 Ibuprofen 분말의 나노화II (Nanocrystallization of Ibuprofen by Cryogenic Ball Milling II)

  • 조현갑;이경엽;백영남;박훈재;이상목
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.442-446
    • /
    • 2004
  • Reducing the particle size of drug materials down to submicron is an important matter in pharmaceutical industry. Cryogenic milling technology is one of the mechanical milling processes, which is mostly utilized in refining grain size of metal and ceramics at extremely low temperature environment. This technique has not been readily studied in application to medical and biotechnology. This paper, therefore, describes the application of cryogenic milling process to reduce particle size of Ibuprofen. The shape and size of the Ibuprofen particle before and after the cryogenic ball milling process were analyzed. XRD analysis was performed to examine a change in crystallinity of Ibuprofen by the cryogenic ball milling process. The results showed that the size of Ibuprofen particles was reduced to 1/10 or less of its initial size. The results also showed that the degree of crystallinity of Ibuprofen was slightly reduced after cryogenic ball milling with nitrogen

  • PDF