• Title/Summary/Keyword: cryogenic

Search Result 1,145, Processing Time 0.028 seconds

Analysis of Trace Impurities in The Bulk Gases by a Cold Concentration Method (저온 농축법에 의한 극미량 성분 가스분석)

  • Lee Taeck-Hong;Hong So Young;Jung Woo Chan;Kim Young Rak;Suh Jung Woo;Han Ju Tack;Park Doo Seon;Son Moo Ryong
    • 한국가스학회:학술대회논문집
    • /
    • 1997.09a
    • /
    • pp.260-265
    • /
    • 1997
  • Analysis of trace impurities in the bulk .gas has been very important with the development of semi-conductor related industry. In the paper, we reported the analysis of the trace impurites of carbon monoxide and methane in the bulk helium and hydrogen by the GC-TCD with a cold nitrogen trap. We compared these results by the paraallel analysis. All data showed a good correspondence, showing reliable statistical error ranges.

  • PDF

Study on Characteristics of Cryogenic Machining Process of Titanium Alloy at a Low Cutting Speed (티타늄 합금 소재 저속 영역 극저온 가공 특성 연구)

  • Kim, Do Young;Kim, Dong Min;Park, Hyung Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.4
    • /
    • pp.237-241
    • /
    • 2017
  • Cryogenic machining uses liquid nitrogen (LN2) as a coolant. This machining process can reduce the cutting temperature and increase tool life. Titanium alloys have been widely used in the aerospace and automobile industries because of their high strength-to-weight ratio. However, they are difficult to machine because of their poor thermal properties, which reduce tool life. In this study, we applied cryogenic machining to titanium alloys. Orthogonal cutting experiments were performed at a low cutting speed (1.2 - 2.1 m/min) in three cooling conditions: dry, cryogenic, and cryogenic plus heat. Cutting force and friction coefficients were observed to evaluate the machining characteristics for each cooling condition. For the cryogenic condition, cutting force and friction coefficients increased, but decreased for the cryogenic plus heat condition.

Effect of Cryogenic Treatment on Wear Resistance of STD 11 Steel (STD 11강 마모특성에 미치는 서브제로처리의 영향)

  • Hong, Young Hwan;Song, Keun
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.16 no.3
    • /
    • pp.134-140
    • /
    • 2003
  • Effects of cryogenic treatment and tempering temperature on the amount of retained austenite, hardness and wear properties has been investigated using alloy tool steel, STD 11. Cryogenic treatments were performed at the temperatures of $-100^{\circ}C$, $-150^{\circ}C$ and $-196^{\circ}C$, and tempering were performed at $200^{\circ}C$ and $530^{\circ}C$. It was shown that lower hardness value was obtained on high temperature ($530^{\circ}C$) tempering even after cryogenic treatment. And retained austenite was not entirely transformed to martensite after cryogenic treatment even at $-196^{\circ}C$, which was not consistent with the belief that $-80^{\circ}C$ was sufficient to entirely transform any austenite retained in the quenched microstructure. Austenite retained in cryogenic treated condition was completely transformed to martensite only after tempering at $530^{\circ}C$. As far as wear test conditions in this investigation, it was found that cryogenic treatments improved the sliding wear resistance, but improvement of wear resistance was not directly related with retained austenite contents. And it was found that predominent wear mechanisms of STD 11 steel were oxidation wear and adhesive wear In sliding wear conditions.

Effects of Cryogenic Treatment on Residual Stress and Tensile Properties for 6061 Al Alloy (극저온 열처리 공정이 6061 알루미늄 합금의 잔류응력과 인장특성에 미치는 영향)

  • Park, Kijung;Ko, Dea Hoon;Kim, Byung Min;Lim, Hak Jin;Lee, Jung Min;Cho, Young-Rae
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.1
    • /
    • pp.9-16
    • /
    • 2011
  • To develop a 6061 aluminum alloy with low residual stress and high tensile strength, a cryogenic treatment process was investigated. Compared to the conventional heat treatment process for precipitation hardening with artificial aging, the cryogenic treatment process has two additional steps. The first step is cryogenic quenching of the sample into liquid nitrogen, the second step is up-hill quenching of the sample into boiling water. The residual stress for the sample was measured by the $sin^2{\psi}$ method with X-ray diffraction. The 6061 aluminum alloy sample showed 67% relief in stress at the cryogenic treatment process with artificial aging at $175^{\circ}C$. From this study, it was found that the optimum cryogenic treatment process for a sample with low residual stress and high tensile strength is relatively low cooling speed in the cryogenic quenching step and a very high heating speed in the up-hill quenching step.

Design and manufacture of horn lens antennas of 80 GHz MM wave FMCW radar for cryogenic fluids level measurement

  • Jeon, S.M.;Mun, J.M.;Lee, S.C.;Sim, K.D.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.1
    • /
    • pp.29-33
    • /
    • 2022
  • Recently, development of a cryogenic fluids storage tank for storing or transporting liquid hydrogen is actively in progress. In cryogenic fluids storage tanks, hydrogen evaporates due to the extreme temperature difference inside and outside the tank. As the mass of the cryogenic fluids changes with continuous vaporization, the fluids level also changes. Therefore, there is need for a method of accurately measuring the level change in the storage tank. In the case of general cryogenic fluids, it is difficult to accurately measure the level because the dielectric constant is very low. As a method of measuring cryogenic fluids level with low dielectric constant, it can be used an Millimeter wave (MM wave) FMCW radar sensor. However, the signal sensitivity is very weak and the level accuracy is poor. In this paper, the signal sensitivity is improved by designing the horn lens antenna of the existing 80 GHz FMCW radar sensor. Horn lens antenna is fabricated by FDM/SLA type 3D printer according to horn and lens characteristics. The horn is used to increase the signal gain and the lens improves the signal straightness. This makes it possible to measure the level of cryogenic fluids with a low dielectric constant.

Design and Characteristics of cryogenic ball valve (초저온 볼 밸브 설계 및 특성)

  • Kim, Dong-Soo;Kim, Myoung-Sub
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.666-671
    • /
    • 2007
  • To acquire the safety along with durability of mechanical machinery products, we should consider the structural mechanics such as stress, deformation and dynamic vibration characteristics and identify those important aspects in the stage of preliminary design engineering. This cryogenic ball valve is used to transfer the liquified natural gas which temperature is $-196^{\circ}C$, supplied pressure is $168kg/cm^2$. For the cryogenic ball valve, the assurance of structural integrity and operability are essential to meet not only normal, abnormal loading conditions but also functionality during a seismic event. In this thesis, analytical approach and results using finite element analysis and computational method are herein presented to evaluate the aspects of structural integrity along with operability of cryogenic ball valve. In this study, we designed the high pressure cryogenic ball valve that accomplishes zero leakage by elastic seal at normal temperature and metal seal at high temperature.

  • PDF

Precision Hard Turning with Cryogenic Cooling (액화질소를 이용한 고정도 하드 터닝)

  • 박영우;김기수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.1048-1051
    • /
    • 2001
  • This paper presents an analytical and experimental study of a cryogenic machining for precision hard turning. A cryogenic circulation system is designed and mounted on the top of the tool insert. The machining process used is facing operation on a CNC turning center with dry and cryogenic conditions. The tool temperature and cutting forces are measured by the K-type thermocouple and by a three-component Kistler dynamometer, respectively. Both data are fed into the data acquisition program through an A/D card. Surface roughness and form accuracy of the machined surface are measured by WYKO NT2000. It is also found that surface roughness and form accuracy with cryogenic cooling are better than those with no coolant.

  • PDF

Conceptual design of cryogenic turbo expander for 10 kW class reverse Brayton refrigerator

  • Lee, Chang Hyeong;Kim, Dong Min;Yang, Hyung Suk;Kim, Seokho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.3
    • /
    • pp.41-46
    • /
    • 2015
  • Recently, the development of the HTS power cable is actively promoted. As the length of HTS power cable increases, there have been many efforts to develop large capacity cryocooler. Among the various cryocooler, the Brayton refrigerator is the most competitive for HTS power cable. The Brayton refrigerator is composed of recuperative heat exchangers, a compressor, and a cryogenic turbo expander. In these components, the cryogenic turbo expander is a part to decrease the temperature and it is the most significant component that is closely related with overall system efficiency. It rotates with high speed using a high-pressure helium or neon gas at cryogenic temperature. This paper describes the design of a 10 kW class Brayton refrigeration cycle and the cryogenic turbo expander. Flow and structural analysis are performed for the rotating impeller and nozzle to verify the efficiency and the design performance.