• 제목/요약/키워드: cryogen

검색결과 38건 처리시간 0.025초

Simple predictive heat leakage estimation of static non-vacuum insulated cryogenic vessel

  • Mzad, Hocine
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권3호
    • /
    • pp.25-30
    • /
    • 2020
  • The diminishing of heat leak into cryogenic vessels can prolong the storage time of cryogenic liquid. With the storage of cryogenic liquid reducing, the heat leak decreases, while the actual storage time increases. Regarding to the theoretical analysis, the obtained results seems to be constructive for the cryogenic insulation system applications. This study presents a predictive assessment of heat leak occurring in non-vacuum tanks with a single layer of insulation. A Radial steady-state heat transfer, based on heat conduction equation, is taken into consideration. Graphical results show the thermal performance of the insulation used, they also allow us to choose the appropriate insulation thickness according to the shape and diameter of the storage tank.

고온초전도 동기 전동기 (High Temperature Superconducting Synchronous Motor)

  • 조영식;흥정표;권영길;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.574-576
    • /
    • 2001
  • This paper deals with High Temperature Superconducting (HTS) Motor, which have two characteristics: the HTS magnet with iron plates as field coil, and the solid nitrogen $(SN_2)$ as a cryogen. The HTS magnet has iron plates to achieve the maximum current-carrying capacity and the simple shape that can easily be wound and jointed. The HTS magnet with iron plates, magnet optimized current distribution, and initial magnet are presented through 3 Dimensional Finite Element Analysis (3D FEA), manufacturing and testing these magnets. And, it is employed $SN_2$ for keep the operating temperature of HTS synchronous motor. To make the liquid nitrogen $(LN_2)$ of $SN_2$, Gas helium (GHe) passes into the heat exchanger and cools its own temperature. Two types of heat exchangers are designed and manufactured to make the $SN_2$, and each of the temperature characteristics is compared.

  • PDF

Roebuck 냉동기를 응용한 회전형 헬륨 재응축 장치 (Rotating helium-recondensing system using Roebuck refrigerator)

  • 정상권;이창규
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.464-471
    • /
    • 1999
  • This paper describes a design of the helium-recondensing system utilizing cascade Roebuck refrigerators. Superconducting generator or motor has the superconducting field winding in its rotor that should be continuously cooled by cryogen. Since liquid helium transfer from the stationary system to the rotor is problematic, cumbersome, and inefficient, the novel concept of a rotating helium-recondensing system is contrived. The vaporized cold helium inside the rotor is isothermally compressed by centrifugal force and expanded sequentially in cascade refrigerators until the helium is recondensed at 4.2K. There is no helium coupling between the rotor and the stationary liquid helium storage. Thermodynamic analysis of the cascade refrigeration system is performed to determine the key design parameters. The loss mechanisms are also explained to identify entropy generation that degrades the performance of the system.

  • PDF

고체질소 냉각 고온초전토 동기기용 회전자의 온도특성 (Temperature Characteristic of Rotor of HTS Synchronous Machine cooled by Solid Nitrogen)

  • 조영식;홍정표;이주;심기덕;손명환;권영길;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.95-97
    • /
    • 2001
  • This paper deals with cryogen, which is used solid nitrogen to keep the operating temperature of High Temperature Superconducting (HTS) synchronous machine. To make the solid nitrogen of liquid nitrogen, liquid helium (LHe) passes into and cools the heat exchanger to its own temperature. Two types of heat exchangers are designed and manufactured to make the solid nitrogen, and temperature characteristics of those compare with each other. The rotor cooled by latent heat of solid nitrogen and it is kept under 40K during 2 hours and 30 minutes without LHe.

  • PDF

Experimental study on natural circulation using liquid nitrogen for superconducting applications

  • Choi, Yeon Suk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권3호
    • /
    • pp.49-52
    • /
    • 2013
  • An experiment to investigate the natural circulation of a cryogen has been performed. The study is motivated mainly by our recent development of cryogenic cooling system for prototype superconducting cyclotron without any circulating pump. In the natural circulation loop system, a cooling channel is attached on the outer surface of the aluminium block and the liquid nitrogen passes through inside of the channel to cool the block indirectly. A cryocooler as a heat sink is located at the top to re-condense cryogenic vapor coming from the aluminium block in which electrical heater is installed as a heat source. The main dimensions are determined using the relevant analysis and the natural circulation loop is successfully fabricated. The temperature distributions in the loop are measured during initial cool-down process and in steady state, from which the modified Grashof numbers are calculated and compared with the existing correlation estimated with one-dimensional analysis for steady state flow.

Measurement of thermal contact resistance at Cu-Cu interface

  • Kim, Myung Su;Choi, Yeon Suk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권2호
    • /
    • pp.48-51
    • /
    • 2013
  • The thermal contact resistance (TCR) is one of the important components in the cryogenic systems. Especially, cryogenic measurement devices using a cryocooler can be affected by TCR because the systems have to consist of several metal components in contact with each other for heat transferring to the specimen without cryogen. Therefore, accurate measurement and understanding of TCR is necessary for the design of cryogenic measurement device using a cryocooler. The TCR occurs at the interface between metals and it can be affected by variable factors, such as roughness of metal surface, contact area and contact pressure. In this study, we designed TCR measurement system at various temperatures using a cryocooler as a heat sink and used steady state method to measure the TCR between metals. The copper is selected as a specimen in the experiment because it is widely used as a heat transfer medium in the cryogenic measurement devices. The TCR between Cu and Cu is measured for various temperatures and contact pressures. The effect of the interfacial materials on the TCR is also investigated.

A STUDY ON DEGREASING DETERGENT AND METHOD FOR THE IPP TEST FACILITY

  • Kim Yong-Wook;Lee Jung-Ho;Kang Sun-Il;Kim Sang-Heon;Oh Seung-Hyub
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2004년도 한국우주과학회보 제13권2호
    • /
    • pp.262-265
    • /
    • 2004
  • As a cryogen, LOx is a light blue, odorless, transparent liquid. Also it is not shock sensitive and does not decompose. However, it is a strong oxidizer and will vigorously support combustion. Therefore all harmful contaminants (such as grease, oil, fingerprint and organic materials) that could cause malfunctions, fires, or explosions in a oxygen environments must be completely removed prior to the introduction of oxygen. Especially, grease ingredient located inside of the LOx supply line, pipe and PHS (Pneumo-Hydraulic System) part can make drastic chemical reaction with oxygen. Therefore, to protect rapid reaction such as explosion, grease ingredient must be surely eliminated by a regular and irregular degreasing. Study on the availability, effectiveness and selection of degreasing detergents and method is described in this paper, and it will be useful for the construction and management of IPP test facility.

  • PDF

Helium Recondensing System Utilizing Cascade Roebuck Refrigerators

  • Jeong, Sang-Kwon;Lee, Chang-Gyu;Jung, Je-Heon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.108-118
    • /
    • 2000
  • This paper describes a design of the helium-recondensing system utilizing cascade Roebuck refrigerators. Superconducting generator or motor has the superconducting field wind-ing in its rotor that should be continuously cooled by cryogen. Since liquid helium transfer from the stationary system to the rotor is problematic, cumbersome, and inefficient, the novel concept of a rotating helium-recondensing system is contrived. The vaporized cold helium inside the rotor is isothermally compressed by centrifugal force and expanded sequentially in cascade refrigerators until the helium is recondensed at 4.2 K. There is no helium coupling between the rotor and the stationary liquid helium storage. Thermodynamic analysis of the cascade refrigeration system is performed to determine the key design parameters. The loss mechanisms are explained to identify entropy generation that degrades the performance of the system.

  • PDF

Flux Pinning Properties of REBCO coated conductors for High Field Magnets

  • Awaji, Satoshi;Watanabe, Kazuo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권4호
    • /
    • pp.1-4
    • /
    • 2011
  • From the viewpoint of high field application, the mechanical and critical current properties of recently developed $REBa_2Cu_3O_y$ (RE123, RE: rare-earth) coated conductors are summarized. In addition, effective flux pinning mechanisms in RE123 are also introduced. As one of the examples for high field application, the upgrading of the 18 T cryogen-free superconducting magnet is shown. The large anisotropy of $J_c$ is a problem at low temperature and high magnetic field. The nanorod is considered as the useful methods to improve the anisotropy of $J_c$, although its efficiency becomes small at low temperature.

고온 초전도 SMES용 전도냉각시스템 특성시험 (Test of the Conduction Cooling System for HTS SMES)

  • 염한길
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권1호
    • /
    • pp.62-66
    • /
    • 2008
  • The characteristic of the superconducting magnetic energy storage(SMES) system is faster response, longer life time, more economical, and environment friendly than other uninterruptible power supply(UPS) using battery. So, the SMES system can be used to develop methods for improving power quality where a short interruption of power could lead to a long and costly shutdown. Recently, cryogen free SMES has developed using BSCCO(Bismuth Strontium Calcium Copper Oxide) wire. We fabricated and tested the conduction cooling system for the 600 kJ class HTS SMES. The experiment was accomplished for the simulation coils. The simulation coils were made of aluminium, it is equivalent to thermal mass of 600 kJ HTS SMES coil. The coil is cooled with two GM coolers through the copper conduction bar. In this paper, we report that the test results of cool-down and heat loads characteristics of the simulation coils. The developed conduction cooling system adapted to 600 kJ HTS SMES system and cope with the unexpected sudden heat impact, too.