• Title/Summary/Keyword: crown-root angle

Search Result 29, Processing Time 0.027 seconds

A STUDY ON CALCIFICATION OF THE SECOND MOLARS IN ANGLE CLASS I MALOCCLUSION (Angle I 급 부정교합자의 제2대구치 석회화 과정에 관한 연구)

  • Suhr, Cheong Hoon
    • The korean journal of orthodontics
    • /
    • v.13 no.2
    • /
    • pp.201-204
    • /
    • 1983
  • To study the calcification of second molars in Class I malocclusion with normal craniofacial structure, the author examined cephalograms, orthopantomograms, periapical films of 538 children from 7 y 0 m to 15y 11m old who had Class I malocclusion with normal craniofacial structure, and observed the calcification stage of upper and lower second molars. The results are as follows. 1. The mean ages of crown completion of upper and lower second molars are $8.82{\pm}1.14,\;8.72{\pm}0.75$ in boys, and $8.60{\pm}1.46,\;8.22{\pm}0.92$ in girls. 2. The mean ages of root completion of upper and lower second molars are $14.25{\pm}1.46,\;14.15{\pm}0.83$ in boys, and $14.12{\pm}0.93,\;14.15{\pm}0.83$ in girls. 3. There are no difference between the calcification stages of upper second molars and those of lower second molars in both sexes.

  • PDF

A COMPARATIVE STUDY ON RELIABILITY OF THE ROOT PARALLELISM OF THE POSTERIOR TEETH PROJECTED ON THE ORTHOPANTOMOGRAM WITH THE $45^{\circ}$ OBLIQUE CEPHALOGRAM (Orthopantomogram과 $45^{\circ}$ 측모두부 방사선 사진과의 구치부 치근평행도의 신뢰도에 관한 비교연구)

  • Min, Young-Gyu;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.23 no.3 s.42
    • /
    • pp.359-374
    • /
    • 1993
  • At present, many orthodontists regard the root parallelism of the posterior teeth important not only in diagnosis and treatment planning but also for predicting posttreatment stability. To evaluate it, they usually refer to the orthopantomogram. At this study, 97 samples were collected from students of Yonsei University, who have well-proportioned face, Angle's class I canine & molar relationships and no crown axis deviation of the posterior teeth including canines. Reliability of the root parallelism observed from orthopantomogram was evaluated by comparison with $45^{\circ}$ oblique cephalogram. The results were as follows : 1. In comparing the differences between anglular measurements in $45^{\circ}$ oblique cephalogram & orthopantomogram with $5^{\circ}$, those to mandibular plane were significantly less than to occlusal plane in number of items which showed less differences than $5^{\circ}$. 2. Compared the root parallelisms in the orthopantomogram with those in $45^{\circ}$ oblique cephalogram with $1\%$ significance level, parallelism between upper canine & 1st premolar, lower canine & 1st premolar, lower 1st premolar & 2nd premolar, and lower right 2nd molar & 3rd molar showed statistically significant differences. 3. When the significance between the differences of the root parallelism between above two kinds of film and $5^{\circ}$ was verified by two sided paired t-test, more or less large difference was shown between lower right 2nd molar & 3rd molar, a little larger than $5^{\circ}$ between lower canine & 1st premolar, smaller at the rest of them. 4. In $45^{\circ}$ oblique cephalogram, lower canine & 1st premolar showed convergent root arrangements each other, while in orthopantomogram they were divergent each other. All the others except them showed convergency on the upper, divergency on the lower in both films.

  • PDF

SCANNING ELECTRON MICROSCOPIC STUDY ON THE EFFICACY OF ROOT CANAL WALL DEBRIDEMENT OF ROTARY NI-TI INSTRUMENTS WITH DIFFERENT CUTTING ANGLE (엔진 구동형 니켈-타이타늄 합금파일의 절삭각에 따른 근관성형 효과에 관한 전자현미경적 연구)

  • Jeon, In-Soo;Yoon, Tai-Cheol;Park, Seong-Ho;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.6
    • /
    • pp.577-586
    • /
    • 2002
  • The purpose of this in vitro study was to compare the effects of root canal cleanness following two Ni-Ti rotary instruments with different rake angle. Thirty-six sound, extracted human premolars with single root were randomly divided into three groups. The used rotary instruments were HEROShaper (Group 1, Micro-Mega, Besancon, France, n=12) and ProFile (Group 2, Maillefer, Ballaigues, Switzerland, n=12). Control group (n=12) was only extirpated with barbed broach (Mani, Matsutani Seisakusho Co., Japan) Group 1 & 2 teeth were prepared to a #40/.04 taper at the apex followed by 1 mm using crown-down technique. After canal preparation and frequent irrigation with 5.25% sodium hypochlorite, the roots split longitudinally into a bucco-lingual direction. Root halves were cross-sectioned in apical third portion again. All root specimens were processed for SEM investigation and photographed. Separate evaluations by one endodontist were undertaken for smear layer on prepared walls with a five score-index for each using reference photograph in root halves. The penetration depth of smear layer into dentinal tubules was also estimated in the other halves. Following results were obtained: 1. Smear layer was observed on all the prepared walls with two experimental groups except control group. 2. Smear layer characteristics in two experimental groups; 1) HEROShaper group showed snowy, dusty appearance and were shown open dentinal tubuli on the prepared walls of almost specimens, and the thickness of smear layer covering onto dentinal surfaces was within 1-2 ${\mu}m$ in a few specimens. 2) ProFile group showed shiny, burnished appearance and complete root canal wall covered by a homogenous smear layer with no open dentinal tubuli in all specimens. The penetration of smear layer into dentinal tubules was found in all specimens and the thickness was at 2-4 ${\mu}m$ in all specimens. These results demonstrated that a completely clean root canal could not be achieved regardless of positive or negative rake angle, which is in accordance with the majority of previous studies on root canal cleanliness In conclusion, through irrigation with antibacterial solutions or chelating agents is recommended to remove the smear layer on prepared canal wall in spite of Ni-Ti instrumentation.

A Finite Element Analysis of Incisors with Different Material Combinations of a Post and a Core (기둥(Post)과 핵(Core)의 이종재료 조합에 의한 치아의 유한요소해석)

  • Kang, Min-Kyu;Tak, Seung-Min;Lee, Seok-Soon;Seo, Min-Seock;Kim, Hyo-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.4
    • /
    • pp.474-481
    • /
    • 2011
  • The purpose of this study was to investigate the effect of rigidity of post core systems on stress distribution by the finite element stress analysis method. Three-dimensional finite element models simulating an endodontically treated maxillary central incisor restored with a zirconia crown were prepared. Each model contained cortical bone, trabecular bone, periodontal ligament, 4mm apical root canal filling, and post-and-core. A 50N static occlusal load was applied to the palatal surface of the crown with a $60^{\circ}$ angle to the long axis of the tooth. And three parallel type post (zirconia, glass fiber and stainless steel) and two core (Paracore and Tetric ceram) materials were evaluated, respectively. The differences in stress transfer characteristics of the models were analyzed. von Mises stresses were chosen for presentation of results and maximum displacement and hydrostatic pressure were also calculated. For the Result of the research, the model applied glass fiber to post material has lowest von Mises stress and it is suitable for material of post core systems.

Internal evaluation of provisional restorations according to the dental CAD/CAM manufacturing method : Three-dimensional superimpositional analysis (치과 CAD/CAM 가공방식에 따른 임시보철물의 내면 적합도 : 3차원 중첩 분석)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.81-86
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the internal fit of two different temporary restorations fabricated by dental CAD/CAM system and to evaluate clinical effectiveness. Methods: Composite resin tooth of the maxillary first molar was prepared as occlusal reduction(2.0mm), axial reduction(1mm offset), vertical angle(6 degree) and chamfer margin for a temporary crown and duplicated epoxy die was fabricated. The epoxy dies were used to fabricate provisional restorations by CAD/CAM milling technique or 3D-printing technique. The inner data from all crowns were superimposed on the master die file in the 'best-fit alignment' method using 3D analysis software. Statistical analysis was performed using a Wilcoxon's rank sum test for differences between groups. Results: It showed that the internal RMS(Root Mean Square) values of the additive group were significantly larger than those of other group. No significant differences in internal discrepancies were observed in the temporary crowns among the 2 groups with different manufacturing method. Conclusion: All the groups had the internal fit within the clinical acceptable range (< $50{\mu}m$). The continuous research in the future to be applied clinically for the adaptation of additive manufacturing technique are needed.

Morphological Measurements of Anatomic Landmarks in Human Mandibular Molar Pulp Chambers - An in vivo Study

  • Lokade, Joyti;Rawlani, Shivlal;Baheti, Rakhi (Chandak);Roy, Shelly;Chandak, Manoj;Lohe, Vidya
    • Journal of Korean Dental Science
    • /
    • v.4 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: Exact knowledge of the location and dimension of the pulp chamber help to maintain the pulp healthy during operative procedure and also reduces the risk of perforation of pulp chamber during root canal treatment. This in-vivo study was carried out to measure critical morphology of pulp chamber of mandibular molar using intra-oral periapical radiograph. Materials and Methods: Mandibular molar teeth of 56 patients were evaluated. The mandibular molar teeth whose pulp chamber was not violated by caries, restoration, fracture crown and those having closed apex were included in the study. The intraoral periapical radiographs were taken with paralleling angle technique using radio-opaque grid with 1 mm space. This grid was placed directly on the film. Results: In 94% of the mandibular first molars specimens the pulp chamber ceiling was at the level of the cemento-enamel junction. The measurements showing the lowest percentage variance were buccal cusp to furcation (approximately 11%) and buccal cusp to pulp chamber ceiling (approximately 15%). The distance from the cusp tip to pulp chamber ceiling height was approximately 6.0 mm, the distance from the pulpal floor to the furcation was approximately 3.0 mm, and the average height of a pulp chamber was 1.5 to 2.0 mm. Conclusion: The exact knowledge of distances of pulp chamber from various anatomical landmarks helps in proper assessment of root canals and ultimately avoids the failure of root canal treatment.

Anchor Plate Efficiency in Postoperative Orthodontic Treatment Following Orthognathic Surgery via Minimal Presurgical Orthodontic Treatment

  • Jeong, Tae-Min;Kim, Yoon-Ho;Song, Seung-Il
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.4
    • /
    • pp.154-160
    • /
    • 2014
  • Purpose: The efficiency of an anchor plate placed during orthognathic surgery via minimal presurgical orthodontic treatment was evaluated by analyzing the mandibular relapse rate and dental changes. Methods: The subjects included nine patients with Class III malocclusion who had bilateral sagittal split osteotomy at the Division of Oral and Maxillofacial Surgery, Department of Dentistry in Ajou University Hospital, after minimal presurgical orthodontic treatment. During orthognathic surgery, anchor plates were placed at both maxillary buttresses. The anchor plates were used to move maxillary teeth backward and for maximum anchorage of Class III elastics to minimize mandibular relapse during the postoperative orthodontic treatment. The lateral cephalometric X-ray was taken preoperatively (T0), postoperatively (T1), and one year after the surgery (T2). Seven measurements (distance from Pogonion to line Nasion-Nasion perpendicular [Pog-N Per.], angle of line B point-Nasion and Nasion-Sella [SNB], angle of line maxilla 1 root-maxilla 1 crown and Nasion-Sella [U1 to SN], distance from maxilla 1 crown to line A point-Nasion [U1 to NA], overbite, overjet, and interincisal angle) were taken. Measurements at T0 to T1 and T1 to T2 were compared and differences tested by standard statistical methods. Results: The mean skeletal change was posterior movement by $13.87{\pm}4.95mm$ based on pogonion from T0 to T1, and anterior movement by $1.54{\pm}2.18mm$ from T1 to T2, showing relapse of about 10.2%. There were significant changes from T0 to T1 for both Pog-N Per. and SNB (P<0.05). However, there were no statistically significant changes from T1 to T2 for both Pog-N Per. and SNB. U1 to NA that represents the anterior-posterior changes of maxillary incisor did not differ from T0 to T1, yet there was a significant change from T1 to T2 (P<0.05). Conclusion: This study found that the anchor plate minimizes mandibular relapse and moves the maxillary teeth backward during the postoperative orthodontic treatment. Thus, we conclude that the anchor plate is clinically very useful.

A Preliminary study of Biomechanical Behavior of High-Performance Polymer Post-Core System (고성능 폴리머 재질의 포스트-코어 시스템의 생역학적 거동에 대한 예비실험)

  • Lee, Ki-Sun;Kim, Jong-Eun;Kim, Jee-Hwan;Lee, Jeong-Yol;Shin, Sang-Wan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.2
    • /
    • pp.75-81
    • /
    • 2018
  • The aim of this study was to evaluate the biomechanical behavior and long-term safety of high performance polymer PEKK as an intraradicular dental post-core material through comparative finite element analysis (FEA) with other conventional post-core materials. A 3D FEA model of a maxillary central incisor was constructed. A cyclic loading force of 50 N was applied at an angle of $45^{\circ}$ to the longitudinal axis of the tooth at the palatal surface of the crown. For comparison with traditionally used post-core materials, three materials (gold, fiberglass, and PEKK) were simulated to determine their post-core properties. PEKK, with a lower elastic modulus than root dentin, showed comparably high failure resistance and a more favorable stress distribution than conventional post-core material. However, the PEKK post-core system showed a higher probability of debonding and crown failure under long-term cyclic loading than the metal or fiberglass post-core systems.

A STUDY ON STRESS DISTRIBUTION OF ENDODONTICALLY TREATED TOOTH ACCORDING TO THE VARIOUS POST LENGTH USINGTHREE-DIMENSIONAL FINITE ELEMENT METHOD (포스트 길이가 치근내 응력분산에 미치는 영향에 관한 삼차원 유한요소법적 연구)

  • Choi, Soo-Yong;Lee, Sun-Hyung;Yang, Jae-Ho;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.177-197
    • /
    • 1995
  • The endodontically treated tooth is generally restored with post & core, owing to the brittleness and the loss of large amount of tooth structure. Although there have been lots of studies about the endodontically treated teeth, the three-dimensional quantitative studies about the strees distribution of them are in rare cases. In this study, it was assumed that the coronal portion of the upper incisou had severely damaged. After the root canal therapy it was post cored, and restored with PFM crown, for this experiment nine types of model were constructed : 1); long, 2); medium, 3); short gold post for the roots supported with a narmal alveolar bone, 4); long, 5); medium, 6); short gold post for the roots supported with an alveolar bone resorbed to its 1/3 of root length, 7); long, 8); medium, 9); short base metal post for the roots supported with an alveolar bone resorbed to its 1/3 of root length. Force was applied from two directions. One was functional maximum bite force(300N) applied to the spot just lingual to the incisal edge with the angle of 45 degrees to the long axis of the tooth, and the other one was horizontal force(300N) applied to the labial surface. The results analyzed with three-dimensional finite element method were as follows : 1. Stress was concentrated on the middle portion of the labial side dentin of the root and the lingual portion of the apical dentin of the root. Stress in the post showed maximum value at 2 mm above the post apex. 2. In case of the long post and base metal post, strees was concentrated on the apex of the root and the post. 3. In case of the longer post, the displacement on the post-cement interface was lessened. The gold post was more displaceable than the base metal post. 4. In case of the alveolar bone resorption, stress concentrated on the root and the post and displacement on the post-cement interface were increased.

  • PDF

Comparison of shaping ability between single length technique and crown-down technique using Mtwo rotary file (Mtwo 전동 파일을 사용한 single length technique과 crown-down technique의 근관성형 효율 비교)

  • Lim, Yoo-Kyoung;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.385-396
    • /
    • 2007
  • The aims of this study were to compare the shaping effect and safety between single length technique recommended by manufacturer and crown-down technique using Mtwo rotary file and to present a modified method in use of Mtwo file. Sixty simulated root canal resin blocks were used. The canals were divided into three groups according to instrument and the manner of using methods. Each group had 20 specimens. Group MT was instrumented with single length technique of Mtwo, group MC was instrumented with crown-down technique of Mtwo and group PT was instrumented with crown-down technique of ProTaper. All of the rotary files used in this study were operated by an electric motor. The scanned canal images of before and after preparation were superimposed. These superimposed images were evaluated at apical 1 to 8 mm levels Angle changes were calculated. The preparation time, weight loss, instrument failure and binding, canal aberrations, and centering ratio were measured. Statistical analysis of the three experimental groups was performed with ANOVA and Duncan's multiple range tests for post-hoc comparison and Fisher's exact test was done for the frequency comparison. In total preparation time, group MT and group MC were less than group PT. In the aberrations, group MT had more elbows than those of group MC and group PT. The binding of group MC was least and group MT was less than group PT (P < 0.05). Under the condition of this study, crown-down technique using Mtwo rotary file is better and safer method than single length technique recommended by the manufacturer.