• Title/Summary/Keyword: crown shape control

Search Result 30, Processing Time 0.021 seconds

A Robust Design Study of Air Bearing Slider for HDD (HDD용 에어베어링 슬라이더의 강건설계에 관한 연구)

  • 전규찬;장동섭;좌성훈
    • Tribology and Lubricants
    • /
    • v.16 no.4
    • /
    • pp.247-252
    • /
    • 2000
  • As the demand for higher areal recording densities requires a lower flying height of the slider, the variation of the flying height of the slider during drive operation becomes of great concern. The variation of the flying height is closely related with the slider design parameters such as air bearing shape, cavity depth, shallow step depth, crown, camber, pitch offset, roll offset, gram load, and so on. The objective of this work is to optimize the cavity depth and the shallow step depth, which are the control factors in air bearing design, using Robust Design method. It was found that the shallow step depth was statistically significant in affecting the variation of flying height, therefore the level of the shallow step depth should be chosen to minimize the variation of flying height.

Wound Healing After Gingivectomy Using Pulsed Nd : YAG Laser In The Rat (백서에서 Pulsed Nd : YAG Laser에 의한 치은절제술후의 치유양상)

  • Kim, Ok-Su;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.293-308
    • /
    • 1996
  • Recently, dental laser have been applied for removal of soft tissues, hemostasis and blood coagulation, removal of benign and malignant tumor, treatment of leukoplakia, aphthous ulcer and herpetic lesion, implant second surgery, removal of granulation tissue, frenectomy, clinical crown lengthening, gingivectomy, gingivoplasty, and treatment of dentin hypersensitivity. Even though the frequency of laser treatment is increasing, the research on the healing process after gingivectomy using pulsed Nd : YAG laser is very rare. The purpose of this study was to observe and compare the wound healing after gingivectomy using scalpel and pulsed Nd : YAG laser in the rat. Gingivectomy was performed using pulsed Nd : YAG laser(SUNRISE Technologies, U.S.A., 1.5 Watts, 10 pps) on the buccal gingiva of right maxillary first molar and using scalpel(No.12) on the contralateral side. Those sites treated by surgical scalpel were designated as the control, and by pulsed Nd : YAG laser as the experimental group. Animals were sacrificed at 1, 2, 3, 5, 7, 11 and 14 days postoperatively, and specimens were histologically observed under light microscope. The results were as follows : 1. Clinical observation Normal color and shape were observed at the 5th day ill the control group and the 7th day in the experimental group. 2. Histologic findings 1) In the control group, denser inflammatory infiltration was observed. 2) Epithelialization started at the 2nd day in the control group, similar to the experimental group, and completed at the 11th to the 14th day postoperatively. 3) In the experimental group, connective tissue showed the vacuole formation and degenerative change during early healing period. Healing of connective tissue was slower in the experimental group than in the control group by 2 days. 4) In the both groups, wound healing was completed at the 2nd week. From this study, gingivectomy using pulsed Nd : YAG laser seems to result in a little delayed wound healing process, compared to the gingivectomy using scalpel. Considering the clinical advantages of laser surgery, pulsed Nd : YAG laser might be useful device for gingivectomy.

  • PDF

The study on advertisement of dental devices & instrument during Japanese colonized period (광고를 통해 본 일제강점기 치과 장비 및 기구 광고에 관한 연구)

  • Shin, Jai-Eui
    • The Journal of the Korean dental association
    • /
    • v.48 no.12
    • /
    • pp.893-918
    • /
    • 2010
  • This article is purposed of reviewing the development history of Japanese dental devices and instrument, and their related advertisement activities during the Japanese colonized period in Korea in early 20th century. Japanese dental devices and instrument were redesigned to accommodate their ergonomic shape above the simple imitation, and it implies the excessive desires brought them frustrations. The tragic earthquake on Sep. l, 1923, medical insurance law enforcement on Jan. 1, 1927, celebration of "Cavity prevention Day" started on Jun. 4, 1928, and the attack of Manchuria and China by Japan after 1931, all of these historical incidents become the preliminary requirement for the development of dental devices. On Nov. 1, 1937, Japanese government started to control dental materials, driving the campaigns for excluding foreign products and encourging the use of local products. In 1939, Nakajima dental manufacturers used this political and social atmosphere on their advertisement as saying "Our Nakajima's products have no compromise with the short raw materials, but only commitment to our quality". Since after 1940, the price and supply have been strongly under control, and the control group was appeared to manage all of supply and distribution of raw materials, regular price system, and specifications. At last, the Japanese national power were devastated in its production and distribution capacities, and get to the frustrated period. The main advertised dental devices and instruments in Korea during the Japanese colonized period were 1) dental chair, unit and cabinet, 2) dental x-ray, 3) compressors, 4) dental needles, 5) small instrument and carryon medical(emergency) kit, 6) oral hygiene and pyorrhea alveolaris, infrared rays, sunlight lamp, ultrashort wave treatment devices, 7)crown former, electric furnace, casting machine, articulator, electric lathe, and laboratory equipments, etc.

Effects of Varying Contact back-up Roll on the strip flatness (VCR 롤이 판평판도에 미치는 영향)

  • Chen, Xianlin;Zhang, Jie;Yang, Quan;Zhang, Quingdong
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1998.03a
    • /
    • pp.144-147
    • /
    • 1998
  • VCR is a back-up roll with a special contour which leads to the length of the contact line between back-up roll and work becones self adjustable in accordance with the width of the strip. The simulation of a finite element model and the on-line test at production mill demonstrate that the VCR roll may keep the crown of the roll gap relatively stable, and at same time, permit the rolling pressure to be adjusted over a wider range, and increase the effect of work roll bending on the roll gap. The VCR rolls have been successfully used at the first stands of two largest cold rolling mills in China, and on-line test has been done at a wide hot strip finishing train. The use of VCR roll has created favorable conditions for subsequent rolling passes and the achievement of better flatness quality.

  • PDF

The role of autophagy in cell proliferation and differentiation during tooth development

  • Ji-Yeon Jung;Shintae Kim;Yeon-Woo Jeong;Won-Jae Kim
    • International Journal of Oral Biology
    • /
    • v.48 no.4
    • /
    • pp.33-44
    • /
    • 2023
  • In this review, the regulatory mechanisms of autophagy were described, and its interaction with apoptosis was identified. The role of autophagy in embryogenesis, tooth development, and cell differentiation were also investigated. Autophagy is regulated by various autophagy-related genes and those related to stress response. Highly active autophagy occurrences have been reported during cell differentiation before implantation after fertilization. Autophagy is involved in energy generation and supplies nutrients during early birth, essential to compensate for their deficient supply from the placenta. The contribution of autophagy during tooth development, such as the shape of the crown and root formation, ivory, and homeostasis in cells, was also observed. Genes control autophagy, and studying the role of autophagy in cell differentiation and development was useful for understanding human aging, illness, and health. In the future, the role of specific mechanisms in the development and differentiation of autophagy may increase the understanding of the pathological mechanisms of disease and development processes and is expected to reduce the treatment of various diseases by modulating the autophagic phenomenon.

Effect of thread design on the marginal bone stresses around dental implant (임플란트 나사산 디자인이 변연골 응력에 미치는 영향)

  • Lee, Sang-Hyun;Jo, Kwang-Heon;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.316-323
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of different thread designs on the marginal bone stresses around dental implant. Materials and methods: Standard ITI implant(ITI Dental Implant System; Straumann AG, Waldenburg, Switzerland), 4.1 mm in diameter and 10 mm in length, was selected as control. Test implants of four different thread patterns were created based on control implant, i.e. maintaining all geometrical design of control implant except thread pattern. Four thread designs used in test implants include (1) small V-shape screw (model A), (2) large V-shape screw (model B), (3) buttress screw (model C), and (4) trapezoid screw (model D). Surface area for unit length of implant was 14.4 $mm^2$ (control), 21.7 (small V-shape screw), 20.6 (large V-shape screw), 17.0 (buttress screw) and 28.7 $mm^2$ (trapezoid screw). Finite element models of implant/bone complex were created using an axisymmetric scheme with the use of NISA II/DISPLAY III (Engineering Mechanics Research Corporation, Troy, MI, USA). A load of 100 N applied to the central node on the crown top either in parallel direction or at 30 degree to the implant axis (in order to apply non-axial load to the implant NKTP type 34 element was employed). Quantification and comparison of the peak stress in the marginal bone of each implant model was made using a series of regression analyses based on the stress data calculated at the 5 reference points which were set at 0.2, 0.4, 0.6, 0.8 and 1.0 mm from implant wall on the marginal bone surface. Results: Results showed that although severe stress concentration on the marginal bone cannot be avoided a substantial reduction in the peak stress is achievable using different thread design. The peak marginal bone stresses under vertical loading condition were 7.84, 6.45, 5.96, 6.85, 5.39 MPa for control and model A, B, C and D, respectively. And 29.18, 26.45, 25.12, 27.37, 23.58 MPa when subject to inclined loading. Conclusion: It was concluded that the thread design is an important influential factor to the marginal bone stresses.

Effects of cementless fixation of implant prosthesis: A finite element study

  • Lee, Hyeonjong;Park, Soyeon;Kwon, Kung-Rock;Noh, Gunwoo
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.341-349
    • /
    • 2019
  • PURPOSE. A novel retentive type of implant prosthesis that does not require the use of cement or screw holes has been introduced; however, there are few reports examining the biomechanical aspects of this novel implant. This study aimed to evaluate the biomechanical features of cementless fixation (CLF) implant prostheses. MATERIALS AND METHODS. The test groups of three variations of CLF implant prostheses and a control group of conventional cement-retained (CR) prosthesis were designed three-dimensionally for finite element analysis. The test groups were divided according to the abutment shape and the relining strategy on the inner surface of the implant crown as follows; resin-air hole-full (RAF), resin-air hole (RA), and resin-no air hole (RNA). The von Mises stress and principal stress were used to evaluate the stress values and distributions of the implant components. Contact open values were calculated to analyze the gap formation of the contact surfaces at the abutment-resin and abutment-implant interfaces. The micro-strain values were evaluated for the surrounding bone. RESULTS. Values reflecting the maximum stress on the abutment were as follows (in MPa): RAF, 25.6; RA, 23.4; RNA, 20.0; and CR, 15.8. The value of gap formation was measured from 0.88 to 1.19 ㎛ at the abutment-resin interface and 24.4 to 24.7 ㎛ at the abutment-implant interface. The strain distribution was similar in all cases. CONCLUSION. CLF had no disadvantages in terms of the biomechanical features compared with conventional CR implant prosthesis and could be successfully applied for implant prosthesis.

'Arihyang', a Strawberry Variety with Highly Firm and Large-Sized Fruit for Forcing Culture (촉성재배용 고경도 대과성 딸기 품종 '아리향')

  • Kim, Dae-Young;Kim, Seung Yu;Huh, Yun-Chan;Yoon, Moo Kyung;Lee, Sun Yi;Moon, Ji-Hye;Kim, Dae Hyun
    • Korean Journal of Breeding Science
    • /
    • v.50 no.4
    • /
    • pp.497-503
    • /
    • 2018
  • A strawberry variety 'Arihyang' was derived as an artificial cross between 'Tochiotome' and 'Seolhyang' in 2014. The seedling and line selections were conducted from 2014 to 2015. Preliminary and advanced yield trials of '14-5-5,' which was the final selected line, were conducted from 2015 to 2017. 'Arihyang' is suitable for forced cultivation and has strong plant vigor, uniformly large-sized fruit, and a high yield compared to those of the check variety, 'Seolhyang' and 'Maehyang.' Especially, vitamin C was at a significant level, which was approximately 15% higher than that of 'Seolhyang.' The average number of flowers per first flower cluster was 10.5, which could reduce the labor of thinning fruit. Its fruit has a conical shape, dark red color, and glossy skin. The fruit was of good quality but has recommendations for harvest at the fully ripened stage. 'Arihyang' has intermediate resistant to phytophthora crown rot, but is susceptible to powdery mildew, gray mold, anthracnose, and fusarium wilt. It is reguired to manage major diseases and pests using optimum cultivation techniques and chemical control.

Effect of abutment superimposition process of dental model scanner on final virtual model (치과용 모형 스캐너의 지대치 중첩 과정이 최종 가상 모형에 미치는 영향)

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.203-210
    • /
    • 2019
  • Purpose: The purpose of this study was to verify the effect of the abutment superimposition process on the final virtual model in the scanning process of single and 3-units bridge model using a dental model scanner. Materials and methods: A gypsum model for single and 3-unit bridges was manufactured for evaluating. And working casts with removable dies were made using Pindex system. A dental model scanner (3Shape E1 scanner) was used to obtain CAD reference model (CRM) and CAD test model (CTM). The CRM was scanned without removing after dividing the abutments in the working cast. Then, CTM was scanned with separated from the divided abutments and superimposed on the CRM (n=20). Finally, three-dimensional analysis software (Geomagic control X) was used to analyze the root mean square (RMS) and Mann-Whitney U test was used for statistical analysis (${\alpha}=.05$). Results: The RMS mean abutment for single full crown preparation was $10.93{\mu}m$ and the RMS average abutment for 3 unit bridge preparation was $6.9{\mu}m$. The RMS mean of the two groups showed statistically significant differences (P<.001). In addition, errors of positive and negative of two groups averaged $9.83{\mu}m$, $-6.79{\mu}m$ and 3-units bridge abutment $6.22{\mu}m$, $-3.3{\mu}m$, respectively. The mean values of the errors of positive and negative of two groups were all statistically significantly lower in 3-unit bridge abutments (P<.001). Conclusion: Although the number of abutments increased during the scan process of the working cast with removable dies, the error due to the superimposition of abutments did not increase. There was also a significantly higher error in single abutments, but within the range of clinically acceptable scan accuracy.

Crown Shape Control of Pinus koraiensis S. et Z. (VII) - The Influence of Thinning and Stem Pruning on Seed Component(The First Report) - (잣나무의 수형조절(VII) - 잣나무의 간벌과 수형조절이 종자의 성분에 미치는 영향(제1보) -)

  • Song, Jae-Mo;Shim, Tae-Heum;Yi, Jae-Seon
    • Journal of Forest and Environmental Science
    • /
    • v.18 no.1
    • /
    • pp.87-96
    • /
    • 2001
  • In order to investigate the influence of increased seed production of Korean white pine(Pinus koraiensis S. et Z.), component of seeds, produced from trees in the thinned stand and the stem-pruned trees in the seed orchard, were analyzed. The results obtained were as follows: 1. General component analysis of seed There is no significant influence of thinning on the seed component in moisture content (thinned- 4.10%, unthinned- 3.74% ), ash (thinned- 2.95%, unthinned- 2.94%), crude lipid (thinned- 67.62%, unthinned- 71.94%), and crude protein (thinned- 17.27%, unthinned- 17.50%). There is no significant influence of stem-pruning on the seed component in moisture content (unpruned- 4.26%, 1m stem-pruned- 4.10%, and 2m stem-pruned- 3.99%), ash (unpruned- 2.08%, 1m stem-pruned- 2.09%, and 2m stem-pruned- 2.15%) crude lipid(unpruned- 68.59%, 1m stem-pruned- 69.52%, and 2m stem-pruned- 72.53%), and crude protein (unpruned- 18.13%, 1m stem-pruned- 17.96%, and 2m stem-pruned- 17.56%) 2. Fatty acid analysis Seeds of tree from thinned and unthinned stands contained two essential fatty acids, i.e., linoleic acid (18:2) (thinned- 54.92%, unthinned- 55.40%) and linolenic acid (18:3) (thinned- 0.19%, and unthinned- 0.23%). Over 94% of fatty acids consisted of linoleic acid (18:2)(55%), oleic acid (18:1) (32%), and palmitic acid (16:0)(7%). T-test showed difference of content at 1% significance level for palmitoleic acid (16:1), stearic acid (18:0) and 8.11, 14-eicosatrienoic acid (20:3) and at 5% for linolenic acid (18:3), but no significant difference for three major fatty acids mentioned above, between two types of trees. Thus thinning may give no influence in fatty acid content. Seeds of three types of trees contained two essential fatty acids, i.e., linoleic acid (18:2)(unpruned- 55.25%, 1m stem-pruned- 54.74%, and 2m stem-pruned- 55.00%), and linolenic acid (18:3)(0.21% for three kinds of trees). Linoleic acid (18:2)(55%), oleic acid (18:1) (32%), and palmitic acid (16:0)(6%) consisted of more than 93% of all fatty acid content. At 5% significance level in F-test, difference was observed in the content of palmitoleic acid (16:1) and 8.11, 14-eicosatrienoic acid (20:3), but not in three major types of fatty acids above mentioned. It is observed that stem-pruning gave no significant influence in fatty acid content in general.

  • PDF