• Title/Summary/Keyword: crown preparation

Search Result 103, Processing Time 0.021 seconds

Survey on Waste Rates of Foods for Menu Planning (합리적인 식단작성을 위한 식품폐기율 조사 연구)

  • Mun, Hyeon-Gyeong;Gye, Seung-Hui;Kim, U-Seon;Lee, Ju-Hui;Kim, Suk-Ja
    • Journal of the Korean Dietetic Association
    • /
    • v.3 no.1
    • /
    • pp.55-62
    • /
    • 1997
  • The waste rates of 98 food items after pre-preparation were surveyed to provide database for good menu planning. The waste rates turned out 0-64.27% in vegetables, 6.38-7.03% in potatoes, 6.25-68.75% in fishes and shellfishes, 16.61% in eggs, and 16.00-56.84% in fruits. Foods with high waste rates were vegetables, fishes and shellfishes. Survey results were compared with other food composition tables. Foods with 30% higher waste rate than other food composition tables were squash leaf, pacific ocean perch, sweet potato stalk, water cress, green peas, alaska pollack, bluefin tuna, beka squid, crown daisy, dodok, amaranth, beef ribs. Food which waste rates turned out to be decreased by about 30% in this study were corb shell, pomfret, sea mussel, warty sea squirt. For the menu planning, reasonaly exact waste rates for each food items are essential. Since survey results show significant deviations, there should be more studies for exact waste rates for each food.

  • PDF

Extensive Bilateral Subcutaneous Emphysema after Dental Treatment: Two Case Reports

  • Gyu-Beom Kwon;Chul-Hwan Kim ;Hae-Seo Park
    • Journal of Korean Dental Science
    • /
    • v.16 no.1
    • /
    • pp.80-86
    • /
    • 2023
  • We report two rare cases of extensive bilateral subcutaneous emphysema that occurred during ordinary dental procedures. An air-driven high-speed handpiece, routinely used in dental procedures may cause subcutaneous emphysema when high pressure air is introduced into the loose connective tissues below the dermal layer. The first case occurred with surgical extraction of the lower third molar. The air introduced into the fascial spaces near the surgical field spread to the contralateral spaces, as well as the neck and chest areas. The second case also showed extensive bilateral subcutaneous emphysema caused by the introduction of compressed air from the handpiece during crown preparation without any invasive procedure. Cases where the emphysema extends beyond the treatment site to involve the contralateral cervicofacial areas have been rarely reported. Predicting the occurrence of subcutaneous emphysema is difficult, so it is important to exercise caution during routine dental treatment. If significant bilateral cervicofacial swelling is suspected to be due to subcutaneous emphysema, prompt diagnosis with securing the patient's airway will be necessary.

THE EFFECT OF THE ENDODONTIC ACCESS CAVITY ON THE MARGINAL LEAKAGE OF CROWNS (금전장관 수복물을 통한 치수강 개방이 금전장관 수복물의 미세변연누출에 미치는 영향)

  • Kim, Eui-Seong;Chung, Jin-Ho;Kim, Yong-Kun
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.389-393
    • /
    • 2002
  • The marginal integrity of the crown can be broken during endodontic access cavity preparation due to the vibration of burs. Therefore, the purpose of this study was to evaluate the effect of endodontic access cavity preparation on the marginal leakage of full veneer gold crowns. 24 intact molars were mounted in acrylic resin blocks and prepared for crowns by a restorative dentist and crowns were cast with gold alloy. 20 Crowns were cemented with glass ionomer cement and 2 crowns were not cemented for positive control. 200 thermo-cycles from 5$^{\circ}C$ to 5$0^{\circ}C$ with a travel time of 20s were completed. Then samples were randomly divided into 2 experimental groups of 9 each. Endodontic access preparation and zinc-oxide eugenol temporary fillings were done in Group 1. Teeth in Group 2 were not treated. Samples were coated with 2 layers of nail varnish and were immersed in 1% methylene blue dye for 20 hrs. Endodontic access was prepared in 2 samples, which were coated with nail varnish on all surfaces for negative control. After washing in running water gold crowns were cut with a #330 bur. Four buccolingual sections, 2 mm apart, were cut from the central section of each tooth and were examined and scored under the microscope for dye leakage. Score 1: leakage to the cervical 1/3 of the axial wall, Score 2: leakage to the middle 1/3 of the axial wall, Score 3: leakage to the coronal 1/3 of the axial wall, Score 4: leakage to the occlusal surface. The median value for Group 1 is 4 and for Group 2 is 2. The result of this study showed that samples in Group 1 leaked more than those in Group 2. This finding was significant(P<0.001).

CORONAL DYE PENETRATION OF THE APICAL FILLING MATERIALS AFTER POST SPACE PREPARATION (근광충전방법에 따른 post space형성후의 근관폐쇄성에 관한 실험적 연구)

  • Yoon, Soo-Han;Kweon, Oh-Yang
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.812-817
    • /
    • 1995
  • Endodontically treated teeth are usually restored for crown protection, aesthetics, and prevention of root canal recontamination. Restoration of these teeth, however, often requires intracanal posts. Various depths and techniques have been recommended for the preparation of post space. Therefore the purpose of this study was to evaluate the effect that pst preparation has on the coronal seal by linear dye penetration of root canals obturated by lateral condensation, vertical condensation, and thermafil techniques. Forty canals of roots of incisors and canines were cleaned and shaped with the use of a step-back technique. Thirty canals were obturated, 10 each with lateral, vertical, and thermafil techhniques. Five root canals were obturated without a root canal sealer and served as positive controls. Another five root canals were obturated, and their coronal half was sealed with sticky wax and served as negative controls. The apical 5 to 6mm of the filling materials were exposed to india ink for 48 hours. The depth of dye penetration was measured in all groups and statistically analyzed (ANOVA). The results were as follows. 1. The apical plugs in the thermafil groups had the highest degree of coronal dye leakage. 2. The group filled by vertical condensation technique had the lowest degree of coronal dye leakage. 3. No significant statistical difference was found in the amount of coronal dye leakage in canals filled by lateral condensation versus those filled by the veritcal condensation technique. 4. Significant statistical differences in coronal dye penetration were found between the canals filled by thermafil and those filled by the lateral or vertical condensation techniques (p<0.05).

  • PDF

Effect of post space preparation drills on the incidence of root dentin defects

  • Thaise Ayres Bezerra Zuli ;Orlando Aguirre Guedes ;Gislaine Figueiredo Zarza Arguello Goncalves;Aurelio Rosa da Silva Junior ;Alvaro Henrique Borges ;Andreza Maria Fabio Aranha
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.53.1-53.11
    • /
    • 2020
  • Objectives: This study investigated the incidence of root dentin defects after the use of different post space preparation (PSP) drills. Materials and Methods: Seventy-two bovine incisors were selected and obtained 14-mm-long root sections. Twelve roots served as controls with no intervention (G1). The 60 root canals remaining were instrumented using the crown-down technique with the ProTaper Next system and obturated using the lateral condensation technique. Specimens were randomly distributed into 5 groups (n = 12) according to the operative steps performed: G2, root canal instrumentation and filling (I+F); G3, I+F and PSP with Gates-Glidden drills; G4, I+FI+F and PSP with Largo-Peeso reamers; G5, I+F and PSP with Exacto drill; and G6, I+F and PSP with WhitePost drill. Roots were sectioned at 3, 6, 9, and 12 mm from the apex, and digital images were captured. The presence of root dentin defects was recorded. Data were analyzed by the χ2 test, with p < 0.05 considered to indicate statistical significance. Results: Root dentin defects were observed in 39.6% of the root sections. No defects were observed in G1. G5 had significantly more cracks and craze lines than G1, G2, and G3 (p < 0.05), and more fractures than G1, G2, G3, and G4 (p < 0.05). When all root sections were analyzed together, significantly more defects were observed at the 12-mm level than at the 3-mm level (p < 0.05). Conclusions: PSP drills caused defects in the root dentin. Gates-Glidden drills caused fewer root defects than Largo-Peeso reamers and Exacto drills.

COMPARISON OF CANAL SHAPING METHODS WITH GTTM ROTARY FILE AND CONDENSATION METHODS (GT rotary file을 이용한 근관성형법과 충전방법의 비교)

  • Kang, Yu-Mi;Jin, Jeong-Hee;Yu, Mi-Kyung;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.521-529
    • /
    • 2002
  • The purpose of this study was to compare the shaping time of two shaping methods and the leakage of three different obturation techniques. Ninty three canaled human molar teeth were used, which were randomly divided into two groups of forty teeth each and ten control teeth. After working length determination, the one group was prepared crown-down technique using rotary root canal instruments of GT rotary files .12/20, .10/20, .08/20 and .06/20 taper(Maillefer Instrument SA. Switzerland). The other group was instrumented with Gates Glidden burs(#1, #2, and #3) to coronal preparation and GT rotary files .08/20 and .06/30 taper to apical preparation. Shaping time was measured. After root canals were instrumented, they were divided to three subgroups and obturated as follows : Subgroup 1, obturated with single cone method Subgroup 2, obturated with lateral condensation : Subgroup 3, obturated with continuous wave technique. Three subgroups were obturated using non-standardized gutta-percha cone(Diadent, Korea, .06 or .08 taper) and AH-26(Dentsply DeTrey, Germany) as a root canal cement. Ten unobturated teeth served as positive and negative controls. After immersion in 2% methylene blue solution for 1 month, the teeth were washed during 24h. The teeth were demineralized in 10% nitric acid and dehydrated by immersion in 80, 90 and 100% ethyl alcohol. The teeth were finally cleared and stored in 100% methylsalicylate, and apical dye penetration was evaluated under stereomicroscope(Leica M420, LC, U.S.A)at $\times$8.75 magnification. Liner measurement of dye penetration was assessed with the use of digitalized image analysing system (analySIS, GmbH, Germany) The data were analysed statistically using independent T-test and Two-way ANOVA and Tukey test. The result were as follows 1. In canal prepared with GT$^{TM}$ rotary file, shaphing time taked more than the group of using Gates Glidden drill to coronal preparation without statistical significance (p>0.05) 2. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files showed significantly more apical leakage than those of lateral condensation and continuous wave technique regardless of shaping method (p<0.05). 3 The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed significantly more apical leakage than those of continuous wave technique regardless of shaping method (p<0.05). 4. Regardless of shaping method, The group of continuous wave obturation showed less apical leakage than those of lateral condensation without statistical significance (p>0.05). 5. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed more apical leakage than the group of lateral condensation using same shaping method with-out statistical significance (p>0.05).

PREPARATION OF CARBON DIOXIDE ABSORPTION MAP USING KOMPSAT-2 IMAGERY

  • Kim, So-Ra;Lee, Woo-Kyun
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.200-203
    • /
    • 2008
  • The objective of this study is to produce the $CO_2$ (carbon dioxide) absorption map using KOMPSAT-2 imagery. For estimating the amount of $CO_2$ absorption, the stand biomass of forest was estimated with the total weight, which was the sum of individual tree weight. Individual tree volumes could be estimated by the crown width extracted from KOMPSAT-2 imagery. In particular, the carbon conversion index and the ratio of the $CO_2$ molecular weight to the C atomic weight, reported in the IPCC (Intergovernmental Panel on Climate Change) guideline, was used to convert the stand biomass into the amount of $CO_2$ absorption. Thereafter, the KOMPSAT-2 imagery was classified with the SBC (segment based classification) method in order to quantify $CO_2$ absorption by tree species. As a result, the map of $CO_2$ absorption was produced and the amount of $CO_2$ absorption was estimated by tree species.

  • PDF

Time-dependent effects of EDTA for smear layer removal on microhardness of root canal dentine

  • Song, Yoon-Kyoung;Cho, Yong-Bum
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.587-589
    • /
    • 2003
  • I. Objectives The purpose of this study was to evaluate the effects of EDTA on microhardness of roor canal dentine according to different working time. II. Materials and Methods Forty recently extracted, intact single root teeth were used. Debris and soft tissue remnants on the root surface were cleaned with scaler and stored in saline at $4^{\circ}C$ until used. All selected roots were similar in size and shape. 1. Preparation of teeth. The crown of the teeth were removed at the level of the CEJ, using a water-cooled diamond bur.(omitted)

  • PDF

Superimposition: a simple method to minimize occlusal adjustment of monolithic restoration (디지털 장비의 중첩기능을 이용하여 단일체 수복물의 교합조정을 최소화한 증례)

  • Choi, Changhun;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.253-258
    • /
    • 2016
  • The development of translucent zirconia enabled clinicians to choose a monolithic zirconia crown as one treatment modality in the posterior dentition. Careful occlusal adjustments are recommended for monolithic zirconia crowns because grinding zirconia inevitably causes phase transformation, which may deteriorate mechanical properties. intraoral scanners enable the clinician to scan and superimpose a complete tooth structure before preparation onto the prepared abutment. This technique helps to reproduce the original tooth form and occlusion of the patient. In this case report, prostheses were fabricated for patients with cracked or fractured tooth by applying intraoral scanner, Computer aided design-computer aided manufacturing (CAD-CAM) and monolithic zirconia crown to reproduce the occlusion of original tooth and to minimize occlusal adjustment. The clinical results were satisfactory in both esthetic and functional aspects.

Characteristics and Preparation of Potassium Ion Selective Liquid Membrane Electrode Based on Polyurethane Matrix (폴리우레탄을 메트릭스로한 액막형 칼륨이온 선택성 전극의 제조 및 특성)

  • Kwang Sik Yoo;Yong Tack Lee;Chul Yong Kang
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.2
    • /
    • pp.128-134
    • /
    • 1991
  • Previous matrices of potassium ion selective electrodes are generally based on PVC. In this study, however, the electrode membrane was prepared with polyurethane matrix containing potassium tetraphenyl borate as sensing materials and D-18-Crown-6 and 2-nitrophenyl-n-alkylethers as solvent mediator. The average life time of the K$^+$-selective electrode based on polyurethane was 75 days which is significantly longer than PVC based one. The slope factor in linear dynamic range ($1{\times}10^{-1}\;{\sim}\;1{\times}10^{-4}$ M) was 52 mV/decade. The electrode has been successfully applied to find end point in potentiometric titration of K$^+$ with tetraphenyl borate solution in the sea water, even in the presence of several interfering cations$(NH^{4+},\;Na^{+},\;Li^{+},\;Ca^{2+},\;Mg^{2+},\;Cu^{2+}$).

  • PDF