• Title/Summary/Keyword: cross-view

Search Result 562, Processing Time 0.034 seconds

Metaphor: Interface between the Cognitive View and the Truth-conditional View

  • Yoon, Young-Eun
    • Language and Information
    • /
    • v.8 no.1
    • /
    • pp.163-182
    • /
    • 2004
  • Since metaphor was proposed to be a matter of thought instead of language over two decades ago, the research in this area has made most of its progress by the cognitivists. For the cognitivists represented by Lakoff, metaphor is not a mere poetic or rhetoric device, but is central to our everyday language. Furthermore, according to them, we categorize the world and break it into concepts mainly through metaphors, and truth conditions simply cannot account for metaphor. However, this cognitivists' view has been severely counterattacked by the truth-conditional semanticists. Their main criticism is that the cognitivists do not provide a way to go from our internal representations to the outside world. It is also criticized that the cognitive theory of metaphor as cross-conceptual domain mappings is too broad and general, and that they do not explain why a particular metaphorical expression should be subsumed under one mapping rather than another mapping, i.e., their schemes and structural relations are not predictive. In this context, the purpose of this paper is to propose a model for metaphor interpretation that combines the virtues of the two opposite views of metaphor. Truth-conditional semantics cannot ignore cognitive aspects of language, so-called states of affairs or mental representations, while cognitive theories cannot neglect vigorous representation of meaning with objective reality. This paper will try to present a preliminary outline of this combining model.

  • PDF

The Effect of the Axial Plane on Measurement of Available Bone Height for Dental Implant in Computed Tomography of the Mandible (하악의 전산화 단층사진에서 횡단면이 임플랜트를 위한 가용골 높이의 결정에 미치는 영향)

  • Jhin, Min-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.379-388
    • /
    • 2002
  • For the success of dental implant, accurate radiographic evaluation is prerequisite for planning the location of the osseointegrated implants and avoiding injury to vital structures. CT/MPR(computed tomography/multiplanar reformation) shows improved visualization of inferior alveolar canal. In order to obtain cross-sectional images parallel to the teeth, the occlusal plane is used to orientate for the axial plane. If the direction of axial plane is not parallel to the occlusal plane, the reformatted cross-sectional scans will be oblique to the planned fixture direction and will not show the actual dimension of the planned fixture's location. If the available bone height which measured in the cross-sectional view is much greater than the actual available bone height, penetration of canal may occur. The aim of this study is to assess the effect of the axial plane to measurement of available bone height for dental implant in computed tomography of the mandible. 40 patients who had made radiographic stents and had taken CT were selected. The sites that were included in the study were 45 molar regions. In the central panoramic scan, the length from alveolar crest to superior border of inferior alveolar canal(available bone height, ABH) was measured in direction of reformatted cross-sectional plane(uncorrected ABH). Then, length from alveolar crest to superior border of canal was measured in direction of stent(corrected ABH). The angle between uncorrected ABH and corrected ABH was measured. From each ABH, available fixture length was decided by $Br{{\aa}}nemark$ system. The results were following ; the difference between two ABHs was statistically significant in both first and second molar(p< 0.01). The percentage of difference more than 1 mm was 8.7% in first molar and 15.5% in second molar. The percentage of difference more than 2 mm was 2.0% in first molar and 6.6% in second molar. The maximum value of difference was 2.5 mm in first molar and 2.2 mm in second molar. The correlations between difference of 2 ABHs and angle was positive correlations in both first and second molar. The correlation coefficient was 0.534 in first molar and 0.728 in second molar. The second molar has a stronger positive correlation. The percentage of disagreement between 2 fixture lengths from two ABHs was 24.4% in first molar and 28.9% in second molar.

Effect of K2CO3 Retting on the Kenaf Fiber (K2CO3에 의한 케나프 섬유의 레팅 효과)

  • Song, Kyung-Hun;Lee, Hye-Ja;Han, Young-Sook;Yoo, Hye-Ja;Kim, Jung-Hee;Ahn, Choon-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.11
    • /
    • pp.1565-1573
    • /
    • 2007
  • This research was aimed to investigate the effect of $K_2CO_3$ instead of NaOH on retting of the kenaf bast. We examined the relationship between separation of fiber bundle and tensile strength besides observing the color, handle and cross sectional view for the kenaf fiber retted with various concentration(100, 150, 200, 250, 500, 1000mmol) of $K_2CO_3$ and double retted with 0.5% pectinase after $K_2CO_3$ retting. The one retted on low $K_2CO_3$ concentration, $150{\sim}200mmol$, showed the best result on color, handle and luster. The separation of fiber bundle started even at the low $K_2CO_3$ concentration, 100mmol, and as the $K_2CO_3$ concentration was higher, the size of the fiber bundle was smaller. In the case of 1000mmol, the fiber bundle became irregular, but they were breaking up into certain way. Regardless of $K_2CO_3$ concentration, the thinner the diameters of the kenaf fiber bundle, the stronger tensile strength have appeared. This result corresponds with the result of cross sectional view. Retting on $150{\sim}200mmol\;K_2CO_3$ concentration was most effective on fiber bundle#s separation and tensile strength. The one with double retted with 0.5% pectinase after $K_2CO_3$ retting showed very small size of fiber bundle and low tensile strength compare to the one just retted on $K_2CO_3$. This decrease of tensile strength seem to be related to damage of the fiber resulted by excessive fibrillation.

Serial Block-Face Imaging by Field Emission Scanning Electron Microscopy (전계방사형 주사전자현미경에 의한 연속블록면 이미징)

  • Kim, Ki-Woo
    • Applied Microscopy
    • /
    • v.41 no.3
    • /
    • pp.147-154
    • /
    • 2011
  • Backscattered electrons (BSE) are generated at the impact of the primary electron beam on the specimen. BSE imaging provides the compositional contrast to resolve chemical features of sectioned block-face. A focused ion beam (FIB) column can be combined with a field emission scanning electron microscope (FESEM) to ensure a dual (or cross)-beam system (FIB-FESEM). Due to the milling of the specimen material by 10 to 100 nm with the gallium ion beam, FIB-FESEM allows the serial block-face (SBF) imaging of plastic-embedded specimens with high z-axis resolution. After contrast inversion, BSE images are similar to transmitted electron images by transmission electron microscopy. As another means of SBF imaging, a specialized ultramirotome has been incorporated into the specimen chamber of FESEM ($3View^{(R)}$). Internal structures of plastic-embedded specimens can be serially revealed and analyzed by $3View^{(R)}$ with a large field of view to facilitate three-dimensional reconstruction. These two SBF approaches by FESEM can be employed to unravel spatial association of (sub)cellular entities for a comprehensive understanding of complex biological systems.

The Experimental Study of Myocardial Protection Byusing Cold Blood Potassium Cardioplegia in Open Heart Surgery (냉혈 Potassium 심정지액을 이용한 심근보호의 실험적 연구)

  • 이동준
    • Journal of Chest Surgery
    • /
    • v.13 no.3
    • /
    • pp.186-197
    • /
    • 1980
  • We attempted to evaluate the effectiveness of cold blood potassium cardioplegia [Group B] compared with that of intermittent aortic cross clamp with topical hypothermia [Group A] in each six dogs. The studies were performed under the extracorporeal circulation with moderate hypothermia by using Mongrel dogs. 1. In Group A [6], it was difficult to maintain the temperature below 20?. but in Group B [6], it was possible to maintain the temperature. 2. In blood pressure and myocardial recovery ability, Group B was more excellent than Group A. 3. There was no significant difference in Na+, Ca++ and Cl- between both groups, but in K+ level, Group A was mild decreased and Group B was nearly normal level. 4. In serum LDH level, Group A was higher than Group B, but in SGOT level there was no significance between both groups. 5. On electromicroscopical study, Group A showed severe change in mitochondria, but Group B was nearly normal view. Thus we suggest that cold blood potassium cardioplegia would be more effective than intermittent aortic cross clamp with topical hypothermia for myocardial protection in open heart surgery.

  • PDF

A cross - sectional analysis of scientific and technological performance for the railroad R&D (철도 R&D의 과학기술적 성과에 대한 횡단면 분석)

  • Park, Man-Soo;Bang, Yoon-Seok;Kwon, Yong-Jang;Moon, Dae-Seop;Lee, Hi-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1582-1590
    • /
    • 2011
  • An analysis of the railroad industry for R&D investments has been insufficient whereas there are lots of analysis of accumulation of technology, economic performances and ripple effects for macroscopic view and other industry of R&D investments. This study decided intellectual rights, patent, and paper as common indicators of scientific and technological performances for setting up performance targets through surveying and analysis of preceding study and verified a appropriateness of scientific and technological performances for railroad R&D 11 projects which were successfully finished. Preceding study has been set up performance targets by research investments as input, but this study made a performance target by model through a cross-sectional and residual analysis of performances of railroad R&D 11 Projects in applying research investments, capital investments, inner labor cost and inner labor cost per man and research time as inputs, and verified a validity and a empirical analysis through analysis of other project.

  • PDF

Effect of Biochar bead on Adsorption of Heavy Metals

  • Kim, Ho-Jin;Lee, Hochul;Kim, Hyuck-Soo;Kim, Kye-Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.5
    • /
    • pp.351-355
    • /
    • 2014
  • In recent years, biochar has received much attention as soil amendment, enhancing soil fertility and reducing toxicity of heavy metals with its large specific surface area and high pH. Biochar has also the effect of alleviating global warming by carbon sequestration from recycling organic wastes by pyrolysis. However, scattering of fine particles of biochar is a hindrance to expand its use from human health point-of-view. Alginate, a natural polymer without toxicity, has been used for capsulation and hydrogel fabrication due to its cross-linking nature with calcium ion. In this study, the method of cross-linkage between alginate and calcium ion was employed for making dust-free biochar bead. Then an equilibrium adsorption experiment was performed for verifying the adsorption effect of biochar bead on heavy metals (cadmium, copper, lead, arsenic, and zinc). Results showed that biochar bead had effects on adsorbing heavy metals, especially lead, except arsenic.

A Pilot Cross-Cultural Comparative Study on Users' Perception of the Webpage: With the Focus on Cognitive Style of Chinese and French

  • Dong, Ying;Lee, Kun-Pyo
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2007.05a
    • /
    • pp.157-160
    • /
    • 2007
  • Based on Nisbett and his colleagues' theoretical model "Holistic" and "Analytic" which show the differences in cognitive style of Eastern Asian and Westerners, the author hypothesized that the differences in cognitive style of people from diverse cultural backgrounds may influence their perception and usage of webpage. An experiment was carried out and the Eye-gaze device was used to assist to explore the relationship. The results revealed the relationship between cognitive style and webpage design. different cognitive style results different viewing pattern on webpage. Chinese people are more likely to have a holistic view of the whole page first and then focus on detail, while French people tend to read the heading information first and then proceeding down the page. Chinese emphasized the background as well as the whole look and feel of the webpage more, while French noticed the independent contents and element designs more on the webpage.

  • PDF

Cross-Sectional and Longitudinal Relationships Between Aggression, Prosocial Behavior and Peer Relations (아동의 외현적, 관계적 공격성 및 친사회성과 또래관계와의 횡·종단적 관계)

  • Sim, Hee-Og
    • Korean Journal of Child Studies
    • /
    • v.26 no.2
    • /
    • pp.121-134
    • /
    • 2005
  • Data were collected by peer nomination and sociometric nomination when children were in 4th grade and again two years later, Concurrent results of peer nominations were that prosocial children were more accepted while overtly/relationally aggressive children were more rejected by peers. Peer acceptance of males at Time 1 affected peer acceptance at Time 2. Peer rejection of females at Time 2 wasn't affected by overt aggression at Time 1. Cross-sectional results of social status were that rejected and controversial children showed higher levels of overt aggression than any other group. Popular children were most prosocial; rejected children were least prosocial. In the prospective view, aggressive males remained more rejected than any other group. Rejected children remained least prosocial.

  • PDF

Analysis of Density Distribution for Butane Using Three-dimentional and Real-time Digital Speckle Tomography (3차원 실시간 디지털 스페클 토모그래피를 이용한 부탄 밀도 분포 분석)

  • Go, Han-Seo;Park, Gwang-Hui;Kim, Yong-Jae
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1789-1794
    • /
    • 2003
  • Transient and asymmetric density distributions have been investigated by digital speckle tomography. Multiple CCD images captured movements of speckles in three angles of view simultaneously because the flows were asymmetric and transient. The speckle movements between no flow and downward butane flow from a circular half opening have been calculated by a cross-correlation tracking method so that those distances can be tranferred to deflection angles of laser rays for density gradients. The three-dimensional density fields have been reconstructed from the fringe shift by a real-time multiplicative algebraic reconstruction technique (MART).

  • PDF