Performance assessment of buckling restrained brace with tubular profile

  • Cao, Yan;Azar, Sadaf Mahmoudi;Shah, S.N.R.;Salih, Ahmed Fathi Mohamed;Thiagi, Tiana;Jermsittiparsert, Kittisak;Ho, Lanh Si
    • Advances in nano research
    • /
    • 제8권4호
    • /
    • pp.323-333
    • /
    • 2020
  • In recent years, there has been an upsurge for the usage of buckling restrained braces (BRB) rather than ordinary braces, as they have evidently performed better. If the overall brace buckling is ignored, BRBs are proven to have higher energy absorption capacity and flexibility. This article aims to deliberate an economically efficient yet adequate type of all-steel BRB, comprised of the main components as in traditional ones, such as : (1) a steel core that holds all axial forces and (2) a steel restrainer tube that hinders buckling to occurr in the core; there is a more practical detailing in the BRB system due to the elimination of a filling mortar. An investigation has been conducted for the proposed rectangular-tube core BRB and it is hysteric behavioral results have been compared to previous researches conducted on a structure containing a similar plate core profile that has the same cross-sectional area in its core. A loss of strength is known to occur in the BRB when the limiting condition of local buckling is not satisfied, thus causing instability. This typically occurs when the thickness of the restrainer tube's wall is smaller than the cross-sectional area of the core plate or its width. In this study, a parametric investigation for BRBs with different formations has been performed to verify the effect of the design parameters such as different core section profiles, restraining member width to thickness ratio and relative cross-sectional area of the core to restrainer, on buckling load evaluation. The proposed BRB investigation results have also been presented and compared to past BRB researches with a plate profile as the core section, and the advantages and disadvantages of this configuration have been discussed, and it is concluded that BRBs with tubular core section exhibit a better seismic performance than the ones with a plate core profile.

Effects of Traditional Korean Medicine Treatment On Lumbar Spinal Stenosis and Assessing Improvement by Radiological Criteria: An Observational Study

  • Kim, Hyun-Joong;Lee, Sun-Ho;Choi, Ji-Hoon;Noh, Je-Heon;Kim, Min-Young;Jang, Jae-Won;Ha, Do-Hyung
    • Journal of Acupuncture Research
    • /
    • 제34권4호
    • /
    • pp.172-179
    • /
    • 2017
  • Background: This study was designed to evaluate the clinical effectiveness of traditional Korean medicine treatment for lumbar spinal stenosis as assessed by radiological criteria. Methods: This was an observational study of 122 patients who were diagnosed with lumbar spinal stenosis and admitted to Jaseng Hospital between January 2016 and June 2017. They were analyzed according to sex, age, cause of disease, disease stage, length of admission, type of stenosis, morphological grade, and dural sac cross-sectional area. All patients were treated with traditional Korean medicine. Patients were assessed with the Numeric Rating Scale (NRS), Oswestry Disability Index (ODI) and EQ-5D before and after treatment. Results: Regarding the distribution of the factors analyzed, these were of note: more females than males (1:3.52); and highest proportions were age more than 70 years (37.70%), cause of lumbar spinal stenosis unknown (67.21%), and subacute stage (42.62%). Comparing before and after treatment, the NRS score for low back and pelvic pain decreased from $6.14{\pm}1.71$ to $4.28{\pm}1.91$ (p < 0.001), and the NRS score for radiating pain and numbness decreased from $6.27{\pm}1.61$ to $2.02{\pm}1.54$ (p < 0.001). ODI decreased from $46.86{\pm}19.40$ to $33.63{\pm}18.66$ (p < 0.001), and gait-related ODI decreased from $3.34{\pm}1.23$ to $2.80{\pm}1.11$ (p < 0.001). There were no statistically significant differences in improvement of the NRS, ODI, gait-related ODI, and EQ-5D for morphological grade and dural sac cross-sectional area. Conclusion: Traditional Korean medicine is effective treatment for patients with lumbar spinal stenosis. Even in patients with severe radiological findings, it is possible to reduce pain and improve quality of life.

Arching Effects on Stability of Translating Rigid Retaining Walls (아칭효과가 평행이동하는 강성옹벽의 안정성에 미치는 영향)

  • 백규호
    • Journal of the Korean Geotechnical Society
    • /
    • 제20권6호
    • /
    • pp.127-136
    • /
    • 2004
  • The soil arching in the backfill, which affects the magnitude and distribution of active earth pressure on a retaining wall, has also an effect on the stability and cross-sectional area of the retaining wall. In this study, results obtained from Paik's equation that includes arching effect on active earth pressure are compared with those from Coulomb theory to investigate the influence of the soil arching on active earth pressure, overturning moment, stability and cross-sectional area of translating rigid retaining walls. The comparisons show that the active forces including arching effects are always higher than those from Coulomb theory, irrespective of $\phi$ and $\delta$ values. The overturning moments, shear force and moment on the rigid wall are also higher when considering arching effects than when not considering arching effects. The deviation of shear forces and moments by including and excluding arching effects becomes maximum at the height of 0.02-0.08 times wall height from the base of the wall. Therefore, if a translating rigid retaining walls is designed based on Coulomb theory, the wall may reach sliding and overturning failures due to arching effect in the backfill and the cross-sectional area of the wall, especially at lower part of the wall, may not be sufficient to resist to shear force and moment.

An Experimental Study on the Improvement of Foam Fire-Extinguishing System's Mixing Ratios by Expanding the Cross Sectional Area of the Stock Solution Inhaling Piping (원액흡입배관 단면적 확장에 의한 포 소화설비 혼합비 개선에 관한 실험적 연구)

  • Yun, Ki-Jo;Jang, Kyung-Nam;Baek, Eun-Sun;Park, Bong-Rae;Park, Hee-Joog
    • Fire Science and Engineering
    • /
    • 제27권3호
    • /
    • pp.30-37
    • /
    • 2013
  • The ultimate purpose of the present study is to secure a effective method for foam liquid discharge when the mixing ratio deviates from the permissible range due to a decrease in the bypass flow rate resulting from a decrease in the cross sectional area of the foam liquid piping ranging from the branching header of one foam proportioner to the branching headers of multiple branching foam fire-extinguishing systems in the region for fire extinguishing and then to the standpipe at the lower part of the storage tank when a fire occurred in a combustible tank. To this end, the cause of mixing ratio variations following changes in the flow rates of existing foam fire extinguishing systems was analyzed, methods for compensation for constant mixing ratios were investigated, and it was proved that metering orifice replacements that could expand the cross sectional area of the stock solution inhaling piping was the most effective way for the improvement of form fire extinguishing systems' mixing ratios through foam proportioner venturi, foam chamber orifice, and metering orifice replacement experiments.

Treatment Outcomes of Septoplasty with Turbinate Surgery in Septal Deviation with Chronic Hypertrophic Rhinitis (비중격 만곡증 및 만성 비후성 비염 환자에서 비중격 성형술고 하비갑개 수술의 치료효과)

  • Kim, Yong-Dae;Suh, Bo-Su;Cho, Gil-Sung;Song, Si-Youn;Yoon, Seok-Keun;Song, Kei-Won
    • Journal of Yeungnam Medical Science
    • /
    • 제18권2호
    • /
    • pp.199-207
    • /
    • 2001
  • Background: Septoplasty with turbinate surgery is common surgical treatment in patients with septal deviation and chronic hypertrophic rhinitis. The aim of this study was to evaluation objective outcomes of septoplasty with turbinate surgery by analysis of subjective symptom score with objective acoustic rhinometric test before and after surgery, prospectively. Materials and Methods: We reviewed 45 adult patients which were done septoplasty with bilateral turbinectomy or turbinoplasty and followed up at least 3 months by one rhinologist from November 1999 to April 2000, prospectively. We analyzed subjective symptom score, minimal cross-sectional area (MCA), C-notch cross-sectional area, and total volume of both nasal cavity before and after surgery. Correlation test was studied between symptom improvement and acoustic rhinometric results. Results: Twenty nine cases were male and sixteen cases female. The average age was 26.9 year-old (range: 17 to 57 years). There was significantly improvement of symptom score in postoperative 3 months (p<0.05). There was significantly increased C-notch cross-sectional area and total volume in postoperative 3 months. Symptoms improvement were associated with acoustic rhinometric profiles, but, there was not significantly correlation. Conclusion: Septoplasty with turbinate surgery is considered to be effective for nasal obstruction in patients with septal deviation and turbinate hypertrophy. Acoustic rhinometric test is favorable objective test for evaluation of symptom improvement after septal surgery.

  • PDF

A Study for Comparison of Geometric Characteristics on Forearms for Improvement of Convinience in Splint Manufacturing with 3D Printing Technology (3D 프린팅 기술을 적용한 스플린트의 제작 용이성 향상을 위한 아래팔 기하 정보 비교에 관한 연구)

  • Chang, Ji Hong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • 제12권5호
    • /
    • pp.475-481
    • /
    • 2019
  • A splint is one of assisting devices for the disabled with hemiplegia or contracture and is manually made by an experienced expert. Heated thermoplastic materials are continuously fitted to the affected part. This traditional method has a possible risk of low-temperature burn, quality variance of the splint due to the proficiency of maker. etc. While various approaches has been made using 3D printing technology in order to redeem those disadvantages, they still carry high cost issues with 3D scanners or accuracy issues with manual measurement. This research begins with symmetrical characteristics of human body and focuses on the preliminary study for the possibility of splint manufacturing with 3D printing technology based on geometric characteristics of unaffected arm. 3D right and left forearm models of healthy male adults were created by photogrammetry software and a series of digital images in order to measure the circumference and cross-sectional area of the forearm models at every 20mm from the elbow. The circumference and cross-sectional area showed tolerable levels of differences between both sides within subjects; The circumference and cross-sectional area showed very strong correlations between both sides within subjects. From these findings, the possibility of splint manufacturing with 3D printing technology could be confirmed based on the geometric characteristics of unaffected side.

Analysis of the Correlation Between Kidney Function Indicators and Kidney Size According Age Groups in Ultrasonography (신장 초음파 검사에서 연령대에 따른 신장 기능 지표와 신장 크기 간의 상관관계 분석)

  • Go, Ryo-won;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • 제14권7호
    • /
    • pp.871-879
    • /
    • 2020
  • The purpose of this study was to analysis the correlation between kidneys function indicators and these size in ultrasonography. A total of 170 (male:86, female:84) patients of sex and age groups were examined by abdominal ultrasonography. The patients classified as those in their 20's, 30's, 40's, and over 50's. We measured the length, width, and cross-sectional height of the kidneys twice. At this time, the length of these were measured from the maximum upper to the maximum lower pole and the widest width in the same ultrasonography was measured to obtain the cross-sectional area. Other relevant indicators included body surface area, serum creatinine, glomerular filtration rate (GFR), MDRD (Modification of diet in renal disease) and C-G (Cockcroft-Gault). Significant comparisons of differences between relevant factors by age groups and sex were conducted with a one-way distribution analysis. Correlation analysis was also performed between relevant factors by using Pearson and Spearman correlation coefficient. It was defined as meaningful when the p-value was less than 0.05. As a result, the length, the width, and the cross-sectional area of kidneys were correlated with GFR, C-G, MDRD. Therefore, it is expected that the accuracy of diagnosis of kidneys disease will be increased if the relevant indicators are evaluated together rather than measuring only length of these in ultrasonography.

Determination of the initial cross-sections for the $C_4F_6$ molecule from the electron drift velocity ($C_4F_6$-Ar혼합기체에서의 Plasma Discharge Simulation을 위한 $C_4F_6$ 초기단면적 결정)

  • Lee, Kyung-Yeob;Jeon, Byung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1544-1545
    • /
    • 2011
  • For quantitative understanding of gas discharge phenomena, we should know electron collision cross section. Processing plasma etching of semiconductor, and research are being used in the etching source $C_4F_6$ gas may be used by itself and mixed with other gases are also used. However, the molecular gas $C_4F_6$ study on the characteristics of the electron transport and the cross-sectional area of the decision is still lacking. Therefore, we understand the electron transport characteristics and analysed the electron transport coefficients. And to understand and interpret physical properties of the ionization coefficient ${\alpha}$/N, and the attachment coefficient ${\eta}$/N in $C_4F_6$ gas.

  • PDF

Position of the hyoid bone and its correlation with airway dimensions in different classes of skeletal malocclusion using cone-beam computed tomography

  • Shokri, Abbas;Mollabashi, Vahid;Zahedi, Foozie;Tapak, Leili
    • Imaging Science in Dentistry
    • /
    • 제50권2호
    • /
    • pp.105-115
    • /
    • 2020
  • Purpose: This study investigated the position of the hyoid bone and its relationship with airway dimensions in different skeletal malocclusion classes using cone-beam computed tomography (CBCT). Materials and Methods: CBCT scans of 180 participants were categorized based on the A point-nasion-B point angle into class I, class II, and class III malocclusions. Eight linear and 2 angular hyoid parameters(H-C3, H-EB, H-PNS, H-Me, H-X, H-Y, H-[C3-Me], C3-Me, H-S-Ba, and H-N-S) were measured. A 3-dimensional airway model was designed to measure the minimum cross-sectional area, volume, and total and upper airway length. The mean crosssectional area, morphology, and location of the airway were also evaluated. Data were analyzed using analysis of variance and the Pearson correlation test, with P values <0.05 indicating statistical significance. Results: The mean airway volume differed significantly among the malocclusion classes(P<0.05). The smallest and largest volumes were noted in class II (2107.8±844.7 ㎣) and class III (2826.6±2505.3 ㎣), respectively. The means of most hyoid parameters (C3-Me, C3-H, H-Eb, H-Me, H-S-Ba, H-N-S, and H-PNS) differed significantly among the malocclusion classes. In all classes, H-Eb was correlated with the minimum cross-sectional area and airway morphology, and H-PNS was correlated with total airway length. A significant correlation was also noted between H-Y and total airway length in class II and III malocclusions and between H-Y and upper airway length in class I malocclusions. Conclusion: The position of the hyoid bone was associated with airway dimensions and should be considered during orthognathic surgery due to the risk of airway obstruction.

Evaluation of normal masseter muscles on ultrasonography (초음파영상을 이용한 정상 교근의 평가)

  • Hwang, Hyoung-Zoo;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • 제38권2호
    • /
    • pp.73-79
    • /
    • 2008
  • Purpose: To assess the internal echo intensity and morphological variability of masseter muscles on ultrasonography and to establish diagnostic criterion of estimation. Materials and Methods: Participants consisted of 50 young adults (male 25, female 25) without pathologic conditions and with full natural dentitions. Sonographic examinations were done with real time ultrasound equipment as Logiq 500 (GE Medical Systems, Seoul, Korea) at 3 parts according to lines paralleling with ala-tragus line as reference line. The thickness and area of masseter muscles according to reference line in cross-sectional images were measured at rest and at maximum contraction. The visibility and width of the internal echogenic intensity of the masseter muscles were also assessed and the muscle appearance was classified into 4 types. Data were statistically analyzed by paired t-test and $x^2$-test. Results: 1. When comparing the thickness and area of masseter muscles concerning with gender, there was few significant difference between right and left sides, however, there were significant differences between males and females except for the greatest thickness of left side. 2. The changes of the greatest thickness and the area between rest and maximum contraction showed that the part of the least thickness manifested more increase at maximum contraction. 3. Each part the manifestations of the internal echogenic intensity of the masseter muscles were different depending on the locations. But there was no statistically significance. Conclusion: Changes of muscles thickness with contraction and internal echogenic intensity with locations showed great disparity within the masseter muscles, which will be diagnostic criteria for pathophysiologic and anatomic changes of masseter muscles.

  • PDF