• 제목/요약/키워드: cross flow

검색결과 2,036건 처리시간 0.03초

The Feasibility of Event-Related Functional Magnetic Resonance Imaging of Power Hand Grip Task for Studying the Motor System in Normal Volunteers; Comparison with Finger Tapping Task

  • Song, In-Chan;Chang, Kee-Hyun;Han, Moon-Hee
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.111-111
    • /
    • 2001
  • 목적: To evaluate the feasibility of the event-related functional MR study using power grip studying the hand motor system 대상 및 방법: Event-related functional MRI was performed on a 1.5T MR unit in seven norm volunteers (man=7, right-handedness=2, left-handedness=5, mean age: 25 years). A single-shot GRE-EPI sequence (TR/TE/flip angle: 1000ms/40ms/90, FOV = 240 mm matrix= 64$\times$64, slice thickness/gap = 5mm/0mm, 7 true axial slices) was used for functiona MR images. A flow-sensitive conventional gradient echo sequence (TR/TE/flip angl 50ms/4ms/60) was used for high-resolution anatomical images. To minimize the gross hea motion, neck-holders (MJ-200, USA) were used. A series of MR images were obtained in axial planes covering motor areas. To exclude motion-corrupted images, all MR images wer surveyed in a movie procedure and evaluated using the estimation of center of mass of ima signal intensities. Power grip task consisted of the powerful grip of all right fingers and hand movement ta used very fast right finger tapping at a speed of 3 per 1 second. All tasks were visual-guid by LCD projector (SHARP, Japan). Two tasks consisted of 134 phases including 7 activatio and 8 rest periods. Active stimulations were performed during 2 seconds and rest period were 15 seconds and total scan time per one task was 2 min 14 sec. Statistical maps we obtained using cross-correlation method. Reference vector was time-shifted by 4 seconds an Gaussian convolution with a FWHM of 4 seconds was applied to it. The threshold in p val for the activation sites was set to be 0.001. All mapping procedures were peformed usin homemade program an IDL (Research Systems Inc., USA) platform. We evaluated the activation patterns of the motor system of power grip compared to hand movement in t event-related functional MRI.

  • PDF

Dynamic Stereo PIV에 의한 델타형 날개에서의 3차원 와류 유동에 관한 연구 (Three Dimensional Vortex Behavior of LEX Delta Wing by Dynamic Stereo PIV)

  • 이현;김미영;최장운;최민선;이영호
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2003년도 추계학술대회 논문집
    • /
    • pp.39-42
    • /
    • 2003
  • Leading edge extension(LEX) in a highly swept shape applied to a delta wing features the modern air-fighters. The LEX vortices generated upon the upper surface of the wing at high angle of attack enhance the lift force of the delta wing by way of increased negative suction pressure over the surfaces. The present 3-D stereo PIV includes the Identification of 2-D cross-correlation equation, stereo matching of 2-D velocity vectors of two cameras, accurate calculation of 3-D velocity vectors by homogeneous coordinate system, removal of error vectors by a statistical method followed by a continuity equation criterion and so on. A delta wing model with or without LEX was immersed in a circulating water channel. Two high-resolution, high-speed digital cameras$(1280pixel\times1024pixel)$ were used to allow the time-resolved animation work. The present dynamic stereo PIV represents the complicated vortex behavior, especially, in terms of time-dependent characteristics of the vortices at given measuring sections. Quantities such as three velocity vector components, vorticity and other flow information can be easily visualized via the 3D time-resolved post-processing to make the easy understanding of the LEX effect or vortex emerging and collapse which are important phenomena occurring in the field of delta wing aerodynamics.

  • PDF

전산유체역학을 이용한 직교류 미세관 관군의 전열 성능 해석 (Analysis of Heat Transfer Performance for Mini-Channel Tube Bundles in Cross flow using CFD)

  • 남기원;민준기;정지환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권4호
    • /
    • pp.491-499
    • /
    • 2010
  • 관군은 열전달기기에서 광범위하게 사용되고 있어서 전열성능 및 압력강하 특성은 오래전부터 다양한 연구가 진행되어왔다. 기존의 관군에 관한 실험 및 해석은 대부분 25~51mm 직경의 전열관을 이용하여 Reynolds 수 $8.000{\leq}Re{\leq}30.000$ 범위에서 수행되었으나 최근에는 직경 1mm 안팎의 미세관으로 관군을 만들어 열교환기의 밀집도를 높이려는 데 관심이 많다. 본 논문에서는 이전에 다루지 않았던 관 외경 1.5mm의 관군의 전열성능을 $3.000{\leq}Re{\leq}7.000$ 범위에서 전산유체역학을 이용하여 평가하고 기존의 연구 결과들과 비교하였다. 그 결과 튜브직경이 1.5mm인 관군의 열전달계수와 압력손실계수는 $3.000{\leq}Re{\leq}7.000$ 범위에서도 기존의 Zukauskas 상관식과 최대 4.7% 차이 이내로 일치하였다. 또한 튜브의 횡방향 간격을 줄여서 각 열의 전열성능을 높일 수 있음을 확인하였다.

The turbulent wake of a square prism with wavy faces

  • Lin, Y.F.;Bai, H.L.;Alam, Md. Mahbub
    • Wind and Structures
    • /
    • 제23권2호
    • /
    • pp.127-142
    • /
    • 2016
  • Aerodynamic effects, such as drag force and flow-induced vibration (FIV), on civil engineering structures can be minimized by optimally modifying the structure shape. This work investigates the turbulent wake of a square prism with its faces modified into a sinusoidal wave along the spanwise direction using three-dimensional large eddy simulation (LES) and particle image velocimetry (PIV) techniques at Reynolds number $Re_{Dm}$ = 16,500-22,000, based on the nominal width ($D_m$) of the prism and free-stream velocity ($U_{\infty}$). Two arrangements are considered: (i) the top and bottom faces of the prism are shaped into the sinusoidal waves (termed as WSP-A), and (ii) the front and rear faces are modified into the sinusoidal waves (WSP-B). The sinusoidal waves have a wavelength of $6D_m$ and an amplitude of $0.15D_m$. It has been found that the wavy faces lead to more three-dimensional free shear layers in the near wake than the flat faces (smooth square prism). As a result, the roll-up of shear layers is postponed. Furthermore, the near-wake vortical structures exhibit dominant periodic variations along the spanwise direction; the minimum (i.e., saddle) and maximum (i.e., node) cross-sections of the modified prisms have narrow and wide wakes, respectively. The wake recirculation bubble of the modified prism is wider and longer, compared with its smooth counterpart, thus resulting in a significant drag reduction and fluctuating lift suppression (up to 8.7% and 78.2%, respectively, for the case of WSP-A). Multiple dominant frequencies of vortex shedding, which are distinct from that of the smooth prism, are detected in the near wake of the wavy prisms. The present study may shed light on the understanding of the underlying physical mechanisms of FIV control, in terms of passive modification of the bluff-body shape.

혈장내 염의 Poly(2-Hydroxyethyl Methacrylate) 격막 투과현상 (Transport of Some Solutes in Blood Plasma Through Poly(2-Hydroxyethyl Methacrylate) Hydrogel Membrane)

  • 지종기;전무식;이태규
    • 대한화학회지
    • /
    • 제22권5호
    • /
    • pp.304-310
    • /
    • 1978
  • 혈장내의 중요한 성분인 몇가지 염들이 poly(2-hydroxyethyl methacrylate) 격막을 통과하는 상대투과계수($U_{re}$), 분배계수($K_D$), 확산계수($D_m$)등을 측정하였다. 이 격막을 제조할 때 cross-linker로서 사용된 tetraethylene glycol dimethacrylate(TEGDMA)의 함량은 중량비로 2.8%였다. 이 염들의 확산계수는 그 분자량이 증가함에 따라서 지수함수적으로 감소하였으며, 그 분자의 원통반지름(a)에 대해서는 요소를 제외하고는 직선적으로 감소하였다. 이와 같은 사실을 sieve pore filow 모델로서 설명하였다. 여러 온도에서 요소의 $U_{re}$$D_m$은 글리신, ${\beta}$-알라닌, D-글루코오스, 사카로스 및 말레산과 같은 다른 염들의 값보다 더 컸다. 이와 같은 결과는 이 poly(HEMA) 격막이 혈투석 응용에 적합하다는 사실을 보여 주었다.

  • PDF

지지격자를 갖는 $5\times{5}$ PWR 봉다발에서의 난류유동 측정 (Measurements of Turbulent How in $5\times{5}$ PWR Rod Bundles With Spacer Grids)

  • Yang, Sun-Kyu;Chung, Heung-June;Chun, Se-Young;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • 제24권3호
    • /
    • pp.263-273
    • /
    • 1992
  • 핵연료 집합체의 속도분포, 압력강하는 열수력 설계와 안전해석에 중요하다. 본 실험적 연구의 목적은 봉다발 지지 격자 하류에서의 수력학적 혼합을 고찰하는데 있다. 이 연구에서 가압경수로형 5X5 봉다발 부수로의 상세한 수력학적 특성들을 1차익 He-Ne LDV를 이용하여 측정하였다. 축방향 유속, 난류강도와 압력강하를 주로 측정하였고 LDV의 정렬을 조정하여 측방향의 유속, 난류강도, Reynolds 전단응력 등도 역시 측정하였다. 봉다발의 마찰계수와 지지 격자의 손실계수는 측정된 압력 강하로부터 평가하였다. 서로 다른 종류의 지지 격자의 수력학적 혼합성능을 이웃하는 부수로 간에서의 난류 횡류 혼합률을 예측함으로써 고찰할 수 있었다.

  • PDF

범프로 지지되는 다엽 포일을 갖는 가스 포일 베어링의 성능 해석 (Performance Predictions of Gas Foil Bearing with Leaf Foils Supported on Bumps)

  • 김태호;문형욱
    • Tribology and Lubricants
    • /
    • 제34권3호
    • /
    • pp.75-83
    • /
    • 2018
  • Microturbomachinery (< 250 kW) using gas foil bearings can function without oil lubricants, simplify rotor-bearing systems, and demonstrate excellent rotordynamic stability at high speeds. State-of-the-art technologies generally use bump foil bearings or leaf foil bearings due to the specific advantages of each of the two types. Although these two types of bearings have been studied extensively, there are very few studies on leaf-bump foil bearings, which are a combination of the two aforementioned bearings. In this work, we illustrate a simple mathematical model of the leaf-bump foil bearing with leaf foils supported on bumps, and predict its static and dynamic performances. The analysis uses the simple elastic model for bumps that was previously developed and verified using experimental data, adds a leaf foil model, and solves the Reynolds equation for isothermal, isoviscous, and ideal gas fluid flow. The model predicts that the drag torques of the leaf-bump foil bearings are not affected significantly by static load and bearing clearance. Due to the preload effect of the leaf foils, rotor spinning, even under null static load, generates significant hydrodynamic pressure with its peak near the trailing edge of each leaf foil. A parametric study reveals that, while the journal eccentricity and minimum film thickness decrease, the drag torque, direct stiffness, and direct damping increase with increasing bump stiffness. The journal attitude angle and cross-coupled stiffness remain nearly constant with increasing bump stiffness. Interestingly, they are significantly smaller compared to the corresponding values obtained for bump foil bearings, thus, implying favorable rotor stability performance.

공동조리 학교급식의 미생물적 품질보증을 위한 위험요인 분석 (Hazard Analysis of Commissary School Foodservice Operations)

  • 곽동경;남순란;김정리;박신정;서소영;김성희;최은희
    • 한국식품조리과학회지
    • /
    • 제11권3호
    • /
    • pp.249-260
    • /
    • 1995
  • 6 Central commissary and 2 conventional school foodservice operations were assessed in terms of time-temperature relationship and microbiological quality, and monitoring control methods were identified through hazard analysis during the phases of prodution and distribution. 2 conventional schools from Seoul and 6 commissary schools from Kyungkido were participated in the survey. Meals produced in central commissary were distributed to satellites, therefore delivery practices of foods were identified as critical. Microbiological test results for commissary and conventional schools revealed that microbiological quality of foods was mainly related to time-temperature management, types of food, and equipment sanitation not to the foodservice system used. Time-temperature profiles at temperature danger zone (7.2-60$^{\circ}C$) observed were to be related to the following sanitary practices: cooked vegetables were held at temperature danger zone for relatively longer delayed time (15-38$^{\circ}C$: 15-226 min, 7-60$^{\circ}C$: 75-226 min), and same results were observed for deep-fat fried cutlets (15-38$^{\circ}C$: 15-151 min, 7-60$^{\circ}C$: 33-151 min). Menu items with various ingredients and frequent contacts with hands and equipments during the production flow were held at temperature danger zone for longer delaying time than other menu items with brief prodution stages. Based on hazard analysis critical control points, microbiological quality was collectively affected by time-temperature relationships, equipment sanitation, proper cooking methods, and sanitary management competencies of dietitians. Microbiological test results of working equipments and surface of dishes and trays showed that immediate action should be taken. Cutting boards used in central kitchen were also showed similar results of potential dager of cross-contamination. Effective sanitary control methods were urgently needed.

  • PDF

Thermal Transient Characteristics of Die Attach in High Power LED Package

  • Kim Hyun-Ho;Choi Sang-Hyun;Shin Sang-Hyun;Lee Young-Gi;Choi Seok-Moon;Oh Yong-Soo
    • 마이크로전자및패키징학회지
    • /
    • 제12권4호통권37호
    • /
    • pp.331-338
    • /
    • 2005
  • The rapid advances in high power light sources and arrays as encountered in incandescent lamps have induced dramatic increases in die heat flux and power consumption at all levels of high power LED packaging. The lifetime of such devices and device arrays is determined by their temperature and thermal transients controlled by the powering and cooling, because they are usually operated under rough environmental conditions. The reliability of packaged electronics strongly depends on the die attach quality, because any void or a small delamination may cause instant temperature increase in the die, leading sooner or later to failure in the operation. Die attach materials have a key role in the thermal management of high power LED packages by providing the low thermal resistance between the heat generating LED chips and the heat dissipating heat slug. In this paper, thermal transient characteristics of die attach in high power LED package have been studied based on the thermal transient analysis using the evaluation of the structure function of the heat flow path. With high power LED packages fabricated by die attach materials such as Ag paste, solder paste and Au/Sn eutectic bonding, we have demonstrated characteristics such as cross-section analysis, shear test and visual inspection after shear test of die attach and how to detect die attach failures and to measure thermal resistance values of die attach in high power LED package. From the structure function oi the thermal transient characteristics, we could know the result that die attach quality of Au/Sn eutectic bonding presented the thermal resistance of about 3.5K/W. It was much better than those of Ag paste and solder paste presented the thermal resistance of about 11.5${\~}$14.2K/W and 4.4${\~}$4.6K/W, respectively.

  • PDF

NACA 662-415 단면을 가지는 타원형 수중익의 날개 끝 보오텍스 및 캐비테이션 수치해석 (Numerical Analysis of Tip Vortex and Cavitation of Elliptic Hydrofoil with NACA 662-415 Cross Section)

  • 박일룡;김제인;설한신;김기섭;안종우
    • 한국해양공학회지
    • /
    • 제32권4호
    • /
    • pp.244-252
    • /
    • 2018
  • This paper provides quantification of the effects of the turbulence model and grid refinement on the analysis of tip vortex flows by using the RANS(Reynolds averaged Navier-Stokes) method. Numerical simulations of the tip vortex flows of the NACA $66_2$-415 elliptic hydrofoil were conducted, and two turbulence models for RANS closure were tested, i.e., the Realizable $k-{\varepsilon}$ model and the Reynolds stress transport model. Numerical results were compared with available experimental data, and it was shown that the data for the Reynolds stress transport model that were computed on the finest grid system had better agreement in reproducing the development and propagation of the tip vortex. The Realizable $k-{\varepsilon}$ model overestimated the turbulence level in the vortex core and showed a diffusive behavior of the tip vortex. The tip vortex cavitation on the hydrofoil and its trajectory also showed good agreement between the current numerical results that were obtained using the Reynolds stress transport model and the results observed in the experiment.