• Title/Summary/Keyword: critical loads

Search Result 729, Processing Time 0.029 seconds

An Analysis of Dynamic Critical Loads for Low Parabolic Arches with Different End Conditions (지지조건을 고려한 낮은 포물선 아치의 동적 임계하중의 해석)

  • 박승범
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.28 no.2
    • /
    • pp.87-92
    • /
    • 1986
  • The differential equation, which can determine the dynamic critical loads for low parabcoic arches, is derived in this study. The dynamic critical loads of the parabolic arches subjected to a concentrated step load are nummerically analyzed for the changes of load positions. In cases of arches with different end conditions (both hinged, fixed hinged, both fixed), the effect of end conditions and that of the rises are investigated in detail. The summary of the results are the following: 1)The snapthrough does not occur when the rise of arch is very low, and the bifurcation appears clearly as the rise of arch increases. 2)The regions in which the dynamic critical loads are not defined for the both ends fixed are broader than that for the both ends hinged. 3)For all case, the load positions of minimum dynamic critical loads exsit at the near position from the end hinged. Thus, the results obtained in present study show that the magnitude of dynamic critical loads, the load positions of minimum dynamic critical loads and the regions in which the dynamic critical loads are not defined depend on end conditions of arches.

  • PDF

The Elastic Critical Loads of Sinusolidally Tapered Symmetric Compression Members (정현상 대칭으로 Taper진 변단면 압축재의 임계하중)

  • 오금열;홍종국;김순철;이수곤
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.04b
    • /
    • pp.27-34
    • /
    • 2000
  • The elastic critical loads of prismatic compression members can be easily determined by the conventional analytic method. In the cases of sinusoidally tapered members, however, the determination of elastic critical loads become impossible when one relies on the analytic method. In this paper, the critical loads of sinusoidally tapered members were determined by finite element method. Generally the output or results of numerical analysis are valid only when the governing parameters of a given system(or problem) have particular values. To make the practical applications easy, the critical loads determined by finite element method are expressed by some algebraic equations. The constants contained in the algebraic equations were determined by regression technique. The elastic critical loads estimated by the proposed algebraic equations coincide well with those by finite element method.

  • PDF

Features of Critical Tensile Stresses in Jointed Concrete Pavements under Environmental and Vehicle Loads (환경하중과 차량하중에 의한 줄눈콘크리트포장의 극한인장응력 특성 분석)

  • Kim, Seong-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.449-456
    • /
    • 2007
  • This research was conducted to analyze the features of the critical tensile stresses at the top and bottom of the concrete slab in the jointed concrete pavement (JCP) when subjected to both the environmental and vehicle loads. First, the stress distribution in JCP was analyzed when the system was subjected to only the environmental loads or the vehicle loads by using the finite element model of JCP. Then, the stresses were analyzed when the system was subjected to the environmental and vehicle loads at the same time. From this study, it was found that the critical tensile stresses at the slab bottom under the vehicle loads were almost constant regardless of the loading positions once the loads were applied at the positions having some distance from the transverse joint. The critical tensile stresses at the slab bottom could be obtained using the model consisting of normal springs for underlying layers by adding the critical stresses due to the environmental loads and the vehicle loads for the curled-down slab, and by subtracting the critical stress due to the environmental loads from that due to the vehicle loads for the curled-up slab. The critical tensile stresses at the top of the slab could be obtained using the model consisting of tensionless springs for underlying layers by adding the critical stress due to the environmental loads and the stress at the middle of the slab under the vehicle loads applied at the joint for the curled-up slab. An alternative to obtain the critical stresses at the top of the slab for the curled-up slab was to use the critical stresses under only the environmental loads obtained from the model having normal springs for underlying layers.

Load-carrying capacities and failure modes of scaffold-shoring systems, Part II: An analytical model and its closed-form solution

  • Huang, Y.L.;Kao, Y.G.;Rosowsky, D.V.
    • Structural Engineering and Mechanics
    • /
    • v.10 no.1
    • /
    • pp.67-79
    • /
    • 2000
  • Critical loads and load-carrying capacities for steel scaffolds used as shoring systems were compared using computational and experimental methods in Part I of this paper. In that paper, a simple 2-D model was established for use in evaluating the structural behavior of scaffold-shoring systems. This 2-D model was derived using an incremental finite element analysis (FEA) of a typical complete scaffold-shoring system. Although the simplified model is only two-dimensional, it predicts the critical loads and failure modes of the complete system. The objective of this paper is to present a closed-form solution to the 2-D model. To simplify the analysis, a simpler model was first established to replace the 2-D model. Then, a closed-form solution for the critical loads and failure modes based on this simplified model were derived using a bifurcation (eigenvalue) approach to the elastic-buckling problem. In this closed-form equation, the critical loads are shown to be function of the number of stories, material properties, and section properties of the scaffolds. The critical loads and failure modes obtained from the analytical (closed-form) solution were compared with the results from the 2-D model. The comparisons show that the critical loads from the analytical solution (simplified model) closely match the results from the more complex model, and that the predicted failure modes are nearly identical.

Design load-carrying capacity estimates and an improved wooden shore setup

  • Huang, Y.L.;Lin, Y.C.;Lee, C.F.;Chen, H.J.;Yen, T.
    • Structural Engineering and Mechanics
    • /
    • v.17 no.2
    • /
    • pp.167-186
    • /
    • 2004
  • The design load-carrying capacities of wooden shores depend on factors, such as the wood species and properties, and construction methods. This paper focuses on the construction methods, including an upright single shore, group of upright shores, group of inclined shores, butt connections and lap connections. This paper reports experiments to obtain critical loads and then developed an empirical equation based on Euler' formula for the critical loads and design load-carrying capacities. The test results show that the critical loads for an upright single wooden shore are greater than the average values for a group of upright shores, and the latter are greater than the average values for a group of inclined shores. Test results also show that the critical loads become smaller when butt or lap connections are used, butt connections possessing greater critical loads than lap connections. Groups of inclined shores are very popular at work sites because they have some practical advantages even though they actually possess inferior critical loads. This paper presents an improved setup for constructing groups of inclined shores. With this method, the inclined shores have larger critical loads than upright shores. The design load-carrying capacities were obtained by multiplying the average critical loads by a resistance factor (or strength reduction factor, ${\phi}$) that were all smaller than 1. This article preliminarily suggests ${\phi}$ factors based on the test results for the reference of engineers or specification committees.

Free Vibrations and First Critical Loads of Tapered Columns (변단면 기둥의 자유진동 및 최소임계하중 해석)

  • 이병구;오상진;모정만;김헌상
    • Journal of KSNVE
    • /
    • v.2 no.3
    • /
    • pp.203-211
    • /
    • 1992
  • The main purpose of this paper is to present both the natural frequencies and the first critical loads of tapered columns. The ordinary differential equation governing the free vibration for tapered columns under compressive axial force is derived. Three kinds of cross sectional shape are considered in the governing equation. The Runge-Kutta method and determinant search method are used to perform the integration of the differential equation and to determine the natural frequencies, respectively. Additionally, the bisection method is used to determine the critical loads. In numerical examples, the effects of compressive axial force on the natural frequencies of tapered columns are investigated varying the end conditions. The first critical loads of tapered columns are determined on the basis of dynamic concepts. The first critical loads of tapered columns are determined on the basis of dynamic concept. The effects of cross sectional shapes are shown and some typical mode shapes are also presented.

  • PDF

Critical Buckling Loads of Laminated Composites under Cylindrical Bending (원통형 굽힘을 받는 적층판의 임계좌굴 하중)

  • Lee, Soo-Yong
    • Journal of Aerospace System Engineering
    • /
    • v.1 no.4
    • /
    • pp.28-36
    • /
    • 2007
  • This paper presents critical buckling loads of laminated composites under cylindrical bending. In-plane displacements are assumed to vary exponentially through plate thickness. The accuracy of this theory is examined for symmetric/antisymmetric cross-ply, angle-ply and unsymmetric laminates under cylindrical bending. Analytical solutions are provided to investigate the effect of transverse shear deformation on critical buckling loads of the laminated plates, and the results are compared with those obtained from the first-order shear deformation plate theory and the classical laminated plate theory.

  • PDF

Stability of unbraced frames under non-proportional loading

  • Xu, L.;Liu, Y.;Chen, J.
    • Structural Engineering and Mechanics
    • /
    • v.11 no.1
    • /
    • pp.1-16
    • /
    • 2001
  • This paper discusses the elastic stability of unbraced frames under non-proportional loading based on the concept of storey-based buckling. Unlike the case of proportional loading, in which the load pattern is predefined, load patterns for non-proportional loading are unknown, and there may be various load patterns that will correspond to different critical buckling loads of the frame. The problem of determining elastic critical loads of unbraced frames under non-proportional loading is expressed as the minimization and maximization problem with subject to stability constraints and is solved by a linear programming method. The minimum and maximum loads represent the lower and upper bounds of critical loads for unbraced frames and provide realistic estimation of stability capacities of the frame under extreme load cases. The proposed approach of evaluating the stability of unbraced frames under non-proportional loading has taken into account the variability of magnitudes and patterns of loads, therefore, it is recommended for the design practice.

Load-carrying capacities and failure modes of scaffold-shoring systems, Part I: Modeling and experiments

  • Huang, Y.L.;Chen, H.J.;Rosowsky, D.V.;Kao, Y.G.
    • Structural Engineering and Mechanics
    • /
    • v.10 no.1
    • /
    • pp.53-66
    • /
    • 2000
  • This paper proposes a simple numerical model for use in a finite analysis (FEA) of scaffold-shoring systems. The structural model consists of a single set of multiple-story scaffolds with constraints in the out-of-plane direction at every connection joint between stories. Although this model has only two dimensions (termed the 2-D model), it is derived from the analysis of a complete scaffold-shoring system and represents the structural behavior of a complete three-dimensional system. Experimental testing of scaffolds up to three stories in height conducted in the laboratory, along with an outdoor test of a five-story scaffold system, were used to validate the 2-D model. Both failure modes and critical loads were compared. In the comparison of failure modes, the computational results agree very well with the test results. However, in the comparison of critical loads, computational results were consistently somewhat greater than test results. The decreasing trends of critical loads with number of stories in both the test and simulation results were similar. After investigations to explain the differences between the computationally and experimentally determined critical loads, it was recommended that the 2-D model be used as the numerical model in subsequent analysis. In addition, the computational critical loads were calibrated and revised in accordance with the experimental critical loads, and the revised critical loads were then used as load-carrying capacities for scaffold-shoring systems for any number of stories. Finally, a simple procedure is suggested for determining load-carrying capacities of scaffold-shoring systems of heights other than those considered in this study.

A Seamless and Autonomous Mode Transfer Method of Grid-connected Inverter in Microgrid (마이크로그리드에서 계통연계 인버터의 자율적이며 끊김없는 모드전환 기법)

  • Park, Sung-Youl;Kwon, Min-Ho;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.5
    • /
    • pp.349-355
    • /
    • 2019
  • A grid-connected inverter with critical loads should be able to supply a stable voltage to critical loads at mode change and during clearing time while detecting unintentional islanding. This study proposes a mode transfer method for a grid-connected inverter with critical loads. The proposed method, which integrates the grid-connected and islanded mode control loops into one control block, provides an autonomous and seamless mode transfer from the current control to the voltage control. Therefore, the proposed scheme can supply a stable voltage to critical loads at mode change and during clearing time. Experimental results are provided to validate the proposed method.