• Title/Summary/Keyword: critical coefficient

Search Result 922, Processing Time 0.027 seconds

Evaluation of critical speed & running performance for Swing Motion Bogie (스웡모션보기의 임계속도와 주행성능 평가)

  • 함영삼;허현무;오택열
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.892-897
    • /
    • 2002
  • The research was requested by Meridian Rail Corporation in United States. The Swing Motion Bogie can application by Korea style if synthesize study result of bogie strength evaluation, bogie dynamic characteristics analysis, actual test(maximum speed, derailment coefficient, lateral force, vertical force, vibration acceleration, steady state lateral acceleration) etc..

  • PDF

The study of ionization and attachment coefficients in $CF_4$ molecular gas by Boltzmann equation (볼츠만 방정식에 의한 $CF_4$ 분자가스의 전리 및 부착계수에 관한 연구)

  • Song, Byoung-Doo;Ha, Sung-Chul;Jeon, Byoung-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.628-631
    • /
    • 2004
  • A tetrafluoromethane$(CF_4)$ is most useful gas in plasma dry etching, because it has a electron attachment cross-section. therefor it is important to calculate transport coefficients like electron drift velocity, ionization coefficient, attachment coefficient, effective ionization coefficient. and critical E/N. The aim of this study is to get these transport coefficients for information of the insulation strength and efficiency of etching process. Electron transport coefficients in $CF_4+Ar$ gas mixture are simulated in range of E/N values from 1 to 250 [Td] at 300[K} and 1 [Torr] by using Boltzmann equation method. The results of this method can be important data to present characteristic of gas for plasma etching and insulation, specially critical E/N is a data to evaluate insulation strength of a gas. and is presented in this paper for various mixture ratios of $CF_4+Ar$ gas mixture.

  • PDF

The chatter vibration in metal cutting using the low stiffness tool (저강성 공구를 이용한 절삭에서의 채터 진동)

  • 김정석;이병호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.3
    • /
    • pp.424-432
    • /
    • 1989
  • A mathematical model is developed for determination of the dynamic cutting force from static cutting data. The dynamic cutting force is analytically expressed by the static cutting coefficient and the dynamic cutting coefficient which can be determined from the cutting mechanics. The proposed model is verified by the chatter stability charts. A good agreement was shown between the stability limits predicted by the theory and the critical width of cut determined by experiments. The static cutting coefficient dominates high speed chatter stability, while the dynamic cutting coefficient dominates low speed chatter stability.

Reliability of Portable Spirometry Performed in the Korea National Health and Nutrition Examination Survey Compared to Conventional Spirometry

  • Park, Hye Jung;Rhee, Chin Kook;Yoo, Kwang Ha;Park, Yong Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.4
    • /
    • pp.274-281
    • /
    • 2021
  • Background: The Korea National Health and Nutrition Examination Survey (KNHANES) is a well-designed survey to collect national data, which many researchers have used for their studies. In KNHANES, although portable spirometry was used, its reliability has not been verified. Methods: We prospectively enrolled 58 participants from four Korean institutions. The participants were classified into normal pattern, obstructive pattern, and restrictive pattern groups according to their previous spirometry results. Lung function was estimated by conventional spirometry and portable spirometry, and the results were compared. Results: The intraclass correlation coefficients of forced vital capacity (FVC) (coefficient, 9.993; 95% confidence interval [CI], 0.988-0.996), forced expiratory volume in 1 second (FEV1) (coefficient, 0.997; 95% CI, 0.995-0.998), FEV1/FVC ratio (coefficient, 0.995; 95% CI, 0.992-0.997), and forced expiratory flow at 25-75% (FEF25-75%; coefficient, 0.991; 95% CI, 0.984-0.994) were excellent (all p<0.001). In the subgroup analysis, the results of the three parameters were similar in all groups. In the overall and subgroup analyses, Pearson's correlation of all the parameters was also excellent in the total (coefficient, 0.986-0.994; p<0.001) and subgroup analyses (coefficient, 0.915-0.995; p<0.001). In the paired t-test, FVC, FEV1/FVC, and FEF25-75% estimated by the two instruments were statistically different. However, FEV1 was not significantly different. Conclusion: Lung function estimated by portable spirometry was well-correlated with that estimated by conventional spirometry. Although the values had minimal differences between them, we suggest that the spirometry results from the KNHANES are reliable.

Determination of a critical damage by experiment and analysis of tensile test (인장시험의 실험과 해석 결과를 이용한 임계손상도의 결정)

  • Jang, S.M.;Eom, J.G.;Lee, M.C.;Joun, M.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.292-296
    • /
    • 2008
  • A new method of evaluating critical damage values of commercial materials is presented in this paper. The method is based on the previous study of the methodology [1] of acquisition of true stress-strain curves or flow stress curves over large strain from the tensile test in which the flow stress is described by the Hollomon law-like form, that is, by the strain dependent strength coefficient and the strain hardening exponent. The strain hardening exponent is calculated from the true strain at the necking point to meet the Considere condition. The strength coefficient is assumed to be constant before necking and represented by a piecewise linear function of strain after necking. With the predicted flow stress, a tensile test is simulated by a rigid-plastic finite element method with higher accuracy of less than 0.5% error between experiments and predictions. The instant when the fracture begins and thus the critical damage is obtained is determined by observing the stress variation at the necked region. It is assumed that the fracture due to damage begins when the pattern of stress around the necked region changes radically. The method is applied to evaluate the critical damage of a low carbon steel.

  • PDF

Critical Velocity of Fluidelastic Vibration in a Nuclear Fuel Bundle

  • Kim, Sang-Nyung;Jung, Sung-Yup
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.8
    • /
    • pp.816-822
    • /
    • 2000
  • In the core of the nuclear power plant of PWR, several cases of fuel failure by unknown causes have been experienced for various fuel types. From the common features of the failure pattern, failure lead time, flow conditions, and flow induced vibration characteristics in nuclear fuel bundles, it is deduced that the fretting wear failure of the fuel rod at the spacer grid position is due to the fluidelastic vibration. In the past, fluidelastic vibration was simulated by quasi -static semi-analytical model, so called the static model, which could not account for the interaction between the rods within a bundle. To overcome this defect and to provide for more flexibilities applicable to the fuel bundle, Tanaka's unsteady model was modified to accomodate the geometrical differences and governing parameter changes during the operations such as the number of rods, pitch to diameter ratio (P/D), spring force, damping coefficient, etc. The critical velocity was calculated by solving the governing equations with the MATLAB code. A comparison between the estimated critical velocity and the test result shows a good agreement. Finally, the level of decrease of the critical velocity due to the reduction in the spring force and reduced damping coefficient due to the radiation exposure is also estimated.

  • PDF

Development of Critical Thinking Skill Evaluation Scale for Nursing Students (간호대학생의 비판적 사고력 평가도구 개발)

  • You, So Young;Kim, Nam Cho
    • Journal of Korean Academy of Nursing
    • /
    • v.44 no.2
    • /
    • pp.129-138
    • /
    • 2014
  • Purpose: To develop a Critical Thinking Skill Test for Nursing Students. Methods: The construct concepts were drawn from a literature review and in-depth interviews with hospital nurses and surveys were conducted among students (n=607) from nursing colleges. The data were collected from September 13 to November 23, 2012 and analyzed using the SAS program, 9.2 version. The KR 20 coefficient for reliability, difficulty index, discrimination index, item-total correlation and known group technique for validity were performed. Results: Four domains and 27 skills were identified and 35 multiple choice items were developed. Thirty multiple choice items which had scores higher than .80 on the content validity index were selected for the pre test. From the analysis of the pre test data, a modified 30 items were selected for the main test. In the main test, the KR 20 coefficient was .70 and Corrected Item-Total Correlations range was .11-.38. There was a statistically significant difference between two academic systems (p=.001). Conclusion: The developed instrument is the first critical thinking skill test reflecting nursing perspectives in hospital settings and is expected to be utilized as a tool which contributes to improvement of the critical thinking ability of nursing students.

Frriction and Wear of Siamond-Like Carbon Films Produced by Plasma-Assisted CVD Technique

  • AkihiroTanaka;KazunoriUmeda;KazuyukiMizuhara;Ko, Myoung-Wan;Kim, Seong-Young;Shin, Seung-Yong;Lee, Sang-Hyun
    • The Korean Journal of Ceramics
    • /
    • v.3 no.3
    • /
    • pp.182-186
    • /
    • 1997
  • Diamond-like carbon(DLC) films were deposited on silicon substreates by using an RF plasmaassisted CVD apparatus; the effects of deposition conditions such as CH4 gas pressure and substrate bias voltage on DLC film friction and wear were examined in both friction and scratch tests. In friction tests critical loads at which the friction coefficient increases abruptly depend on substrate bias voltages: critical loads deposited at a bias voltage of -100 V exceed those deposited at other bias voltages. Critical loads are correlated with DLC film hydrogen content. Critical DLC film loads in scratch tests depended considerably less than in friction tests. The friction coefficient of DLC films depends on neither substrate bias voltage nor CH4 gas pressure.

  • PDF

Heat Transfer Characteristics of Spray Cooling Up to Critical Heat Flux on Thermoexcel-E Enhanced Surface (Thermoexcel-E 촉진 표면에서 임계 열유속까지의 분무 냉각 열전달 특성)

  • Lee, Yohan;Hong, Gwang-Wook;Lee, Jun-Soo;Jung, Dongsoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.9
    • /
    • pp.373-380
    • /
    • 2016
  • Spray cooling is a technology of increasing interest for electronic cooling and other high heat flux applications. In this study, heat transfer coefficients (HTCs) and critical heat fluxes (CHFs) are measured on a smooth square flat copper heater of $9.53{\times}9.53mm$ at $36^{\circ}C$ in a pool, a smooth flat surface and Thermoexcel-E surfaces are used to see the change in HTCs and CHFs according to the surface characteristics and FC-72 is used as the working fluid. FC-72 fluid has a significant influence on heat transfer characteristics of the spray over the cooling surface. HTCs are taken from $10kW/m^2$ to critical heat flux for all surfaces. Test results with Thermoexcel-E showed that CHFs of all enhanced surface is greatly improved. It can be said that surface form affects heat transfer coefficient and critical heat flux.