• Title/Summary/Keyword: critical charges

Search Result 34, Processing Time 0.022 seconds

Effects of Surface Charges on Hydrophobicity and Surface Potential Decay with Various Surface States of Silicone Rubber for Outdoor Insulator (옥외용 실리콘 절연재료의 발수성에 미치는 표면전하의 영향과 표면 상태에 따른 표면전위 감쇠)

  • 연복희;박충렬;허창수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.8
    • /
    • pp.678-686
    • /
    • 2002
  • This paper presents the effects of accumulation of surface charges on hydrophobic level and the changes of surface potential decay with various artificial environment treatments on high temperature vulcanized (HTV) silicone rubber used for outdoor insulating material. For this study, the charging apparatus by corona discharge, in which grid electrode was installed between the main corona and ground electrode, was used. From this study, it was found that the accumulation of surface charges above a critical surface potential on silicone insulating materials could lead to the temporary loss of surface hydrophobicity. In addition, corona stress and water absorption stress increase the decay rate of surface charges of HTV silicone rubber, while ultraviolet (UV) stress causes longer decay time. We could conclude that the effects of surface charges on hydrophobicity level and the changes of surface state by various artificial treatments were found through a trend of surface potential decay.

Failure Modeling of Bridge Components Subjected to Blast Loading Part II: Estimation of the Capacity and Critical Charge

  • Quintero, Russ;Wei, Jun;Galati, Nestore;Nanni, Antonio
    • International Journal of Concrete Structures and Materials
    • /
    • v.1 no.1
    • /
    • pp.29-36
    • /
    • 2007
  • The purpose of this paper is the assessment of the capacity of the reinforced concrete (RC) elements of an arch bridge when they are subjected to contact and near-contact explosive charges of various amounts, and the estimation of the critical charges for these components. The bridge considered is the Tenza Viaduct, a decommissioned structure south of Naples, Italy. Its primary elements, deck, piers and arches were analyzed. The evaluation was accomplished via numerical analyses that made possible to obtain the elements dynamic response when they are exposed to blast loading conditions. To evaluate the member's capacities, failure criteria for deck, piers and arches were proposed based on concrete damage parameters. Additionally, curves relating the explosive charge to the residual capacity and to damage level of the elements were also developed. The results of this work were taken into account to investigate the progressive collapse of the global structure.

Effect of Surface Charge in Hydrophobicity of Insulating Material and Decay of Surface Voltage after Corona Charging

  • Huh, Chang-Su;Youn, Bok-Hee;Seo, You-Jin;Hwang, Sun-Mook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.1-5
    • /
    • 2003
  • This paper presented the effects of accumulation of surface charges on hydrophobicity level and the surface states of silicone polymer used for outdoor insulator treated by ultraviolet irradiation and corona discharge through measuring surface voltage decay of a corona-charged specimen were investigated. The surface resistivity by the method of the surface potential decay was compared with the value by the three electrodes methods. From this study, it was found that the accumulation of surface charges above a critical surface voltage on silicone insulating materials could lead to the temporary loss of surface hydrophobicity. In addtion, uv stress lead to a longer decay time of surface charges. We could conclude that the effects of surface charges on hydrophocity level and the changes of surface state by various artificial treatments were understood through a trend of surface potential decay.

  • PDF

Failure Modeling of Bridge Components Subjected to Blast Loading Part I: Strain Rate-Dependent Damage Model for Concrete

  • Wei, Jun;Quintero, Russ;Galati, Nestore;Nanni, Antonio
    • International Journal of Concrete Structures and Materials
    • /
    • v.1 no.1
    • /
    • pp.19-28
    • /
    • 2007
  • A dynamic constitutive damage model for reinforced concrete (RC) structures and formulations of blast loading for contact or near-contact charges are considered and adapted from literatures. The model and the formulations are applied to the input parameters needed in commercial finite element method (FEM) codes which is validated by the laboratory blast tests of RC slabs from literature. The results indicate that the dynamic constitutive damage model based on the damage mechanics and the blast loading formulations work well. The framework on the dynamic constitutive damage model and the blast loading equations can therefore be used for the simulation of failure of bridge components in engineering applications.

Implementation and Outcomes of a Critical Pathway for Lumbar Laminectomy or Microdiscectomy

  • Chung, Sang-Bong;Lee, Sun-Ho;Kim, Eun-Sang;Eoh, Whan
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.6
    • /
    • pp.338-342
    • /
    • 2012
  • Objective : The aim of this study is to implement a critical pathway (CP) for patients undergoing lumbar laminectomy or microdiscectomy and describe the results before and after the CP in terms of length of hospital stay and cost. Methods : From March 2008 to February 2009, 61 patients underwent lumbar laminectomy or microdiscectomy due to stenosis or one- or two-level disc herniation in our department and were included in the prepathway group. After development and implementation of the CP in March 2009, 58 patients were applicable for the CP, and these were classified as the postpathway group. Results : The CP, which established a 6-day hospital stay (5 bed-days), was fulfilled by 42 patients (72.4%) in the postpathway group. The mean length of stay was 5.4 days in the postpathway group compared to 6.9 days in the prepathway group, demonstrating a 20% reduction, which was a statistically significant difference ($p{\leq}0.000$). There was a statistically significant reduction in charges for bed and nursing care (p=0.002). Conclusion : Implementation of a CP for lumbar laminectomy or microdiscectomy produced significant decreases in length of hospitalization and charges for bed and nursing care. We believe that this CP reduces the unnecessary use of hospital resources without increasing risk of adverse events.

Effects of Critical Pathway(CP) on the patients with Primary Total hip replacement(THR) (고관절 전치환술 환자의 Critical pathway적용효과)

  • Lee, Mi-Kyoung;Doh, Bok-Num
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.8 no.2
    • /
    • pp.295-308
    • /
    • 2002
  • Purpose: The purpose of this quasi-experimental research is to develop the CP for primary THR patients and verify its effectiveness. Method: The CP is designed for both patients and medical employees to meet the 14-day-long hospitalization with an expert and clinical validity test, and the standardized orders are also created. 21 eligible subjects for the control group(with common care plan) and 27 subjects for the experimental group(with CP service) were assigned. Data were collected from questionnaires to evaluate patients' satisfaction level of nursing care and CP, investigation of physical complications, inspection of LOS(length of hospital stay) and hospital charges from April 2000 to February 2001 at K-hospital in Daegu. The collected data were analyzed by using the SAS program. Results: After implementation of CP, there was a statistically significant reduction in mean length of stay. The hospital charges have no considerable difference between two groups. Frequency of physical complications is reduced considerably. The experimental group scored much higher than the control group on the satisfaction level toward nursing care. And in the analysis of CP satisfaction questionnaires, many subjects have high satisfaction in items of 'I see the treatment process and hospital life', 'I feel that I am participating in my treatment process with health care staff'. The analysis of variances which cause a prolonged LOS supports that it's necessary to strengthen an evaluation of pre-operative outpatients' condition and link the home nursing care system in discharge for more shortening of LOS. Conclusion: The above results show that CP can have a positive impact on satisfaction level of inpatients with primary THR and the hospital.

  • PDF

A Pilot Study on Effects of Critical Pathway Application for Hwa-Byung (화병 표준진료지침 적용효과에 대한 Pilot 분석)

  • Eom, Yoon-Ji;Kwon, Do-Hyung;Kim, Yun-Na;Lee, Hyun-Woo;Chung, Sun-Yong;Cho, Seung-Hun
    • Journal of Oriental Neuropsychiatry
    • /
    • v.32 no.4
    • /
    • pp.337-343
    • /
    • 2021
  • Objectives: To investigate effectiveness and satisfaction of applying critical pathway (CP) to Hwa-byung outpatients. Methods: Subjects were 32 outpatients who were diagnosed with Hwa-byung between January 1 and 2021 to October 31, 2021. Among these patients, 18 patients were applied with CP and 14 patients received treatment without applying CP. Their medical records and administration records were retrospectively analyzed. Data were analyzed by mean, standard deviation, and t-test using SPSS 26.0 program. Results: Mean total treatment period significantly decreased in the CP group compared with the non-CP group. Medical expenses were classified by treatment period, per visit, and patient charges per type of visit. When analyzed specifically by detailed items, there was a decreasing tendency in total medical expenses, uncovered medical expenses, and patient charges but an increasing tendency in covered medical expenses, although some of these changes were not statistically significant. Satisfaction score increased in the CP group compared with the non-CP group in general, although not all increases were statistically significant. Conclusions: Applying CP may contribute to the reduction of medical expenses and improvement of medical service quality. Further research on the development of CP for various diseases and the application of CP under various circumstances is needed.

Study on e-Learning Users' Motivation and Satisfaction for its Growth (이러닝 활성화를 위한 이용자의 이용 동기와 만족도에 관한 실증적 연구)

  • Baek, Hyen-Ki;Ha, Tai-Hayun;Kang, Jung-Hwa
    • Journal of Digital Convergence
    • /
    • v.5 no.1
    • /
    • pp.131-140
    • /
    • 2007
  • This paper studies characteristics of e-Learning users' motivation, attitudes and satisfaction. For this purpose, surveys were conducted of university students who choose e-Learning as one of main learning tools. The research found that stable service and proper service charges were critical to the loyalty to e-Learning service. It also showed that both quality and quantity of contents were very important factors to e-Learning growth.

  • PDF

A Study on Shock Transmission of Pyrotechnic Initiator (격벽착화기 내 충격 전달에 관한 연구)

  • Kim, Bohoon;Kim, Minsung;Yoh, Jai-ick
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.223-226
    • /
    • 2015
  • A pyrotechnic system that consists of donor/acceptor pair separated by a gap relies on shock attenuation characteristics of the gap material and shock sensitivity of the donor and acceptor charges. We apply a level-set based multimaterial hydrocode with reactive flow models for pentolite donor and heavily aluminized RDX as acceptor charge. The complex shock interaction, critical gap thickness, acoustic impedance, and go/no-go characteristics of the pyrotechnic system are quantitatively investigated.

  • PDF

Partial Charge and CMC Characteristics of Hydrophilic and Hydrophobic Group of Surfactants (Cationic and Amphoteric Surfactant) (계면활성제의 친수.소수성 그룹의 부분전하와 CMC특성 (양이온 및 양쪽성 계면활성제))

  • 하윤식
    • Journal of Environmental Science International
    • /
    • v.9 no.5
    • /
    • pp.403-408
    • /
    • 2000
  • On the basis of theory of Bratsch's electronegativity equalization the electronegativity equalization the group electronegativities and the group partial charges for cationic and amphoteric surface and amphoteric surfactants could be calculated using Pauling's electronegativity parameters. From calculated output we have investigated relationships between CMC(critical micelle concentration) and partial charge and group electronegativity of hydrophilic and hydrophobic groups structural stability of micelle for cationic and amphoteric surfactants. As a result CMC depends upon partial charge and electronegativity of hydrophilic group is decreased. With increasing the carbon number of hydrophilic group for cationic surfactant its partial charge is increased but CMC and its electronegativity are decreased. With increasing the carbon number of hydrophobic group for cationic and amphoteric surfactant its partial charge is increased but CMC andits electronegativity are decreased.

  • PDF