• 제목/요약/키워드: criterion

검색결과 6,805건 처리시간 0.034초

공형압연에서 소재 주름흠 발생 해석 - 유한요소해석 (Analysis of wrinkle Initiation on Workpiece in Groove Rolling - Finite Element Analysis)

  • 나두현;조오영;이종호;이용희;이영석
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 춘계학술대회 논문집
    • /
    • pp.415-418
    • /
    • 2008
  • We propose a criterion which predicts wrinkle initiation on workpiece in groove rolling process based on finite element analysis. Fundamental idea introduced in the criterion is to examine the difference between flat rolling which don't' cause wrinkling at all and groove rolling which usually accompanies it. The proposed criterion assumes that irregular distribution of shear strain on workpiece during groove rolling is attributable to the initiation of wrinkling. The proposed criterion has been applied to roughing train in the rod and bar mill of SEAH BESTEEL Inc. A new design for 2nd pass (square roll groove) was suggested, machined and applied. Results reveal that the proposed criterion in this study could point out the location of wrinkle initiation during groove rolling and could reduce onset of wrinkle on final products.

  • PDF

지반-구조물 상호작용 해석의 단순화된 기준에 대한 평가 (Evaluation of a Simplified Criterion for SSI Analysis)

  • 김재민;김원희;현창헌
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.337-344
    • /
    • 2006
  • This paper is concerned with the simplified criterion given in ASCE 4-98, for determining whether soil-structure interaction (SSI) analysis is required for seismic response analysis of nuclear power plant structures. In this study, the criterion is evaluated for a couple of example structures including an existing nuclear power plant and the Hualien large-scale seismic test building. Forced vibration analysis and seismic response analysis are carried out using the simple stick model with soil springs and an elaborated SSI analytical model. From the numerical analyses, it is found that the criterion may not allow the fixed-base analysis for bedrock with shear wave velocity of greater than 1,100m/s which is a well-known criterion for a rock site. In addition, it is indicated that peak amplification as well as the peak broadening specified in NRC RG 1.122. shall be considered to include the effects of SSI.

  • PDF

Least absolute deviation estimator based consistent model selection in regression

  • Shende, K.S.;Kashid, D.N.
    • Communications for Statistical Applications and Methods
    • /
    • 제26권3호
    • /
    • pp.273-293
    • /
    • 2019
  • We consider the problem of model selection in multiple linear regression with outliers and non-normal error distributions. In this article, the robust model selection criterion is proposed based on the robust estimation method with the least absolute deviation (LAD). The proposed criterion is shown to be consistent. We suggest proposed criterion based algorithms that are suitable for a large number of predictors in the model. These algorithms select only relevant predictor variables with probability one for large sample sizes. An exhaustive simulation study shows that the criterion performs well. However, the proposed criterion is applied to a real data set to examine its applicability. The simulation results show the proficiency of algorithms in the presence of outliers, non-normal distribution, and multicollinearity.

전력용 변압기 온라인 유중가스 진단기준치 및 알고리즘에 관한 연구 (Study on the Criterion and Algorithm for On-line Dissolved Gas of a Power Transformer)

  • 권동진;곽주식;곽희로;김재철;진상범
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.206-212
    • /
    • 2005
  • In this paper, criterion and algorithm for on-line dissolved gas of a Power transformer are studied. For the initial diagnosis of a power transformer, the on-line dissolved gas analysis is one of the most important and acceptable item to preventively diagnose a power transformer. But the criterion and algorithm of this item are not established yet in korea. In this paper, criterion and alarm level of the on-line dissolved gas analysis are based on the analysis of on-line data of operating transformers, Korea industrial standard and operation manual for a power transformer as well as accumulated data of the preventive diagnosis systems which have been operated at nine substations of Korea Electric Power Co.(KEPCO) since 1997, Therefore, the criterion and alarm level proposed in this paper are to be well suitable and are adaptable for the domestic operational environments and conditions of the power transformer. Considering that the conventional diagnosis system is capable only of accumulating and monitoring data of the power transformer operation, the criteria and the algorithms make it possible to accomplish an ultimate goal of the preventive diagnosis system. It is expected, therefore, that they will have a beneficial effect on broad applications of the preventive diagnosis system and the achievement of manless substation system in the future.

국제무역환경 변화에 따른 대외무역법 원산지제도의 개선방안에 관한 연구 (A Study on the Improvement of Rules of Origin in the Korea Foreign Trade Act in the Global Trade Circumstances)

  • 박광서;이병문;오원석
    • 무역상무연구
    • /
    • 제41권
    • /
    • pp.267-292
    • /
    • 2009
  • It is a right time to improve the Korea Foreign Trade Act(KFTA) as a fundamental law on Rules of Origin(RoO) in the global trade circumstances which are summarized FTA and WTO. The KFTA's RoO constitutes the labelling system of the Country of Origin, the criterion of it, the issuing of certificate of origin and the punishing offender mainly around the importing goods. This study has focused on the problems of KFTA's RoO at the macro and practical level, and proposed the programs to improve the KFTA's RoO about importing, exporting and domestic production goods. KFTA need to create a purpose clause to protect consumers and industries also, and has to be located a general and top position in the RoO of Korea. In the concrete, the labelling system of the Country of Origin has to set limited in the point of minimum necessity view. The criterion of the Country of Origin also has to improve the wholly obtained criterion, the changing in tariff classification criterion, value added criterion and processing operation criterion to harmonize WTO Rules of Origin and FTA Rules of Origin. The punishment ceiling against offender has to raise to guarantee the effectiveness of RoO.

  • PDF

Nonlinear analysis of RC beams strengthened by externally bonded plates

  • Park, Jae-Guen;Lee, Kwang-Myong;Shin, Hyun-Mock;Park, Yoon-Je
    • Computers and Concrete
    • /
    • 제4권2호
    • /
    • pp.119-134
    • /
    • 2007
  • External bonding of steel or FRP plates to reinforced concrete (RC) structures has been a popular method for strengthening RC structures; however, unexpected premature failure often occurs due to debonding between the concrete and the epoxy. We proposed a Coulomb criterion with a constant failure surface as the debonding failure criterion for the concrete-epoxy interface. Diagonal shear bonding tests were conducted to determine the debonding properties that were related to the failure criterion, such as the angle of internal friction and the coefficient of cohesion. In addition, an interface element that utilized the Coulomb criterion was implemented in a nonlinear finite element analysis program to simulate debonding failure behavior. Experimental studies and numerical analysies on RC beams strengthened by an externally bonded steel or FRP plate were used to determine the range of the coefficient of cohesion. The results that were presented prove that premature failure loads of strengthened RC beams can be predicted with using the bonding properties and the finite element program with including the proposed Coulomb criterion.

간선도로 좌곡선부 전후구간 수막현상 방지를 위한 종·횡단경사 조합 적용방안 (A Method of Compounding Application of Longitudinal Grade and Superelevation on Left Curved Section in Arterial for Preventing Hydroplaning)

  • 정지환;오흥운
    • 한국도로학회논문집
    • /
    • 제17권1호
    • /
    • pp.105-118
    • /
    • 2015
  • PURPOSES : This study aims to evaluate the road safety of the super-elevation transition section of a left turn curve and suggest the minimum longitudinal grade of a super-elevation transition section to be used before and after a left curved section. METHODS : We evaluated the road condition by means of the safety-criterion-evaluation method involving side friction factors, and then solve the problem by introducing the minimum longitudinal grade criterion based on conditions described in the hydraulics literature. RESULTS : It was calculated that when a road satisfies hydroplaning conditions, the difference between side friction assumed and side friction demanded is less than -0.04. In this case, the safety criterion for the condition is unsatisfied. Conversely, when a road is in a normal state under either wet or dry conditions, it was calculated that the difference between side friction assumed and side friction demanded is more than 0.01. Thus, the safety criterion for this condition is found to be satisfied. After adjusting the minimum longitudinal grade applied to a super-elevation transition section, the hydroplaning condition can be eliminated and the safety criterion can be met for all sections. CONCLUSIONS : It is suggested that a minimum longitudinal grade should be provided on super-elevation transition sections in order to prevent hydroplaning.

Experimental Determination of Concrete Fracture Properties with Modified S-FPZ Model

  • Yon, Jung-Heum;Kim, Tai-Hoon
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권3E호
    • /
    • pp.213-219
    • /
    • 2006
  • Modified singular fracture process zone(S-FPZ) model is proposed in this paper to determine a fracture criterion for continuous crack propagation in concrete. The investigated fracture properties of the proposed fracture model are strain energy release rate at a micro-crack tip and the relationship between crack closure stress(CCS) and crack opening displacement(COD) in the FPZ. The proposed model can simulate the actual fracture energy of experimental results fairly well. The results of the experimental data analysis show that specimen geometry and loading condition did not affect the CCS-COD relation. However, the strain energy release rate is a function of not only specimen geometry but also crack extension. The strain energy release rate remained constantly at the minimum value up to the crack extension of 25 mm, and then it increased linearly to the maximum value. The maximum fracture criterion occurred at the peak load for specimens of large size. The fracture criterion remained at the maximum value after the peak load. The variation of the fracture criterion is caused by micro-cracking and micro-crack localization. The fracture criterion of strain energy release rate can simply be the size effect of concrete fracture, and it can be used to quantify the micro-cracking and micro-crack localizing behavior of concrete.

A new strain-based criterion for evaluating tunnel stability

  • Daraei, Ako;Zare, Shokrollah
    • Geomechanics and Engineering
    • /
    • 제16권2호
    • /
    • pp.205-215
    • /
    • 2018
  • Strain-based criteria are known as a direct method in determining the stability of the geomechanical structures. In spite of the widely use of Sakurai critical strain criterion, it is so conservative to make use of them in rocks with initial plastic deformation on account of the considerable difference between the failure and critical strains. In this study, a new criterion has been developed on the basis of the failure strain to attain more reasonable results in determining the stability status of the tunnels excavated in the rocks mostly characterized by plastic-elastic/plastic behavior. Firstly, the stress-strain curve was obtained having conducted uniaxial compression strength tests on 91 samples of eight rock types. Then, the initial plastic deformation was omitted making use of axis translation technique and the criterion was presented allowing for the modified secant modulus and by use of the failure strain. The results depicted that the use of failure strain criterion in such rocks not only decreases the conservativeness of the critical strain criterion up to 42%, but also it determines the stability status of the tunnel more accurately.

절리암반사면의 안정해석 방법에 관한 비교연구 (A Comarative study on slope stability modeling of highly fractured rock slopes)

  • 유충식;김선빈;양기호;정하승
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.434-443
    • /
    • 2009
  • Slope stability analysis is an essential part of rock slope design. For highly fractured rock, the limit equilibrium method (LEM) based slope stability analysis with a circular failure surface is often carried out assuming the rock mass behaves more or less as a continuum. This paper examines first, the applicability of the finite-element method (FEM) based shear strength reduction (SSR) technique for highly fractured rock slope, and second the use of Mohr-Coulomb (MC) failure criterion in conjunction with generalized Hoek-Brown (HB) failure criterion. The numerical results on a number of cases are compared in terms of the factor of safety (FS). The results indicated that the FEM-based SSR technique yields almost the same FSs from LEM, and that the MC and HB failure criteria yield almost identical FSs when the strength parameters for MC failure criterion are obtained based on the modified HB failure criterion if and only if value of the Hoek-Brown constant $m_i$ is smaller than 10 and slope angle is smaller than 1:1, otherwise MC failure criteria over-estimate the factor of safety.

  • PDF