• Title/Summary/Keyword: criteria of deterioration

Search Result 154, Processing Time 0.034 seconds

Moment curvature method for fire safety design of steel beams

  • Yu, H.X.;Richard Liew, J.Y.
    • Steel and Composite Structures
    • /
    • v.4 no.3
    • /
    • pp.227-246
    • /
    • 2004
  • This paper presents a moment-curvature method that accounts for the strength deterioration of steel at elevated temperature in estimating the response of steel beams exposed to fire. A modification to the EC4 method is proposed for a better estimation of the temperature distribution in the steel beam supporting a concrete slab. The accuracy of the proposed method is verified by comparing the results with established test results and the nonlinear finite element analysis results. The beam failure criterion based on a maximum strain of 0.02 is proposed to assess the limiting temperature as compared to the traditional criteria that rely on deflection limit or deflection rate. Extensive studies carried out on steel beams with various span lengths, load ratios, beam sizes and loading types show that the proposed failure criterion gives consistent results when compared to nonlinear finite element results.

A Study on Standard of Performance Evaluation for Paper Shredder (문서세단기 성능평가방법의 표준화에 관한 연구)

  • 이동규;유송민;이위로;노대호;김민호
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.122-127
    • /
    • 2004
  • The purpose of this study is to introduce the standard of the durability and evaluation method for paper shredder. The major evaluation criteria include shredding capability, shredding blade (or cutter) hardness and edge roughness, and durability. Due to the difficulties in assessing the durability directly, performance deterioration of the shredder was assessed by measuring the torque variation along with the variation in shredded chip size and load, thereby proposing the indirect method of assessing the paper shredder durability.

  • PDF

Failure Risk Assessment of Reinforced Concrete Sewer Pipes on Joint-Related Defects (원심력철근콘크리트관의 결함에 따른 심각도 평가 -이음부 사례를 중심으로-)

  • Han, Sangjong;Shin, Hyunjun;Hwang, Hwankook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.787-796
    • /
    • 2013
  • Sewer joint-related defect is one of the most common domestic sewer defects along with the lateral pipe problem. However, there are currently no criteria that precisely assess the joint-related sewer defects. Therefore, this study examined the joint-related sewer defects found in domestic circumstances, classified them according to the suggested defect code, and presented the examples of defect pictures. Each defect code was organized as the process of out of pipeline alignment (OPA) which shows the progress in deterioration. Each defect was classified into 5 grades depending on appropriate repair and rehabilitation method. The result of this study is expected to be useful for domestic CCTV inspectors to assess the sewer condition and helpful for managers to make a decision of repair and rehabilitation.

Pediatric mandibular chronic nonbacterial osteomyelitis: A case report with 12 years of radiologic follow-up

  • Sehyun Choi;Min-Ji Kim;Sang-Hoon Kang;In-Woo Park
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.93-104
    • /
    • 2024
  • Chronic nonbacterial osteomyelitis(CNO) is histologically characterized by nonspecific osteitis. This inflammatory disorder, which lacks an infectious origin, typically presents with chronic pain and swelling at the affected site that can persist for months or even years. However, it is rare for CNO to affect the mandible. A 10-year-old girl presented with a primary complaint of pain in her left mandible. She had no significant medical or dental history. On examination, swelling was visible on the left buccal side, and imaging revealed radiolucent bone deterioration within the left mandible. This case report presents the radiological changes observed over a 12-year follow-up period. Variations in radiopacity, radiolucency, and periosteal reactions were noted periodically. This case highlights the radiological characteristics and findings that are crucial for the diagnosis of CNO, a condition for which no clear diagnostic criteria are currently available.

The Influence of Forest Fire Simulation on the Properties of Polymer Insulators

  • Lee, Won-Kyo;Choi, In-Hyuk;Lee, Dong-Il;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.161-164
    • /
    • 2009
  • Forest fire simulation tests were performed with polymer and porcelain insulators at GOCHANG Power Testing Center. These tests consisted of open flames causing a temperature rise of up to $600{\sim}800^{\circ}C$ measured at the insulator surfaces. Mechanical and electrical characteristics such as the specific mechanical load, the low frequency dry flashover voltage and the impulse flashover voltage were analyzed for the polymer insulators before, during and after the simulation tests and then compared to the porcelain insulators. At the end of the fire simulation tests, there was no detrimental deterioration of any of the insulators. All the insulators passed the KEPCO specification criteria. This study showed that the forest fire simulation had no impact on the polymer insulators.

A Study on the reliability analysis of Forest Fire on Polymer Insulators (폴리머 애자의 산불 신뢰성 평가 연구)

  • Lee, Won-Kyo;Choi, In-Hyuk;Hwang, Kab-Cheol;Choi, Han-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.460-461
    • /
    • 2008
  • The forest fire simulation tests were performed with polymer and porcelain insulators at Gochang testing center. These tests consisted of energizing 90 kV at line-to-ground voltage of 154 kV lines and open flame rising up to $600-630^{\circ}C$ as being measured at insulator surface. Mechanical and electrical characteristics such as specific mechanical load, leakage current, low frequency dry flashover voltage and impulse flashover voltage were analyzed for the polymer insulators before, during and after simulation tests compared with porcelain insulators. At the end of fire simulation tests, there was no detrimental deterioration of any insulators. All insulators passed the criteria of KEPCO specification. This study showed that forest fire simulation had no impact on polymer insulators.

  • PDF

A Study on the Optimal Distance and Heating Energy with relation to Site Planning of Apartment Building (아파트 배치형태에 따른 적정 인동거리와 난방에너지에 대한 연구)

  • Jung, Doo-Woon;Choi, Chang-Ho;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.97-107
    • /
    • 2003
  • Recently, the apartment building has been constructed in large quantities to provide housings due to the gravitation of population towards large cities. However, we're faced with a critical problem of deterioration of our dwelling environment caused by the trend toward high-rise apartment which could be an obstruction in obtaining sufficient sunlight. Therefore, there have been several legislative actions against infringement on the right of sunshine. In the building law, sunshine hours and the minimal separated distance between apartments are regulated as the criteria for the site planning, However, the minimal separated distance was defined without consideration of the parameters like building orientation and thermal effect of the sunshine hours in the site planning for the apartment building. In this study, the sunshine hours and heating energy during the underheated season for various arrangements in site planning are carefully considered and analyzed.

Proposed Development and Evaluation System for Existing Standardized Waterproof Technology Assessment Methods (표준화된 방수기술 평가기법 개발 및 평가체계 구축)

  • Song, Je-Young;Lee, Sun-Gyu;Choi, Eun-Kyu;Lee, Jung-Hun;Kim, Byoungil;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.341-342
    • /
    • 2018
  • Waterproofing materials and construction methods have been developed and applied to various construction sites since the past. However, there many cases where the waterproofing performance is not satisfactory, leading to continuous water leakage. It has been observed that a key reason for this is because waterproofing method and material selection is not optimized in terms of the appropriate application area and environmental degradation factors. This paper proposes that future selection of waterproofing methods should consider the following evaluation criteria; 1) waterproof performance evaluation according to site conditions, 2) evaluation of construction method, 3) manufacturing and maintenance of waterproofing systems.

  • PDF

A Study on Reasonable Improvement of Legal Requirement for Fire Proofing for Steel Structures in a Chemical Plant (화학플랜트에서 철골구조물 내화기준의 합리적인 개선에 관한 연구)

  • Hwang, Soon-Yong;Char, Soon-Chul;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.1
    • /
    • pp.51-63
    • /
    • 2007
  • It is noted that the disaster such as fire, explosion, collapse has been rapidly increased caused by strength deterioration of steel structures at petrochemical plant during fire. In this regard, it is stressed out that the legal requirement for fire proofing for steel structures at petrochemical plant should be carefully reviewed since the current legal requirement such as Industrial Safety & Health Law, Architectural Law has a conflict and different way of approach. In addition, it is our point of view that the present law should be revised to consolidate into single law including engineering design criteria to reflect unreasonable legal requirement. It is further our point of view that the performance certificate for fire proofing like UL-1709, basis of maintenance should be appropriately and reasonably provided in line with global practice.

A study on the train passage control at railroad bridge under heavy rainfall (철도교량 홍수시 열차운전규제기준에 대한 연구)

  • Park, Young-Kon;Lee, Jin-Wook;Yoon, Hee-Taek;Mok, Jai-Kyun;Kim, Seon-Jong
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1001-1006
    • /
    • 2004
  • Railroad disasters are frequently occurred by man-made causes or natural causes. In general, man-made causes are illegal construction practices, deterioration with the lapse of time and railroad crossing accidents, and natural causes are rainfall. snow, wind, earthquake, etc. Of cause, railroad disasters by man-made causes are prevented from keeping the safety principle, constructing multi-level crossing, securing enough men of ability and financial resources and making a thorough check using equipments with high capacity. And railroad disasters by natural causes are also minimized by construction of disaster prevention facilities, introduction and operation of general disaster prevention system and reasonable train passage control. Therefore, to setup the criterion of train passage control for train safety at railroad bridge under heavy rainfall, risky factors, national and oversea criteria under such circumstances are reviewed and a scheme to setup the criterion is suggested.

  • PDF