• Title/Summary/Keyword: cracking failure

Search Result 571, Processing Time 0.028 seconds

Electric Fatigue Behavior of a Bending Piezoelectric Composite Actuator (굽힘 압전 복합재료 작동기의 전기적 피로 거동)

  • Woo, Sung-Choong;Goo, Nam-Seo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.362-367
    • /
    • 2008
  • In the present work, we address electric fatigue behavior in bending piezoelectric actuators using an acoustic emission technique. Electric cyclic fatigue tests have been performed up to ten million cycles on the fabricated specimens. To confirm the fatigue damage onset and its pathway, the source location and distributions of the AE behavior in terms of count rate are analyzed over the fatigue range. It is concluded that electric cyclic loading leads to fatigue damages such as transgranular damages and intergranular cracking in the surface of the PZT ceramic layer, and intergranular cracking even develops into the PZT inner layer, thereby degrading the displacement performance. The electric-induced fatigue behavior seems to show not a continuous process but a step-by-step process because of the brittleness of PZT ceramic. Nevertheless, this fatigue damage and cracking do not cause the final failure of the bending piezoelectric actuator loaded up to 107 cycles. Investigations of the AE behavior and the linear AE source location reveal that the onset time of the fatigue damage varies considerably depending on the existence of a glass-epoxy protecting layer.

  • PDF

INTERGRANULAR FAILURE ASSOCIATED WITH BOUNDARY SLIDING IN Pb-SN EUTECTIC SOLDERS USED FOR MICROELECTRONICS APPLICATIONS (Electronic Packaging에 쓰이는 공정 조성의 Pb-Sn Solders에서 Grain Boundary Sliding과 관련된 계면파괴현상)

  • Lee, Seong-Min
    • Korean Journal of Materials Research
    • /
    • v.4 no.3
    • /
    • pp.334-338
    • /
    • 1994
  • This report details the microscopic aspects of grain boundary cracking in Pb-Sn eutecticduring displacement-controlled mechanical tests performed over a range of low frequency ($10^{-3}-10^{-5}$/s)and moderate strain range (0.2 - 1 %) where is the most technologically relevant to solder jointssubjected to thermal cycling. It is shown that intergranular cracking begins with the appearance ofcrack-like features (CLF's), which can be seen due in part because they are associated with grainboundary sliding, and is able to be described by certain stages of isolated crack growth. In the initialstages CLF's are not ture cracks but instead what I shall call "proto-cracks" where grain boundarysliding begins to damage the gram boundary at the surface. At some point during the initiation stagesonce proto-cracks become ture cracks, they develop into isolated cracks and the growth of isolatedcracks is eventually accomplished by coalescence, resulting in 5 stages of cracking.ing in 5 stages of cracking.

  • PDF

Evaluation on Shear Behavior of Double-tee Dap-ends with the Least Depth from Optimization Proces (최적이론에 의하여 설계된 최소 깊이 더블티 댑단부 전단거동 평가)

  • 유승룡;김대훈
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.4
    • /
    • pp.43-54
    • /
    • 1999
  • Shear tests are performed on four full-scale 12.5 m proto-type models, "least depth double tee," which are resulted from the optimization process. Domestic superimposed live load regulation, domestic material properties which is available to product. Korean building code requirements, construction environments and economy are considered as the main factors to establish the process. All of the specimens tested fully comply with the shear strength requirements as specified by ACI 318-95. The research has shown following results. 1) The development length requirement of ACI 318-95 does not seem a good predictor for the estimation of bond failure in a beam with the strands below the supports. 2) The load required for the first initial coner cracking in the dap end and first web shear cracking does not seem to have any relation with the dimension and shear strength of the section in the test beams. 3) The strand slip has a direct relationship with the web shear cracking. However, the coner cracking in the dap end does not give any help for the slip in anchorage. 4) Use of whole area for bearing steel at the bottom of dap end is desired for safe bearing pressure design in the precast prestressed double tee beams. 5) The deflection of beam influences directly on the amount of strand slip at the anchorage after initiation of it, and relationship between them are very linear.

Effect of parameters on the tensile behaviour of textile-reinforced concrete composite: A numerical approach

  • Tien M. Tran;Hong X. Vu;Emmanuel Ferrier
    • Advances in concrete construction
    • /
    • v.16 no.2
    • /
    • pp.107-117
    • /
    • 2023
  • Textile-reinforced concrete composite (TRC) is a new alternative material that can satisfy sustainable development needs in the civil engineering field. Its mechanical behaviour and properties have been identified from the experimental works. However, it is necessary for a numerical approach to consider the effect of the parameters on TRC's behaviour with lower analysis duration and cost related to the experiment. This paper presents obtained results of the numerical modelling for TRC composite using the cracking model for the cementitious matrix in TRC. As a result, the TRC composite exhibited a strain-hardening behaviour with the cracking phase characterized by the drops in tensile stress on the stress-strain curve. This model also showed the failure mode by multi-cracking on the TRC specimen surface. Furthermore, the parametric studies showed the effect of several parameters on the TRC tensile behaviour, as the reinforcement ratio, the length and position of the deformation measurement zone, and elevated temperatures. These numerical results were compared with the experiment and showed a remarkable agreement for all cases of this study.

Development of P-PIE Program for Evaluating Failure Probability of Pipes in Nuclear Power Plants (원전 배관의 파손확률평가를 위한 P-PIE 프로그램의 개발)

  • Park, Jai-Hak;Lee, Jae-Bong;Choi, Young-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.1-8
    • /
    • 2010
  • P-PIE program is developed for evaluating failure probability of pipes in nuclear power plants based on the existing PRAISE program. In the program, crack growth due to fatigue loading and stress corrosion can be considered and the probability of fracture or leakage of pipes can be calculated. Crack growth simulation is performed based on stress intensity factor and a damage parameter and failure of a pipe is determined based on J integral or net section yielding. Using the developed program the failure probabilities of tubes in a domestic nuclear power is obtained and discussed.

Failure Analysis of Cracks in Ancient and Modern Bronze Spoons (고대와 현대 방짜수저의 균열발생 원인분석)

  • Choe, Byung Hak;Lee, Bum Gyu;Shim, Jong Hun;Go, Hyung Soon;Jo, Nam Chul;Lee, Jae Sung;Park, Kyung Gyun;Kim, Yu Chan
    • Korean Journal of Materials Research
    • /
    • v.26 no.10
    • /
    • pp.528-534
    • /
    • 2016
  • The aim of this paper is to consider the effect of the manufacturing processes on corrosion and centerline cracking of ancient bronze spoons. The ancient bronze spoons in question were made by several steps of forging, in reheated condition with cast ingots. The manufacturing method is similar to that of the modern spoons. The investigations include observations from light and scanning electron microscopes of the microstructure in terms of the crack propagation. Cracks in the centerline are caused by solute segregation in the center-line region; this solute is solidified in the final stage of bronze spoon manufacture. Centerline cracking is also caused by ${\alpha}$ phase segregation, accompanied by forged overlapping along the longitudinal direction of the spoons. A vertical stripe with cracks along the centerline of the spoon's width is formed by folding in the wrought process. The overlapping area causes crack propagation with severe corrosion on the spoon surfaces over a period of a thousand years. The failure mechanisms of ancient bronze spoons may be similar to that of modern spoons, and the estimation of the failure mechanisms of ancient spoons can be appropriate to determine failure causes for such modern spoons.

Seismic performance of RC short columns with light transverse reinforcement

  • Tran, Cao Thanh Ngoc;Li, Bing
    • Structural Engineering and Mechanics
    • /
    • v.67 no.1
    • /
    • pp.93-104
    • /
    • 2018
  • The seismic behavior of reinforced concrete (RC) short columns with limited transverse reinforcement is investigated in this paper through an experimental program. The experimental program consists of four small-scale RC columns with an aspect ratio of 1.7, which are tested to the axial failure stage. The cracking patterns, hysteretic responses, strains in reinforcing bars, displacement decomposition and cumulative energy dissipation of the tested specimens are reported in detail in the paper. The effects of column axial load are investigated to determine how this variable might influence the performance of the short columns with limited transverse reinforcement. Brittle shear failure was observed in all tested specimens. Beneficial and detrimental effects on the shear strength and drift ratio at axial failure of the test specimens due to the column axial load are found in the experimental program, respectively.

Experimental Study on Behaviour of Composite Beams with Ribbed Slabs and Unreinforced Web Openings (리브형 슬래브를 갖는 유공합성보의 거동에 관한 실험적 연구)

  • 김창호;박종원;김희구;이창섭;박준용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.989-994
    • /
    • 2000
  • Nine tests to failure are performed on full-scale eight composite beams with unreinforced web opening having ribbed slabs with formed deck which are perpendicular to the steel section and one steel beam. The effects of slab width, reinforcing of stud, moving of rib, moment-shear ratio are studied. At the low M/V ratio, Vierendeel action around the high moment end of the opening is occurred and the large deflection across the opening and transverse cracking are occurred with increasing of applied load. As the M/V ratio increases, the relative deflection across the opening decreases. And at failure, full tensile strain are occurred at bottom T section of steel beam, and concrete crushes at the High Moment End of the opening. With narrow slabs, diagonal tension failure at the high moment end of the opening is occurred. And with wide slabs, rib punch-through failure is occurred near the high moment end of the opening. The implications for design are discussed.

Static Compressive Strength of Thick Unidirectional Carbon Fiber - Epoxy Laminate (두꺼운 일방향 탄소섬유-에폭시 적층판의 정적 압축 강도 연구)

  • Lee, J.;Soutis, C.;Gong, Chang-Deok
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.61-65
    • /
    • 2005
  • Existing test methods for thick-section specimens ( 4mm) have not provided precise compressive properties to date for the analysis and design of thick structure. A survey of the failure behaviour of such thick specimens revealed that the failure initiated at the top corner of the specimen and propagated down and across the width of the specimen as premature failure, not typically reported for thin compression specimens. In the current study, the premature failure was successfully avoided during compressive testing and the failure mode was quite similar regardless of increasing specimen thickness and specimen volume. Failure mode was similar regardless of increasing specimen thickness and specimen volume, i.e. brooming failure mode combined with longitudinal splitting, interlaminar cracking, fibre breakage and kinkband formation (fibre microbuckling). Nevertheless, average failure strengths of the specimens decreased with increasing specimen thicnkiness from 2mm to 8mm with the T800/924C system (36% strength reduction) and specimen volumes from scaling factor I to scaling factor 4 with the IM7/8552 system (46% strength reduction). It was revealed from the literature$^{11}$ that the thickness effect and scaling effect arc caused by manufacturing defects such as void content and fibre waviness.

  • PDF