• 제목/요약/키워드: coupling efficiency

검색결과 650건 처리시간 0.024초

First-principles studies on mechanical, electronic, magnetic and optical properties of new multiferroic members BiLaFe2O6 and Bi2FeMnO6: Originated from BiFeO3

  • Tuersun, Yisimayili;Rouzhahong, Yilimiranmu;Maimaiti, Maihemuti;Salamu, Abidiguli;Xiaerding, Fuerkaiti;Mamat, Mamatrishat;Jing, Qun
    • Current Applied Physics
    • /
    • 제18권12호
    • /
    • pp.1473-1479
    • /
    • 2018
  • Recently multiferroic materials have attract great interest for the applications on memorial, spintronic and magneto-electric sensor devices for their spontaneous magneto-electric coupling properties. Research and development of the various kinds of multiferroics are indispensable factor for a new generation multifunctional materials. In this research, mechanical, electronic, magnetic and nonlinear optical properties of La modified $BiLaFe_2O_6$ (BLFO) and Mn modified $Bi_2FeMnO_6$ (BFMO) were studied as new members of multiferroic $BiFeO_3$ (BFO) series by first-principles calculations, and compared with the pure BFO to discover the optimized properties. Our results show that BLFO and BFMO have good mechanical stability as revealed by elastic constants that satisfy the stability criteria. All these compounds exhibit anisotropic and ductile nature. The enhanced properties by La and Mn substitution, such as increased hardness, improved magnetism, decreased band gap and comparable second harmonic generation responses reveal that the new multiferroic members of BLFO and BFMO would get wider application than their BFO counterpart. Our study is expected to providing an appropriate mechanical reference data as guidance for engineering of high efficiency multifunctional devices with the BFO series.

The detection efficiency study of NaI(Tl) scintillation detector with the different numbers of SiPMs

  • Wang, Bao;Zhang, Xiongjie;Wang, Qingshan;Wang, Dongyang;Li, Dong;Xiahou, Mingdong;Zhou, Pengfei;Ye, Hao;Hu, Bin;Zhang, Lijiao
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2564-2571
    • /
    • 2022
  • SiPMs are generally coupled into whole columns in gamma energy spectrum measurement, but the relationship between the distribution of whole SiPM columns and the energy resolution of the measured energy spectra is rarely reported. In this work, ∅ 3 × 3 inch NaI scintillator is placed on an 8 × 8 SiPM array, and the energy resolution of the 137Cs peak at 662 keV corresponding to the γ-ray is selected as a reference. Each SiPM is switched to explore the influence of the number of SiPM arrays, distribution position, and reflective layer on the energy resolution of SiPMs. Results show that without coupling, the energy resolution is greatly improved when the number of SiPMs ranges from 4 to 32. However, after 32 slices (the area covered by SiPMs relative to the scintillator reaches 25.9%), the improvement in energy resolution and total pulse count is not obvious. In addition, the position of SiPMs relative to the scintillator does not exert much impact on the energy resolution. Results also indicate that by adding a reflective film (ESR), the energy resolution of the tested group increases by 10.38% on average. This work can provide a reference for the design and application of miniaturized SiPM gamma spectrometers.

전력변환장치 캐비넷에서의 내부발열 개선을 위한 열유동 분석 및 유통안전성 향상을 위한 진동특성 분석 (Theoretical Heat Flow Analysis and Vibration Characteristics During Transportation of PCS(Power Conversion System) for Reliability)

  • 주민정;서상욱;오재영;정현모;박종민
    • 한국포장학회지
    • /
    • 제28권2호
    • /
    • pp.143-149
    • /
    • 2022
  • PCS needs to freely switch AC and DC to connect the battery, external AC loads and renewable energy in both directions for energy efficiency. Whenever converting happens, power loss inevitably occurs. Minimization of the power loss to save electricity and convert it for usage is a very critical function in PCS. PCS plays an important role in the ESS(Energy Storage System) but the importance of stabilizing semiconductors on PCB(Printed Circuit Board) should be empathized with a risk of failure such as a fire explosion. In this study, the temperature variation inside PCS was reviewed by cooling fan on top of PCS, and the vibration characteristics of PCS were analyzed during truck transportation for reliability of the product. In most cases, a cooling fan is mounted to control the inner temperature at the upper part of the PCS and components generating the heat placed on the internal aluminum cooling plate to apply the primary cooling and the secondary cooling system with inlet fans for the external air. Results of CFD showed slightly lack of circulating capacity but simulated temperatures were durable for components. The resonance points of PCS were various due to the complexity of components. Although they were less than 40 Hz which mostly occurs breakage, it was analyzed that the vibration displacement in the resonance frequency band was very insufficient. As a result of random-vibration simulation, the lower part was analyzed as the stress-concentrated point but no breakage was shown. The steel sheet could be stable for now, but for long-term domestic transportation, structural coupling may occur due to accumulation of fatigue strength. After the test completed, output voltage of the product had lost so that extra packaging such as bubble wrap should be considered.

선박 회전축의 무선 센서 시스템의 전원 공급을 위한 회전식 정전용량-무선 전력 전송 시스템 (A Rotary Capacitive-Wireless Power Transfer System for Power Supply of a Wireless Sensor System on Marine Rotating Shaft)

  • 호앙 반 아이;이영철
    • 한국항행학회논문지
    • /
    • 제27권1호
    • /
    • pp.63-70
    • /
    • 2023
  • 본 연구는 선박 추진 축계의 무선 센서 시스템(WSS) 응용을 위한 용량성 무선 전력 전송(C-WPT) 시스템을 제시한다. 커플링 커패시터 양쪽의 단일 Q 팩터 및 회로에서 무효 전력제거를 위해 양면 LCLC 컨버터 및 변압기 토폴로지가샤프트에서 WSS용 회전식 C-WPT 시스템을 구동하도록 설계되었습니다. 170pF의 용량을 갖는 병렬 연결된 평행판 회전 커패시터가 설회전축의 C-WPT 시스템용으로 설계 및 구현된다. 실험 결과 C-WPT 시스템은 3mm 거리 및 1 MHz 작동 주파수에서 7.8 W 출력 전력으로 66.67 %의 전송 효율을 달성했다. 따라서 제작된 C-WPT 시스템은 회전축의 WSS에 전원을 공급할 수 있음을 증명하였다.

초임계이산화탄소를 이용한 플로레닐계 에폭사이드로부터 카보네이트 화합물의 합성 (Synthesis of a Fluorene Carbonate from Fluorenyl Epoxide Using Supercritical Carbon Dioxde)

  • 심윤수;심재진;나춘섭
    • 청정기술
    • /
    • 제16권4호
    • /
    • pp.239-244
    • /
    • 2010
  • 스파이로 구조의 플로렌 에폭사이드, 9,9'-Bis(4-oxiranylmethoxyphenyl) fluorine (2)를 4차 암모니늄 또는 인산염을 촉매를 사용하여 이산화탄소와 반응시켜 5각고리의 플로렌 카보네이트 화합물로 전환시켰다. 이 과정은 주요 온실가스의 하나인 초임계 조건의 이산화탄소를 C-1 재료로 쓰고 동시에 반응용매로 이용하는 청정반응의 한 예로 볼 수 있다. 4차염의 종류와 반응조건이 반응에 미치는 영향에 대해 조사한 결과, 촉매의 음이온의 종류, 알킬 치환기, 반응온도가 반응에 큰 영향을 미치는 것으로 나타났다. 브롬화 사부틸 암모늄 촉매 (2 mol%)를 쓰고 플로레닐 에폭사이드를 75.9 bar 압력의 이산화탄소를 393 K에서 반응시켰을 때 플로레닐 카보네이트를 92% 수율로 얻을 수 있었다.

Study of the longitudinal reinforcement in reinforced concrete-filled steel tube short column subjected to axial loading

  • Alifujiang Xiamuxi;Caijian Liu;Alipujiang Jierula
    • Steel and Composite Structures
    • /
    • 제47권6호
    • /
    • pp.709-728
    • /
    • 2023
  • Experimental and analytical studies were conducted to clarify the influencing mechanisms of the longitudinal reinforcement on performance of axially loaded Reinforced Concrete-Filled Steel Tube (R-CFST) short columns. The longitudinal reinforcement ratio was set as parameter, and 10 R-CFST specimens with five different ratios and three Concrete-Filled Steel Tube (CFST) specimens for comparison were prepared and tested. Based on the test results, the failure modes, load transfer responses, peak load, stiffness, yield to strength ratio, ductility, fracture toughness, composite efficiency and stress state of steel tube were theoretically analyzed. To further examine, analytical investigations were then performed, material model for concrete core was proposed and verified against the test, and thereafter 36 model specimens with four different wall-thickness of steel tube, coupling with nine reinforcement ratios, were simulated. Finally, considering the experimental and analytical results, the prediction equations for ultimate load bearing capacity of R-CFSTs were modified from the equations of CFSTs given in codes, and a new equation which embeds the effect of reinforcement was proposed, and equations were validated against experimental data. The results indicate that longitudinal reinforcement significantly impacts the behavior of R-CFST as steel tube does; the proposed analytical model is effective and reasonable; proper ratios of longitudinal reinforcement enable the R-CFSTs obtain better balance between the performance and the construction cost, and the range for the proper ratios is recommended between 1.0% and 3.0%, regardless of wall-thickness of steel tube; the proposed equation is recommended for more accurate and stable prediction of the strength of R-CFSTs.

Internal Dosimetry: State of the Art and Research Needed

  • Francois Paquet
    • Journal of Radiation Protection and Research
    • /
    • 제47권4호
    • /
    • pp.181-194
    • /
    • 2022
  • Internal dosimetry is a discipline which brings together a set of knowledge, tools and procedures for calculating the dose received after incorporation of radionuclides into the body. Several steps are necessary to calculate the committed effective dose (CED) for workers or members of the public. Each step uses the best available knowledge in the field of radionuclide biokinetics, energy deposition in organs and tissues, the efficiency of radiation to cause a stochastic effect, or in the contributions of individual organs and tissues to overall detriment from radiation. In all these fields, knowledge is abundant and supported by many works initiated several decades ago. That makes the CED a very robust quantity, representing exposure for reference persons in reference situation of exposure and to be used for optimization and assessment of compliance with dose limits. However, the CED suffers from certain limitations, accepted by the International Commission on Radiological Protection (ICRP) for reasons of simplification. Some of its limitations deserve to be overcome and the ICRP is continuously working on this. Beyond the efforts to make the CED an even more reliable and precise tool, there is an increasing demand for personalized dosimetry, particularly in the medical field. To respond to this demand, currently available tools in dosimetry can be adjusted. However, this would require coupling these efforts with a better assessment of the individual risk, which would then have to consider the physiology of the persons concerned but also their lifestyle and medical history. Dosimetry and risk assessment are closely linked and can only be developed in parallel. This paper presents the state of the art of internal dosimetry knowledge and the limitations to be overcome both to make the CED more precise and to develop other dosimetric quantities, which would make it possible to better approximate the individual dose.

Seismic behavior of deep-sea pipeline after global buckling under active control

  • Jianshuo Wang;Tinghao Meng;Zechao Zhang;Zhihua Chen;Hongbo Liu
    • Earthquakes and Structures
    • /
    • 제26권4호
    • /
    • pp.261-267
    • /
    • 2024
  • With the increase in the exploitation depth of offshore oil and gas, it is possible to control the global buckling of deep-sea pipelines by the snake lay method. Previous studies mainly focused on the analysis of critical buckling force and critical temperature of pipelines under the snake-like laying method, and pipelines often suffer structural failure due to seismic disasters during operation. Therefore, seismic action is a necessary factor in the design and analysis of submarine pipelines. In this paper, the seismic action of steel pipes in the operation stage after global buckling has occurred under the active control method is analyzed. Firstly, we have established a simplified finite element model for the entire process cycle and found that this modeling method is accurate and efficient, solving the problem of difficult convergence of seismic wave and soil coupling in previous solid analysis, and improving the efficiency of calculations. Secondly, through parameter analysis, it was found that under seismic action, the pipe diameter mainly affects the stress amplitude of the pipeline. When the pipe wall thickness increases from 0.05 m to 0.09 m, the critical buckling force increases by 150%, and the maximum axial stress decreases by 56%. In the pipe soil interaction, the greater the soil viscosity, the greater the pipe soil interaction force, the greater the soil constraint on the pipeline, and the safer the pipeline. Finally, the pipeline failure determination formula was obtained through dimensionless analysis and verified, and it was found that the formula was accurate.

효소고정화 방법에 따른 콜레스테롤 검출용 바이오센서의 전류 감응도 분석 (Analysis of Amperometric Response to Cholesterol according to Enzyme-Immobilization Methods)

  • 지정윤;김미라
    • 동아시아식생활학회지
    • /
    • 제21권5호
    • /
    • pp.731-738
    • /
    • 2011
  • 콜레스테롤의 신속하고 정확한 새로운 분석방법을 모색하기 위하여 본 연구에서는 전기적 전도성이 우수한 MWCNT를 이용하여 전극을 제작하였고, 여러 가지 효소고정화 방법을 통해 전기화학적 감응도 분석을 실시하였다. MWCNT의 전도성을 향상시키기 위해 아민기를 도입한 MWCNT-$NH_2$를 제조하였고, MWCNT-$NH_2$/GCE에 PB를 점착하여 작업전극을 제조하였다. 제조한 작업전극은 0.5~500 ${\mu}M$ $H_2O_2$ 농도 범위에서 농도가 증가함에 따라 전류가 비례적으로 증가하였고, 검출한계는 0.1 ${\mu}M$로 나타나 전극이 높은 감도를 가지고 있음을 확인하였다. 또한 콜레스테롤 검출을 위해 적합한 효소 반응기를 제작하기 위해 담체인 aminopropyl glass beads, CNBr-activated sepharose, Na-alginate, toyopearl beads에 cholesterol oxidase를 고정화시켜 바이오센서의 콜레스테롤 표준용액에 대한 감응도를 측정한 결과, aminopropyl glass beads과 CNBr-activated sepharose는 1~100 ${\mu}M$ 범위에서 선형관계를 보였으며, Na-alginate는 5~50 ${\mu}M$의 범위에서, toyopearl beads는 1~50 ${\mu}M$ 범위에서 선형관계를 나타내었다. 검출한계는 제작된 효소반응기 모두 1 ${\mu}M$로 나타나 콜레스테롤에 대한 높은 검출력을 보여주었으나, 특히 CNBr-activated sepharose와 Na-alginate를 이용한 효소반응기가 높은 coupling efficiency와 감응도를 보여 콜레스테롤 검출을 위한 본 바이오 센서 시스템에 적합한 것으로 나타났다.

전기집진장치의 코로나 전류 발생 전극 제작에 따른 추타력 비교에 관한 연구 (The Study of Comparison on Rapping Force on Generation of Corona Discharge Electrode of Electrostatic Precipitator)

  • 이강욱;박정호;장성호;임우택;서정민
    • 한국환경과학회지
    • /
    • 제26권2호
    • /
    • pp.231-238
    • /
    • 2017
  • Rapid industrial development has led to a serious problem of pollution in the industrial sector. With the increasing social need for environmental protection, research on air pollution prevention equipment for reducing pollutants in industrial processes is actively being undertaken. The deterioration of existent, installed facilities, their increased emission rates, and the strengthening of the effluent quality standards make complying with permissible emission standards difficult. In fact, installing new electric precipitators or complementing existent facilities is inevitable. The expansion and complementation of the installed electrical precipitators have led to improvements in dust collection efficiency, shorter working times, and lower costs. Because of its easy installation and simple manufacturing process, the production method with the discharge electrode of an electric precipitator is widely used. The following conclusions were reached by classifying discharge electrodes into four types based on the production method and mutually comparing them by their dust collection efficiency. None of the four types used in this study were damaged by impact. However, we were able to confirm some strain from the compression sites of both type A and type B. Both type B and type C are expected to have greater dust collection efficiencies than the other models due to their large vibration transmissibility. Moreover, the high vibrational energy is expected to cause rapping damage during its operation. Particularly, in the case of type B, some of the strain was found at the end of the compression site. The coupling schemes of both type C and type D are out of vibration transmissibility. On the other hand, the ability to maintain straightness and solidity of the side is regarded as outstanding and stable. Type D has outstanding on-site workability, considering the presence of locking, structural stability, and work conditions. From these experiments, we determined that type C is the most ideal connection method of discharge electrode, considering its construction period of renovation. Type C is inferior to type D with regard to on-site workability. However, type C has outstanding dedusting transmission with regard to the straightness, solidity maintenance, and vibration of shearing stress.