• 제목/요약/키워드: coupled walls

검색결과 106건 처리시간 0.021초

병렬 전단벽의 커플링 정도에 관한 연구 (The Study on Degree of Coupling in Coupled Shear Wall System)

  • 박완신;윤현도;황선경;김선우;한민기;이원석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.135-138
    • /
    • 2005
  • Since a ductile coupled shear wall system is the primary seismic load resisting systems of many structures, a coupling beams of these system must exhibit excellent ductility and energy absorption capacity. In this paper, the seismic response of coupled shear wall system is discussed. It includes that the evaluation of the degree of coupling between the shear walls and the coupling beams. It is demonstrated through a review of experimental investigations of coupling beam behavior that often the coupling beam ductility demand exceeds the expected available ductility. As a result, it is possible that coupled shear wall system will not behave as desired in the course of a significant seismic event. Limits to the allowable degree of coupling are proposed as a remedy to this apparent deficiency.

  • PDF

다양한 열전달 경계조건을 고려한 고속 저어널 베어링의 난류 열유체 윤활 연구 (A Study on Thermohydrodynamic Turbulent Lubrication of High Speed Journal Bearing Considering Various Thermal Conditions on Walls)

  • 전상명;장시열
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제31회 춘계학술대회
    • /
    • pp.93-98
    • /
    • 2000
  • Turbulence on the journal bearing operation is examined. And the thermal variability is studied for isothermal, convective and adiabatic conditions on the walls within some degree of journal misalignment. An efficient algorithm for the solution of the coupled turbulent Reynolds and energy equations is used to examine the effects of the various factors. The calculation data of turbulent analysis are compared with the ones of laminar analysis. Heat convection is found to play but a small role in determining friction and load. The friction distribution patterns through inside a journal bearing now appear different with high values at the front part of the bearing due to the high speed and low temperature, and a sudden decrease past the pressure maximum.

  • PDF

열전달 경계조건을 고려한 고속 저어널 베어링의 난류 열유체 윤활 연구 (A Study on Thermohydrodynamic Turbulent Lubrication of High Speed Journal Bearing Considering Thermal Conditions on Walls)

  • 전상명;장시열
    • Tribology and Lubricants
    • /
    • 제16권3호
    • /
    • pp.208-217
    • /
    • 2000
  • Turbulence in journal bearing operation is examined and the thermal variability is studied for isothermal, convective and adiabatic conditions on the walls within some degree of journal misalignment. An efficient algorithm for the solution of the coupled turbulent Reynolds and energy equations is used to examine the effects of the various factors. The calculation data of turbulent analysis are compared with those of laminar analysis. Heat convection is found to play but a small role in determining friction and load. The friction distribution patterns through the journal bearing are now different with high values at the upstream region of the bearing due to the high speed and low temperature, and a sudden decrease past the pressure maximum.

주기하중을 받는 세장한 이중강판합성벽의 비선형해석 (Nonlinear Analysis of Slender Double Skin Composite Walls Subjected to Cyclic Loading)

  • 엄태성;박홍근
    • 한국강구조학회 논문집
    • /
    • 제20권4호
    • /
    • pp.505-517
    • /
    • 2008
  • 휨지배 거동을 나타내는 세장한 이중강판합성벽의 비탄성 거동을 예측하기 위하여 비선형 수치해석 모델이 연구되었다. 수치해석의 편리를 위하여, 제안된 모델은 비교적 단순한 모델을 가지고 비탄성 거동을 근사적으로 예측할 수 있는 거시적 모델로 개발되었다. 휨지배 거동을 나타내는 벽체에 대해서는 다중평행요소 모델이 사용되었으며, 깊은 연결보의 전단거동을 위하여 X형 대각요소 모델이 사용되었다. 각 요소의 주기거동을 예측하기 위하여 콘크리트 및 강판 요소에 대한 간략화된 일축의 주기모델을 제안하였다. 제안된 해석모델은 1자형 및 T형 단일벽과 병렬벽에 적용하였으며, 그 결과는 기존의 실험결과와 비교되었다.

Bearing Strength of Hybrid Coupled Shear Wall Connections

  • Park Wan-Shin;Yun Hyun-Do
    • 콘크리트학회논문집
    • /
    • 제17권6호
    • /
    • pp.1065-1074
    • /
    • 2005
  • Due to lack of information, current design methods to calculate bearing strength of connections are tacit about cases in which hybrid coupled walls have connection details of stud bolts and horizontal ties. In this study, analytical study was carried out to develop model for calculating the connections strength of embedded steel section. The bearing stress at failure in the concrete below the embedded steel coupling beam section is related to the concrete compressive strength and the ratio of the width of the embedded steel coupling beam section to the thickness of the shear walls. Experiments were carried out to determine the factors influencing the bearing strength of the connection between steel coupling beam and reinforced concrete shear wall. The test variables included the reinforcement details that confer a ductile behavior in connection between steel coupling beam and shear wall, i. e., the auxiliary stud bolts attached to the steel beam flanges and the transverse ties at the top and the bottom steel beam flanges. In addition, additional test were conducted to verify the strength equations of the connection between steel coupling beam and reinforced concrete shear wall. The results of the proposed equations in this study are in good agreement with both our test results and other test data from the literature.

접합부 상세에 따른 철골 커플링 보-벽체 접합부의 지압강도 (Bearing Strength of Steel Coupling Beams-Wall Connections depending upon Joint Details)

  • 박완신;윤현도;한병찬;황선경;양일승;김선우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.113-116
    • /
    • 2004
  • No specific guidelines are for computing the shear strength of steel coupling beam connections embedded in the reinforced concrete shear wall. In this paper, a theoretical study of the strength of hybrid coupled shear wall connections is achieved. The bearing stress at failure in the concrete below the steel coupling beam section is related to the concrete compressive strength and the ratio of the width of the steel coupling beam section to the thickness of the hybrid coupled shear wall. To revise factor affecting shear transfer strength across connections between coupled shear walls and steel coupling beam, experimental studies are achieved. The main test variables were auxiliary details of stud bolts. In this studies, these proposed equations are shown to be in good agreement with the test results reported in the paper and with other test data in the literature.

  • PDF

HYDROELASTIC VIBRATION ANALYSIS OF TWO FLEXIBLE RECTANGULAR PLATES PARTIALLY COUPLED WITH A LIQUID

  • Jeong, Kyeong-Hoon;Kim, Jong-Wook
    • Nuclear Engineering and Technology
    • /
    • 제41권3호
    • /
    • pp.335-346
    • /
    • 2009
  • This paper deals with a hydroelastic vibration analysis of two rectangular plates partially coupled with a liquid, which is bounded by two plates and two rigid side walls. The wet displacement of each plate is assumed to be a combination of the modal functions of a dry uniform beam with a clamped boundary condition. As the liquid is assumed to be an ideal liquid, the displacement potential satisfying the Laplace equation is determined so that the liquid boundary conditions can meet the requirements at the rigid surfaces and the free liquid surface. The wet dynamic modal functions of each plate are expanded by using the finite Fourier transform to obtain an appropriate form of the compatibility requirement along the contacting surfaces between the plates and the liquid. The liquid-coupled natural frequencies of the plates are derived by using the Rayleigh-Ritz method. Finite element analyses using commercial software are carried out to verify the proposed theory. It is observed that the theoretical method agrees excellently with the three-dimensional finite element analyses results. The effects of the liquid depth and the liquid thickness on the normalized natural frequencies are investigated to identify the dynamic characteristics of the liquid coupled system.

Damage rate assessment of cantilever RC walls with backfill soil using coupled Lagrangian-Eulerian simulation

  • Javad Tahamtan;Majid Gholhaki;Iman Najjarbashi;Abdullah Hossaini;Hamid Pirmoghan
    • Geomechanics and Engineering
    • /
    • 제36권3호
    • /
    • pp.231-245
    • /
    • 2024
  • In recent decades, the protection and vulnerability of civil structures under explosion loads became a critical issue in terms of security, which may cause loss of lives and structural damage. Concrete retaining walls also restrict soils and slopes from displacements; meanwhile, intensive temporary loading may cause massive damage. In the current study, the modified Johnson-Holmquist (also known as J-H2) material model is implemented for concrete materials to model damages into the ABAQUS through user-subroutines to predict the blasting-induced concrete damages and volume strains. For this purpose, a 3D finite-element model of the concrete retaining wall was conducted in coupled Eulerian-Lagrangian simulation. Subsequently, a blast load equal to 500 kg of TNT was considered in three different positions due to UFC 3-340-02. Influences of the critical parameters in smooth blastings, such as distance from a free face, position, and effective blasting time, on concrete damage rate and destroy patterns, are explored. According to the simulation results, the concrete penetration pattern at the same distance is significantly influenced by the density of the progress environment. The result reveals that the progress of waves and the intensity of damages in free-air blasting is entirely different from those that progress in a dense surrounding atmosphere such as soil. Half-damaged elements in air blasts are more than those of embedded explosions, but dense environments such as soil impose much more pressure in a limited zone and cause more destruction in retaining walls.

Structural Shear Wall Systems with Metal Energy Dissipation Mechanism

  • Li, Guoqiang;Sun, Feifei;Pang, Mengde;Liu, Wenyang;Wang, Haijiang
    • 국제초고층학회논문집
    • /
    • 제5권3호
    • /
    • pp.195-203
    • /
    • 2016
  • Shear wall structures have been widely used in high-rise buildings during the past decades, mainly due to their good overall performance, large lateral stiffness, and high load-carrying capacity. However, traditional reinforced concrete wall structures are prone to brittle failure under seismic actions. In order to improve the seismic behavior of traditional shear walls, this paper presents three different metal energy-dissipation shear wall systems, including coupled shear wall with energy-dissipating steel link beams, frame with buckling-restrained steel plate shear wall structure, and coupled shear wall with buckling-restrained steel plate shear wall. Constructional details, experimental studies, and calculation analyses are also introduced in this paper.

철근콘크리트 벽체의 비선형 해석을 위한 거시 모델 (Macro Model for Nonlinear Analysis of Reinforced Concrete Walls)

  • 김동관;엄태성;임영주;이한선;박홍근
    • 콘크리트학회논문집
    • /
    • 제23권5호
    • /
    • pp.569-579
    • /
    • 2011
  • 주기하중을 받는 철근콘크리트 벽체는 형상비, 배근상세, 재하 조건 등에 따라 복잡한 비탄성 거동을 보인다. 이 연구에서는 벽체의 휨-압축 거동과 전단거동을 간편하게 고려할 수 있는 거시 요소를 이용한 비선형 해석 방법을 개발하였다. 철근콘크리트 벽체의 휨-압축 거동 및 전단거동은 각각 길이 방향 및 대각 방향 1축 요소로 이상화된다. 1축 요소는 콘크리트와 철근으로 구성되고, 비선형 재료 모델로서 1축 상태에서 반복하중을 받는 콘크리트와 철근의 주기거동 모델을 사용한다. 검증을 위하여 제안된 방법을 사용하여 주기하중을 받는 철근콘크리트 단일벽 및 병렬벽의 비선형 해석을 수행하였다. 그 결과 제안된 방법은 휨-압축 거동이 지배적인 세장한 벽체와 전단거동이 지배적인 낮은 벽체의 주기거동을 정확하게 예측하였다. 제안된 거시 해석 모델은 모델링이 편리하고 수치해석의 안정성이 우수하므로, 전단벽 및 코어벽이 사용된 건물의 비선형 해석을 위한 범용 프로그램으로 개발이 용이할 것으로 판단된다.