개구부로 연결된 3중 커플룸의 음향특성 (Acoustic Properties of Three-room Coupled System by Connected Two Apertures)

  • 나혜중;임병덕
    • 한국소음진동공학회논문집
    • /
    • 제26권3호
    • /
    • pp.340-349
    • /
    • 2016
  • A coupled room system consists of adjacent rooms and apertures where the sound energy is exchanged between the two rooms. Acoustically, a coupled room system shows a non-exponential decay profile. Most of the related researches have been to analyze the acoustic properties of two-room coupled system so far whereas three-room coupled system were seldom studied. In this regard, this paper aims to analyse the distribution of sound pressure level, sound decay curve of three-room coupled system and sound energy flow between them by using the acoustic diffusion model and to further verify them through experiments. Firstly, the sound pressure level distribution and mean sound pressure level in the steady-state condition are analyzed at various frequencies and source locations. Good agreements are observed in both experiments and analysis results. Secondly, two double slope effect quantifiers of sound attenuation, LDT/EDT and LDT/T10 are compared at various frequencies and for different source locations. The result indicates that LDT/T10, less affected by the early reflection patterns than LDT/EDT, is more suitable to the analysis and experiments of a multi-slope sound decay curve. Lastly, the sound energy flow in each room is analyzed based on the acoustic diffusion model. After the early decay stage, the sound energy is observed to flow from the room with a long reverberation time to the room with a short one.

정상상태조건에서의 개구부로 연결된 커플룸의 음향 특성 (Room Acoustic Properties of Coupled Rooms Connected by an Aperture in the Steady State Condition)

  • 나혜중;임병덕
    • 한국소음진동공학회논문집
    • /
    • 제26권3호
    • /
    • pp.315-322
    • /
    • 2016
  • Room acoustic properties of coupled rooms connected by an aperture has been analyzed using statistical acoustic model based on the diffused sound field assumption, which has limitation in dealing with the parameters such an room geometries and non uniform absorptivity of the boundary surfaces. In order to overcome these difficulties the acoustic diffusion model has been introduced, by which distribution of the acoustic energy density can be analyzed for various shapes and wall absorptivity. In this study acoustic properties of coupled rooms connected by an aperture(e.g. door) is analyzed using acoustic diffusion equation, which is solved numerically. The mean energy densities of two rooms obtained by the diffusion model are compared with those from the statistical model. The results show good agreement for various coupling aperture sizes and absorption coefficients. For a limiting case when the partition wall is substituted by an aperture and the two rooms eventually forms a single room, results of coupled room analysis using diffusion model show good agreement with those of a single room.

음향적으로 결합된 공간의 잔향특성변화에 관한 연구 (A Study on the Reverberation Characteristics of Coupled Spaces)

  • 정대업;김지영;최영지
    • 한국공간구조학회논문집
    • /
    • 제8권3호
    • /
    • pp.53-63
    • /
    • 2008
  • 본 연구는 개구부를 통해 음향적으로 결합된 공간에서의 잔향특성변화를 축소모형을 이용하여 살펴보았다. 대상공간의 음향적 결합은 정방형의 개구부를 통하여 이루어졌으며, 개구부의 크기, 부실의 흡음력 및 위치를 변화시켜가며 실의 음향특성변화를 측정 분석하였다. 연구결과 동일한 체적을 가진 부실을 통해 주실의 음향특성을 조절하는 경우 부실의 흡음력을 주실보다 현저하게 낮게 하는 것이 넓은 범위의 음향조절이 가능하며, 음향특성을 단계적으로 조절하고자 하는 경우 주실보다 높은 흡음력을 가진 부실을 이용하는 것이 효과적인 것으로 나타났다. 잔향부실의 경우 음원 측에 위치시키는 것이 효과적이며, 개구율이 6.25%이상일 때부터 주실의 음장특성에 중요한 영향을 미치는 것으로 분석되었다. 그러나 개구율이 25%이상으로 증가되면 개구율 증가에 따른 주실의 유의적인 음향특성변화는 더 이상 나타나지 않았다. 흡음부실이 결합되는 경우 음원으로부터 멀리 위치시키는 것이 효과적이었으며, 개구율 3.13%이상일 때부터 주실의 음장특성변화가 가능하였다.

  • PDF

음향적으로 결합된 공간의 주관적 잔향감에 관한 연구 (A Subjective Study on the Reverberation Characteristics of Coupled Spaces)

  • 정대업;최영지
    • 한국공간구조학회논문집
    • /
    • 제8권3호
    • /
    • pp.65-73
    • /
    • 2008
  • 본 연구에서는 음향적으로 결합된 공간에서 개구부의 크기변화에 따른 주관적 잔향감의 평가를 청취실험을 통해 실시하고 주관적 잔향감을 예측할 수 있는 새로운 물리적 지표를 제시하고자 하였다. 대상공간의 물리적 음향특성은 물론 주관적 음향평가를 위하여 1/10 스케일의 모형을 제작하여 실험에 사용하였다. 주관적 잔향감평가를 위해 바이노럴 임펄스 리스펀스(binaural impulse response)를 더미헤드(dummy head)를 이용해 녹음하여 가청화작업(auralization)을 거쳐 청취실험에 음원으로 제시하였다. 청취실험결과, 주실이 흡음력이 낮은 잔향부실과 음향적으로 결합할 경우 개구율이 12.5%(주실면적대비 1.97%)일 때 주관적 잔향감이 가장 큰 것으로 나타났으며 개구율이 25%(주실면적대비 3.94%)이상일 때 주관적 잔향감이 감소하는 것으로 나타났다 주실이 흡음력이 높은 흡음부실과 음향적으로 결합할 경우 개구율이 $0%{\sim}6.25%$까지(주실면적대비 $0%{\sim}0.99%$)는 주관적 잔향감이 변화하지 않다가 개구율이 12.5%에서부터 점차적으로 감소하는 것으로 나타났다. 이중감쇠현상을 나타내는 물리적 지표 T30/T15는 개구율의 변화에 따른 주관적 잔향감과 상관도가 거의 없는 것으로 나타났으며 저자들이 제시한 새로운 지표 T30/Tbp이 주관적 잔향감과 높은 상관도를 보였다. 또한 개구율 변화에 따른 이중감쇠현상은 초기나 중기감쇠부분에서보다 후기감쇠부분에서 에너지가 현저하게 증가하는 것으로 나타나 T30/T15에 비해 LDT/EDT나 T3/T1가 주관적 잔향감과의 상관성이 높은 것으로 나타났다.

  • PDF

A Prediction of the Indoor Air Movement and Contaminant Concentration in a Multi-Room Condition

  • Song, Doo-Sam;Kang, Ki-Nam;Park, Dong-Ryul
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권3호
    • /
    • pp.137-146
    • /
    • 2007
  • CFD simulation is a very useful tool to predict the concentration of contaminant generated from the building materials in a single room. However, there is a limitation on analyzing air movement and contaminant concentration in a multi-room when the door of each room is closed. In this study, network based simulation was coupled with contaminant simulation for the multi-room condition, using an network simulation tool 'ESP-r'. The coupled simulation was first validated with experimental measurements which performed to define the characteristics of the analyzed space prior to the simulation, and indoor air flow and contaminant concentration between rooms were then analyzed when the door of each room was open and closed in the case of natural and forced ventilation.

생물안전밀폐시설에서 Multizone과 CFD 연동해석에 의한 실내기류 및 Influenza A 오염농도해석 (Applications of a Coupled Multizone and CFD Simulation to Validate Airflow and Influenza A Contaminant Dispersion in Biosafety Laboratory)

  • 황지현;홍진관
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.588-593
    • /
    • 2014
  • To maintain a negative pressure, the supply, exhaust airvolume are adjusted by setting volume damper and the infiltration through leakage area of the door between rooms in biosafety laboratory. Multizone simulation is useful way to predict room pressure, supply and exhaust air volume. But in a particular room, local change such as airflow and contaminants concentration distribution can not be evaluated unfortunately. Through this study, a coupled multizone and CFD simulation was performed, indoor air flow and local contaminants concentration distribution in a particular room of BSL lab are predicted. The results show that all zones of BSL lab are well ventilated by unidirectional flow without local stagnation. In addition, in case that unexpected biohazard is occured in BSL lab, multizone simulation results about the spread of pollutants along movement of the occupant also show that contaminants concentration is removing totally without the spread of the outside. In conclusion, a coupled multizone and CFD simulation can be applied to interpret differential pressure in room and local change of physical quantity in a particular room such as airflow and Influenza A contaminants concentration distribution. This simulation method is useful to enhance the reliability and accuracy of biosafety laboratory design.

양방향 설정온도 제어에 따른 지중연계 히트펌프 시스템의 에너지 절감량 평가 연구 (Two Way Set Temperature Control Impact Study on Ground Coupled Heat Pump System Energy Saving)

  • 강은철;이의준;민경천
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권2호
    • /
    • pp.7-12
    • /
    • 2014
  • Government has recently restricted heating and cooling set temperatures for the commercial and public buildings due to increasing national energy consumption. The goal of this paper is to visualize a future two way indoor set temperature control impact on building energy consumption by using TRNSYS simulation modeling. The building was modelled based on the twin test cell with the same dimension. Air source ground coupled heat pump performance data has been used for modeling by TRNSYS 17. Daejeon weather data has been used from Korea Solar Energy Society. The heating set temperature in the reference room is $24^{\circ}C$ as well as the target room set temperature are $23^{\circ}C$, $22^{\circ}C$, $21^{\circ}C$ and $20^{\circ}C$. The cooling set temperature of the reference room is also $24^{\circ}C$ as well as the target room set temperature of $25^{\circ}C$, $26^{\circ}C$, $27^{\circ}C$ and $28^{\circ}C$. For the air source heat pump system, heating season energy consumption is $35.52kWh/m^2y$ in the reference room. But the heating energy consumption in the target room is reduced to 7.5% whenever the set temperature decreased every $1^{\circ}C$. The cooling energy consumption in the reference room is $4.57kWh/m^2y$. On the other hand, the energy consumption in the target room is reduced to 22% whenever the set temperature increased every $1^{\circ}C$ by two way controller. For the geothermal heat pump system, heating energy consumption in the reference room is reduced to 20.7%. The target room heating energy consumption is reduced to 32.6% when the set temperature is $22^{\circ}C$. The energy consumption in the target room is reduced to 59.5% when the set temperature is $26^{\circ}C$.

실화재실험을 통한 상수도 직결형 스프링클러시스템의 성능에 관한 연구 (A Study on the Performance of a Sprinkler System with Direct-Coupled Waterworks by Full-Scale Fire Test)

  • 정종진;남동군;임우섭
    • 한국화재소방학회논문지
    • /
    • 제25권6호
    • /
    • pp.39-43
    • /
    • 2011
  • 본 연구에서는 상수도 직결형 스프링클러 시스템의 성능을 평가하기 위하여 실물 주택을 대상으로 화재 실험을 수행하였다. 실물 주택의 크기는 $56m^2$이며 거실, 주방, 방으로 이루어져 있으며, 화재는 대두유가 과열되어 자연발화가 발생하여 일어나게 하였다. 상수도 직결형 스프링클러시스템의 성능을 확인하기 위하여 주방에 스프링클러시스템을 설치하였다. 실험결과 주방에서의 발화로 시작된 화재는 주방천장까지 확대 되었으나 스프링클러가 동작하면서 화재는 진압되었다. 스프링클러가 동작할 때의 상수도 압력은 0.28 MPa이었으며 이 결과로서 일반 주택의 상수도압력으로도 소화가 가능함을 확인할 수 있었다.

Clean Room 위험성 평가에 따른 안전성 확보에 관한 연구 (A Study on Safety by Risk Assessment of Clean Room)

  • 송윤석;윤명오;현성호;이창우;윤여송;김성민
    • 한국화재소방학회논문지
    • /
    • 제18권4호
    • /
    • pp.78-85
    • /
    • 2004
  • 본 연구에서 Clean Room 재해사례를 분석하였고, Factory Mutual Property Loss Prevention Data Sheets(FM), Industrial Risk Insurers(IRI), NFPA Code 등의 Clean Room 설계 주요 방화기준에 대하여 비교 분석을 하였다. 그리고 화재시뮬레이션을 통한 위험성 평가를 통해서 화재 시 공조설비의 작동으로 인한 연기산란 현상으로 Clean Room 내의 피해규모가 상상을 초월하는 결과를 얻을 수 있었으며, 또한 스프링클러설비의 작동으로 열온도가 더 낮아지고, 연기의 확산속도를 더 줄여줄 수 있는 것으로 분석되었다. 따라서, Clean Room내의 화재 시 화재감지기에 의해 공조설비를 정지시키고, 스프링클러설비를 설치하는 것이 안전성을 확보하는데 중요한 요소임을 유추하였다. 그러므로 본 연구에서 Clean Room 에 대한 안전성을 확보하는데 기여하고자 한다.

고속열차 중련운전 설계에 관한 연구 (The design concept of the multi-coupled operation for high speed train)

  • 최권희;장대성;정병호;이병석;김국진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.877-882
    • /
    • 2005
  • The definition of multi-coupled operation is that coupled two trainsets is able to be operated one trainset identically. That is to say, the one driver, coupled two trainsets can operate the traction and braking system, control vehicle doors, phanto-graph, HVAC and passenger room lighting system etc, such as one trainset controlling. This study will provide high speed train design engineer with introducing multi-coupled operation system electrically and presentation automatic complex coupler mechanism, and then this paper will be applied to design next generation high speed train system such as Jun-la/Ho-nam line