• Title/Summary/Keyword: counter current distribution

Search Result 56, Processing Time 0.024 seconds

Development of Oceanic General Circulation Model for Climate Change Prediction (기후변화예측을 위한 해양대순환모형의 개발)

  • Ahn, Joong-Bae;Lee, Hyo-Shin
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.3 no.1
    • /
    • pp.16-24
    • /
    • 1998
  • In this study, Ocean General Circulation Model (OGCM) has been developed as a counterpart of Atmospheric General Circulation (AGCM) for the study of coupled ocean-atmosphere climate system. The oceanic responses to given atmospheric boundary conditions have been investigated using the OGCM. In an integration carried out over 100 simulated years with climatological monthly mean data (EXP 1), most parts of the model reached a quasi-equilibrium climate reproducing many of the observed large-scale oceanic features remarkably well. Some observed narrow currents, however, such as North Equatorial Counter Current, were inevitably distorted due to the model's relatively coarse resolution. The seasonal changes in sea ice cover over the southern oceans around Antarctica were also simulated. In an experiment (EXP 2) under boundary condition of 10-year monthly data (1982-1991) from NCEP/NCAR Reanalysis Project model properly reproduced major oceanic changes during the period, including El Ni$\tilde{n}$os of 1982-1983 and 1986-87. During the ENSO periods, the experiment showed eastward expansion of warm surface waters and a negative vertical velocity anomalies along' the equator in response to expansion of westerly current velocity anomalies as westerly wind anomalies propagated eastward. Simulated anomalous distribution and the time behavior in response to El Ni$\tilde{n}$o events is consistent with that of the observations. These experiments showed that the model has an ability to reproduce major mean and anomalous oceanic features and can be effectively used for the study of ocean-atmosphere coupling system.

  • PDF

Study for Seperation Process of Copper from the Low-grade Copper Ore by Hydrometallrugical Process (저품위 동광으로부터 습식제련공정에 의한 구리의 분리 공정 연구)

  • Shin, Dong Ju;Joo, Sung-Ho;Lee, Dongseok;Jeon, Ho-Seok;Shin, Shun Myung
    • Resources Recycling
    • /
    • v.30 no.5
    • /
    • pp.57-66
    • /
    • 2021
  • In this study, we attempted to separate and recover Cu from low-grade copper ore by a hydrometallurgical process. The leaching sample obtained after crushing and sieving by 0.355 mm of low-grade copper ore contained 1.5% Cu, 4.7% Fe, 1.0% Mn, and 0.3% Zn. The Cu in the oxide ore was very well leached into sulfuric acid and 97% Cu leaching efficiency was achieved at 80℃ and 3 M sulfuric acid (H2SO4). From the leaching solution, Cu was separated by solvent extraction from Fe, Mn, and Zn using LIX984N. The separation tendency between Cu and other metals was confirmed through the distribution ratio and separation factor. By plotting the McCabe-Thiele Diagram, the optimum condition for recovering Cu is 5 vol.% LIX984N, 2-stage counter-current solvent extraction, and an O/A ratio of 0.5. Using this method, 99% of the Cu was extracted and a CuSO4 solution was finally obtained that contained 1.6 g/L Cu after the stripping process using 2 M H2SO4.

Proposals for Revising the Occupational Exposure Limits for Aluminum in Korea (국내 알루미늄 노출실태 및 노출기준 개정 제안)

  • Seung Won Kim;Young Gyu Phee;Yong-Joon Baek;Taejin Chung;Hye-Sil Lee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.85-97
    • /
    • 2024
  • Objectives: This study was intended to investigate the revision status of the occupational exposure standards for aluminum at home and abroad; to investigate worker exposure at domestic aluminum manufacturing and handling workplaces; to conduct social and economic evaluation for the revision of domestic aluminum exposure limits. Methods: We investigated the current status of occupational exposure limits for aluminum at home and abroad, and analyzed supporting data. An exposure survey was conducted targeting domestic aluminum manufacturing and handling workplaces. Based on these, revised aluminum occupational exposure limits were proposed. Results: The major aluminum exposure limits at home and abroad show a notable difference. The toxicity of aluminum, which was revealed through animal experiments and epidemiological investigations. The average concentration of aluminum in the air at 12 workplaces was 0.016 mg/m3, and the maximum was 0.0776 mg/m3. When total dust and respiratory dust were measured side by side and simultaneously for the same process, 12.1% of the total mass concentration of aluminum dust was respiratory dust. As a result of measuring and comparing the size distribution of dust with an optical particle counter in real time, 48.1% of the total dust in the form of welding fume and pyro-powder was respiratory dust. Based on the literature review and workplace survey, three proposals for changing the aluminum exposure limit were proposed. Proposal (1): For all types, 10 mg/m3 is unified as the exposure limit except for soluble salts and alkyls. Proposal (2): 1(R) mg/m3 as the exposure limit for all forms except soluble salts and alkyl. Proposal (3): 1(R) mg/m3 for pyro-powder and welding fume, and 10 mg/m3 for metal dust, aluminum oxide, and insoluble compounds as exposure standards. A pyro-powder was defined as dry aluminum powder of 200 mesh size (74 ㎛) or smaller (larger size classified as metal dust). Reason for setting: In the workplace survey, the ratio of respiratory dust to total dust was analyzed to be about 1:10, so it was judged that the domestic standard and the ACGIH standard were compatible. Conclusions: In all scenarios according to the revision of the exposure standard, the B/C ratio was greater than 1 or only benefits existed, so it was evaluated as sufficiently reasonable as a result of the socio-economic evaluation.

Distribution and Remineralization Ratio of Inorganic Nutrients in the Divergence Zone($7^{\circ}{\sim}10.5^{\circ}N$), Northeastern Pacific (북동태평양 발산대 해역($7^{\circ}{\sim}10.5^{\circ}N$)의 무기영양염 분포와 재무기질화 비율)

  • Son, Ju-Won;Kim, Kyeong-Hong;Kim, Mi-Jin;Son, Seung-Kyu;Chi, Sang-Bum;Hwang, Keun-Choon;Park, Yong-Chul
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.3
    • /
    • pp.178-189
    • /
    • 2008
  • The distribution of inorganic nutrients and their remineralization ratio in the divergence zone ($7^{\circ}{\sim}10.5^{\circ}N$) of the northeastern Pacific were investigated from July 2003 to July 2007. A divergence zone along the boundary of the North Equatorial Counter Current (NECC) and North Equatorial Current (NEC) at $10^{\circ}N$ was observed in July 2007 when the La Nina event and divergence-related upwelling was strong. The mean depth of oligotrophic surface mixed layer in the divergence zone was 46, 61, and 30 m in July 2003, August 2005, and July 2007, respectively. Below the surface mixed layer, a nutricline was clearly observed. The depth integrated value of nitrate including nitrite (DIVn) in the upper layer($0{\sim}100$ m depth) ranged from 5.51 to 21.71 $gN/m^2$(mean 12.82 $gN/m^2$) in July 2003, from 5.62 to 8.46 $gN/m^2$ (mean 7.15 $gN/m^2$) in August 2005, and from 8.98 to 27.80 $gN/m^2$(mean 21.12 $gN/m^2$) in July 2007. The maximum DIVn was observed at the divergence zone. The distributions of phosphate(DIVp) and silicate(DIVsi) were similar to that of DIVn and the DIVn/DIVsi ratio was $0.87{\pm}0.11$ in the upper layer. The limiting nutrient for phytoplankton growth in the study area was identified as nitrogen(N/P ratio=14.6). The nitrate (including nitrite) concentrations were lower in the region mainly affected by NEC than in the region affected by NECC. The study area of low silicate concentrations was also considered to be Si-limiting environment. The remineralization ratios of nutrients were $P/N/-O_2=1/14.6{\pm}1.1/100.4{\pm}8.8(23.44{\leq}Sigma-{\theta}{\leq}26.38)$ in the study area. These ratios suggested remineralization process in the surface layer of divergence zone.

A Study on Problems with the ROK's Bioterrorism Response System and Ways to Improve it (생물테러 대응체제의 문제점과 개선방안 연구)

  • Jung, Yook-Sang
    • Korean Security Journal
    • /
    • no.22
    • /
    • pp.113-144
    • /
    • 2010
  • Bioterrorism is becoming more attractive to terrorist groups owing to the dramatic increase in the utility and lethality of biological weapons in line with today's cutting-edge biological science and technology. The Republic of Korea is facing both internal and external terrorist threats, as well as the possible biological warfare by North Korea. Therefore, it is essential to establish an effective bioterrorism response system in the ROK. In order to come up with the adequate response system for the ROK, an in-depth study has been conducted on the current bioterrorism response system of the U.S. whose preparedness is considered relatively adamant. As a result, the following facts have been found: (1)the legislation with regard to bioterrorism has been established or amended according to the current situation in the U.S., (2)the counter terrorism activities have been integrated with the Department of the Homeland Security as the central agency in order to maximize the national CT capacity, (3)Specific procedures and instructions to cope with bioterrorism have been made into manuals so as to enhance the working-level response capabilities. Next, the analysis on the ROK's bioterrorism response system has been performed in various categories, including the legislation system, task role distribution, cooperative relations, and resource application. It turned out that the ROK's legislation basis is relatively weak and it lacks the apparatus to integrate the bioterrorism response activities on the national level. The shortage of the adequate response facilities and resources, as well as the poor management of manpower have also emerged as problems that hinder the effective CT implementations. Through an analytical and comparative study of the U.S. and the ROK systems, this paper presents several ways to ameliorate improve the current system in the ROK as follows: (1)establish the anti-terrorism law, which would be the basic legal basis for the bioterrorism-related matters; and make revisions to the disaster-related legislation, relevant to bioterrorism response activities, (2)establish an integrated body that has a powerful authority to coordinate the relevant CT agencies; and converge the decentralized functions to maximize the overall response capacity, (3)install the laboratories with a high biosafety level and secure enough of the strategic medical stock-pile, (4)enhance the ability of the inexperienced response personnel by providing with a manual that has detailed instructions.

  • PDF

A Study on the Hydraulic Characteristics of Rashig Super-Ring Random Packing in a Counter-Current Packed Tower (역류식 충전탑에서 Raschig Super-ring Random Packing의 수력학적 특성에 대한 연구)

  • Kang, Sung Jin;Lim, Dong-Ha
    • Clean Technology
    • /
    • v.26 no.2
    • /
    • pp.102-108
    • /
    • 2020
  • In recent years, packed column has been widely used in separation processes, such as absorption, desorption, distillation, and extraction, in the petrochemical, fine chemistry, and environmental industries. Packed column is used as a contacting facility for gas-liquid and liquid-liquid systems filled with random packed materials in the column. Packed column has various advantages such as low pressure drop, economical efficiency, thermally sensitive liquids, easy repairing restoration, and noxious gas treatment. The performance of a packed column is highly dependent on the maintenance of good gas and liquid distribution throughout a packed bed; thus, this is an important consideration in a design of packed column. In this study, hydraulic pressure drop, hold-up as a function of liquid load, and mass transfer in the air, air/water, and air-NH3/water systems were studied to find the geometrical characteristic for raschig super-ring experiment dry pressure drop. Based on the results, design factors and operating conditions to handle noxious gases were obtained. The dry pressure drop of the random packing raschig super-ring was linearly increased as a function of gas capacity factor with various liquid loads in the Air/Water system. This result is lower than that of 35 mm Pall-ring, which is most commonly used in the industrial field. Also, it can be found that the hydraulic pressure drop of raschig super-ring is consistently increased by gas capacity factor with various liquid loads. When gas capacity factor with various liquid loads is increased from 1.855 to 2.323 kg-1/2 m-1/2 S-1, hydraulic pressure drop increases around 17%. Finally, the liquid hold-up related to packing volume, which is a parameter of specific liquid load depending on gas capacity factor, shows consistent increase by around 3.84 kg-1/2 m-1/2 S-1 of the gas capacity factor. However, liquid hold-up significantly increases above it.