• Title/Summary/Keyword: corrugated web

Search Result 67, Processing Time 0.02 seconds

Full-scale tests and finite element analysis of arched corrugated steel roof under static loads

  • Wang, X.P.;Jiang, C.R.;Li, G.Q.;Wang, S.Y.
    • Steel and Composite Structures
    • /
    • v.7 no.4
    • /
    • pp.339-354
    • /
    • 2007
  • Arched Corrugated Steel Roof (ACSR) is a kind of thin-walled steel shell, composing of arched panels with transverse small corrugations. Four full-scale W666 ACSR samples with 18m and 30m span were tested under full and half span static vertical uniform loads. Displacement, bearing capacities and failure modes of the four samples were measured. The web and bottom flange in ACSR with transverse small corrugations are simplified to anisotropic curved plates, and the equivalent tensile modulus, shear modulus and Poisson's ratio of 18m span ACSR were measured. Two 18 m-span W666 ACSR samples were analyzed with the Finite Element Analysis program ABAQUS. Base on the tests, the limit bearing capacity of ACSR is low, and for half span loading, it is 74-75% compared with the full span loading. When the testing load approached to the limit value, the bottom flange at the sample's bulge place locally buckled first, and then the whole arched roof collapsed suddenly. If the vertical loads apply along the full span, the deformation shape is symmetric, but the overall failure mode is asymmetric. For half span vertical loading, the deformation shape and the overall failure mode of the structure are asymmetric. The ACSR displacement under the vertical loads is large and the structural stiffness is low. There is a little difference between the FEM analysis results and testing data, showing the simplify method of small corrugations in ACSR and the building techniques of FEM models are rational and useful.

Evaluation of Flexural Behavior of Prestressed Composite Beams with Corrugated Webs (파형웨브 프리스트레스트 합성보의 휨거동 평가)

  • Oh, Jae-Yuel;Lee, Deuck-Hang;Kim, Kang-Su;Kang, Hyun;Lee, Sofia;Bang, Yong-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.39-40
    • /
    • 2010
  • The demands for longer span and reduction of story height have greatly increased as building structures become much larger and higher in recent years. Although the development of flexural members for reducing story height or making long span has been studied by many researchers and engineers, there is still a lack of efficient systems that meet these two demands simultaneously. This study aimed at developing a new composite beam system suitable for long span and reduction of story height, and proposed a prestressed composite beam with corrugated web. It has great resistance against non-symmetric construction load due to its strong out-of-plane shear strength with relatively small member height as well as good constructability and economic efficiency by removing/minimizing form work. The corrugated webs also make accordion effect introducing larger effective prestressing force to top and bottom flanges, which causes larger upward camber reducing the member deflection. Five full-scale specimens with key test parameters, which are web sectional shapes and number of drape points, were tested to understand their flexural behavior and to verify the performance of the proposed method. The experimental test results showed that the proposed prestressed composite beam had greater flexural strength and stiffness than the ordinary non-prestressed composite beam.

  • PDF

Analysis on Torsional Behavior of PSC Box Girder with Corrugated Steel Web Considering Tensile Strength of Slab (슬래브의 인장강도를 고려한 복부 파형강판 PSC 박스거더의 비틀림 거동 분석)

  • Ko, Hee-Jung;Kim, Hyun-Su;Lee, Hak-Eun
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.41.1-41.1
    • /
    • 2010
  • 복부 파형강판 PSC 박스거더는 상부와 하부에 콘크리트 슬래브를 갖고 있으며, 복부에만 강판이 사용되는 특수한 형태의 교량이다. 해당 형식의 비틀림 거동을 이해하기 위해서는 상, 하부 콘크리트의 비틀림 거동에 대해 먼저 분석한 후, 비틀림에 의한 전단변형률이 거더 단면의 모든 구간에서 동일하다는 적합조건을 이용하여 복부의 비틀림 거동을 이해해야 한다. 기존의 복부 파형강판을 갖는 PSC 박스거더에 대한 연구는 전단거동(Easley, 1969; Elgaaly et al., 1996; 문지호 외, 2004; 이종원 외, 2005) 및 휨 거동(Elgaaly et al., 1997; Abbas et al., 2006, 2007; 문지호 외 2008)에 대하여 수행되어 왔으며, 이러한 연구들은 파형강판 자체에 국한되는 경향이 있다. 특히나 전체 복합거더의 비틀림 거동에 대한 연구는 크게 부족한 상황이며, 기존의 연구(Mo et al., 2000)는 균열 발생 이후의 비틀림 거동에 대해서만 수행되었고, 슬래브가 갖는 인장 강도를 무시하였다. 본 연구에서는 콘크리트의 비틀림 발생 이전과 이후를 모두 예측할 수 있는 방법을 제안하였고, 이를 토대로 시행오차법이 적용된 해석 알고리즘을 제작하였으며, 유한요소해석을 통하여 검증하였다.

  • PDF

Structural Safety Evaluation for 75,000 TDW Chemical Tanker Applied Common Structural Rules (CSR을 적용한 75,000 TDW 화학제품 운반선의 구조 안전성 평가)

  • Sim, Ye-Eun;Haa, Chung-In;Nam Gung, Mun;Kim, Gi-Jae;Lee, Kyung-Seok;Kim, Man-Soo
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2013.12a
    • /
    • pp.1-7
    • /
    • 2013
  • In past decades, a maximum standard vessel size for chemical tankers is not normally larger than 55,000 TDW due to the characteristic of chemical product shipment which is so variable but small quantity unlike single product carries such as crude oil tankers. These days, as demand of very large chemical tanker is rising due to the change of market trend of chemical product shipment, 75,000 TDW class chemical tanker has been developed. The newly developed vessel's structure has been designed based on CSR (Common Structural Rule) for double hull oil tankers (hereafter CSR) published by IACS (International Association of Classification Societies). However, due to the large difference from typical oil tankers, many items should be specially considered such as on deck transverse and corrugated bulkheads. In addition, two longitudinal bulkheads without upper stool have been constructed in order to maximise the number of cargo tanks and the volume of each cargo tanks. In this study, key word of the vessel has been briefly reviewed and the structural reliability of the proposed vessel has been investigated.

  • PDF

Structural efficiency of various strengthening schemes for cold-formed steel beams: Effect of global imperfections

  • Dar, M. Adil;Subramanian, N.;Dar, A.R.;Majid, Muheeb;Haseeb, Mohd;Tahoor, Mugees
    • Steel and Composite Structures
    • /
    • v.30 no.4
    • /
    • pp.393-403
    • /
    • 2019
  • Cold-formed steel (CFS) has a great potential to meet the global challenge of fast-track and durable construction. CFS members undergo large buckling instabilities due to their small wall thickness. CFS beams with corrugated webs have shown great resistance towards web buckling under flexure, when compared to the conventional I-sections. However, the magnitude of global imperfections significantly affects the performance of CFS members. This paper presents the first attempt made to experimentally study the effect of global imperfections on the structural efficiency of various strengthening schemes implemented in CFS beams with corrugated webs. Different strengthening schemes were adopted for two types of beams, one with large global imperfections and the other with small imperfections. Strength and stiffness characteristics of the beams were used to evaluate the structural efficiency of the various strengthening schemes adopted. Six tests were performed with simply supported end conditions, under four-point loading conditions. The load vs. mid-span displacement response, failure loads and modes of failure of the test specimens were investigated. The test results would compensate the lack of experimental data in this area of research and would help in developing numerical models for extensive studies for the development of necessary guidelines on the same. Strengthening schemes assisted in enhancing the member performance significantly, both in terms of strength and stiffness. Hence, providing an economic and time saving solution to such practical structural engineering problems.

Numerical Parametric Analysis of the Ultimate Loading-Capacity of Channel Purlins with Screw-Fastened Sheeting

  • Zhang, Yingying;Xue, Jigang;Song, Xiaoguang;Zhang, Qilin
    • International journal of steel structures
    • /
    • v.18 no.5
    • /
    • pp.1801-1817
    • /
    • 2018
  • This paper presents the numerical parametric analysis on the loading capacity of Channel purlins with screw-fastened sheeting, in which the effects of anti-sag bar and corrugated steel sheet on the ultimate capacity are studied. Results show that the setup of anti-sag bars can reduce the deformations and improve the ultimate capacity of C purlins. The traditional method of setting the anti-sag bars in the middle of the web is favorable. The changing of sheeting type, sheeting thickness and rib spacing has significant effects on the ultimate capacity of C purlins without anti-sag bars, compared with those with anti-sag bars. The proposed design formulas are relatively consistent with the calculations of EN 1993-1-3:2006, which is different from those of GB 50018-2002.

Deflection Evaluation of the Constructing-load Carrying Capacity for Deep Decking Floor System Reinforced with Both Ends Cap Plates (캡 플레이트로 단부 보강한 춤이 깊은 데크의 시공중 처짐성능평가)

  • Jeon, Sang Hyun;Kyung, Jae Hwan;Kim, Young Ho;Choi, Sung Mo;Yang, Il Seung
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.2
    • /
    • pp.155-167
    • /
    • 2015
  • If of application of the deep deckting floor in long span more than 6m, the deflection caused by the construction load occurred high. Because the constructing-works and safety by this deflection, take actually supports to laborers working on the deck. However, installed supports are having difficultly such as the restricted passage, deficiency of working space, and lowering of efficiency. And toward-opening deck is seen as local buckling of web plate, flexural-torsional buckling, and gradually opening of corrugated decking. In this study, we will suggest a deep decking floor system that reinforced with both ends cap plates for toward-opneing decking change from opening to closing. The constructing deflection of a deep decking more than 6m must be satified 30mm and L/180 as proposed. Full-scale field tests loading by sand conducted a deep decking reinforced with and without cap plate. In conclusion, the specimen reinforced with cap plates have shown that to ensure the negative moment $wl^2/18$. And constructing-deflection of deep decking shown that to satisfy the evaluation value (L/180 or 30mm).