• Title/Summary/Keyword: corrosion rates

Search Result 270, Processing Time 0.031 seconds

The effects of Si-content on the corrosion rate of Cu-al alloys (동일 알루미늄 합금의 탄식속도에 미치는 규소의 영향)

  • Ham, Dong-Ha;Kang, Tak;Kang, Choon-Sik
    • Journal of the Korean institute of surface engineering
    • /
    • v.14 no.1
    • /
    • pp.5-9
    • /
    • 1981
  • The effects of silicon content on the corrosion rates of Cu-7wt% Al alloys have been investigated by the use of electrochemical methods. The corrosion current densities of the alloys are decreased with the addition of Si up to 2wt%, and the slightly increased at 2.5%Si. This increased corrosion rates are attributed to the precipitation of more anodic gamma-2 phase. The X-ray diffraction tests reveal the dealuminumification of these alloys and mixtures of CuCl and Al2O3 formed on the surface of the specimens, which are considered to passivate the alloys at noble potentials.

  • PDF

Corrosion Characteristics of Gold-Coated Silver Wire for Semiconductor Packaging (반도체 패키징용 금-코팅된 은 와이어의 부식특성)

  • Hong, Won Sik;Kim, Mi-Song;Kim, Sang Yeop;Jeon, Sung Min;Moon, Jeong Tak;Kim, Youngsik
    • Corrosion Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.289-294
    • /
    • 2021
  • In this study, after measuring polarization characteristics of 97.3 wt% Ag, Au-Coated 97.3 wt% Ag (ACA) and 100 wt% Au wires in 1 wt% H2SO4 and 1 wt% HCl electrolytes at 25 ℃, corrosion rate and corrosion characteristics were comparatively analyzed. Comparing corrosion potential (ECORR) values in sulfuric acid solution, ACA wire had more than six times higher ECORR value than Au wire. Thus, it seems possible to use a broad applied voltage range of bonding wire for semiconductor packaging which ACA wire could be substituted for the Au wire. However, since the ECORR value of ACA wire was three times lower than that of the Au wire in a hydrochloric acid solution, it was judged that the use range of the applied voltage and current of the bonding wire should be considered. In hydrochloric acid solution, 97.3 wt% Ag wire showed the highest corrosion rate, while ACA and Au showed similar corrosion rates. Additionally, in the case of sulfuric acid solution, all three types showed lower corrosion rates than those under the hydrochloric acid solution environment. The corrosion rate was higher in the order of 97.3 wt% Ag > ACA > 100 wt% Au wires.

Experimental Study on Corrosion Rate in Concrete

  • Jang, BongSeok;Oh, ByungHwan
    • Corrosion Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.34-38
    • /
    • 2004
  • The corrosion of reinforcement is a very important factor on the serviceability and safety of reinforced concrete structures. The corrosion rate influences directly the cover failure time of reinforced concrete structures because the corrosion rate is used to estimate the amount of corrosion and thus expansive pressure due to corrosion. In this study, several series of experiments are performed considering the chloride concentration in artificial pore solution. The potentials are measured according to the applied current density and then corrosion current densities are obtained from the Tafel plot for various chloride concentrations. The measured corrosion rates show good correlation with those of other researchers.

A Study on Corrosion Fatigue Crack Growth Behavior in Al-Alloy 7075-T651 (I) (Al-Alloy 7075-T651의 부식피로균열 성장거동에 관한 연구(I))

  • 김봉철;한지원;우흥식
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.113-120
    • /
    • 1998
  • Fatigue crack growth rates(i.e. crack initiation and crack growth of short and long crack) are investigated using commercial plates of high strength Al alloy 7075-T651 for the transverse-longitudinal(T-L) direction in air, water and sea water. Also, the evaluation direct current potential drop(D.C.P.D) method and the fractographical analysis by SEM are carried out. Near threshold region, short crack growth rates were much faster than those of comparable long cracks, and these short crack growth rates actually decrease with increasing crack growth and eventually merge with long crack data. Fatigue crack propagation rates in aggressive media(i.e. sea water) increase noticeably over three times those in air. One of the most significant characters in this phenomenon as a corrosion-fatigue causes an acceleration in crack growth rates. Sea water environment, particularly Cl$^{[-10]}$ solution brings the most detrimental effects to aluminum alloy. The result of fractographical morphology in air, water and sea water by SEM shows obvious dimpled rupture and typical striation in air, but transgranular fracture surface in water and sea water.

  • PDF

Monitoring of Atmospheric Corrosivity inside Steel Upper Box Girder in Yeongjong Grand Bridge

  • Li, SeonYeob
    • Corrosion Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.87-94
    • /
    • 2011
  • The typical corrosion prevention method inside the steel upper box girder in a suspension bridge involves the use of paints. However, in an effort to reduce environmental impact and cost, the suspension portion of the Yeongjong Bridge, Korea utilizes dehumidification systems to control humidity and prevent corrosion inside its box girder. Maintaining a uniform humidity distribution at the proper level inside the box girder is critical to the successful corrosion control. In this study, the humidity and the resultant atmospheric corrosivity inside the box girder of the Yeongjong Bridge was monitored. The corrosion rate of the steel inside the box girder was obtained using thin-film electrical resistance (TFER) corrosion sensors. Time-of-wetness (TOW) measurements and the deposition rates of atmospheric pollutants such as $Cl^{-}$ and $SO_{x}$ were also obtained. Classification of the atmospheric corrosivity inside the box girder was evaluated according to ISO 9223. As a result, no corrosion was found in the upper box girder, indicating that the dehumidification system used in the Yeongjong Bridge is an effective corrosion control method.

Biocides Effect on the Microbiologically Influenced Corrosion of Pure Copper by Desulfovibrio sp.

  • Onan, Mert;Ilhan-Sungur, Esra;Gungor, Nihal Dogruoz;Cansever, Nurhan
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.44-50
    • /
    • 2018
  • The aims of this study were to determine the corrosion behavior of pure copper in the presence of Desulfovibrio sp. and also to investigate the effects of glutaraldehyde (GD) and isothiazolinone (ISO) on the corrosion behavior of pure copper in the presence of this sulfate-reducing bacteria (SRB) strain by using electrochemical techniques. Electrochemical measurements of pure copper were carried out at specified time intervals (0, 8, 24, 48, and 96 hr) over a period of exposure. Corrosion rates of pure copper from anodic and cathodic Tafel slopes and corrosion potential ($E_{corr}$) were determined. Biofilm and corrosion products on the copper surfaces were observed by Field Emission Scanning Electron Microscopy (FESEM) and Energy Dispersive X-Ray Spectrometry (EDS) analyses. The effects of solution types (PC (Postgate's C medium) and SRB (Desulfovibrio sp.)) and exposure times of copper and biocides (ISO or GD) on the corrosion rates of pure copper were evaluated by statistical analyses. As a result of the FESEM analysis, biofilm formation was observed on the surfaces of pure copper exposed to the Desulfovibrio sp. cultures both with and without the biocides. The results show that the pure copper was corroded by Desulfovibrio sp. However, the addition of GD or ISO to the Desulfovibrio sp. culture resulted in a decrease in the corrosion rate of the pure copper. It was also observed that both of the biocides showed a similar effect on pure copper's corrosion rate caused by Desulfovibrio sp.

Corrosion Fatigue Crack Propagation Behaviour of TMCP Steel Plate at Ballast Tank of Ship Structure under the Condition of Cathodic Overprotection (선체구조 Ballast Tank 고장력 TMCP강판의 과방식중 부식피로균열 전파거동)

  • Kim, Won-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2465-2471
    • /
    • 2012
  • For the steel structures those are used in harsh sea environments, corrosion fatigue is a challenging issue in connection with design life. In this research, in order to investigate the influence of cathodic overprotection on the corrosion fatigue crack propagation behavior, corrosion fatigue crack propagation test under the condition of -950mV vs SCE was conducted by using of high tensile TMCP steel plate and the relationships between da/dN-${\Delta}K$ were obtained. At this test, when ${\Delta}K$ is low, the crack propagation rates were accelerated compared to those of seawater condition, however, when ${\Delta}K$ is high, the crack propagation rates were lower than those of seawater condition. As the cause for the acceleration and deceleration of corrosion fatigue crack propagation rates under the condition of cathodic overprotection, the role of hydrogen and calcareous deposits are discussed.

Prediction of Steel Corrosion and Corrosion Cracking in Reinforced Concrete Structures (철근콘크리트 구조물의 철근부식과 부식균열의 발생 예측)

  • 김호진;조호진;송하원;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.657-662
    • /
    • 2003
  • In this study. a micro-corrosion model of steel in RC structure is established for micro-structure development in view to micro-mechanics and the model is composed of chloride penetration model and oxygen diffusion model to evaluate for corrosion rate and accumulated corrosion amounts. Also the model is composed of corrosion-cracking model for prediction of corrosion-cracking. The time and space dependent induced corrosion-cracking of RC structures including changes of corrosion rates and concentrations of chloride ion are simulated using the finite element analysis adopted the proposed model Then, results of the analysis are compared with test results for verification.

  • PDF

A Case Study on Corrosion Rates of Concrete Sewer Pipes in Housing Sites (주택단지 오수용 콘크리트 흄관의 부식속도 측정 사례)

  • Kim, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.550-553
    • /
    • 2006
  • This study measured corrosion rates for checking and analysis of Hume pipes in the housing sites. According to the result, Concrete pipe is deteriorating for twenty years by hydrogen sulfide(H2S). Investigation method applied phenolphthalein method(depth of neutrality). Phenolphthalein method measured average depth from concrete surface to coloring point by red after spraying phenolphthalein solution. A result of investigation, Life span of Hume pipe in the housing site is investigated of twenty years.

  • PDF

Development of Copper Corrosion Products and Relation between Surface Appearance and Corrosion Rate

  • Tran, Thi Ngoc Lan;Nguyen, Thi Thanh Binh;Nguyen, Nhi Tru;Yoshino, Tsujino;Yasuki, Maeda
    • Corrosion Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.99-111
    • /
    • 2008
  • Copper was exposed unsheltered and sheltered in four humid tropical sites, representing urban, urban-industrial, urban-marine and rural environments. The corrosion rates and the sequence of corrosion product formation are presented and discussed in relation with climatic and atmospheric pollution parameters. Chemical compositions of corrosion products were found to depend on environments and duration of exposure. In all environments, cuprite was the predominating corrosion product that formed first and continuously increased during the exposure. Among the sulphur-containing corrosion products, posnjakite and brochantite were more frequently found and the first formed earlier. Nantokite was the most common chlorine-containing products for most cases, except the high-chloride environment, where atacamite was detected instead. The corrosion rate of copper was well indicated by the colour of patina. The red-purple colour corresponded to the high corrosion rate and the greenish grey colour corresponded to the low corrosion rate. Corrosion rate of sheltered copper in urban-marine environment increased with the exposure time.