• Title/Summary/Keyword: corrosion area

검색결과 571건 처리시간 0.028초

3.5% NaCl 수용액 중에서의 금속과 GECM의 갈바닉 부식에 미치는 면적비의 영향 (Effect of Area Ratio on Galvanic Corrosion Between Metallic Materials and GECM in 3.5% NaCl Solution)

  • 김영식;임현권;손영일;유영란;장현영
    • Corrosion Science and Technology
    • /
    • 제9권1호
    • /
    • pp.39-47
    • /
    • 2010
  • Galvanic coupling between GECM(graphite epoxy composite material) and metallic materials can facilitate corrosion of metals and alloys because GECM is noble and electrically conductive. Galvanic corrosion is affected by many factors including metallic materials, area ratio, surface condition, and corrosivity. This work aims to evaluate the effect of area ratio on galvanic corrosion between GECM and several metals. In the case of glavanic coupling of carbon steel and Al to GECM, corrosion rate increased with increasing area ratio. Corrosion rate of sensitized STS 316S stainless steel decreased a little at an area ratio 1:1 but increased at an area ratio 30:1. It is considered to be due to that area ratio affects galvanic corrosion more in less corrosion resistant alloys. However, in case of STS 316 and Ti, galvanic coupling reduces corrosion rate by the formation of passive film.

IN713LC-SCM440 이종재 마찰용접부의 부식특성에 미치는 pH의 영향 (The Effects of pH on the Corrosion Characteristics in Dissimilar Friction Welded Zone of IN713LC-SCM440)

  • 조상근;공유식;김영대
    • 한국해양공학회지
    • /
    • 제19권2호
    • /
    • pp.53-59
    • /
    • 2005
  • The effect of pH on the corrosion characteristics in the dissimilar friction welded zone of IN713LC-SCM440 in the loaded torsional stress was studied. The corrosion experiment was performed for 120 hours on the specimens with five steps of pH. The surface corrosion pattern of the SCM440 area showed global corrosion and narrow pitting, which was caused by galvanic corrosion between friction welded IN713LC and SCM440, but corrosion did not proceeded from the IN713LC area. The average relative electrode potential gradually tends to decrease with the elapse of the immersion time in the acidity area. The average corrosion current also gradually tend to decrease The corrosion rate showed a larger value when the average relative electrode potential was higher and the average relative current was lower. The corrosion rate showed a larger value when the average relative electrode potential was higher in the acidity area, and it showed large when the average relative electrode potential was lower in the alkalinity area.

Elastic local buckling behaviour of corroded cold-formed steel columns

  • Nie Biao;Xu Shanhua;Hu WeiCheng;Chen HuaPeng;Li AnBang;Zhang ZongXing
    • Steel and Composite Structures
    • /
    • 제48권1호
    • /
    • pp.27-41
    • /
    • 2023
  • Under the long-term effect of corrosive environment, many cold-formed steel (CFS) structures have serious corrosion problems. Corrosion leads to the change of surface morphology and the loss of section thickness, which results in the change of instability mode and failure mechanism of CFS structure. This paper mainly investigates the elastic local buckling behavior of corroded CFS columns. The surface morphology scanning test was carried out for eight CFS columns accelerated corrosion by the outdoor periodic spray test. The thin shell finite element (FE) eigen-buckling analysis was also carried out to reveal the influence of corrosion surface characteristics, corrosion depth, corrosion location and corrosion area on the elastic local buckling behaviour of the plates with four simply supported edges. The accuracy of the proposed formulas for calculating the elastic local buckling stress of the corroded plates and columns was assessed through extensive parameter studies. The results indicated that for the plates considering corrosion surface characteristics, the maximum deformation area of local buckling was located at the plates with the minimum average section area. For the plates with localized corrosion, the main buckling shape of the plates changed from one half-wave to two half-wave with the increase in corrosion area length. The elastic local buckling stress decreased gradually with the increase in corrosion area width and length. In addition, the elastic local buckling stress decreased slowly when corrosion area thickness was relatively large, and then tends to accelerate with the reduction in corrosion area thickness. The distance from the corrosion area to the transverse and longitudinal centerline of the plate had little effect on the elastic local buckling stress. Finally, the calculation formula of the elastic local buckling stress of the corroded plates and CFS columns was proposed.

Titanium 전열관을 사용하는 원전 복수기 재료의 Galvanic Corrosion에 미치는 면적의 영향 (Area Effect on Galvanic Corrosion of Condenser Materials with Titanium Tubes in Nuclear Power Plants)

  • Hwang, Seong-Sik;Kim, Joung-Soo;Kim, Uh-Chul
    • Nuclear Engineering and Technology
    • /
    • 제25권4호
    • /
    • pp.507-514
    • /
    • 1993
  • Titanium재료는 해수에서 좋은 내식성을 가지는 이유로 최근 원자력발전소 복수기에 사용되고 있다. 그러나, Ti이 tubesheet재 료인 Cu 합금에 접하고 이것이 water box 재료인 탄소강에 접하게될 경우 접촉금속에 심한 galvanic corrosion이 일어나게 된다. 전기화학적 실험에 의하면, 탄소강이 해수속에서 Ti나 Cu에 접할 때 탄소강의 부식속도는 증가할 것이며, Cu가 Ti에 해수중에서 장기간 접촉할 경우에는 Cu의 부식속도는 증가할 것으로 생각된다, 또한 표면적비, R$_1$(surface area of carbon steel/surface area of Ti).와 R$_2$(surface area of carbon steel/surface area of Cu)가 탄소강의 galvanic corrosion에 매우 중요하며. Water box 재료인 탄소강의 부식속도를 최소화하기 위해서는 이들 표면적비가 낮게 유지되어서는 안될 것이라고 생각된다 침지 galvanic 부식 시험결과 surface area of Fe/surface area of Al Brass값이 1일때 탄소강의 부식속도는 4.4mpy 이었으나 이 비가 $10^{-2}$ 일때는 570mpy이었다. 이렇게 연결된 galvanic시편에 Ti tube를 연결한 경우에는 이 비가 1일때 탄소강의 부식율이 4.4mpy에서 13mpy로 증가하였다. 이는 R$_1$가 R$_2$가 분극곡선에 복합적인 영향을 미치는것으로 설명할 수 있다.

  • PDF

도장이 필요없는 내후성강 박스거더 상부 플랜지외부면 방식제 주입을 통한 방식공법 연구 (The study on the protection method from corrosion by the sealant injection on the unpainted weathering steel top flange outer surface of box girder)

  • 송창영
    • Corrosion Science and Technology
    • /
    • 제13권4호
    • /
    • pp.139-144
    • /
    • 2014
  • In corrosion-sensitive area of exsisting unpainted weathering steel bridge with closed box girder structure. there are some serious local corrosion problems because of rain water or dew water which can not be solved by conventional maintenance method. These problems must be technically controled because of the influence on the safety of bridge. This study is the first stage of developing the economic corrosion control manual for these local corrosion problems. Through the injecting experiment of tar sealant into the crevice of mock-up equipment, it was proofed that the corrosive sealant can be useful to corrosion control at crevice of corrosion sensitive area.

Galvanic Corrosion of AZ31 Mg Alloy Contacting with Copper

  • Phuong, Nguyen Van;Moon, Sungmo
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.151.1-151.1
    • /
    • 2017
  • This work studied the corrosion behavior of AZ31 Mg alloy galvanically coupled with Cu during immersion in 0.1 and 0.5 M NaCl solutions by in-situ observation and galvanic corrosion current measurement using a zero resistance ammeter. The corrosion behavior of AZ31 Mg alloy was also studied by salt spray test. The average galvanic corrosion density during 2 h immersion in 0.1 NaCl solution was found to decrease as an exponential function with increasing the surface area ratios between AZ31:Cu or with increasing the distance between AZ31 and Cu. The corrosion of electrodeposited Cu on AZ31 Mg alloy was concentrated at the area next to Cu (about 5 mm for immersion test and 2 mm for salt spray test) and pitting corrosion was accelerated at the area beyond the severely corroded area by the galvanic coupling effect.

  • PDF

선박용 디젤엔진 과급기 로터 접합체의 부식특성에 미치는 비틀림응력의 영향 (Effects of Torsional Stress on the Corrosion Characteristics in the Rotor Assembly of Marine Diesel Engine Supercharger)

  • 조상근;공유식;김영대
    • 동력기계공학회지
    • /
    • 제9권1호
    • /
    • pp.50-56
    • /
    • 2005
  • The corrosion experiment was performed for 120 hours on the specimens in the natural seawater tank with four steps of the loaded torsional stress. The surface corrosion pattern of SCM440 area was showed global corrosion and narrow pitting, that was cause by galvanic corrosion between friction welded IN713LC and SCM440. But corrosion does not proceeded from IN713LC area. Initially, the average relative electrode potential and corrosion current were decreased suddenly, by and large, it was stabilized gradually tend to decreasing with the elapse of the immersion time. The corrosion rate was decreased by increasing the load stress, but 200 MPa specimen was showed most large value.

  • PDF

부식속도에 대한 참조 표준 작성을 위한 수환경에 따른 각종 금속의 부식특성 평가 - I. 안동지역 (Evaluation of Corrosion Properties of Several Metals in Waters for Reference Standard on Corrosion Rate - I. Andong Area)

  • 심규태;권용혁;김영식
    • Corrosion Science and Technology
    • /
    • 제8권6호
    • /
    • pp.238-242
    • /
    • 2009
  • Corrosion of metallic materials occurs by the reaction with corrosive environment. In general, corrosive environments are classified as atmospheric, marine, soil etc. and regardless of any corrosive environments, reduction of thickness and cracking and degradation are induced by corrosion. Among several corrosive environments, knowing the atmospheric corrosiveness of a region, city, or country is considered of ultimate importance for major industrialists and investors who require knowledge of the corrosive impact of the atmosphere on everyday materials such as carbon steel, weathering steel, zinc, copper, and aluminium. This is why the atmospheric corrosiveness map is needed. This paper dealt with corrosion properties between several waters in the region and carbon steel, weathering steel, galvanized steel, pure copper, and pure aluminium at the representative rural area of Korea - Andong.

아산지역에서 산업재료의 대기부식속도 측정 (Atmospheric corrosion rate and corrosivity categories of industrial metals in Asan area)

  • 김진형;이종권
    • 한국산학기술학회논문지
    • /
    • 제14권10호
    • /
    • pp.4653-4657
    • /
    • 2013
  • 4년간 아산지역에서 5가지 산업재료의 부식속도를 측정하였다. 이 연구는 전국의 21개 지역을 농촌, 해안, 공업도시로 구분하여 그 중 아산지역에서 시편을 대기에 노출 시켰을 때의 부식속도를 알아보고 이를 산업용으로 사용되는 금속의 Database로 하고자 하였다. 실험에 사용된 시편은 산업재료로 많이 사용되는 알루미늄, 구리, 탄소강, 내후성강, 아연도강이다. 탄소강과 내후성강의 부식속도와 무게감소량이 다른 금속에 비해 높았으며 sanding 처리한 시편의 부식속도가 sanding처리하지 않은 시편보다 부식속도가 낮게 나타났다. 아산 지역의 평균 Corrosion categories는 3으로 나타났다. 아산지역의 Corrosion categories는 해안지역보다는 낮게 나타났으며 농촌지역보다는 높게 나타났다. 염화물 이온의 농도가 커짐에 따라 부식속도가 커지는 경향을 나타낸다.

표면피복종류에 따른 복합열화환경하의 철근콘크리트 부식특성에 관한 실험적 연구 (An experimental study on corrosion properties of reinforcing steel under environment of complex deterioration)

  • 조봉석;김영덕;윤종기;김재환;김용로;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.86-89
    • /
    • 2003
  • It is recognized that reinforcement corrosion is the main distress behind the present concern regarding concrete durability. In this study, to confirm corrosion of reinforced concrete affected by thickness of cover, kinds of surface coating, measured electric potential, ratio of corrosion area, weight reduction, corrosion velocity of steel bar under environment of complex deterioration. The results showed that an increase in age also increases corrosion of steel bar. Ratio of corrosion area is largely related to ratio of weight reduction. as well, corrosion of steel bar by thickness of cover is superior to l0mm thick than 20mm thick. It showed that an increase in thickness of cover prevent steel bar from deteriorating. The results of this study showed that corrosion velocity was affected by thickness of cover, kinds of surface coating. data on the development of corrosion velocity made with none, organic B, organic A, inorganic B, and inorganic A is shown.

  • PDF