• Title/Summary/Keyword: correlation measure

Search Result 2,644, Processing Time 0.037 seconds

Evaluation of Skin Microcirculation by Laser Doppler Flowmeter in Healthy Beagle Dogs

  • Kim, Juntaek;Bae, Seulgi;Lee, Keunwoo;OH, Taeho
    • Journal of Veterinary Clinics
    • /
    • v.34 no.4
    • /
    • pp.249-254
    • /
    • 2017
  • The cutaneous microcirculation plays a role in various physiological processes and pathological conditions. Two non-invasive methods were used in this study to obtain reference values for cutaneous microcirculation in intact male beagles. Twenty intact male beagles were used. The experimental environments were standardized. Laser Doppler flowmetry was used to measure cutaneous blood flow, and an infrared thermometer was used to measure cutaneous temperature. The blood flow and temperature were measured from the right side of the subjects at 20 cutaneous sites. Based on the laser Doppler flowmetry, the region with the highest blood flow was the periocular region that with the lowest was the forelimb foot pad. In addition, the standard deviation of the chest wall was the highest while that of the periocular region was the lowest. For skin temperature, the inguinal region had the highest mean skin temperature and the forelimb foot pad had the lowest. The correlation coefficient between the two methods was 0.72. Similar to a previous study, the values derived from repeated measurements at the 20 regions are reproducible and can contribute to research. Compared to the results of a previous study, the temperatures of the two smallest skin regions were the same; however, no specific trend was observed. The correlation coefficient between the two methods was significantly comparable, and this good correlation can reduce their limitations and variables complementarily. In addition to possible use in human studies, accumulated resources on measurements of skin blood flow in the future will potentiate its use in the veterinary medicine field.

Application of Digital Image Correlation Method for Measurement of Rock Pillar Displacement and Vibration Due to Underground Mine Blasting (지하 광산발파에 따른 암반광주의 변위 및 진동 측정을 위한 이미지 영상 상관법 적용연구)

  • Ko, Young-Hun;Seo, Seung-Hwan;Lim, Hyun-Sung;Jin, Tai-Lie;Chung, Moon-Kyung
    • Explosives and Blasting
    • /
    • v.37 no.4
    • /
    • pp.1-9
    • /
    • 2019
  • In this study the applicability of a Digital Image Correlation (DIC) method was investigated by measuring the displacement and vibration of rock pillar due to underground mining blasting. When combined with a high speed photography technology, the DIC method provides an excellent photographic image processing ability that can be used to convert the evolving full-field surface properties of structures to 2D or 3D set of coordinate values. The measured coordinate sets are then used to calculate the displacement, strain, and velocity of the target structure. This technique is widely used in science and engineering, and continuously finds its new application areas. In this study, the DIC system and the conventional seismograph were compared for their ability to measure the displacement and vibration produced by blasting. In the field test both methods showed similar results. Thus, it is concluded that the DIC method is feasible to measure the ground displacements and vibrations from blasting.

The Effects of Audit Quality on Audit Performance (감사품질이 감사성과에 미치는 요인에 관한 연구)

  • Choi, Gwangyun;Park, JongWoo
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.1
    • /
    • pp.113-134
    • /
    • 2018
  • Purpose: The purpose of this study was to clarify the causal relationship and correlation between audit quality and audit performance and to analyze theoretical discussions and actual facts in order to improve audit performance on public enterprise audit and to identify what factors contribute to management and to seek ways to secure business performance. Methods: In this study, theoretical consideration was conducted that concerned the definition of audit, the concept of internal audit, the audit quality and the audit performance after having considered advanced researches, related regulations, and literatures. Through the foundation of such theoretical consideration, the components of the audit quality were deducted and each component's impact on the audit performance was empirically proven. The collected data through the survey were analyzed using multi-regression analysis. The measurement tools used for this study were divided into three dimensions such as internal quality, interaction quality and environmental quality. Result: First remark, out of the various components of the audit quality, independence, professionalism, and empathy appear to positively impact the audit degree of satisfaction. However, the measure of sufficiency is shown to bear no correlation to the audit degree of satisfaction. Second, out of the various components of the audit quality, professionalism, sufficiency, and empathy appear to positively impact the audit degree of applicability. However, the measure of independence is shown to bear no correlation to the audit degree of applicability. Third, audit quality appears to positively impact the audit degree of satisfaction and applicability, and also the performance of management. Concusion: It appears that the audit quality positively impacts the audit degree of satisfaction, applicability and management performance indicated by the audit performance.

Crack Resistance Behavior Using Digital Image Correlation and Crack Tip Opening Angle on Particulate Reinforced Composite (디지털 화상관련법 및 균열선단열림각도를 이용한 입자강화 복합재료의 균열저항거동)

  • Na, Seong Hyeon;Lee, Jeong Won;Kim, Jae Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.12
    • /
    • pp.1021-1026
    • /
    • 2016
  • In this study, crack resistance is evaluated by the crack tip opening angle (CTOA) using a wedge splitting test (WST) on a viscoelastic particulate reinforced composite based on an HTPB binder. Generally, CTOA, as a function of crack extension, is used in order to determinate fracture resistance and has a steady state relative angle. Digital image correlation (DIC) is used to measure the crack tip opening displacement (CTOD) and crack extension for the critical crack tip opening angle (CTOAc). In these results, the CTOAc value of a particulate reinforced composite tends to approach a constant angle after a small amount of crack extension. The CTOAc value increases with decreasing temperature, from $50^{\circ}C$ to $-40^{\circ}C$. These CTOAc values may be used to measure fracture mechanics parameters for particulate reinforced composite.

Development of Ultrasonic Sensor to Measure the Distance in Underwater (수중 거리 측정을 위한 초음파 센서의 개발)

  • Kim, Chi-Hyo;Kim, Tae-Sung;Jung, Jun-Ha;Lee, Jin-Hyung;Lee, Min-Ki;Jang, In-Sung;Shin, Chang-Joo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.06a
    • /
    • pp.293-298
    • /
    • 2013
  • This research develops an ultrasonic sensor to measure the distance in underwater. The ultrasonic transducer transmits an acoustic signal to an object and receives the echo signal reflected from the object. The ultrasonic driver calculates a distance by multiplying the acoustic speed to the time of flight(TOF) which is the time necessary for the acoustic signal to travel from the transducer to the object. We apply a thresholding and a cross correlation methods to detect the TOF and show their results. When an echo pulse is corrupted with noise and its shape is distorted, the cross correlation method is used to find the TOF based on the maximum similarity between the reference and the delayed echo signals. The echoes used for the reference signal are achieved at the different environments, which improves the performance of the sensor. This paper describes the driver of the acoustic sensor and analyzes the performance of sensors in different measurement environments.

  • PDF

Concurrent Validity and Test-retest Reliability of the Core Stability Test Using Ultrasound Imaging and Electromyography Measurements

  • Yoo, Seungju;Lee, Nam-Gi;Park, Chanhee;You, Joshua (Sung) Hyun
    • Physical Therapy Korea
    • /
    • v.28 no.3
    • /
    • pp.186-193
    • /
    • 2021
  • Background: While the formal test has been used to provide a quantitative measurement of core stability, studies have reported inconsistent results regarding its test-retest and intraobserver reliabilities. Furthermore, the validity of the formal test has never been established. Objects: This study aimed to establish the concurrent validity and test-retest reliability of the formal test. Methods: Twenty-two young adults with and without core instability (23.1 ± 2.0 years) were recruited. Concurrent validity was determined by comparing the muscle thickness changes of the external oblique, internal oblique, and transverse abdominal muscle to changes in core stability pressure during the formal test using ultrasound (US) imaging and pressure biofeedback, respectively. For the test-retest reliability, muscle thickness and pressure changes were repeatedly measured approximately 24 hours apart. Electromyography (EMG) was used to monitor trunk muscle activity during the formal test. Results: The Pearson's correlation analysis showed an excellent correlation between transverse abdominal thickness and pressure biofeedback unit (PBU) pressure as well as internal oblique thickness and PBU pressure, ranging from r = 0.856-0.980, p < 0.05. The test-retest reliability was good, intraclass correlation coefficient (ICC1,2) = 0.876 for the core stability pressure measure and ICC1,2 = 0.939 to 0.989 for the abdominal muscle thickness measure. Conclusion: Our results provide clinical evidence that the formal test is valid and reliable, when concurrently incorporated into EMG and US measurements.

Association between body composition parameters and non-specific low back pain in sedentary workers

  • Kim, Wondeuk;Park, Dongchun;Shin, Doochul
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.1
    • /
    • pp.64-68
    • /
    • 2021
  • Objective: In clinical practice, there are a lot of exercise to reduce body weight or reduce the amount of body fat in order to solve back pain. However, many studies have contradicted the relationship between back pain and weight or body fat mass. The purpose of this study was to investigate the relationship between fat mass, body mass index and low back pain of office worker. Design: Crossed-sectional study Methods: Among the white-collar workers diagnosed with non-specific back pain by doctors, subjects who were not included in the exclusion criteria were selected to measure the subject's body fat mass, body mass index, pain intensity, and disability index due to back pain. The NPRS was used for the intensity of back pain of office workers, and the ODI was used for the degree of disability due to back pain. A body composition analyzer was used to measure the body fat mass and body mass index of white-collar workers. Results: There was no significant difference between the two groups in the comparison between the normal group and the excessive group according to the criteria of fat mass and body mass index. In the correlation analysis of fat mass, body mass index, pain intensity, and disability index, it was found that there was a significant correlation between fat mass and body mass index. However, neither fat mass nor body mass index had a significant correlation with pain intensity and disability index. Conclusions: The fat mass and body mass index of office worker do not affect low back pain.

Verification of Reproducibility of VCS2000 Equipment for Mechanical Measurement of Korean Landrace×Yorkshire (F1), F1×Duroc (LYD) Pig Carcasses

  • Yunhwan Park;Kwantae Kim;Jaeyoung Kim;Jongtae Seo;Jungseok Choi
    • Food Science of Animal Resources
    • /
    • v.43 no.4
    • /
    • pp.553-562
    • /
    • 2023
  • With an increase in meat consumption, the need to measure the weight of each primal cut of pork has increased. Recently, automation devices have been used to measure the weight of each primal cut of pork. The objective of this study was to investigate the accuracy of VCS2000, one of the non-invasive pig carcass analyzers. Production levels of 7 primal cuts of 50 pigs were measured with VCS2000. Average error rates between dissected value for each primal cut and VCS2000 measurement values of ham, shoulder picnic, belly, loin, and shoulder blade were around 5%. Average error rates for spare rib and tenderloin were about 10%. Correlation coefficients between the dissected value and the VCS2000 measured value for ham, shoulder picnic, loin, belly, and shoulder blade were high at 0.66-0.83. Correlation coefficients of spare rib and tenderloin were low at 0.35 and 0.47. Coefficient of determination of the VCS2000 measured value for each primal cut by regression analysis was 0.77 or more for ham, shoulder picnic, loin, and shoulder blade and 0.63 for belly. Coefficients of determination for spare rib and tenderloin were low at 0.40 and 0.27. In addition, the coefficient of determination of VCS2000 for each primal cut was higher than that of the dissected value for all primal cuts. In conclusion, pig carcass analysis using the VCS2000 has a high reliability for pork cuts with high production levels, but a relatively low reliability for pork cuts with low production levels and high fat levels.

Efficient Time-Series Similarity Measurement and Ranking Based on Anomaly Detection (이상탐지 기반의 효율적인 시계열 유사도 측정 및 순위화)

  • Ji-Hyun Choi;Hyun Ahn
    • Journal of Internet Computing and Services
    • /
    • v.25 no.2
    • /
    • pp.39-47
    • /
    • 2024
  • Time series analysis is widely employed by many organizations to solve business problems, as it extracts various information and insights from chronologically ordered data. Among its applications, measuring time series similarity is a step to identify time series with similar patterns, which is very important in time series analysis applications such as time series search and clustering. In this study, we propose an efficient method for measuring time series similarity that focuses on anomalies rather than the entire series. In this regard, we validate the proposed method by measuring and analyzing the rank correlation between the similarity measure for the set of subsets extracted by anomaly detection and the similarity measure for the whole time series. Experimental results, especially with stock time series data and an anomaly proportion of 10%, demonstrate a Spearman's rank correlation coefficient of up to 0.9. In conclusion, the proposed method can significantly reduce computation cost of measuring time series similarity, while providing reliable time series search and clustering results.

A study on the Menstrual Pain and Dysmenorrhea, Factors Influenced to Them, and Self-Management Method for Them of College Students (일부 여대생의 생리통 및 월경곤란증과 그 관련요인에 관한 조사연구)

  • Han Sun-Hee;Hur Myung-Haeng
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.5 no.2
    • /
    • pp.359-375
    • /
    • 1999
  • This is a survey in order to provide basic information about menstrual pain management and dysmenorrhea management. Menstrual pain means low abdominal cramps during menstruation and dysmenorrhea means low abdominal pains, and other symtoms as lumbago, fatigue, G-I symptoms, etc. The purposes of this study were (1) to measure the menstrual pain and dysmenorrhea, (2) to determine factors influenced to them, and (3) to know self-management method for them of college students. The subject of this study consisted of 312 college students Data were collected by questionnaire which was to measure the menstrual pain(Visual Analogue Scale(VAS), dysmenorrhea (dysmenorrhea scale) and general informations from May to June, 1999. The results of this study were as follows ; (1) Mean age for subjects was 19.4 yrs, their height was 161.4Cm, weight, 50.9Kg, menarcheal age, 13.5yrs, menstural period, 30.1 days, and menstrual duration was 5.6 days. Most respondents replied that their menstrual bleeding was moderate (72.1%) and occured regularly(55.4%). (2) Mean menstrual pain was 5.20. Menstrual pain didn't be occured 17.4 % of respondents, periodically 46.0%, and intermittently 36.6%, most commonly beginning the first day of menstruation (3) Chief management method was endurance (40.4%), use of analgesics (29.5%) and bed rest(16.5%). (4) Factors influenced to menstrual pain were analgesics use, heavy bleeding, time of menstrual pain, life change during menstruation. (5) Most symptoms of dysmenorrhea were low abdominal pain(22.2%), lumbago (15.9%), fatigue(9.0%). (6) Factors influenced to dysmenorrhea were anlgesics use and menstrual pain. (7) By Pearson's correlation analysis, there was a significant correlation between menstrual pain and menarcheal age, menstrual period. menstrual duration. But there was no correlation between menstrual pain and height, weight (8) By Pearson's correlation analysis, there was a significant correlation between dysmenorrhea and menstrual period But there was no correlation between menstrual pain and menarcheal age, menstrual duration, height, weight The results demonstrate the importance of development and clinical trial of nursing intervention on menstrual pain and dysmenorrhea.

  • PDF