• Title/Summary/Keyword: correction methods

Search Result 2,007, Processing Time 0.025 seconds

Short Segment Anterior Correction of Adolescent Idiopathic Scoliosis

  • Han, In-Ho;Chin, Dong-Kyu;Kim, Keun-Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.1
    • /
    • pp.52-56
    • /
    • 2008
  • Objective : The purpose of this study was to introduce our surgical experiences of scoliosis and to evaluate the effectiveness of anterior correction and fusion in adolescent idiopathic scoliosis (AIS). Methods : Between August 2004 and August 2007, four patients with AIS were treated with anterior segmental fusion and fixation at our hospital. Mean follow-up period was 9 (6-12) months. The average age was 14.0 (13-15) years. According to Lenke classification, three patients showed Lenke 1 curve and one patient with Lenke 5 curve. Single rod instrumentation was performed in one patient, dual rod instrumentation in one patient and combined rod instrumentation in two patients. Coronal Cobb measurements were performed on all curves in thoracic, thoracolumbar and, lumbar spine and the angle of hump was measured by a scoliometer pre- and postoperatively. Results : The average operative time was 394 minutes (255-525) with an average intraoperative blood loss of 1,225 ml (1,000-1,700). The mean period of hospital stay was 19.3 days and there was no complication related to the surgery. The mean Cobb angle was reduced from $43.3^{\circ}$ to $14.8^{\circ}$ (65.8% correction) postoperatively and the rib hump corrected less than $5^{\circ}$. All patients and their parents were satisfied with the deformity correction. Conclusion : Anterior spinal correction and fusion of AIS with Lenke 1 and 5 curve showed excellent deformity correction without any complications. In particular, we recommend anterior dual rod instrumentation because of mechanical stability, better control of kyphosis, and a higher fusion rate.

Distortion Correction in Magnetic Resonance Images on the Measurement of Muscle Cross-sectional Area (자기공명영상을 이용한 근육 단면적 측정법의 활용을 위한 영상왜곡보정)

  • Hong, Cheol-Pyo;Lee, Dong-Hoon;Park, Ji-Won;Han, Bong-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.66-72
    • /
    • 2012
  • Purpose: The purpose of this study is to explore the importance of the image distortion correction in the cross sectional area measurement for the iliopsas muscle, tensor fasciae latae muscle, gluteus maximus muscle and the knee extensor muscles, by using (magnetic resonance imaging) MRI. Methods: This study was performed using an open 0.32T MRI system. To estimate the image distortion, T1 images for an AAPM homogeneity/linearity phantom were acquired, and the region in which the maximum geometric distortion was less than or equal to the pixel size (1.6 mm) of the images, it was defined as the distortion correction-free region. The T2 images for a human subject's pelvis and thigh in normal positions were obtained. Then, after the regions of interest in the pelvis and thigh were moved into the distortion correction-free region, T2 images for the pelvis and thigh were scanned with the same imaging parameters used in the previous T2 imaging. The cross-sectional areas were measured in the two T2 images that were obtained in the normal position, and the distortion correction-free region, as well as the area error caused by geometric image distortion was calculated. Results: The geometrical distortion is gradually increased, from the magnet center to the outer region, in axial and coronal plane. The cross-sectional area error of gluteus maximus muscle and the knee extensors was as high as 9.27% and 3.16% in before and after distortion correction, respectively. Conclusion: The cross-sectional area of the muscles that suffered from the geometrical distortion is necessary to correct for the estimation of the intervention.

Evaluation of Analytical Method for Detent Spring Force Correction (디텐트 스프링 교정을 위한 해석적방법의 적용성 평가)

  • Kim, Sun-Ho;Kwon, Hyuk-Hong;Park, Kyoung-Taik;Jung, Yong-Hun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.4 s.97
    • /
    • pp.57-63
    • /
    • 1999
  • A thin metal plate such as detent spring has the shape deformation due to the phenomenon of spring back after press machining and heat treatment process. This requires the correction of spring shape and force in final inspection process. To do correction of the shape deformation the impact force is manually applied to the bended part of detent spring after measuring the shape deformation and spring force. To develop the automatic spring force correction system, applied force of occurring plastic deformation must be derived from the experimental method. But frequent change of spring shape and material makes it difficult to accomplish the experimental method to be applied. This paper describes the analytical method for detent spring force correction system is to be substituted for the experimental method. FEM(Finite Element Method) is used to find the boundary value between elastic and plastic deformation in the analytical method. To confirm the validity of the analytical method, the result of two methods is compared each other at various applied force conditions. It shows that the simulation result of the analytical method is consistent with the result of the experimental method within the error bound ${\pm}$5%. The result of this paper is useful for development of the automatic spring correction system and reduction of the complicated and tedious processes involved in experimental method.

  • PDF

Effects of Posture Correction Exercise on Muscle Activity and Onset Time during Arm Elevation in Subject with Forward Head and Rounded Shoulder Posture

  • Park, Sun-Wook;Lee, Han-Suk
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.3
    • /
    • pp.29-41
    • /
    • 2020
  • PURPOSE: The aim of this study was to provide evidence for the treatment of Forward Head and Rounded Shoulder Posture (FHRSP) using posture correction exercises by comparing muscle activity and onset time around the neck and shoulder area during an arm elevation task. METHODS: The subjects were divided into FHRSP (21 persons) and non-FHRSP (19 persons) groups to measure muscle activity and onset time of muscle contraction. Wireless surface electromyography was used to assess the muscle activity and onset time of the right and left sternocleidomastoid (SCM), splenius capitis, anterior deltoid, middle deltoid, serratus anterior, upper trapezius, pectoralis major, and infraspinatus during an arm elevation task. After the pre-measurement, the participants performed the postural correction exercises, and then the post-measurement was conducted. RESULTS: After the posture correction exercises, there were significant differences in the muscle activity and onset time of all muscles in the FHRSP group. The results of the comparison of the muscle onset time during an arm elevation task demonstrated that after the postural correction exercises, the muscle onset time was significantly reduced in the right and left SCM and left splenius capitis, but there were no significant changes in the onset time of other muscles. CONCLUSION: The results of this study help us understand the change in muscle activities and muscle contraction onset time in a person with FHRSP when lifting the arm and suggest the relevant basis to apply the posture correction exercise in clinical settings.

Development of Automatic Inspection System for ALC Block Using Distortion Correction Technique (왜곡 보정 기법을 이용한 ALC 블럭의 자동 검사 시스템 개발)

  • Han, Kwang-Hee;Huh, Kyung-Moo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • The lens distortion in the machine vision system is inevitable phenomenon. Distortion is getting worse, due to the selection of lens in the trend of reducing prices and size of the system. In this trend, the distortion correction becomes more important. But, the traditional correction methods has problems, such as complexity and requiring more operations. Effective distorted digital image correction is the precondition of target detection and recognition based on vision inspection. To overcome the disadvantage of traditional distortion correction algorithms, such as complex modeling, massive computation and marginal information loss, an image distortion correction algorithm based on photogrammetry method is proposed in this paper. In our method, we use the lattice image as the measurement target. Through the experimental results, we could find that we can reduce the processing time by 4ms. And also the inspection failure rate of our method was reduced by 2.3% than human-eyes inspection method.

A Correction of Color Temperature and Consistency for 3D Stereoscopic Images (3D 입체영상을 위한 색온도와 색 일치 보정)

  • Kim, Jeong-Yeop;Kim, Sang-Hyun
    • The KIPS Transactions:PartB
    • /
    • v.18B no.3
    • /
    • pp.139-146
    • /
    • 2011
  • The color correction is the important process of influencing on the picture quality of the 3D stereoscopic images. Existing colorcorrecting methods handle the processing intensifying a correspondence among a left and right image using a histogram based on any one side. In case of color correction based on a histogram, it is difficult to correct tone of image, because the color temperature is not converted enough. And in this paper, the color temperature correction and color consistency correction is proposed without using histogram. The proposed color correction method by color temperature gives 3 in CIE-${\Delta}E$ for each pixel on the images captured with same illuminants and the conventional gives similar results. For color consistency, the proposed gives 9 in CIE-${\Delta}E$ on the images captured with different illuminants while the conventional gives 18. The proposed method shows better results than the conventional in color consistency processing.

Comparison of Hemoglobin Correction Effects According to Storage Period and Other Factors in the Transfusion of Packed Red Blood Cells in Neonatal Intensive Care Unit Patients

  • Park, Ji Hyun;Kong, Seom Gim;Hong, Yoo Rha
    • Neonatal Medicine
    • /
    • v.25 no.4
    • /
    • pp.170-177
    • /
    • 2018
  • Purpose: Preterm infants frequently require red blood cell (RBC) transfusions in neonatal intensive care units (NICU). Storage RBCs undergo many changes during storage periods. We aimed to compare the hemoglobin (Hb) correction effect according to the period of RBC storage and investigate the factors influencing Hb correction. Methods: This retrospective study reviewed the medical records of 289 patients who received RBC transfusion more than once in the NICU of Kosin University Gospel Hospital between February 2006 and March 2016. The subjects were classified into two storage groups: short-term (${\leq}7days$, n=88) and long-term (>7 days, n=201), according to the period of RBC storage. We checked Hb levels by complete blood cell count tests conducted within 2 days before and 5 to 9 days after the first transfusion. We compared the Hb difference between the two groups and analyzed the factors influencing Hb correction. Results: Excluding the use of an invasive ventilator, there was no significant difference between the two groups in terms of clinical characteristics. There was no significant difference in the Hb correction effect between the two groups (P=0.537). Birth weight greater than 1,500 g, higher weight at transfusion, and larger volume of transfusion were significant prognostic factors affecting greater changes in Hb. In addition, surgery experience, higher Hb level at transfusion, and additional blood tests were found to be significantly associated with less changes in Hb. Conclusion: The RBC storage period did not affect the Hb correction effect. The Hb correction effect may be diminished in infants with lower birth weight and lower weight at transfusion under unstable clinical conditions.

Evaluation of GSICS Correction for COMS/MI Visible Channel Using S-NPP/VIIRS

  • Jin, Donghyun;Lee, Soobong;Lee, Seonyoung;Jung, Daeseong;Sim, Suyoung;Huh, Morang;Han, Kyung-soo
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.1
    • /
    • pp.169-176
    • /
    • 2021
  • The Global Space-based Inter-Calibration System (GSICS) is an international partnership sponsored by World Meteorological Organization (WMO) to continue and improve climate monitoring and to ensure consistent accuracy between observation data from meteorological satellites operating around the world. The objective for GSICS is to inter-calibration from pairs of satellites observations, which includes direct comparison of collocated Geostationary Earth Orbit (GEO)-Low Earth Orbit (LEO) observations. One of the GSICS inter-calibration methods, the Ray-matching technique, is a surrogate approach that uses matched, co-angled and co-located pixels to transfer the calibration from a well calibrated satellite sensor to another sensor. In Korea, the first GEO satellite, Communication Ocean and Meteorological Satellite (COMS), is used to participate in the GSICS program. The National Meteorological Satellite Center (NMSC), which operated COMS/MI, calculated the Radiative Transfer Model (RTM)-based GSICS coefficient coefficients. The L1P reproduced through GSICS correction coefficient showed lower RMSE and Bias than L1B without GSICS correction coefficient applied. The calculation cycles of the GSICS correction coefficients for COMS/MI visible channel are provided annual and diurnal (2, 5, 10, 14-day), but long-term evaluation according to these cycles was not performed. The purpose of this paper is to perform evaluation depending on the annual/diurnal cycles of COMS/MI GSICS correction coefficients based on the ray-matching technique using Suomi-NPP/Visible Infrared Imaging Radiometer Suite (VIIRS) data as reference data. As a result of evaluation, the diurnal cycle had a higher coincidence rate with the reference data than the annual cycle, and the 14-day diurnal cycle was the most suitable for use as the GSICS correction coefficient.

EFFICIENT COMPUTATION OF COMPRESSIBLE FLOW BY HIGHER-ORDER METHOD ACCELERATED USING GPU (고차 정확도 수치기법의 GPU 계산을 통한 효율적인 압축성 유동 해석)

  • Chang, T.K.;Park, J.S.;Kim, C.
    • Journal of computational fluids engineering
    • /
    • v.19 no.3
    • /
    • pp.52-61
    • /
    • 2014
  • The present paper deals with the efficient computation of higher-order CFD methods for compressible flow using graphics processing units (GPU). The higher-order CFD methods, such as discontinuous Galerkin (DG) methods and correction procedure via reconstruction (CPR) methods, can realize arbitrary higher-order accuracy with compact stencil on unstructured mesh. However, they require much more computational costs compared to the widely used finite volume methods (FVM). Graphics processing unit, consisting of hundreds or thousands small cores, is apt to massive parallel computations of compressible flow based on the higher-order CFD methods and can reduce computational time greatly. Higher-order multi-dimensional limiting process (MLP) is applied for the robust control of numerical oscillations around shock discontinuity and implemented efficiently on GPU. The program is written and optimized in CUDA library offered from NVIDIA. The whole algorithms are implemented to guarantee accurate and efficient computations for parallel programming on shared-memory model of GPU. The extensive numerical experiments validates that the GPU successfully accelerates computing compressible flow using higher-order method.