• Title/Summary/Keyword: correction methods

Search Result 1,993, Processing Time 0.022 seconds

New Imaging Techniques in Myocardial Perfusion SPECT (심근 관류 SOECT의 새로운 방법)

  • Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.1-9
    • /
    • 1998
  • Gated myocardial SPECT and attenuation correction gave birth to new insights into the pathophysiology of ischemic myocardial perfusion and function in clinical routine practice. Gated myocardial Tc-99m-compound SPECT improved diagnostic accuracy of coronary artery disease and enabled us to observe motion and thickening of myocardial walls as well as myocardial perfusion at the same time. Quantitative and qualitative assessment of myocardial performance and perfusion let us to understand the myocardial physiology in ischemia and infarction. In every patient who underwent gated perfusion SPECT, we will find ejection fraction, left ventricular volumes and regional wall motion. There are hopes to use gated TI-201 SPECT for the same purpose and to use gated SPECT for evaluation of wall motion and thickening at stress or immediate post-stress. Attenuation correction could improve diagnostic accuracy mainly by increasing normalcy ratio or performance of non-expert physicians. Both gated methods and attenuation correction improved specificity of non-expert physicians in diagnosing patients with moderate pretest likelihood. New imaging techniques will fill the desire of cardiologists to examine function and perfusion, and possibly metabolism in their clinical routine practice.

  • PDF

Distortion Correction Modeling Method for Zoom Lens Cameras with Bundle Adjustment

  • Fang, Wei;Zheng, Lianyu
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.140-149
    • /
    • 2016
  • For visual measurement under dynamic scenarios, a zoom lens camera is more flexible than a fixed one. However, the challenges of distortion prediction within the whole focal range limit the widespread application of zoom lens cameras greatly. Thus, a novel sequential distortion correction method for a zoom lens camera is proposed in this study. In this paper, a distortion assessment method without coupling effect is depicted by an elaborated chessboard pattern. Then, the appropriate distortion correction model for a zoom lens camera is derived from the comparisons of some existing models and methods. To gain a rectified image at any zoom settings, a global distortion correction modeling method is developed with bundle adjustment. Based on some selected zoom settings, the optimized quadratic functions of distortion parameters are obtained from the global perspective. Using the proposed method, we can rectify all images from the calibrated zoom lens camera. Experimental results of different zoom lens cameras validate the feasibility and effectiveness of the proposed method.

Realtime Implementation Method for Perspective Distortion Correction (원근 왜곡 보정의 실시간 구현 방법)

  • Lee, Dong-Seok;Kim, Nam-Gyu;Kwon, Soon-Kak
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.4
    • /
    • pp.606-613
    • /
    • 2017
  • When the planar area is captured by the depth camera, the shape of the plane in the captured image has perspective projection distortion according to the position of the camera. We can correct the distorted image by the depth information in the plane in the captured area. Previous depth information based perspective distortion correction methods fail to satisfy the real-time property due to a large amount of computation. In this paper, we propose the method of applying the conversion table selectively by measuring the motion of the plane and performing the correction process by parallel processing for correcting perspective projection distortion. By appling the proposed method, the system for correcting perspective projection distortion correct the distorted image, whose resolution is 640x480, as 22.52ms per frame, so the proposed system satisfies the real-time property.

Dehazing in HSI Color Space with Color Correction (HSI 색 공간 색상 보정을 이용한 안개 제거 알고리즘)

  • Um, Taeha;Kim, Wonha
    • Journal of Broadcast Engineering
    • /
    • v.18 no.2
    • /
    • pp.140-148
    • /
    • 2013
  • The haze removal algorithm using median dark channel prior is an efficient and fast method with relatively accurate transmission estimation. However, conventional methods may produce color distortion since the method ignores the color mismatch between estimated airlight and actual airlight. In this paper, we propose a color correction with measuring color fidelity in the HSI color space. Experimental results show that the proposed algorithm gives better color correction scheme.

Hybrid Linear Analysis Based on the Net Analyte Signal in Spectral Response with Orthogonal Signal Correction

  • Park, Kwang-Su;Jun, Chi-Hyuck
    • Near Infrared Analysis
    • /
    • v.1 no.2
    • /
    • pp.1-8
    • /
    • 2000
  • Using the net analyte signal, hybrid linear analysis was proposed to predict chemical concentration. In this paper, we select a sample from training set and apply orthogonal signal correction to obtain an improved pseudo unit spectrum for hybrid least analysis. using the mean spectrum of a calibration training set, we first show the calibration by hybrid least analysis is effective to the prediction of not only chemical concentrations but also physical property variables. Then, a pseudo unit spectrum from a training set is also tested with and without orthogonal signal correction. We use two data sets, one including five chemical concentrations and the other including ten physical property variables, to compare the performance of partial least squares and modified hybrid least analysis calibration methods. The results show that the hybrid least analysis with a selected training spectrum instead of well-measured pure spectrum still gives good performances, which is a little better than partial least squares.

Procedural Geometry Calibration and Color Correction ToolKit for Multiple Cameras (절차적 멀티카메라 기하 및 색상 정보 보정 툴킷)

  • Kang, Hoonjong;Jo, Dongsik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.4
    • /
    • pp.615-618
    • /
    • 2021
  • Recently, 3D reconstruction of real objects with multi-cameras has been widely used for many services such as VR/AR, motion capture, and plenoptic video generation. For accurate 3D reconstruction, geometry and color matching between multiple cameras will be needed. However, previous calibration and correction methods for geometry (internal and external parameters) and color (intensity) correction is difficult for non-majors to perform manually. In this paper, we propose a toolkit with procedural geometry calibration and color correction among cameras with different positions and types. Our toolkit consists of an easy user interface and turned out to be effective in setting up multi-cameras for reconstruction.

True coincidence summing correction factor for point source geometry with PHITS

  • Esra Uyar
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4472-4476
    • /
    • 2023
  • In this study, it has been shown that the true coincidence summing correction factor can be obtained for the first time using the PHITS Monte Carlo program. Determining this correction factor using different methods and tools in each laboratory to increase the possibility of achieving high-efficiency measurement conditions is still popular in gamma-ray spectrometry. By using 133Ba, 152Eu, 134Cs, and 60Co point sources, the true coincidence summing factor was investigated in both near and far counting geometries for 15 different energy values. GESPECOR software was used to validate the results obtained with PHITS. A remarkable agreement was obtained between PHITS and GESPECOR, with a discrepancy of less than 3%. With this study, a new tool has been proposed to obtain the true coincidence summing factor, which is one of the significant correction factors investigated/calculated in gamma-ray spectrometric studies.

Effects of Nerve Mobilization Exercise and Scapula Postural Correction Exercise for Adhesive Capsulitis Patients (신경가동운동과 견갑골 자세교정운동이 오십견 환자에게 미치 는 영향)

  • Jung, Min-keun;Kim, Yu-ri;Kim, Wan-ki;Jeon, Jae-guk
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.24 no.1
    • /
    • pp.57-65
    • /
    • 2018
  • Background: This study examined the effects of nerve mobilization exercise and scapula postural correction exercise and scapula postural correction exercise after applying conservative physical therapy to frozen shoulder. Methods: Thirty-four outpatients were divided into a nerve mobilization exercise and scapula postural correction exercise group and scapula postural correction exercise group. Each group performed its own exercise 30 minutes per day, three times per week, for 6 weeks. Pain intensity was measured by the visual analogue scale. Range of motion was measured by the goniometer. The scapular position was measured by scapular index. Grasping power was measured by the Grip Track Commander. Measurements were made at baseline and six weeks after the intervention. Results: the visual analogue scale, range of motion (except lateral rotation), and grasping power for each group showed significant changes at baseline and six weeks after the intervention (p<.05). Significant differences were also evident between the two groups for these three measurements (p<.05). Conclusions: Nerve mobilization exercise & scapula postural correction exercise is more effective than scapula postural correction exercise for reducing pain intensity and increasing grasping power, scapular index and range of motion (except lateral rotation) in frozen shoulder syndrome patients.

Incomplete Reduction that Influence Reduction of Sesamoid as a Cause for Recurrence of Hallux Valgus (무지 외반증 재발의 한 원인으로 생각되는 종자골 정복에 영향을 주는 인자)

  • Yune, Young-Phil;Lee, Chul-Hyung;Jeong, Hyun-Yoon;Kim, Young-Woo;Jung, Jae-Yong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.1
    • /
    • pp.21-24
    • /
    • 2010
  • Purpose: The incomplete reduction of the sesamoid has lately been issued as cause for recurrence. In this study, we analysed factors that may influence reduction of sesamoid. Materials and Methods: The study consists of 50 cases operated by single surgeon. Eighteen cases were done by proximal chevron osteotomy, and 32 cases were done by scarf osteotomy. Hallux valgus (HV) angle and intermetatarsal (IM) angle were measured before and three months after the surgery. Sesamoid position (SP) was classified according to Hardy and Clapham grade system. Results: After the proximal chevron osteotomy, the correction of the mean HV angle was $19.5^{\circ}$, and IM angle was $6.2^{\circ}$. SP was changed from 5.6 to 3.4 grade. After the Scarf osteotomy, the correction of the mean HV angle was 25 degree, and IM angle was $9^{\circ}$. SP was changed from 5.5 to 2.8 grade. There was difference of sesamoid's correction between two different method of surgery (p=0.127). However, better correction of sesamoid was witnessed with bigger correction angle regardless of method of surgery (p=0.002, 0.001). Conclusion: We believe surgical method do not effect sesamoid's correction but more correction angle can result in better correction of sesamoid position.

Compensation Methods for Non-uniform and Incomplete Data Sampling in High Resolution PET with Multiple Scintillation Crystal Layers (다중 섬광결정을 이용한 고해상도 PET의 불균일/불완전 데이터 보정기법 연구)

  • Lee, Jae-Sung;Kim, Soo-Mee;Lee, Kwon-Song;Sim, Kwang-Souk;Rhe, June-Tak;Park, Kwang-Suk;Lee, Dong-Soo;Hong, Seong-Jong
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.52-60
    • /
    • 2008
  • Purpose: To establish the methods for sinogram formation and correction in order to appropriately apply the filtered backprojection (FBP) reconstruction algorithm to the data acquired using PET scanner with multiple scintillation crystal layers. Materials and Methods: Formation for raw PET data storage and conversion methods from listmode data to histogram and sinogram were optimized. To solve the various problems occurred while the raw histogram was converted into sinogram, optimal sampling strategy and sampling efficiency correction method were investigated. Gap compensation methods that is unique in this system were also investigated. All the sinogram data were reconstructed using 20 filtered backprojection algorithm and compared to estimate the improvements by the correction algorithms. Results: Optimal radial sampling interval and number of angular samples in terms of the sampling theorem and sampling efficiency correction algorithm were pitch/2 and 120, respectively. By applying the sampling efficiency correction and gap compensation, artifacts and background noise on the reconstructed image could be reduced. Conclusion: Conversion method from the histogram to sinogram was investigated for the FBP reconstruction of data acquired using multiple scintillation crystal layers. This method will be useful for the fast 20 reconstruction of multiple crystal layer PET data.