• Title/Summary/Keyword: corrected of axis

Search Result 82, Processing Time 0.02 seconds

Effect of Under and Over Refractive Correction on Visual Acuity Performance using Two Different Charts

  • Chen, Ai-Hong;Shah, Siti Salwa Mohamad;Rosli, Saiful Azlan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.291-295
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate the effect of under and over refractive correction on visual acuity performance and the variation of the visual performance measurement using two different visual acuity charts. Methods: Ten young adults, aged between 19 and 25 years old, were recruited. Inclusion criteria: no history of ocular injury or pathology with a best-corrected visual acuity of 6/6 on dominant eye. The over and under refractive corrections were induced using minus and plus spherical ophthalmic lenses in 0.50 D steps up to 3.00 D; as well as using three axis orientations of cylindrical ophthalmic lenses ($45^{\circ}$, $90^{\circ}$ and $180^{\circ}$) in 0.50 D steps. The variation of visual acuity performance measurements was investigated using Bailey-Lovie LogMAR chart and Landolt C chart. Results: The visual acuity changes with lenses were significantly different between two charts [F = 49.15, p < 0.05 with plus spherical ophthalmic lenses and F = 174.38, p < 0.05 with minus spherical ophthalmic lenses]. The visual acuity changes with three different cylindrical axis showed no significant difference between Bailey-Lovie LogMAR chart [F = 2.35, p > 0.05] and Landolt C chart [F = 3.12, p = 0.05]. Conclusions: The over and under refractive correction affected the visual acuity performance differently. The Landolt C chart and Bailey-Lovie LogMAR chart demonstrated variation in measurements.

Coincidence Summing Corrections in HPGe Gamma Ray Spectrometry in Marinelli-beakers with Efficiency (효율을 적용한 마리넬리 비이커에서 HPGe 감마선 분광분석법의 동시합성보정)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.557-563
    • /
    • 2018
  • Coincidence summing correction effects are known to be greater as the efficiency of the detector increases and as the distance between the source and the detector increases. A point source($^{60}Co$) was used to vary the distance in the direction of the detector's center axis and in the radial direction to obtain the P/T ratio for Coincidence summing correction calibration. In this study, values for coincidence summing corrected calibration of the values in the central and radial directions were applied to the mixed volume source(450 ml CRM source) to compare the overall peak efficiency change according to P/T with Geant4. In addition, the efficiency obtained from the mapping method is applied to the seaweed, a marine sample, and the compatibility of the P/T ratio with the detector and sample very dose together. The efficiency corrected to 1,836 keV was applied to the energy zone affected by the efficiency of 500 keV and the relative error of the measured and corrected values was well matcched by the 3.2 % peak efficiency correction. As with 450 mL CRM source, the larger the volume, the lower the P/T ratio was by ${\pm}5%$. This is due to the increased scattering of gamma-rays emitted as the source becomes farther away from the detector, and this change in P/T has been confirmed to affect the Coincidence summing corrected peak efficiency.

A CASE REPORT OF AMELOBLASTOMA OF THE MANDIBLE (하악골에 발생한 Ameloblastoma의 증례)

  • Kim, Suk-Hwan
    • The Journal of the Korean dental association
    • /
    • v.16 no.4 s.107
    • /
    • pp.279-282
    • /
    • 1978
  • A girl aged 16 years and I month, had a severe Angle's class III malocclusion, characterized by a retarded and constricted maxilla, anterior and posterior crossbite. This patient underwent extraction of two lower Ist premolar. After extraction, author placed multibanded system in lower dental arch to change the long axis of anterior teeth and delivered removable appliance with Coffin spring in the upper dental arch to expand dental arch. After 13 months, anterior & posterior crossbite was corrected and this patient's profile was improved. Superimposition of pretreatment and posttreatment cephalograms upon the SN line registered at S showed backward downward rotation of the mandible and retrusion of lower lip.

  • PDF

A CASE REPORT OF SEVERE ANGLE'S CLASS III MALOCCLUSION (심한 Angle씨 III급 부정교합의 치험예)

  • Sung, Jae-Hyun
    • The Journal of the Korean dental association
    • /
    • v.16 no.4 s.107
    • /
    • pp.273-278
    • /
    • 1978
  • A girl aged 16 years and I month, had a severe Angle's class III malocclusion, characterized by a retarded and constricted maxilla, anterior and posterior crossbite. This patient underwent extraction of two lower Ist premolar. After extraction, author placed multibanded system in lower dental arch to change the long axis of anterior teeth and delivered removable appliance with Coffin spring in the upper dental arch to expand dental arch. After 13 months, anterior & posterior crossbite was corrected and this patient's profile was improved. Superimposition of pretreatment and posttreatment cephalograms upon the SN line registered at S showed backward downward rotation of the mandible and retrusion of lower lip.

  • PDF

A Wafer Alignment Method and Accuracy Evaluation (웨이퍼 정렬법과 정밀도 평가)

  • Park, Hong-Lae;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.9
    • /
    • pp.812-817
    • /
    • 2002
  • This paper presents a development of high accuracy aligner and describes a method to find the orientation of a substantially circular disk shaped wafer with at least one flat region on an edge thereof. In the developed system, the wafer is spun one 360 degree turn on a chuck and the edge position is measured by a linear array to obtain a set of data points at various wafer orientation. The rotation axis may differ from wafer center by an unknown eccentricity. The flat angle is found by fitting a cosine curve to the actual data to obtain a deviation. The maximum deviation is then corrected for errors due to a finite number of data points and wafer eccentricity by calculating an adjustment angle from data points on the wafer fiat. After determining the flat angle the wafer is spun to the desired orientation. The wafer eccentricity can be calculated from four of the data points located away from the flat edge region. and the wafer is then centered.

Physical Parmeters of Late Type Spiral Galaxies - II. Surface Brightness Distribution of NGC 7793

  • Kim, Chang-Ha;Chun, Mun-Suk
    • Journal of Astronomy and Space Sciences
    • /
    • v.3 no.1
    • /
    • pp.53-66
    • /
    • 1986
  • Isophotes and surface brightness distribution were obtained for the late type normal spiral galaxy NGC 7793 (morphological type SA(s)d) which is one of the Sculptor group. The calculated total luminosity $M_{T}$ is obtained as 9.44 and the corrected face on magnitude ${B_T}^{circ}$ is 9.10. The revised distance to this galaxy $\Delta$=3.1 Mpc (de Vaucouleurs and Davoust 1980) is used for calculating the absolute magnitude ${M_T}^{circ}$ = -18.36. From the isophotes, the position angle to the major axis is $101^{circ}$, the mean axial ratio is q=b/a =0.65, and the inclination is i=50$^{circ}$. The concentric indices $C_{21}$=1069 and $C_{32}$ =1.50 are well agreed to the average value of Sd type galaxies.

  • PDF

Sub-micron Control Algorithm for Grinding and Polishing Aspherical Surface

  • Kim, Hyung-Tae;Yang, Hae-Jeong;Kim, Sung-Chul
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.3
    • /
    • pp.386-393
    • /
    • 2008
  • A position control method for interpolating aspherical grinding and polishing tool path was reviewed and experimented in a nano precision machine. The position-base algorithm was reformed from the time-base algorithm, proposed in the previous study. The characteristics of the algorithm were in the velocity control loop with position feedback. The aspherical surface was divided by an interval at which each velocity and acceleration were calculated. The theoretical velocity was corrected by position error during processing. In the experiment, a machine was constructed and nano-scale linear encoders were installed at each axis. Relation between process parameters and the variation of position error was monitored and discussed. The best result from optimized parameters showed that the accuracy was 150nm and improved from the previous report.

On Error Modeling and Compensation of Machine Tools (공작기계 오차 모델링과 보정에 관한 연구)

  • Song, Il-Gyu;Choi, Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.1
    • /
    • pp.98-107
    • /
    • 1996
  • The use of composite hyperpatch model is proposed to predict a machine tool positional error over the entire work space. This is an appropriate representation of the distorted work space. This model is valid for any configuration of 3-axis machine tool. Tool position, which is given NC data or CL data, contains error vector in actual work space. In this study, off-line compensation scheme was investigated for tool position error due to inaccuracy in machine tool structure. The error vector in actual work space is corrected by the error model using Newton-Raphson method. The proposed error compensation method shows the possibility of improving machine accuracy at a low cost.

  • PDF

Control Method for the Tool Path in Aspherical Surface Grinding and Polishing

  • Kim, Hyung-Tae;Yang, Hae-Jeong;Kim, Sung-Chul
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.7 no.4
    • /
    • pp.51-56
    • /
    • 2006
  • This paper proposes a control algorithm, which is verified experimentally, for aspherical surface grinding and polishing. The algorithm provides simultaneous control of the position and interpolation of an aspheric curve. The nonlinear formula for the tool position was derived from the aspheric equation and the shape of the tool. The function was partitioned at specific intervals and the control parameters were calculated at each control section. The position, acceleration, and velocity at each interval were updated during the process. A position error feedback was introduced using a rotary encoder. The feedback algorithm corrected the position error by increasing or decreasing the feed speed. In the experimental verification, a two-axis machine was controlled to track an aspherical surface using the proposed algorithm. The effects of the control and process parameters were monitored. The results demonstrated that the maximum tracking error with tuned parameters was at the submicron level for concave and convex surfaces.

Analysis of Axial Mis-alignment After Wearing of Toric Soft Contact Lenses (토릭소프트콘택트렌즈의 착용 후 축 정렬 상태의 변화 분석)

  • Kim, Sang-Yoeb;Lee, Dong Yeol;Lee, Sun-Haeng;Kim, Kun-Kyu;Song, Sop;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.213-217
    • /
    • 2010
  • Purpose: To emphasize the necessity of post-fitting by follow-up test, the mis-alignment was analyzed after initial wearing of toric soft contact lenses (TSCL). Methods: After trial contact lenses were worn to 87 eyes with myopic astigmatism for 1 week, we observed the alignment of axis mark on trial contact lenses using slit lamp and corrected the rotated axis by method of LARS. After final fitting, rotation ratio, rotation degree and rotation position were analyzed compared to initial prescription divided to amount of cylinderical and spherical powers. Results: Rotation ratio of TSCL's axis was increased as increment of both cylinderical powers and (-)spherical powers. An average of rotation degree was $10^{\circ}{\sim}13^{\circ}$ which was not related to amount of their powers. Rotation position of TSCL's axis was more to temporal than to nasal. Conclusions: Because mis-alignment of axis after TSCL wearing induce the poor sight, adjustment of axial alignment as a result of follow-up must be performed.