• 제목/요약/키워드: corrected of axis

검색결과 82건 처리시간 0.028초

Model Parameter Correction Algorithm for Predictive Current Control of SMPMSM

  • Li, Yonggui;Wang, Shuang;Ji, Hua;Shi, Jian;Huang, Surong
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1004-1011
    • /
    • 2016
  • The inaccurate model parameters in the predictive current control of surface-mounted permanent magnet synchronous motor (SMPMSM) affect the current dynamic response and steady-state error. This paper presents a model parameter correction algorithm based on the relationship between the errors of model parameters and the static errors of dq-axis current. In this correction algorithm, the errors of inductance and flux are corrected in two steps. Resistance is ignored. First, the proportional relations between inductance and d-axis static current errors are utilized to correct the error of model inductance. Second, the flux is corrected by utilizing the proportional relations between flux and q-axis static current errors under the condition that inductance is corrected. An experimental study with a 100 W SMPMSM is performed to validate the proposed algorithm.

근시성 난시안에서 난시축 변화가 시력에 미치는 영향 (Effect of Visual acuity for Change of Astigmatism axis in Myopic astigmatism)

  • 최준규;김보연;이은희
    • 디지털융복합연구
    • /
    • 제13권12호
    • /
    • pp.285-290
    • /
    • 2015
  • 본 연구는 근시성 난시안에서 난시축의 변화에 따른 시력상태를 비교분석하고, 정확한 시력검사와 처방서에 따른 난시 교정용 안경의 조제 가공 오차를 최소화 하고자 한다. 안질환 및 전신질환이 없는 근시성 난시를 가지고 있는 남 녀 93명(186안)을 대상자로 선정하였다. 완전교정상태에서 난시축의 $5^{\circ}$, $10^{\circ}$, $15^{\circ}$ 변화하였을 때의 시력을 비교하였다. 난시의 종류는 186안 중에서 중에서 직난시의 비율이 가장 높았다. 1.0으로 완전교정시 난시축의 변화에 따른 시력의 변화는 난시축 변화가 크면 클수록 시력이 감소하는 것으로 나타났다. 난시의 형태는 연령의 증가와 함께 직난시에서 도난시로 바뀌는 것을 알 수 있었으며, 난시의 교정축 변화가 클수록 교정시력은 떨어지는 것으로 나타났다. 난시의 굴절검사를 실시할 때는 난시도수와 난시축을 정확히 검사하고 교정하는 것이 융합되어야 할 것이다.

Optical System Design for a Head-up Display Using Aberration Analysis of an Off-axis Two-mirror System

  • Kim, Byung-Hyun;Park, Sung-Chan
    • Journal of the Optical Society of Korea
    • /
    • 제20권4호
    • /
    • pp.481-487
    • /
    • 2016
  • This study presents a new optical system for a combiner-type head-up display (HUD) with a cylindrical lens as an asymmetrical aberration corrector, instead of a freeform mirror. In the initial design process based on off-axial aberration analysis, we obtain an off-axis two-mirror system corrected for linear astigmatism and spherical aberration by adding a conic secondary mirror to an off-axis paraboloidal mirror. Thus, since the starting optical system for an HUD is corrected for dominant aberrations, it enables us to balance the residual asymmetrical aberrations with a simple optical surface such as a cylinder, not a complex freeform surface. From this design process, an optical system for an HUD having good performance is finally obtained. The size of the virtual image is 10 inches at 2 meters away from a combiner, and the area of the eye box is 130×50 mm2.

난시안의 교정축 이탈과 교정시력과의 관계 연구 (A Study on the Relationship Between the Off-Axis Cylinder and Corrected Vision of Astigmatism)

  • 김정희;강수아
    • 한국안광학회지
    • /
    • 제12권3호
    • /
    • pp.83-87
    • /
    • 2007
  • 본 연구는 안질환이 없고 양안시 기능이 정상인 20대에서 50대 사이의 근시성 난시를 가지고 있는 남, 녀 대학생 57명(114 eye)을 대상으로 난시안의 굴절이상도를 완전교정한 상태에서 교정축 만을 $5^{\circ}$, $10^{\circ}$, $15^{\circ}$ 회전하여 완전교정상태와의 시력상태를 비교 분석하였다. 난시 교정안경 착용자의 30.8%가 난시축이 정확하게 교정되지 않은 안경을 착용하고 있었으며, 난시안을 정확하게 교정한 후의 시력과 난시량을 완전교정하고 교정축을 $5^{\circ}$, $10^{\circ}$, $15^{\circ}$ 이동한 시력을 비교한 결과 한 줄 이상의 시력 감소가 나타나는 눈이 각각 56.1%, 84.2%, 93.8%로 조사되었다. 교정축을 완전교정 했을 때와 축이 이탈했을 때와의 시력감소의 폭은 이탈 각도가 클수록 크다는 것을 알 수 있었으며, 난시 교정축의 이탈 각도에 따른 평균 시력변화는 완전교정 했을 때와 비교할 때 $5^{\circ}$에서는 0.94, $10^{\circ}$에서는 0.87, $15^{\circ}$에서는 0.79로 조사되었다. 또한, 완전 교정축에서 $5^{\circ}$ 이탈했을 때는 문자시표에서는 약 한 줄 정도의 시력차이가 있었고, $10^{\circ}$이탈 했을 때는 약 1.8줄 정도의 시력차이가 있었고, $15^{\circ}$ 이탈 했을 때는 약 2.6줄 정도의 차이가 발생하는 것으로 조사되었다. 즉, 난시 교정안경의 교정축이 이탈되었을 경우 시력감소가 발생하는 것을 확인할 수 있었고, 난시안의 교정축 이탈은 안정피로를 유발할 수 있으므로 시력검사 과정에서 정확한 난시축의 교정은 중요한 요소이므로 처방을 토대로 한 난시 교정안경 조제가공 후 교정축의 정확도 확인을 반드시 실시하여 축 오류를 최소화해야 한다고 사료된다.

  • PDF

CNC 공작기계용 온라인 실시간 위치오차 보정시스템의 개발 (Development of Online Realtime Positioning Error Compensation System for CNC Machine Tools)

  • 정재일;김종원;남원우;이상조
    • 한국정밀공학회지
    • /
    • 제16권10호
    • /
    • pp.45-52
    • /
    • 1999
  • The online realtime positioning error compensation system 'SKY-PACS' is developed to correct geometric errors, thermal errors and tool deflection errors induced by cutting forces on the vertical machining center. 'SKY-PACS' communicates position commands and position compensation signals with the CNC controller at 100Hz, which is CNC control frequency. So the compensation procedure can be applied during axis movement. Using 'SKY-PACS', Maximum 1 axis positioning accuracy was corrected from 5{\mu}m$ to 2{\mu}m$and the squareness error of X-Y table was corrected from 51{\mu}m$/m to below 4{\mu}m$/m. The error compensation under the cutting condition is carried out by ISO10791-7. And the measurement of test-pieces shows that the roundness is corrected rom 8{\mu}m$ to below 5{\mu}m$.

  • PDF

Lens Design of the Eyepiece Combined with the Accommodation-dependent Navarro Eye at an On-axis Point

  • Choi, Ka-Ul;Song, Seok-Ho;Kim, Sang-Gee
    • Journal of the Optical Society of Korea
    • /
    • 제14권1호
    • /
    • pp.55-62
    • /
    • 2010
  • We introduce a new method for lens design that combines an eyepiece with the finite model eye, to make a corrected version of the accommodation-dependent Navarro eye. The optical system that we designed, which includes a human eye, takes into account the aberration of the eye and increases the performance of the image in the retina. In the design results, for the optimized eyepiece combined with the corrected Navarro eye, visual acuity is 1.40. Compared with the existing method of eyepiece design using inverse ray tracing with the corrected Navarro eye, MTF value was recorded as 0.079 to 0.283 at 160 lp/mm and visual performance was improved.

Optical System Design and Evaluation for an Augmented Reality Head-up Display Using Aberration and Parallax Analysis

  • Kim, Kum-Ho;Park, Sung-Chan
    • Current Optics and Photonics
    • /
    • 제5권6호
    • /
    • pp.660-671
    • /
    • 2021
  • We present a novel optical system for an augmented reality head-up display (AR HUD) with two virtual images at different conjugates by employing a confocal off-axis two-mirror and introducing the horopter circle. For a far virtual image with large asymmetrical aberrations, we initially obtain an off-axis two-mirror system corrected for these aberrations and compensated for the down angle by configuring its parameters to satisfy the confocal and Scheimpflug conditions, respectively. In addition, this system is designed to reduce the biocular parallax by matching Petzval surface into the longitudinal horopter circle in a near virtual image. This design approach enables us to easily balance the residual aberrations and biocular parallax when configuring the optical system with two different conjugates, which results in an AR HUD available for near and far virtual images together.

고에너지 선형가속기의 Independent Collimator를 이용한 비대칭 방사선 조사시 방사선량 결정에 미치는 요인에 관한 연구 (Dosimetric Characteristics of Dual Photon Energy Using Independent Collimator Jaws)

  • 김정기;최영민;이형힉;허원주
    • Radiation Oncology Journal
    • /
    • 제14권3호
    • /
    • pp.237-244
    • /
    • 1996
  • 목적 : 의료용 선형가속기의 Independent Collimator는 현재 광범위하게 사용되고 있다. 그러나 방사선량의 계산과 MU(Monitor Unit)의 계산에 사용되는 모든 기본 자료는 대칭 조사면를 기준으로 작성되었기 때문에 independent collimator를 사용한 비대칭적인 조사면의 경우 현재 사용하고 있는 계산 방식을 그대로 적용함에 무리가 있을 것으로 생각된다. 따라서 이러한 의문에 대한 체계적이고 과학적인 검토가 필요할 것으로 사료되어 본 연구를 진행하였다. 대상 및 방법 :본 연구는 Dual Photon Beam(6MV와 15MV)을 산출(産出)하는 선형가속기(Linac 1800, Varian Co)에서 collimator 사용시 산란 방사선의 총채로 표현되어지는 field size factor, beam qualify에 영향을 미치는 HVL와 PDD를 조사하였다. 먼저 field size factor는 water phantom(WP 600C Wellhofer, Germany)내의 Dmax에서 field size $3{\times}3cm$에서 $35{\times}35cm$까지의 방사선량의 변화를 square field로 $1cm^2$씩 증가시켜 가며 0.6cc ion chamber(NE 2571)로 측정하였다. Beam quality는 100cm SSD(source-surface distance)에서 $5{\times}5$, $10{\times}10$, $15{\times}15$$20{\times}20cm$ field size로 0, 3 및 10cm off-axis distance와 dmax 4, 10, 15 및 20cm의 깊이에서 측정하였다. Dose distribution을 분석하기 위하여 film densitometer와 water phantom(IC 10 ion chamber)을 사용, $10{\times}10cm$ field size에서 5, 10 및 15cm의 off-axis distance까지의 방사선량의 분포를 관찰하고 대칭 방사선 조사면와 비교 분석하여 실제 isodose 분포에 미치는 영향을 관찰하였다. 결과: 1) Relative field size factor는 중심 축에서 off-axis lateral distance에 따라 다양하게 변화하였는데 6MV X-선의 경우 최대 $3.1\%$, 15MV X-선의 경우 최대 $5\%$까지의 변화를 보였다. 이때 off-axis factor를 구하여 교정을 하였을 경우 중심 축의 field size factor와 거의 유사한 값에 도달할 수 있었다. 2) Beam qualify의 변화를 관찰하기 위한 실험에서 HVL는 off-axis distance가 멀어질수록 감소하였고 PDD도 off-axis distance가 멀어지고 측정 깊이가 깊어질수록 감소되는 현상을 보였다. 통상적인 방사선 치료시에 이용되는 $5{\times}5cm$ 이상의 field size와 15cm 이내의 깊이에서는 3cm 와 l0cm의 off-axis에서 6MV X-선은 평균 $0.5\%$$2\%$, 15MV X선은 $0.4\%$$1.4\%$의 감소 현상을 보여 큰 편차를 관찰할 수 없었다. 3) Isodose distribution은 off-axis distance가 멀어질수록 depth dose의 증가치가 감소되었으며 특히 central axis의 가장자리 부위에서는 isodose curve의 위축이 확연하였다. 결론 : Independent collimator를 사용하여 비대칭 방사선 치료를 할 경우 MU의 계산은 off-axis factor와 PDD 보정이 필수적이며 임상적으로는 중심 축에서의 과소조사에 대한 정밀한 주의가 필요할 것으로 사료된다.

  • PDF

시축 변화와 홍채 편심에 따른 정밀모형안의 광학적 성능 분석 (An Analysis of Optical Performance of the Finite Schematic Eye According to Iris Eccentricity and Visual Axis change)

  • 김봉환;한선희
    • 한국안광학회지
    • /
    • 제15권2호
    • /
    • pp.151-154
    • /
    • 2010
  • 목적: 시축과 홍채의 편심에 따른 정밀모형안의 광학적 성능 변화를 분석하고자 하였다. 방법: 기존에 설계되어진 Radial GRIN과 Spherical GRIN 형태의 수정체를 갖는 정밀모형안을 이용하여 홍채의 위치를 코 방향으로 0.5 mm 편심시키고 시축은 절점을 기준으로 코방향으로 $5^{\circ},$ 아래로 $2.5^{\circ}$ 기울여 중심와의 위치에 상측초점이 위치하도록 하였다. 그리고, 실제의 눈과 동일하도록 광학계를 구성하여 광학적 성능 변화를 분석하였다. 결과: 전체적인 수차 분포가 실안의 성능과 비교하여 많은 차이를 나타내고 있었다. 특히, 광학계의 중앙 부위를 통과하는 영역에서 가장 큰 차이를 나타내고 있었다. 그리고, 구면수차가 가장 큰 차이를 나타냈으며, 주변부 굴절력 오차와 상면만곡은 (+) 방향으로 수차분포가 치우쳐져 있었다. 결론: 시축과 홍채 편심을 고려한 실안과 유사한 정밀모형안을 설계하는데 있어서 가장 유념해야 할 부분은, 광학계의 중앙 부위를 통과하는 영역에서의 수차 보정이다. 먼저, 가장 큰 차이를 나타내고 있는 구면수차를 보정하고, (+)방향으로 치우쳐 있는 주변부 굴절력 오차와 상면만곡은 (-)방향으로 이동하도록 고려해야 할 것이다.

리니어 모터의 직각도 측정과 대각선 오차 보정에 관한 연구 (A study on the diagonal error compensation and squareness measurement of linear motor)

  • 김준현;이창우;송준엽
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.287-288
    • /
    • 2006
  • This paper introduces an approach of method to compensate accuracy error of diagonal direction. The measurement of squareness error is an important parameter in performance test of two axis Linear Motor and this exerts influence on accuracy error of diagonal test. However, previous knowledge management approaches are limited in deviation measurement of optical axis or restrictive elements of diagonal measurements using laser interferometer. But this proposed method calculated diagonal accuracy error which was occurred by squareness error and compensated squareness error using orthogonal correction method of PMAC. From this result, diagonal accuracy error is significantly reduced. This experimental results show that geometric error of squareness error is easily corrected by dynamic coordinate correction.

  • PDF