• Title/Summary/Keyword: corona discharging

Search Result 26, Processing Time 0.019 seconds

Functional Finishing of Nonwoven Filter for Dust-proof/Medical Masks by Corona Discharging Treatment (코로나 방전에 의한 방진/의료용 마스크 여과재의 기능화 가공)

  • Hong, Young-Ki
    • Textile Coloration and Finishing
    • /
    • v.25 no.3
    • /
    • pp.232-239
    • /
    • 2013
  • In this study, 25gsm melt-blown polypropylene nonwoven for dust-proof/medical masks was finished by the corona discharging treatment. The influence of corona discharging parameters on the filtration efficiency was investigated. Several parameters such as discharging voltage, discharging speed, distance to discharging wire and configuration of discharging system had an effect on filtration efficiency, while the parameters had no effect on breathing resistance. Optimum corona discharging conditions are as follows: Wires were installed on the upper part of the nonwoven and paper pipe was installed on the lower part of the nonwoven having a distance of 5cm. The sequence of wire voltages was +60 kV, +60 kV, 0, -60 kV, and -60 kV. The discharging voltage and speed were 60 kV and 30m/min respectively. The nonwoven treated by corona discharging at the optimum condition showed a filtration efficiency of 80% or more, which is suitable for dust-proof/medical masks.

Water Droplet Ejection Characteristics of a Wet Porous Point-Plate Airgap (다공성 수침-평판전극간의 수적 방출 특성)

  • Jung, Jae-Seung;Lee, Woo-Seok;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2005-2010
    • /
    • 2009
  • Water droplet ejection characteristics of a point-to-plate airgap, with a wet porous point as a corona electrode, has been investigated. And the water droplet traces, charge, mass and number were measured experimentally. More particles are observed with wet porous point than metal point because the corona-discharging wet porous point can eject a number of water droplets. The water droplets ejected from the positive-corona-discharging wet porous point showed very fine traces as compared with those from the negative-corona-discharging wet porous point. Moreover, the water droplets ejected from the AC-corona-discharging wet porous point showed granular-like larger traces. It was shown that the weak corona discharge can eject smaller water droplets with larger ratio of mass-to-charge than the intense corona discharge.

Surface treatment of polyethylene terephthalate films by corona discharge (코로나방전에 의한 polyethylene terephthalate 필름의 표면처리)

  • 김명룡
    • Electrical & Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.316-323
    • /
    • 1995
  • A vital step in magnetic tape manufacturing is the surface modification of polymer substrate prior to ink application. A critical element for good adhesion of magnetic ink on polymeric substrate is the ability to join ink in cost-effective manner. Corona discharging is one of the effective methods of modifying polymer surface to improve adhesion while maintaining the desirable properties of the film itself. Surface treatment by corona which is exposure of film surface to electron or ion bombardment, rather than mere exposure to active species, like atomic oxygen or ozone, can enhance adhesion by removing contaminant, electret, roughening surface, and/or introducing reactive chemical groups. Reactive neutrals, ions, electron and photons generated during the corona treatment interact simultaneously with polymers to alter surface chemical composition, wettability, and thus film adhesion. However, it is highly recommended that extensive chains scission be avoided because it can lead to side-effect by forming sticky matter, resulting in dropouts. This paper reviews principles of surface preparation of polymer substrate by corona discharging. In addition, the experimental section provides a description of parameter optimization on corona discharging treatment and its side-effect. Experimental results are discussed in terms of surface wetting as determined by contact angle measurements.

  • PDF

The EMTP Analysis and Characteristics of Load Impedance on Various Electrode length, Pulse Repetition in Pulse Corona Discharging (펄스코로나 방전의 전극길이, 펄스반복율에 따른 부하 임피던스 변화 특성 및 EMTP 해석)

  • Jeong, Jong-Han;Song, U-Jeong;Jeon, Jin-An;Jeong, Hyeon-Ju;Hong, Jeong-Hwan;Kim, Hui-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.4
    • /
    • pp.158-163
    • /
    • 2002
  • The pulsed Power system has been widely used to many applications, such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power system, often generator, etc. In this paper, we study EMTP analysis and characteristics of critical voltage and load in impedance on various electrode length of pulse corona. To obtain a stable pulse voltage, we designed a compact pulse generator switched MOSFET and tested their characteristics by adjusting electrode length and pulse repetition. As a re sult, critical voltage of pulse corona and load impedance on increasing electrode length were decreased. These results indicate we can control critical voltage of pulse corona and suppress arc discharging between two electrodes.

Surface Safety Characteristics of Polypropylene Surface Treatment by Variation of Rolling Speed and The Electric Power of Corona Discharge (코로나방전 표면 처리시 이동속도 및 공급전력 변화에 따른 폴리프로필렌 표면 안전성 특성)

  • Lee, Su Hwan;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.41-46
    • /
    • 2018
  • Experiments were carried out the phenomenal observation on effect of corona treated hotmelt laminating film in process of manufacture by 2 kinds of rolling speed and electric power variatons. Surface treatment by corona which is exposure of film surface to electron of ion bombardment, rather than mere exposure to active species, like atomic oxygen or ozone, can enhance adhesion by removing contaminant, electret, roughening surface, and introducing reactive chemical group. Reactive neutrals, ions, electron and photons generated during the corona treatment interact simultaneously with polymers to alter surface chemical composition, wettability, and thus film adhesion. However, it is highly recommended that extensive chains scission is avoided because it can lead to side-effect by forming sticky matter, resulting in dropouts. This paper reviews principles of surface preparation of polypropylene substrate by corona discharging. In addition, the experimental section provides a description of parameter optimization on corona discharging treatment and its side-effect. Experimental results are discussed in terms of surface wetting as determined by contact angle and SEM measurements. When the rolling speed of the film decreased from 1.666 [m / sec] to 0.083 [m / sec], contact angle decreased from $80[^{\circ}]$ to $64[^{\circ}]$, and the wettability was greatly improved. As the supply power increased from 0.4 [kVA] to 2 [kVA] at the corona discharge surface treatment, the contact angle decreased from $77[^{\circ}]$ to $65[^{\circ}]$, and the wettability was greatly improved.

A study on the Corona Electrification Phenomena for Polyvinyl chloride (PVC) (폴리염화비닐(PVC)의 코로나 대전현상에 관한 연구)

  • 박구범;황명환;조기선;이덕출;임헌찬
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.2
    • /
    • pp.57-62
    • /
    • 1992
  • In this thesis, the electrification phenomenon was studied by measurement of charging current and discharging current in polymers when the carriers generated by corona discharge were supplied to the surface of polymers. Corona charging current of PVC, polar and noncrystalline polymer, was larger than that of nonpolar and amorphous polymers. Corona charging current on the specimen of naked upper surface (CIM) was larger than charging current on the specimen of electrode made. Carrier injection differed from interfacial phase of polymer surFace. The transfer phenomenon vaned with chemical structure of polymer and then the polar effect of PVC was remarkable because of large electron affinity of Cl. In the characteristics of discharging current of PVC, the abnormal current was observed. It was supposed that this phenomena presented the trap of injected carriers in PVC and that static electricity phenomenon was generated by trap.

  • PDF

Development and Its Characterization of Earth Plate for Early Streamer Discharge (조기방전용 접지판의 개발 및 특성)

  • Choi, Sang-Won;Her, Yong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.46-48
    • /
    • 2014
  • This paper compared and demonstrated the performance of the earth plate for conventional type and early streamer discharging type developed a new plate in order to improve the performance of the ground plate for use in grounding. The results obtained are shown below; early streamer discharge earth plate was high 5 kV on DC flashover voltage and corona discharge current was higher than about 2 times under the same test conditions compared to the conventional earth plate. From the experiential result, streamer discharge earth plate had a function of rapid inflow/out flow than the general ground plane because of by corona discharge current to be generated in the sharp serrated in formed the ground plane when strike current occurred. In the future, the newly developed early streamer discharge ground plate would be beneficial for grounding work to be widely used to promote the convenience and economy of construction.

The Study on Potential Characteristics and Corona Discharge of Composite Insulating Material (복합절연재료 FRP의 코로나 대전파 전위감쇄특성에 관한 연구)

  • 이백수;신태현;김진식;강대하;이덕출
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.365-368
    • /
    • 1995
  • Charge decay, thermally stimulated current (TSC), charging and discharging currents(I) are measured for corona-charged composite insulating materials. In this study, We will make an experiment in charge decay on composite material surface, TSC, polarity effect and the others in order to analysis its mechanism. Especially, Fiber glass Reinforced Plastics(FRP) is the best composite material which has been so far. Therefore, Its worthy of notice to investigate its characteristic. And then some other materials will be focused on. This experiment measured characteristic of charge decay, dependence of discharging-time and other electrostatic characteristics on FRP.

  • PDF

Case Study on the Electrostatic Hazards in the Coating Mechanical System (도장설비에서의 정전기 재해 사례 연구)

  • Kim, Gil-Tae;Jung, Young-Man;Lee, Jae-Keun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.602-606
    • /
    • 2006
  • The electrostatic is well known phenomena. The fires and explosions caused by electrostatic occur often in the coating mechanical system. This paper presents various cases of electrostatic hazards, reasons why electrostatic hazards are happened, and methods for preventing electrostatic hazards. Generally the electrostatic can be lead to corona discharging, streaming electrification, and impinging electrification in the coating process. Corona discharging happens at electrostatic spray gun with 70 kV. Streaming electrification occurs at mixing process between paint and thinner, and transportation process with thinner. Impinging electrification is shown when the thinner are sprayed to drums. For the purpose of preventing the electrostatic discharge and damage, conductors should be ground, surface electric potential of should be decreased in using electrostatic shielding and ground, and flow of thinner should be controlled acceptable velocity.

  • PDF

Analysis of Image and Development of UV Corona Camera for High-Voltage Discharge Detection (고전압 방전 검출용 자외선 코로나 카메라 개발 및 방전 이미지 분석)

  • Kim, Young-Seok;Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Choi, Myeong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.9
    • /
    • pp.69-74
    • /
    • 2011
  • In this paper, the UV corona camera was developed using the solar blind and Multi Channel Plate(MCP) technology for the target localization of UV image. UV camera developed a $6.4[^{\circ}]{\times}4.8[^{\circ}]$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. UV camera to measure the discharge count and the UV image was developed, compared with a commercial camera, there was no significant difference. In salt spray environments breakdown voltage was lower than the normal state, thereby discharging the image was rapidly growing phenomenon.