• Title/Summary/Keyword: corner frequency

Search Result 105, Processing Time 0.021 seconds

Compact Orthomode Transducer for Field Experiments of Radar Backscatter at L-band (L-밴드 대역 레이더 후방 산란 측정용 소형 직교 모드 변환기)

  • Hwang, Ji-Hwan;Kwon, Soon-Gu;Joo, Jeong-Myeong;Oh, Yi-Sok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.7
    • /
    • pp.711-719
    • /
    • 2011
  • A study of miniaturization of an L-band orthomode transducer(OMT) for field experiments of radar backscatter is presented in this paper. The proposed OMT is not required the additional waveguide taper structures to connect with a standard adaptor by the newly designed junction structure which bases on a waveguide taper. Total length of the OMT for L-band is about 1.2 ${\lambda}_o$(310 mm) and it's a size of 60 % of the existing OMTs. And, to increase the matching and isolation performances of each polarization, two conducting posts are inserted. The bandwidth of 420 MHz and the isolation level of about 40 dB are measured in the operating frequency. The L-band scatterometer consisting of the manufactured OMT, a horn-antenna and network analyzer(Agilent 8753E) was used STCT and 2DTST to analysis the measurement accuracy of radar backscatter. The full-polarimetric RCSs of test-target, 55 cm trihedral corner reflector, measured by the calibrated scatterometer have errors of -0.2 dB and 0.25 dB for vv-/hh-polarization, respectively. The effective isolation level is about 35.8 dB in the operating frequency. Then, the horn-antenna used to measure has the length of 300 mm, the aperture size of $450{\times}450\;mm^2$, and HPBWs of $29.5^{\circ}$ and $36.5^{\circ}$ on the principle E-/H-planes.

Measurement of Backscattering Coefficients of Rice Canopy Using a Ground Polarimetric Scatterometer System (지상관측 레이다 산란계를 이용한 벼 군락의 후방산란계수 측정)

  • Hong, Jin-Young;Kim, Yi-Hyun;Oh, Yi-Sok;Hong, Suk-Young
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.2
    • /
    • pp.145-152
    • /
    • 2007
  • The polarimetric backscattering coefficients of a wet-land rice field which is an experimental plot belong to National Institute of Agricultural Science and Technology in Suwon are measured using ground-based polarimetric scatterometers at 1.8 and 5.3 GHz throughout a growth year from transplanting period to harvest period (May to October in 2006). The polarimetric scatterometers consist of a vector network analyzer with time-gating function and polarimetric antenna set, and are well calibrated to get VV-, HV-, VH-, HH-polarized backscattering coefficients from the measurements, based on single target calibration technique using a trihedral corner reflector. The polarimetric backscattering coefficients are measured at $30^{\circ},\;40^{\circ},\;50^{\circ}\;and\;60^{\circ}$ with 30 independent samples for each incidence angle at each frequency. In the measurement periods the ground truth data including fresh and dry biomass, plant height, stem density, leaf area, specific leaf area, and moisture contents are also collected for each measurement. The temporal variations of the measured backscattering coefficients as well as the measured plant height, LAI (leaf area index) and biomass are analyzed. Then, the measured polarimetric backscattering coefficients are compared with the rice growth parameters. The measured plant height increases monotonically while the measured LAI increases only till the ripening period and decreases after the ripening period. The measured backscattering coefficientsare fitted with polynomial expressions as functions of growth age, plant LAI and plant height for each polarization, frequency, and incidence angle. As the incidence angle is bigger, correlations of L band signature to the rice growth was higher than that of C band signatures. It is found that the HH-polarized backscattering coefficients are more sensitive than the VV-polarized backscattering coefficients to growth age and other input parameters. It is necessary to divide the data according to the growth period which shows the qualitative changes of growth such as panicale initiation, flowering or heading to derive functions to estimate rice growth.

A Survey on the Utilization University Food Service by Student in Daejeon City (대전지역 대학생들의 대학급식소 이용실태 조사)

  • 박상욱;장영상
    • Korean journal of food and cookery science
    • /
    • v.14 no.4
    • /
    • pp.400-406
    • /
    • 1998
  • Questionnaire survey was done on the utilization status of college feeding facilities by students. Three hundred and nine students from three universities in Daejeon city, Korea participated in this survey. The results were summarized as followings. 1. Students who had experience of utilizing college feeding facilities were totalled to two hundred and ninety six. Among them 87.50% students were utilizing for lunch. Female students utilization ratio for lunch was 17.94% higher than male. College B students showed specially low utilization ratio. 2. Utilization frequency ratio of once per day was the highest as 30.72%. College C showed the highest utilization ratio. 3. Students utilized the campus food services most frequently as 47.97%, the restaurant outside campus the next and snack corner in the campus the last. 4. Reasons for the utilization were listed as low price, time saving, near place and no other place to eat. 5. Reasons for the not utilization were indicated as tasteless, simple menu and noisy and crowded. 6. Recommendations for the improvements of' college feeding facilities can be summarized to emphasize on taste, menu variation, sanitation, price decrease and comfortable atmosphere.

  • PDF

A study on optical coherence tomography system using optical fiber (광섬유를 이용한 광영상 단층촬영기에 관한연구)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, we studied the OCT(Optical Coherence Tomography) system which it has been extensively studied because of having some advantages such as high resolution cross-sectional images, low cost, and small size configuration. A basic principle of OCT system is Michelson interferometer. The characteristics of light source determine the resolution and the transmission depth. As a results, the light source have a commercial SLD with a central wavelength of 1,285 nm and FWHM(Full Width at Half Maximum) of 35.3 nm. The optical delay line part is necessary to equal of the optical path length with scattered light or reflected light from sample. In order to equal the optical path length, the stage which is attached to reference mirror is moved linearly by step motor And the interferometer is configured with the Michelson interferometer using single mod fiber, the scanner can be focused of the sample by using the reference arm. Also, the 2-dimensional cross-sectional images were measured with scanning the transverse direction of the sample by using step motor. After detecting the internal signal of lateral direction at a paint of sample, scanner is moved to obtain the cross-sectional image of 2-demensional by using step motor. Photodiode has been used which has high detection sensitivity, excellent noise characteristic, and dynamic range from 800 nm to 1,700 nm. It is detected mixed small signal between noise and interference signal with high frequency After filtering and amplifying this signal, only envelope curve of interference signal is detected. And then, cross-sectional image is shown through converting this signal into digitalized signal using A/D converter. The resolution of the OCT system is about 30$\mu\textrm{m}$ which corresponds to the theoretical resolution. Also, the cross-sectional image of ping-pong ball is measured. The OCT system is configured with Michelson interferometer which has a low contrast because of reducing the power of feedback interference light. Such a problem is overcomed by using the improved inteferometer. Also, in order to obtain the cross-sectional image within a short time, it is necessary to reduce the measurement time for improving the optical delay line.

  • PDF

The effect of palatal height on the Korean vowels (구개의 높이가 한국어 모음 발음에 미치는 효과에 관한 연구)

  • Chung, Bo-Yoon;Lim, Young-Jun;Kim, Myung-Joo;Nam, Shin-Eun;Lee, Seung-Pyo;Kwon, Ho-Beom
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.69-74
    • /
    • 2010
  • Purpose: The purpose of this study was to analyze the influence of palatal height on Korean vowels and speech intelligibility in Korean adults and to produce baseline data for future prosthodontic treatment. Material and methods: Forty one healthy Korean men and women who had no problem in pronunciation, hearing, and communication and had no history of airway disease participated in this study. Subjects were classified into H, M, and L groups after clinical determination of palatal height with study casts. Seven Korean vowels were used as sample vowels and subjects'clear speech sounds were recorded using Multispeech software program on computer. The F1 and the F2 of 3 groups were produced and they were compared. In addition, the vowel working spaces of 3 groups by /a/, /i/, and /u/ corner vowels were obtained and their areas were compared. Kruskal-Wallis test and Mann-Whiteny U test were used as statistical methods and P < .05 was considered statistically significant. Results: There were no significant differences in formant frequencies among 3 groups except for the F2 formant frequency between H and L group (P = .003). In the analysis of vowel working space areas of 3 groups, the vowel working spaces of 3 groups were similar in shape and no significant differences of their areas were found. Conclusion: The palatal height did not affect vowel frequencies in most of the vowels and speech intelligibility. The dynamics of tongue activity seems to compensate the morphological difference.