코리올리스 질량유량계의 유량측정에 영향을 미치는 인자에 관한 실험적 연구 (An Experimental Study on the Influential Factors of Flow Measurement with Coriolis Mass Flowmeter)

  • 임기원;이완규
    • 대한기계학회논문집B
    • /
    • 제27권12호
    • /
    • pp.1699-1707
    • /
    • 2003
  • Coriolis mass flowmeter(CMF), which can measure the mass flow directly, is getting rapid attention for the industrial and custody transfer purpose. In order to study the characteristics and the applicability of CMF, it is tested with the national flow standard system. Two types of sensing tube, U-type and straight type, are employed in the test. Water, spindle oil and viscosity Standard Reference Material whose viscosities are 1, 20 and, 67 $\textrm{mm}^2$/s, respectively, are studied. It is shown that the linearity of CMF is getting deteriorated as the fluid viscosity increases, which is due to the zero drift and the relaxation time of the fluid. To test its applicability in the case of high pressured gas, it is calibrated using compressed air, It shows 1∼l.6 % deviations compared to the calibration results using water. It concludes that the fluid velocity in CMF should be lower than the sonic velocity. In addition, the effects of the vibration from the pipeline and pump on CMF as well as the long term stability are studied.

소형 코리올리 질량 유량계의 개발 (Development of Small Size Coriolis Mass Flowmeter)

  • 임기원;지정근
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.497-504
    • /
    • 2006
  • A Coriolis mass flowmeter(CMF), which has U-Shaped unique measurins tube was developed fo. direct mass flow measurement. In order to convert the time difference between two measuring tubes motion into mass flowrate and flow quantity, a signal processing circuit, as a part of CMF, was also developed. The CMF was designed as the 15 mm nominal diameter of pipe connection and the 8 mm stainless steel(sus 316) pipe was used for measuring tube. To maximize the flow signal(time difference) from the measuring tubes, the natural frequency of measuring tube was adjusted as 220 Hz, which is same as the frequency of exciter. The maximum displacement at the end of the measuring tube was measured as 0.05 mm and the maximum time difference between two measuring tubes was observed as $20{\mu}s$, which was proper for discrimination and measuring range of CMF. The developed CMF was tested against the gravimetric flowmeter calibrator in the range of 3 kg/min and 30 kg/min. The results showed that the CMF has good linearity and repeatability in the tested flow range. Large size of CMF base on the current study experience will be developed.

코리올리 질량유량계를 이용한 액화석유가스(LPG) 정량 측정 방법 연구 (A Study on Liquified Petroleum Gas(LPG) Fuel Quantitative Method using Coriolis Mass Flowmeter)

  • 박태성;성상래;임의순;이정민;이명식;강형규
    • 한국가스학회지
    • /
    • 제22권6호
    • /
    • pp.109-122
    • /
    • 2018
  • 국내 LPG 미터는 "계량에 관한 법률"에 의거 LPG 정량에 대한 검사가 실시되고 있다. LPG 미터는 "계량에 관한 법률 시행령"에 따라 3년마다 재검정이 실시된다. 검사 시 최대허용오차는 ${\pm}1.0%$ 이내, 사용오차는 ${\pm}1.5%$ 이내이다. 정량 측정 시에는 밀도부액계, 저울, 압력용기를 사용한다. LPG는 온도와 압력에 따라 부피 변화의 정도가 매우 심하다. 현행 정량 측정 방법은 LPG의 부피를 구하기 위해 온도 및 압력, 밀도를 측정해야 하며, 이에 따른 장비들이 필요하다. 반면에 코리올리 질량유량계는 질량유량, 밀도, 온도를 동시에 측정하며, 컴퓨터 프로그램을 사용하여 측정값을 필요한 값으로 변환 및 산출 할 수 있어, 산업현장에서 널리 적용되고 있다. 본 연구에서는 LPG 정량 측정에 대한 기초연구로서, 코리올리 질량유량계를 이용하여 LPG 충전기에서 나온 LPG 부피를 측정했다. 또한, 기존 LPG 충전기 검사방법과의 비교를 통해 코리올리 질량유량계를 이용한 LPG 충전기 검사도 가능하다는 결론을 얻었다.

코리올리 유량계를 이용한 정밀유량측정에 관한 연구 (A Study of the Precise Flow Measurement using Coriolis flowmeter)

  • 김인태;조대기;정민제;이재원;서혁;유명종
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제30회 춘계학술대회논문집
    • /
    • pp.61-64
    • /
    • 2008
  • 액체추진제 추력기의 경우, 성능평가를 위해 진공연소시험이 필수적으로 요구되며 이때 공급되는 추진제의 유량이 비추력 계산시 중요한 영향을 미치는 인자가 된다. 본 논문에서는 정밀 유량측정에 대한 기초연구로서, 코리올리 유량계를 이용하여 모의추진제인 DIW를 사용한 수류시험을 수행하였으며 연속모드 및 펄스모드 각각에 대해 결과분석이 이루어졌다. 마지막으로 해외연소시험 데이터와의 비교를 통해 수류시험 결과와의 검증을 확인하였다.