• Title/Summary/Keyword: copper concentrate

Search Result 31, Processing Time 0.021 seconds

Kinetic Studies on the Oxidation of Copper Concentrate Particles (동정광 입자의 산화반응에 관한 속도론적 연구)

  • Sohn Ho-Sang
    • Resources Recycling
    • /
    • v.11 no.6
    • /
    • pp.47-54
    • /
    • 2002
  • Copper concentrate particles were fed from the top of vertical reaction tube of 2.8 cm ID and 65 cm long with an $O_2$-$N_2$ gas mixture. The reaction tube was heated to 1000 K to 1400 K. The copper concentrate particles were very rapidly oxidized and melted down during their descent in the reaction tube. The particle temperature were calculated by combining an unreacted core model, mass transfer between gas and particles, and heat transfer between gas, particles and tube wall. The particle temperature reached its maximum at the height of 20 to 30 cm from the top of the reaction tube, and it attained about 1700 K at higher oxy-gen partial pressure. The most particles were melted at the oxygen partial pressure above 0.2 atm.

Influence of counter anions on metal separation and water transport in electrodialysis treating plating wastewater

  • Oh, Eunjoo;Kim, Joohyeong;Ryu, Jun Hee;Min, Kyung Jin;Shin, Hyun-Gon;Park, Ki Young
    • Membrane and Water Treatment
    • /
    • v.11 no.3
    • /
    • pp.201-206
    • /
    • 2020
  • Electrodialysis (ED) is used in wastewater treatment, during the processing and recovery of beneficial materials, to produce usable water. In this study, sulfate and chlorine ions, which are the anions majorly used for electroplating, were studied as factors affecting the recovery of copper, nickel and water from wastewater by electrodialysis. Although the removal rates of copper and nickel ions were slightly higher with the use of chlorine ions than of sulfate ions, the removal efficiencies were above 99.9% under all experimental conditions. The metal ions of the plating wastewater flowed through the ion exchange membrane of the diluate tank and the concentrate tank while all the water moved together due to electro-osmosis. The migration of water from the diluate tank to the concentrate tank was higher in the presence of a monovalent chloride ion compared to that of a divalent sulfate ion. When sulfate was the anion used, the recoveries of copper and nickel increased by about 25% and 30%, respectively, as compared to the chloride ion. Therefore, when divalent ions such as sulfate are present in the electrodialysis, it is possible to reduce the movement amount of water and highly concentrate the copper and nickel in the plating wastewater.

Froth Flotation of Copper Ore from Jambi Deposit, Indonesia (인도네시아 잠비산 동광석의 부유선별 특성 연구)

  • Kim, Hak-Soon;Jeon, Ho-Seok;Kim, Byoung-Gon;Baek, Sang-Ho
    • Journal of the Mineralogical Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.243-250
    • /
    • 2010
  • Froth flotation of complex copper ore from Indonesia Jambi mine has been carried out to produce high-grade Cu concentrate. Since the ore contained minor Cu sulfides in addition to major Cu carbonate (malachite), copper concentrate was recovered by two-stage process of flotation, which consisted of copper sulfide flotation using xanthate followed by copper oxide flotation using oleic acid. The copper sulfide concentrate of 57.5% Cu grade with 9.5% recovery was obtained by copper sulfide flotation under conditions of 300 g/t collector (1 : 1 mixture of xanthate series Aero Promoter 211 and Aero Promoter 242) and pH 6.0 pulp. In subsequent copper oxide flotation on sink products, the concentrate of 30.8% Cu grade with 92.1% recovery was obtained under the conditions of oleic acid 300 g/t, AF65 50 g/t, pH 8.0 and 2 times cleaning. The flotation techniques which can achieve a Cu grade of 36.1% and a recovery of 92.1% have been developed from the two-stage process of flotation.

A Study on the Bioleaching of Cobalt and Copper from Cobalt Concentrate by Aspergillus niger strains (Aspergillus niger 균주를 이용(利用)한 코발트 정광(精鑛)으로부터 코발트 및 구리의 미생물(微生物) 침출(浸出) 연구(硏究))

  • Ahn, Hyo-Jin;Ahn, Jae-Woo;Bang, Duk-Ki;Kim, Meong-Woon
    • Resources Recycling
    • /
    • v.22 no.2
    • /
    • pp.44-52
    • /
    • 2013
  • Bioleaching behavior of metal ions for recovery of cobalt and copper from cobalt concentrate was investigated by employing three Aspergillus niger strains. Various factors, such as organic acid generation with fungi type, pH of the culture and pulp density were studied. The results showed that the best fungi for organic acid(citric acid and oxalic acid) generation was A. niger KCTC 6144 using Malt Extract Broth culture at initial pH 3.5. But A. niger KCTC 6985 was more effective for the leaching of cobalt and copper from cobalt concentrate. Our results showed that 82% cobalt and 98% copper was dissolved by A. niger KCTC 6985 at 10g/L pulp density, at pH 3.5 and $24^{\circ}C$ after 15 days incubation.

Recovery of copper from the copper converter slag(II) (동제연소 전노슬래그로부터 동의 회수(II))

  • Oh, Jae-Hyun;Kim, Mahn;Kim, Mi-Sung;Yoo, Taik-Soo
    • Resources Recycling
    • /
    • v.2 no.4
    • /
    • pp.33-41
    • /
    • 1993
  • In recovering copper from the copper converter slag, various separation methods, such as flotation, sieving and magnetic separation had been tried. The copper converter slag used in this study was prepared in two ways, i.e. 2 hour cooled and 10 hour cooled. From the flotation of copper slag, 45% Cu concentrate is obtained and the amount of copper recovery is about 93%. Before the flotation, copper in the slag could be also pre-recovered using sieving and separation. It is also found that as the content of copper in the concentrate increa-ses, that of arsenic increase, while zinc and iron contents decrease.

  • PDF

Recovery of Nickel and Copper from Scraped Nickel Condensers

  • Liang, Ruilu;Kikuchi, Eiji;Kawabe, Yoshishige;Sakamoto, Hiroshi;Fujita, Toyohisa
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.188-192
    • /
    • 2001
  • Magnetic separation and sulphidization-flotation for recovery of nickel and copper from two types of scraped condenser wastes, containing 8- l4% nickel and 2-4% copper, were studied. The effects of magnetic field intensities, classification, and grinding on the recovery of nickel and copper were investigated. According to the characteristics of nickel and copper in the scraps, classification-magnetic separation, different magnetic field intensities, and stages-grinding-cleaning of rough concentrate were investigated. The nickel concentrates containing 38-65% nickel with 84-97% recoveries and the copper concentrates containing 25-43% nickel with 35-60% recoveries were obtained by classification-magnetic separation. In addition, copper concentrates containing 26-45% copper with 76-88% recoveries were obtained by sulphidization-flotation from magnetic tailings and middling products.

  • PDF

The Survey on Froth Floatation of Low Grade Copper Ore from the Australia (호주산 저품위 동광의 부유선별에 관한 특성조사)

  • Kim, Joon Soo;Kim, Woo Jin;Hwang, Ha;Kim, Myong Jun;Kim, Wantae
    • Resources Recycling
    • /
    • v.25 no.6
    • /
    • pp.98-104
    • /
    • 2016
  • The purpose of this study is to obtain an optimum condition of the concentrate by floatation using Australian low grade copper ore of suitable particle size by crushing, grinding and sizing. The effect of the dosage of collector, activator, depressant and change of acidity on the floatation was investigated. The floatation conditions comprising of pH 9.0 acidity, 500g/t $CuSO_4{\cdot}5H_2O$ activator, 500g/t K.E.X. collector, 1500g/t $Na_2SO_3$ depressant and 25wt.% plup density were optimized. Grade and recovery of copper in the concentrate obtained by froth floatation under optimum conditions were 4wt.% and 65wt.% respectively.

Effect of Operating Parameters on the Removal Performance of Copper Ion by Electrodialysis (전기투석을 이용한 구리이온의 제거 시 운전인자의 영향)

  • Jung, Hyo-Sang;Lee, Gangchoon
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.54-60
    • /
    • 2011
  • To evaluate the feasibility of electrodialysis for copper removal from industrial wastewater, the effect of operating parameters on the removal of copper was experimentally estimated. The limiting current density (LCD) linearly increased with the copper concentration and the flow rate. The time when the copper concentration of diluate reaches to 3 mg/L was linearly proportional to initial concentration of diluate, and the concentration of concentrate did not affect the removal rate. Increase in the flow rate gave a positive effect on the removal rate and became insignificant at flow rates greater than 2.4 L/min. The removal rate increased with the applied voltage. From the operation of the electrodialysis module used in this research, the flow rate of 2.4 L/min and the voltage corresponding to the 80~90% of LCD were found be the optimum operating condition for the copper removal from highly concentrated copper solutions.

Design and Fabrication of Light-Weight Composit Bus Bar (복합경량 부스바의 설계 및 제작)

  • Bae Joon-Han;Bea Duck-Kweon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.8
    • /
    • pp.334-340
    • /
    • 2006
  • Copper is widely used in electric wire, cable, conductor in electric devices. As the demand for electric power is increasing rapidly, electric power devices are getting amazingly bigger and complicated. The using of light-weight conductor can reduce the size and making cost of the electric devices. In high-frequency application, Electric current in a conductor tends to shift to the surface of the conductor, resulting in an uneven current distribution in the inner conductor. In the extreme case the current may essentially concentrate in the 'skin' of the inner conductor as a surface current. In high frequency application, therefore, inner area of copper conductor may replace with aluminum conductor, which reduces the weight of conductor. This paper describes the manufacture and evaluation of composite conductors made of copper and aluminum. The optimum extruding ratio was 16 at $300^{\circ}C$. The electrical resistance of manufactured composite bus bar was $57{\mu}{\Omega}$ at DC and $49.5{\mu}\{Omega}$ at 300Hz.

Chemical Leaching of Co, Cu, Ni, Al, Fe by Organic acid from Cobalt Concentrate (코발트 정광(精鑛)으로부터 유기산(有機酸)을 이용(利用)한 Co, Cu, Ni, Al, Fe의 화학적(化學的) 침출(浸出))

  • Ahn, Jae-Woo;Ahn, Hyo-Jin;Kim, Meong-Woon
    • Resources Recycling
    • /
    • v.20 no.6
    • /
    • pp.63-70
    • /
    • 2011
  • Enviromental friendly leaching process for the recovery of cobalt and copper from the cobalt concentrate was investigated by organic acids as a leaching reagent. The experimental parameters, such as organic acid type, concentrations of leachant, time and temperature of the reaction as well as the solid to liquid ratio were tested to obtain the optinum conditions for the leaching of cobalt and copper. The results showed that citric acid was the most effective leaching reagent among the organic acids used in this experiment. About 99% of cobalt, 95% of copper and 70% of nickel was dissolved by 2.0 M of citric acid. Addition of 3.0 vol.% of hydrogen perioxide was effective to enhance the leaching efficiency and the optinum temperature was found to be about $70^{\circ}C$.