• Title/Summary/Keyword: cop

Search Result 1,228, Processing Time 0.027 seconds

The Effect of Load Variation on the Performance of an Injection Heat Pump with an Economizer (이코너마이저 적용 열펌프 시스템의 부하변화에 따른 성능 특성 연구)

  • Choi, Jong Min;Park, Yong-Jung;Kang, Shin-Hyung
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.3
    • /
    • pp.1-7
    • /
    • 2014
  • Heat pumps have received a fair amount of attention all over the world for their high efficiency and low environmental impact. Employing heat pumps for residential heating and cooling produces only about 2038 kg-$CO_2$/year, an amount which is less than half that of conventional boiler systems. However, the use of single-stage heat pumps becomes uneconomical when they are operated at very low evaporating temperature or high condensing temperature. Two-stage heat pumps systems can be used successfully for low or high temperature applications. In this paper, the experimental study on the performance of two-stage heat pump with an economizer was executed in heating mode. When the secondary fluid inlet temperature to the indoor heat exchanger increased, the COP enhancement rate of two-stage heat pump with an economizer was increased. For all outdoor inlet temperature conditions, the performance of the heat pump with an economizer was higher than it without an economizer.

Performance Characteristics of a Vapor Injection Heat Pump System with Different Sub-cooler Capacity (과냉각 열교환기 용량 변화에 따른 인젝션 히트펌프의 성능 특성)

  • Choi, Jong Min;Park, Yong-Jung;Kang, Shin-Hyung
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.3
    • /
    • pp.17-23
    • /
    • 2014
  • One major breakthrough in the field of heating, ventilation and air conditioning has been the development of heat pumps. Heat pump systems offer economic alternatives for recovering heat from different sources for use in various industrial, commercial and residential applications. In recent years, the heat pump has been tipped to have a very good potential for hot water production. This paper investigated the performance of a vapor injection heat pump with the variation of sub-cooler capacity at heating mode. The heating capacity of the vapor injection heat pump slightly increased with an increment of sub-cooler capacity, while COP didn't increase continuously. The 20% capacity of sub-cooler comparing with system capacity could be used as a standard to select sub-cooler capacity.

Influence of Refrigerant Charge Amount on the Performance of a Water-to-Water Type Ground Source Heat Pump with a Variation of Compressor Speed and Water Flow Rate (용량 가변 및 유량변화에 따른 지열원 물대물 열펌프 유닛의 충전량 변화에 따른 성능 특성)

  • Cho, Chan-Yong;Choi, Jong-Min
    • New & Renewable Energy
    • /
    • v.7 no.4
    • /
    • pp.30-36
    • /
    • 2011
  • The objective of this study is to investigate the effects of the refrigerant charge amount on the performance of a water-to-water ground source heat pump with a variation of compressor speed and the secondary fluid flow rate. The water-to-water ground source heat pump was tested by varying refrigerant charge amount from -40% to 20% of full charge. Compressor speed was changed from 30 Hz to 75 Hz and the secondary fluid flow rate was adjusted from 6 LPM to 14 LPM. For all test conditions, EWTs of an indoor heat exchanger and an outdoor heat exchanger were maintained at standard conditions of ISO 13256-2. The slope of the COP with the variation of charge amount is much steeper at undercharged conditions than that at overcharged conditions. For all compressor speed, the variation of the system performance according to charge amounts showed the similar trends. However, the optimum charge amount of the system increased a little with an increment of compressor speed. When the secondary fluid flow rate decreased, the system was optimized at higher refrigerant charge amount conditions.

Study on Energy Consumption of Air-source, Ground-source and Dual-source Heat Pump during Intermediate Season (공기, 지열 및 복합 열원 열펌프의 중간기 에너지 소비량에 관한 연구)

  • Cho, Yeong Uk;Woo, Tea Ho;Chung, Kwang-Seop;Kim, Youngil
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.4
    • /
    • pp.1-7
    • /
    • 2013
  • This study is to compare energy consumption of air-source, ground-source and dual-source heat pump systems during intermediate season using dynamic simulation. Ground-source heat pump has higher COP than that of air-source but requires additional power consumption of auxiliary equipment such as circulation pump. During intermediate season when the outdoor air temperature is favorable, total COP of air-source heat pump may be greater than that of ground-source when circulation pump power consumption is included. Dual-source heat pump which selects the more favorable heat source is compared with air-source only and ground-source only heat pumps for total power consumption. Results show that power consumption of dual-source heat pump is lower than that of ground-source only by 0.73%.

Performance of Underground Air-to-Water Heat Pump with Direct Contact Heat Exchanger (지하공기-물 직접접촉식 열교환기를 구비한 히트펌프의 성능)

  • Kim, Y.H.;Kang, Y.K.;Sung, M.S.;Ryou, Y.S.;Kim, J.G.;Jang, J.K.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.172.1-172.1
    • /
    • 2010
  • In Jeju, underground air is used for heating greenhouse and fertilizing natural $CO_2$ gas by suppling directly into greenhouse. But greenhouse heating method by direct supply of underground air has several problems as like low temperature below $20^{\circ}C$ or high relative humidity over 90%. The underground air is inadequate in heating of crops such as mangos, oranges with the growing temperature over $20^{\circ}C$. Also if the relative humidity of greenhouse is kept with over 90%, diseases can strike almost of the crops. And also the ventilation loss becomes larger because the air pressure of inside greenhouse by direct supply of underground air is higher. In this study the heat pump system using underground air as heat source was developed and heating performance of the system was analyzed. Heating COP of the system was 2.5~5.0 and rejecting heat into greenhouse and extracting heat from underground air in this heat pump system were 46.5~31.4 kW, 34.9~20.9 kW respectively.

  • PDF

Cycle Analysis of Hot Water Driven Absorption Refrigerator with New Working Absorption Solution (신흡수용액을 이용한 중온수 흡수식 냉동기의 사이클 해석)

  • Gwon, O-Gyeong;Yun, Jae-Ho;Mun, Chun-Geun;Yun, Jeong-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.9
    • /
    • pp.1241-1248
    • /
    • 2002
  • Performance extension of the absorption refrigerator with LiBr solution is often faced to operate very close to the crystallization limit. Especially in the development of an air-cooled cycle, the crystallization of working solution in the system is a very difficult problem to overcome. This paper describes the cycle of hot water driven absorption system using a new working absorption solution instead of LiBr solution to improve the efficiency. In this study, we found out the characteristics of new working absorption solution through the cycle simulation and compared LiBr solution to evaluate. The effect of cooling water temperature, weak solution flow rate, hot water temperature and hot water flow rate were also examined. The COP is increased 22% higher in the case of LiBr+Li1+LiC1+LiNO$_3$$H_2O$, 2% LiBr+HO(CH$_2$)$_3$OH+$H_2O$ than that of LiBr solution for the same operation condition.

EFFECT OF AGRICULTURAL BY-PRODUCT DIETS ON CARCASS CHARACTERISTICS OF FOUR TYPES OF CATTLE IN THE FEEDLOT

  • Dahlan, I.;Rahman-Haron, A.;Sukri, M.H.I.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.5 no.3
    • /
    • pp.455-459
    • /
    • 1992
  • Five type of formulated diet from agricultural by-products (ABP) were fed to four breedtype of cattle in feedlot. The ABP used are palm kernel cake (PKC), palm press fibre (PPF), palm oil mill effluent (POME), cocoa pod (COP), coffee pulp (COF) and pineapple waste (PAP). The formulated diets are PS (52% PKC, 15% PPF and 30% POME), PF (57% PKC, 20% PPF and 20% POME), PA (2% PKC and 55% PAP), CO (42% PKC and 55% COP) and CF (67% PKC and 30% COF) with 1% urea, 1% NaCl and 1% vitamins premix. The cattle breedtypes are Kedah-Kelantan (KK), Brahman-KK (BK), Hereford-KK (HK) and Sahiwal-Friesian (SF). The result showed that breedtype significantly affect all the carcass characteristic except dressing percentage. Each breedtype has it's specific carcass characteristics. HK cattle gave high marbling, BK has high % of carcass bone, KK has high % of carcass meat and low % of carcass fat (lean meat type) and SF has high % of carcass fat. Diet-type significantly affect the deposition of fat in the carcass. High moisture diets (PA and CO) produced significantly higher % carcass bone, the lowest % carcass fat and the highest % carcass meat (65.3%). PF, CF, PA and CO diets produced 63.4%, 59.9%, 55.3% and 54.1% carcass meat respectively.

Immediate Effect of Eye Movement on Static Balance according to Age in Elderly Individuals

  • Seo, Seung-Hee;Bae, Hwi-Bin;Cho, Yea-Jin;Bae, Young-Sook
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.5
    • /
    • pp.274-278
    • /
    • 2016
  • Purpose: This study investigated changes in static balance during eye movement while in an upright standing position and compared static balance in elderly individuals according to age. Methods: A total of 154 elderly persons (male 23, female 136) were enrolled in the study. Participants followed an eye movement program that consisted of randomly occurring pursuit eye movement and saccadic eye movement. Participants were asked to remain in the double-leg standing position for 2 minutes 30 second while fixating their eyes on a specific target, after which they were instructed to perform eye movements for 2 minutes and 30 seconds. Static balance was measured in terms of the area, length, and average speed (cm/s) of the center of pressure (COP) displacement before and after eye movement intervention with the eyes open. Results: The area, length, and velocity of COP displacement improved significantly (p< 0.01) after intervention. No significant differences among age groups were observed. Conclusion: The results indicated that eye movement was an effective intervention for improving static balance in elderly persons.

The Effects of Ankle Strategy Exercise on Balance of Patients with Hemiplegia (편마비 환자의 발목관절 전략 운동이 균형 조절 능력에 미치는 영향)

  • Park, Ki-Hyeon;Kim, Won-Bok
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.1
    • /
    • pp.75-82
    • /
    • 2014
  • PURPOSE: PURPOSE: The purpose of this study was to analyze the effect and examine the feasibility of an intervention of ankle strategy exercise on balance of patients with hemiplegia. METHODS: The subject were randomly allocated to three groups: ankle strategy exercise (group A), balance exercise (group B) and control (group C). Group A was received the conventional physical therapy plus ankle strategy exercises for 20 minutes in one session. Group B was received the same conventional physical therapy plus balance exercises for 20 minutes in one session. Two active groups were performed in the session 3 times a week, for a total of 6 weeks. and Group C was only received the same conventional physical therapy. Balance test was assessed using center of pressure (COP) in the anteroposterior (A-P), mediolateral (M-L) direction, Berg balance scale (BBS) and Timed Up and Go Test (TUG). RESULTS: All groups showed improvements in balance parameters. In especial, the Group A was statistically significant differences in almost part evaluation items and showed more improvements in BBS and TUG parameters than Group B and Group C. and moving distance of M-L COP was more improvements than Group B. CONCLUSION: Ankle strategy exercises had more influence on balance than balance exercises and neurodevelopmental treatment.